testo Comfort Software Basic 5

Similar documents
testo Comfort Software Basic 5 Instruction manual

testo Comfort Software Professional 4 Instruction manual

testo EasyClimate Software Instruction manual

testo Comfort Software Professional 4

testo Comfort Software Professional 4 Instruction manual

testo Saveris Adjustment software Instruction manual

testo 176 Data loggers

Software EasyKool. Instruction manual

Instruction manual. testo easyemission Software

testo 175 Data loggers Instruction manual

testo 176 Datenlogger testo 176 Data loggers testo 176 Enregistreur de données Bedienungsanleitung Instruction manual Mode d'emploi

testo Saveris Adjustment software Instruction manual

Quick Installation Guide TU-S9

testo easyheat Configuration and Analysis software Instruction manual

SYNERGY. Supervision and energy management software INSTRUCTION MANUAL

INSTALLING THE PS3 XBOX READY SOFTWARE:

Operating Manual. Windows Operating Software GSOFT 3050 as of version 3.0. for Handheld Instruments GMH 3000 / GMH 5000 / GHMsilverline

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

For ClassPad 300 PLUS. ClassPad Manager. Version 2.2 (PROGRAM-LINK TM ) User s Guide.

testo Comfort Software CFR 4 Instruction manual

TagTemp-NFC 3 TECHNICAL DATA 1 INTRODUCTION 2 MECHANICAL INSTALATION. TEMPERATURE LOGGER INSTRUCTIONS MANUAL V 1.0x D

Specifications Minimum Typical Maximum Unit

testo 184 Data logger Instruction manual

3M Molecular Detection System Software Upgrade/Installation Instructions

DIVING ASSISTANT Wersja dok: :30.00

Boxed messages as shown below need your special attention. Read them carefully.

TestAnyTime User Manual (Imaging) English Version

BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14)

Comfort software x35 Professional. Instruction manual. testo x35 Professional

SignMax software and LabelMax SP2 printer driver installation manual

3M Temperature Logger TL20/TL25 - Software Installation Guide

Book Xpress Quick Startup Guide

Sentinel AC & DC Current Logger Models SDL A401 & SDL A402

MX Sheet Version 2 Operating Manual (Introduction) -SW2DNC-SHEET-E

SartoCollect v1.0 - Installation and Run-time Instructions

Firmware Update Tool Software Program for Updating the Firmware for the SECUTEST BASE, BASE10 and PRO Test Instruments

Multichannel Data logging

U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual

User s Guide. Controller. Be sure to keep all user documentation handy for future reference.

REVISIONS * The manual number is given on the bottom left of the back cover.

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

USB driver and Software Installation. UPS Monitoring and Management Software

DRAWings 8 and Wings modular 8 Embroidery Software INSTALLATION GUIDE

DriveWizard Plus Instruction Manual

USB Temperature Logger User Guide

SmartBox System Manager 3.0 Installation Guide

9936A LogWare III. User s Guide. Revision

GX-2009 Data Logger Management Program Operator s Manual

Link 3 Battery Management Software User Guide

FX Tools Software Package - FX CommPro N2 User s Guide

Data setting software MEXE02

USB-Link Technical Guide

icms Pro USER s MANUAL Ver 1.0

Trademark. Cadex C5100 BatteryStore User Guide

INSTRUCTIONS MANUAL V2.9x B

ASSAN ESC PC Interface Software User s Guide

Connected to the FP World

Fiery Network Controller for Xerox WorkCentre 7800 Series. Welcome

STATISTICA VERSION 10 STATISTICA MONITORING AND ALERTING SERVER (MAS) INSTALLATION INSTRUCTIONS

tiptel 545/570 office tiptel 545/570 SD PC Software and Driver Installation in Windows XP/Windows 7 (32/64 Bit)

VAPOR PRO COMMUNICATIONS

PLTconnect. PLT unit software. Operating Manual

PIVOT CMS CLIENT SOFTWARE USER MANUAL

EU Driver s Hours Rules covered by Digifobpro. Table of contents

ConsolePlus (EA- SWP- PLUS) User Manual Ver. 3.2

SOFTWARE USER S GUIDE

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

Installing the VS-700 Control Surface Plug-in

Manual Lindab Analysis. PC-Software Lindab PC 410 and LT 600 for data management and online measurement with logger function. Art. n.

03 Series Data Logger Management Program Operator s Manual

UPGRADE INSTRUCTIONS

testo Sound Level Meter Instruction Manual

Thermal Transient Test Installation and Operating Manual

PS-4700/4800Series User ユーザーマニュアル Hardware Manual Manual

Installation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10

3. CONNECTION TO A PERSONAL COMPUTER

Technical Information

Table of Contents. Chapter 1 Introduction Features System Diagram... 2 Multi-Server... 2 Single-Server... 3

Thank you for purchasing Qwizdom Remotes.

