Power Xpert C445 Motor Management Relay Cheat Sheets

Similar documents
Operating a Power Xpert C445 Global Motor Management Relay with a Rockwell PLC via Ethernet/IP

Power Xpert C445 Global Motor Management Relay. User Manual. Effective September 2015 New Information

User Manual. Power Xpert C445 Global Motor Management Relay

PowerXL PC Tools Eaton Corporation. All rights reserved.

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

How to Control and Monitor a C441 Motor Insight via DeviceNet

E2 Modbus RTU Register Map

MODEL CIO-EN PROGRAMMING GUIDE MODBUS/TCP, MODBUS/RTU I/O MODULE. Revision A1 Rapid City, SD, USA, 09/2008

Operating a PowerXL DC1/DE1 Drive with a Rockwell PLC on Ethernet/IP

MPU-32 ETHERNET/IP INTERFACE

Optidrive VTC Modbus RTU Register Map

DEFAULT IP ADDRESS

Softstarters. Type PSTX Fieldbus communication, Anybus Modbus TCP. 1SFC132087M0201 March SFC132087M0201 1

Safety Instruction. This symbol indicates the possibility of injury or damage to property.

C441 Ethernet Module User Manual (C441R, C441T, C441U, C441V)

3GV M Modbus RTU Register Map

Quick Start Manual G2-2 Series with Ethernet Interface

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Modbus RTU

Winsonic MODBUS Remote IO user manual Rev. 1.0

How to control and monitor up to 16 Motor Insight motor protection relays via an HMi and Modbus serial

Servo press kit YJKP - Host interface

Millenium 3 logic controllers

Communication Network. DeviceNet Communication

G5 Weighing Instrument

PRODUCT PROFILE & OUTLINE...6

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

For the configuration of the I/O-modules in a control system an EDS-file is required. The names of the files are as follows:

Before using the product, thank you for using our Ethernet module board. Safety Instruction

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

Softstarters. Type PSTX Fieldbus communication, Anybus EtherNet/IP

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Power Xpert C445 Competitive Comparison

Ethernet/IP Module. User Manual. Contents

MPS DEVICENET INTERFACE

MODEL CIO-MB, CIO-120-MB

For more information Contact with details of the application.

FnIO S-Series. FnIO MODBUS Adapter Specification Rev 1.00 NA-9473 (MODBUS/RS485) Page 1 of 30. NA-9473 (MODBUS/RS485) Adapter

6053/6055 ControlNet Communications Interface

Do-more H2 Series PLC System Specifications

Profinet Module. User Manual. Contents

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

ASTAT XB/XBm Remote Operator

MODBUS Protocol for MiCOM P30 Series

MPU-32 DEVICENET INTERFACE

Modbus User Manual APPLIED MOTION PRODUCTS, INC. Modbus is a registered trademark of Schneider Electric, licensed to the Modbus Organization, Inc.

POWR-GARD Motor Protection PGR-6200 SERIES Motor Protection System PGR-6200 DEVICENET INTERFACE

White paper. Communication with SACE Emax 2 circuit-breakers

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

ModBus Communication protocol. The ModBus protocol is an industrial communications and distributed control system

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

The RS-485 user manual for B800 series communication

SMART RELAY SRW 01 V4.0X

RS485 MODBUS Module 8AO

Additional instructions Videographic recorder LINAX DR3000. EtherNet/IP Adapter

SE-330 SERIES (NEW REVISION) ETHERNET/IP INTERFACE

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Modbus RTU. 1SFC132092M0201 June SFC132092M0201 1

Modbus Manual. ACL3200 Controller

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

ETOR-4. Ethernet/Serial Gateway USER MANUAL

Tritex II EtherNet/IP - Option

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Version Action Author Date

FnIO S Series: NA MODBUS/TCP(UDP) Adapter. with Two RJ-45

How-To. Modbus-TCP communication between CelciuX and NJ. History

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo

User Manual Gateway component for EtherNet/IP

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

LUFP7. A way to make Masterpact available on Profibus. Version /2007

7SR11 and 7SR12 Settings and Instruments

QCPort Cover Control Trouble Shooting Guide

OPERATING INSTRUCTIONS MCD

P2 Configuration Guide

MPU-32 AND FPU-32 TIA-485 NETWORK

MM200 Motor Management System

MM200 Motor Management System Communications Guide

MCW Application Notes 24 th February 2017

Connect the UMC100.3 to an Allen-Bradley PLC over EtherNet/IP using the EIU32.0

Sample F4T 32-bit Modbus RTU Packet

Operating Instructions. Modules Fieldbus

Instructions. Modbus RTU Card (WSIQ-COM-MB)

PowerXL DX-NET-ETHERNET2-2 fieldbus connection EtherNet/IP for variable frequency drive DE1/DC1

Instruction Manual Modbus Converter Unigate-CL-RS

HI 6600 series Quick Start Guide

Intelligent Technologies QCPort Cover Control

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

DNP 3.0 & Modbus SCADA INTERFACE INSTRUCTIONS FOR 205T BASED SYSTEMS

Opal Pro AB Ethernet IP. Opal Pro MS6 SERIES. AB Ethernet IP Interface Users Manual. Revision Page 1

S811 Industrial Network Integration Guide

MCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment.

ETC II Modbus Communications Protocol Reference Guide

Transcription:

SYSTEM COMPONENT REQUIREMENTS To understand the architecture and functionalities of a complete C445 Motor Management Relay system (henceforth referred to as C445), we must understand the individual components that make up the system. At a minimum, the C445 must contain at least (1) of the following components to function properly: Motor Cheat Sheets C445 REQUIRED COMPONENTS 1. (1) Measurement Module (C445M ) 2. (1) Base Control Module (C445B ) 3. (1) Communication Module (C445XC... *If Modbus RTU is not specified in the base model) 4. (1 2) RJ12 Connection cables (D77E ), required to provide power and comms from the Base Control Module to the Measurement Module and the User Interface if utilized. These must be ordered separately in the length desired. OPTIONAL ACCESSORIES 1. (1) Real-time Clock and Memory Backup Module (C445XO-RTC) 2. (1) User Interfaces (C445UM ) 3. (1) User Interface (UI) Digital Input Wiring Harnesses (C445XU ) if utilizing optional digital inputs on UI

CATALOG NUMBER SELECTION Measurement Module

CATALOG NUMBER SELECTION Base Control Module CATALOG NUMBER SELECTION User Interface Recommended is the C445UM NEMA - User Interface Nomenclature (for IEC Type, Replace - N with an I )

CATALOG NUMBER SELECTION CTs & Communication Module

COMMUNICATION Modbus Serial Port; Optional RS-485 Port If the C445 includes an RS-485 port on the Base Control Module and there is not an optional Ethernet or PROFIBUS Communication Card installed, the Modbus address and Baud Rate for this port is assigned with the DIP Switches on the Base Control Module. If an optional PROFIBUS Card is installed, the DIP Switches on the Base Control Module double as the node address for the RS-485 Modbus port and the PROFIBUS slave module. If an optional Ethernet Card is installed, the DIP Switches on the Base Control Module are dedicated to the Ethernet Card s IP address. In this case, the RS-485 port must be configured via the Power Xpert incontrol Software or via Modbus commands form a Modbus master. Note that even if there is no optional Ethernet or PROFIBUS communication card installed, the DIP Switches can be set to allow the Modbus address to be set with the configuration software. RS-485 Port - Notes Shield shall be Earthed externally Shield should NOT be connected to any of these three terminals Wiring must meet PELV requirement

COMMUNICATION - Base Control Module Dip Switches (Modbus RTU & PROFIBUS) DIP Switch settings when no optional communication card is installed in the Base Control Module, but the optional RS-485 Modbus port is included. Base Control Module DIP Switches with Built- In Modbus *** If multiple C445 devices are being utilized on the same serial network (Modbus RTU or PROFIBUS), ensure that each device has its own address and the comms parameters are consistent*** Modbus Data Rate Base Control Module DIP Switches with Ethernet Card Base Control Module DIP Switches with PROFIBUS Card

COMMUNICATION - Base Control Module Dip Switches (Modbus TCP & EtherNet/IP) When an optional Ethernet card is connected to a C445 Base Control Module, the DIP switches are dedicated to determining the IP Address of this card per the diagram above. If the C445 Base Control Module has the optional RS-485 Modbus serial port, the node address and the data rate for this port must be configured using the Web Interface or incontrol. DIP Descriptions DIP Switch 10 is reserved for future use. When switch 9 is OFF: Low Octet: DIP Switch numbers set low octet of static IP address 192.168.1.X where X is 0 253 Ethernet Port Setting Switches 1-8 are each given a value based on weighted binary. If the switch 9 is Off, the 8 lower switches are provided a value from the bottom up as follows: 1, 2, 4, 8, 16, 32, 64, and 128 respectively. Switches are On when they are toggled to the right. Add the value of all switches that are On to determine the overall value. After communication has been established, a static IP address, subnet mask, and gateway for the C445 Ethernet Card could be configure with incontrol. Example 1. Set DIP Switch 9 to OFF (left). 2. Set the bottom 2 DIP Switches 1 & 3 ON (right) and leave the others OFF resulting in a value of 5 and an IP address of 192.168.1.5 assigned to the Ethernet Card. 3. Power cycle the C445 to accept new settings. 4. Start incontrol software and go online with the C445 via Modbus TCP and the Ethernet Card. 5. Under the Communications/Ethernet categories in the incontrol, configure a static IP, subnet, and gateway. Issue a soft reset or cycle power. 6. Go offline with the C445 in incontrol. 7. Set the DIP Switches so only the following switches are ON: 2 and 9. The Ethernet Card will now be configured for NV Static IP Address. 8. Issue a soft reset or power cycle the C445. When it powers up the Ethernet Card will be configured with the static IP address, subnet mask and gateway address it was configured for with the incontrol software tool. 9. This process applies to using the USB port or the RS-485 port with the incontrol software.