USB-500 Series Getting Started Contents

KingView Quick Start Manual How to create a new project

USB Instruments EasyLogger for PS40M10 "Swordfish" Help

For ClassPad 300. ClassPad Manager. (ProgramLink) Limited Version. User s Guide. RJA

Contents. 2 Getting Started: Using HOBOware with HOBO Data Loggers

1 GB RAM USB port 1152x864 minimum screen resolution (1280x720 recommended) 15 GB of hard drive space for full install

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Setting up the PC ready for BESA 11

Dear Race Promoter: Sincerely, John M Dains Impact Software Group, Inc.

REVISIONS * The manual number is given on the bottom left of the back cover.

TAI Indicator Database User Instructions for Version 1.0

First Edition Termologger USB & OSAKA MicroLab Lite User guide

Table of Contents. Chapter 1 Introduction Features System Diagram... 3 Multi-Server... 3 Single-Server... 3

Patrol Management Online Report System

Install Manual. P2 Software ENGLISH M0509AT5091 -FJ VQT2G26-4

DataNet Installation Guide + Quick Start Guide Updated: August 2008

Epson Device Admin User s Guide NPD EN

INST.NO. INE-919. DI5000 Setting Software

KingSCADA Quick Start Manual How to create a new project

GL500A Application Manual

Measurement Software for Light Scattering Digital Dust Monitor

Transcription:

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo Comfort Software Basic 5 Instruction manual

2

1 Contents 1 Contents 1 Contents... 3 2 About this document... 4 3 Specifications... 5 3.1. Use... 5 3.2. System requirements... 5 4 First steps... 6 4.1. Downloading software... 6 4.2. Installing the software/driver... 6 4.3. Starting the software... 8 5 Using the product... 9 5.1. Start page... 9 5.2. Making settings... 9 5.3. Connect instrument... 10 5.4. Configure instrument... 12 5.5. Import measurement data... 15 5.6. Evaluate measurement data... 16 6 Tips and assistance... 18 6.1. Questions and answers... 18 3

2 About this document 2 About this document Use > Please read this documentation through carefully and familiarize yourself with the product before putting it to use. Pay particular attention to the safety instructions and warning advice in order to prevent injuries and damage to the products. > Keep this document to hand so that you can refer to it when necessary. > Hand this documentation on to any subsequent users of the product. Knowledge of Windows operating systems is required when working with the software. Symbols and writing standards Representation Explanation Note: Basic or further information. 1.... 2.... Action: more steps, the sequence must be followed. >... Action: a step or an optional step. -... Result of an action. Menu Elements of the program interface. [OK] Buttons of the program interface....... Functions/paths within a menu.... Example entries 4

3 Specifications 3 Specifications 3.1. Use The testo Comfort Software Basic 5 serves the purpose of saving, reading out and analysing individual readings and measurement series. The graphical presentation of readings is the main task of this program. Readings are measured with Test Data Loggers and transmitted to the PC via an interface. Reading out data is accomplished with the testo Comfort Software Basic 5, which activates the interfaces and provides all functions. 3.2. System requirements Operating system The software will run on the following operating systems: Windows XP ServicePack 3 (SP3) Windows Vista Windows 7 Windows 8, Windows 8 Pro, Windows 8 Enterprise Others: on request Computer The computer must meet the requirements of the corresponding operating system. The following requirements must additionally be fulfilled: Interface USB 1.1 or higher Internet Explorer 5.0 SP1 or higher min. 2 GHz CPU min. 1 GB of RAM, but 2 GB of RAM is recommended Date and time settings will be automatically accepted by the PC. The administrator must make sure that the system time is regularly compared with a reliable time source and adjusted, if necessary, to ensure authenticity of the measurement data. 5

4 First steps 4 First steps 4.1. Downloading software The testo Comfort Software Basic 5 software can be ordered on CD (article no. 0572 0580) if the download from the Internet is not desired. 1. Download testo Comfort Software Basic 5 software in the Internet free of charge at www.testo.com/download-center (registration required). 2. Save Zip file with software. 4.2. Installing the software/driver Administrator rights are required for installation. If you have already installed Comfort Software version 3.4 or 4.0, please proceed as follows: 1. Update existing software. The updates can be found at www.testo.com/download-center. 2. Install Comfort Software 5. 3. Delete instrument links from the archive and create them again via Autodect, see Comfort Software 3.4 operating instructions. 1. Select the folder in which the downloaded Zip-file was saved and unpack the Zip-file. Or 1. Insert the program CD into the CD-ROM drive of the computer. 2. Start the file Setup.exe. 3. Follow the instructions of the installation wizard. When installing under Vista, please pay attention to the following steps during the installation process: The window User account control is opened: > Click on [Next]. The window Windows Security is opened: > Choose Still install this driver software. 6

4 First steps 4. Click on [Complete] to complete the software installation. After completion of the software installation, the instrument must be connected to the PC to continue with the driver installation. 5. Use the USB-cable to connect the instrument to the PC. - The connection will be set up. - The driver installation will be executed automatically. For Windows XP: Once the software has been installed, each USB port you want to use to connect the data loggers to the PC must be enabled by the administrator: 1. Connect the data logger to the relevant USB port. 2. Install driver 175_176. > The data logger can be connected and used at the enabled USB port without administrator rights. Once Comfort Software 5 has been uninstalled, the drivers must be uninstalled manually. In some cases, the instrument driver may not be automatically recognized. In this case, continue as follows: Windows XP: - The window New hardware found is opened. 1. Choose No, not this time and click on [Next]. 2. Choose Install software automatically and click on [Next]. If the driver is not automatically found: > Enter the path to the driver: Folder Testo USB Driver. 3. Click on [Complete]. Windows Vista / Windows 7: - The window New hardware found is opened. 1. Choose Search and install driver software and click on [Next]. If the driver is not automatically found: > Choose Search computer for driver software and click on [Search]. Enter the path to the driver: Folder Testo USB Driver. - The window Windows Security is opened: 2. Choose Still install this driver software. 3. Click on [Close]. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 7

4 First steps 4.3. Starting the software Starting the Comfort software The user interface of the software is opened in the language of the operating system, if it is supported. If the language of the operating system is not supported, the user interface is in English. > Click on [Start] Programs (Windows XP) or All programs (Windows Vista, Windows 7) Testo Comfort Software. Under Windows Vista the window User account control is opened when the software is started the first time. > Click on Accept. 8

5 Using the product 5 Using the product 5.1. Start page After starting testo Comfort Software Basic 5 the start screen will appear. 1 Menu bar with status information (left) 2 Quick access with preview screen 5.2. Making settings If no instrument is connected to the software, the preview screen will show the connection page. The user interface of the software is opened in the language of the operating system if this is supported. If the operating system language is not supported, the user interface is in English. 1. Choose menu Settings. 2. Select the desired language. 3. Click on [Save]. 4. Close the software. 5. Open the software. - The user interface of the software will open in the set language. 9

5 Using the product 5.3. Connect instrument Instrument connected to PC. > Choose Connect instrument via start page or menu Instrument Select instrument. - Instruments are displayed with picture and type designation. 1 Data loggers (0572 1560, 0572 6560, 0572 1751-1754, 0572 1761-1767) only appear, if they are connected to the PC. 2 Data loggers (0563 1741, 0563 1754-1761, 0563 1771-1775, 0554 1778) appear by default each time the software is started. 3 Selection field for all data loggers (2), to choose the associated COM-Port. 10

5 Using the product For data loggers (0572 1560, 0572 6560, 0572 1751-1754, 0572 1761-1767) 1. Choose the instrument and click on [Connect]. Only one instrument can be connected at a time. - The instrument appears in the status display to the left of the menu bar. - The button [Connect] changes to [Disconnect]. - The Instrument Status is displayed. The status display only serves the purpose of information. The values cannot be edited. For data loggers (0563 1741, 0563 1754-1761, 0563 1771-1775, 0554 1778) 1. Choose the COM-Port (usually the COM-Port with the highest number, otherwise see section under "If not possible to connect"). 2. Choose the desired instrument and click on [Connect]. Only one instrument can be connected at a time. - The instrument appears in the status display to the left of the menu bar. - The button [Connect] changes to [Disconnect]. - The Instrument Show instrument status is displayed. The status display only serves the purpose of information. The values cannot be edited. If not possible to connect: Under Windows XP: 1. Choose Start Settings System control System Hardware Device manager. Under Windows Vista: 1. Choose Start System control System and maintenance Device manager. 11

5 Using the product Under Windows 7: 1. Choose Start System control System and security System Device manager. 2. Click on Connections (COM and LPT). - The entries of these categories are displayed. 3. Search for entries "Testo...", followed by a COM interface number. 4. Select this individual COM interface number in the selection field (3). 5. Click on [Connect]. The COM interface number will only remain equal if you connect the USB interface always to the same USB-port or leave it plugged in. 5.4. Configure instrument The instrument is connected with testo Comfort Software Basic 5 and is displayed in the status bar, see Connect instrument page 10. Instrument is not in Rec-mode. If necessary click on [Stop measurement]. 12