COMMISSIONING TOOLS - Power Xpert incontrol - Creating a new project The default IP Address for the C445 is typically 192.168.1.254. The PC s IPv4 Address must be set to the same subnet i.e. 192.168.1.xxx to be able to communicate when utilizing Modbus TCP or EtherNet/IP and configurations will be performed within the Power Xpert incontrol environment. As previously mentioned, set DIP 9 to off and DIP 1-8 for the last Octet (1-254) per device to ensure that there will not be an IP Address conflict. Once the IP Address is configured, the device may be accessed via built-in web page or through incontrol. With incontrol, easy device configuration can be accomplished over local USB or a ModbusTCP network. The free user interface software can be downloaded from Eaton s website. As of writing this document, only the DG1 VFD and C445 devices are supported.

Once the device[s] is connected, it may be programmed and monitored from any work station over the network connection within incontrol or can be accessed on a Web Browser by simple entering the IP Address.

EATON POWER XPERT C445 GLOBAL MOTOR MANAGEMENT RELAY - USER MANUAL - MN042003EN CIP GENERIC COMMUNICATION Table 88. EtherNet/IP Object Model for the C445 Motor Page 182 Table 91. Assembly Object Class 0x4 (4) Page 184 Appendix C Optional Communication Cards Input Instance 100 (0x64): Status, Current Length = 8 Bytes Output Instance 104 (0x68): Extended Motor Starter 2 Length = 2 Bytes Page 185 Output Instance 105 (0x69): Basic Starter Relay Length = 2 Bytes Output Instance 106 (0x6A): Basic Output Control Length = 2 Bytes Page 186-187 Input Instance 107 (0x6B): Extended Overload Input w/io Length = 2 Bytes Input Instance 110 (0x6E): Status, Current, Voltage, Trip Length = 2 Bytes Page 188-191 Input Instance 116 (0x74): Full Monitoring Length = 41 Bytes Page 191-192 Input Instance 121 (0x79): Status And Short Measurements Length = 10 Bytes Page 224 Page 235-301 Table 116. Modbus TCP Function Codes Table 127. C445 Modbus Register Map User Inhibit Start/Stop (Enable Cntrl Buttons) Write "0" to Disable & "3" to Enable Local Start/Stop/Reset Data Type - DCI_DTYPE_BYTE (SINT) Line #7327 in the EDS files; Param 462 Attribute No. Class - Hex (Decimal) Object No. of Instances Description 22 0xB2 (178) BUI 1 Vendor Specific Object Number of Starts per Hour allowed before trip Write Integer to specify Allowed Starts Per Hour, RTC required Data Type - DCI_DTYPE_UINT16 (INT) Line #5871 in the EDS files; Param 371 Attribute No. Class - Hex (Decimal) Object No. of Instances Description 34 0xA2 (52) Motor Protection 1 Allowed Starts Per Hour System Services Write "6" to send a Soft Reset CMD Data Type - DCI_DTYPE_UINT8 (SINT) Line #2047 in the EDS files; Param 132 Attribute No. Class - Hex (Decimal) Object No. of Instances Description 72 0x29 (41) Control Sup. Object 1 Soft Reset Command

Read Last Fault Snap Shot Log Year, Month, Day, Minute, Hour, Second, Trip Reason, TP, Ia, Ib, Ic, Vba, Vbc, Vca, Hz, w, VA, PF, & Ground Fault RMS Line #5951-6239 in the EDS files; Param 376-394 Data Type - DCI_DTYPE_UINT8, UINT16, SINT16, & SINT32 Class: 0xA5 Instance: 0x01 Attribute: (0x1, 0x2, 0x3, 0x4, 0x5, 0x6, 0x7, 0x8, 0x9, 0xA, 0xB, 0xC, 0xD, 0xE, 0xF, 0x10, 0x11, 0x12, 0x13) Attribute No. Class - Hex (Decimal) Object No. of Instances Description See Above 0xA5 (165) Snap Shot Object 1 Fault Snap Shots Commissioning Notes!!! Eaton buckets containing a C445 User Inter & a 3-Position Switch: Local HOA MUST be in HAND (else jumper 3 to 3A) and Remote Display Unit in AUTO for Fieldbus Control. While in HAND, the Remote Display Unit can start the motor manually by deselecting the AUTO button and pressing RUN. The STOP button will stop the device in any mode. C445 Web Page & Interactive Demo may be found with the following links: Intelligent Motor Management & Protection Relay C445 Interactive Demo 1 C445 Interactive Demo 2