5 Using the product 1. Choose Configure operation settings via the start page or the menu Instrument Configure instrument Operation settings. 2. Make the desired settings (instrument specific) for Start criteria Start time: The instrument starts at the pre-set time. Start button on instrument: Hold [Go] depressed for longer than 3 seconds. Software start: Click on [Start measurement]. Formula: With formula start, explicit process events may become the start point of the measurement. For each measuring channel, a formula can be assigned, which can then additionally be linked by operators. The instrument will only start measuring after the limiting value of the entered formula is exceeded. The measurement will therefore only stop when the software is terminated: Click on [Stop measurement]. Stop criteria Memory full: The instrument stops the measurement as soon as the memory is full. Circular buffer memory: If the memory is full, the instrument will first overwrite the "oldest" readings. The measurement will therefore only stop when the software is terminated: Click on [Stop measurement]. Number of readings: The instrument stops the measurement as soon as the defined number of readings has been obtained. Storage cycle determines the frequency with which the readings are saved. The storage cycle must be a multiple of the measuring interval. Measuring interval determines the frequency with which the readings can be recorded and displayed (e.g. via the display). Unit determines the unit used to record and display the readings in the display. 13

5 Using the product Channel settings: Enter channel designation and limiting values. With sensors connected: Select the sensor type. With connections closed with blanking plugs: Choose switched off. With sensors connected the channel number refers to the port number printed on the instrument housing. Without assignment of the sensor type to the correct instrument port the instrument will not record any sensor readings. 3. Change to the tab Instrument configuration. 4. Enter instrument name (max. 15 characters) and description (max. 70 or 265 characters depending on the instrument), and carry out display settings. 5. Click on [Transfer to instrument]. - Configuration is completed. > If Software start has been selected as a start criterion: [Start measurement]. Template By using templates one can save the configuration settings for later instrument configurations. 1. Enter text under Choose template. 2. Click on [Save as template]. To call up a saved configuration: 1. Enter the name of the desired template into the selection field. - The saved settings are displayed. 2. Click on [Transfer to instrument]. - The settings are transferred to the data logger. 14

5 Using the product 5.5. Import measurement data From the instrument The instrument is connected to the PC and has recorded measurement data. 1. Choose Import of measurement data from the start page or via menu Evaluating Import measurement data Import measurement data. - Details concerning measurement data like instrument name, serial number and location are displayed. 2. Click on the folder icon to select the path under which the measurement data are to be saved. 3. Click on [Import]. - The screen changes to the tab Import history. - The status bar of the current import and previously performed import processes are displayed. - Once the import of measurement data has been completed the display will change to the Evaluation section. From SD-card Measurement data were copied to the SD-card, see operating instructions of the instrument. SD-card connected to PC. 1. Select menu Evaluating Evaluate measurement data. 2. Click on [Open file]. 15

5 Using the product 3. Choose SD-card. 4. Choose the file type SD Card (*.*). 5. Select the desired measurement data file. 6. Click on [Open]. - The measurement data appear in the chosen form of representation. > Save measurement data as a.vi2 file: Click [Save as]. 5.6. Evaluate measurement data Measurement data were imported, see Import measurement data Page 15. 1. Select menu Evaluate Evaluate measurement data. 1 Display of file name of the opened file. The tabs can be used for editing several series of measurement data. 2 Display of measurement data in form of diagram. 3 Display of measurement data in form of table. For the representation of alarms: Click on [Show alarms]. > Click button to expand the Diagram settings menu. 16

5 Using the product 4 Make settings for the measuring channels. 5 Make settings for the diagram. Zoom inside diagram with the mouse wheel. 6 Export selected measurement data into new report or to clipboard. 7 Print or export report. With [Print report] one can make settings to the report form, via [Start export] you use a standard report form and the file is directly saved. For the html export format, 50,000 measured values can be exported per file. For the xls export format, 65,000 measured values can be exported per worksheet and 650,000 per Excel file. If the number of measured values is above the maximum possible value per file, additional files are generated. 8 Send measurement data by e-mail: Click on [send e-mail]. The PC must have an e-mail program installed. 17

6 Tips and assistance 6 Tips and assistance 6.1. Questions and answers Question Instrument does not respond... The device cannot be connected to the software. Invalid name: The characters:!,?,*,:,\ cannot be used in location and folder names. An instrument setting with this name already exists: Please choose a new name. Possible causes / solution This message appears if the PC program cannot communicate with the connected measuring instrument or if the measuring instrument does not respond. Check whether the instrument is switched on. Check the connecting cable. Is the instrument correctly supplied with power? Is the connecting cable connected to the right COM port? Uninstall the software and the USB driver testo 175-176. Install the software under the Windows useradministrator. This user must be activated where possible for Windows Vista and Windows 7. Rename these items and do not use these special characters. Different names should be used when setting up new instruments, the same name should not be used for different instruments. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 18 TestEquipmentDepot.com