A NEW DATA LOGGER Stand alone. Secure. Fast.

Similar documents
ProfiMessage. NEW Modular. Secure. Adaptable.

The new Expert Logger 400: Industry 4.0 ready!

PRECISE STAND ALONE ADVANCED MEASUREMENT TECHNOLOGY. Innovative data logger. Modern. Powerful. Maintenance free.

Luminaire testing device

Innovative hardware...

Product catalogue 2012 / Measuring. Testing. Automation.

VersaMax Micro and Nano Technical Product Presentation

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Features and Benefits. Certifications

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

MMT330 Series Moisture and Temperature Transmitters for Oil

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

world class water monitoring series 42

COMTRAXX COM460IP. BMS-Ethernet-Gateway

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

DMT345 and DMT346 Dewpoint Transmitters

Web-enabled DAQ System

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

LAUREL ELECTRONICS, INC.

DATA LOGGER MODELS DL-1080/1081

PTU300 Combined Pressure, Humidity and Temperature Transmitter

BMS-Ethernet-Gateway COM460IP

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Pen Drive USB Datalogger!

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

RS 485 Mini Modbus 1AO

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

Q.brixx station 101. Base Unit with Test Controller. Most important features:

DATA LOGGER MODELS DL-1080/1081

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Efficient. Innovative. Sustainable.

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

General information. Display. Supply voltage. Input current. Encoder supply. Output current

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

Advanced Wind Turbine Concept. Mita-Teknik. Data Sheets. Condition Monitoring Mita-Teknik. All rights reserved

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

INSTRUCTION MANUAL V1. 2x A

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Expanding the Basic GL7000 Configuration

MIC-2 MKII, Multi-instrument DATA SHEET

RS-485 I/O Modules: ADAM-4000

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user

SHCM SMALL HYDRO CONDITION MONITORING. Web HMI (real time data, trends, spectrums, alarms )

2680 Series Data Acquisition Systems

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

PQM - Power Quality Monitoring

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

UNIVERSAL CURRENT CONVERTER

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Trident and Trident X2 Digital Process and Temperature Panel Meter

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

NF760 Batch Controller

iologik E1200H Series

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

Voltage Transducer UMT516 / MT516

Open Smart Metering Gateway EWIO-9180-M. Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

Max. I/O units. consumption

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Micro-Modular Programmable Controller

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

NOVUS AUTOMATION 1/92

Intech Micro 2400-A16-SD

MOD-MUX MODBUS TCP I/O PRODUCTS

SIGNAL CONVERTERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY. Small catalogue. Tel. (+34)

INSTRUCTION MANUAL. V1.6x F. CE Mark

Q.brixx station 101. Base Unit with Test Controller. Most important features:

MLC 9000 Bus Compatible PID

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

General information. Display. Supply voltage

Data sheet CPU 013C (013-CCF0R00)

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Redundant System Redundant System P9-1-1

INTAB FLEXIBLE SYSTEM MANUAL. INTAB INTERFACE-TEKNIK AB GJUTAREVÄGEN 1, STENKULLEN 0/103

Wall-/Pipe Mounted Universal Process Indicator

Issue 03/2013. The Electronic Load

General information. Display. Supply voltage. Input current. Encoder supply. Output current

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

Transcription:

A NEW DATA LOGGER Stand alone. Secure. Fast.

A data logger for profe Extensive functions LogMessage data loggers are universal. Whatever the application for slow or for high-speed acquisition Delphin has a LogMessage version for any user requirements. Delivery includes the ProfiSignal Go software to enable professional evaluation of online and offline data. LogMessage devices function intuitively making it easy to configure inputs, to save data, and to display data as trends. LogMessage devices are designed for permanent operation and can be depended on to perform reliably over the long term. When data security and reliability are top priorities, users choose the "Made in Germany" logger. A range of interfaces LAN interface Device configuration and online data transfer to PC Link to UMTS-routers Log memory read-out Modbus TCP for data transfer using PLC USB interface Log memory read out Serial interfaces 4 x RS232/485 Customer-specific protocols (ASCII) USB Offline LAN UMTS / Internet Universal sensor connection LogMessage devices are precision instruments that can be switched via software to function with any type of sensor. Universal use of analog inputs for ma-, mv-signals, RTDs, or any thermocouple Signal rate of 0.1 Hz to 10 khz Digital inputs suitable for up to 90 VDC Frequency inputs up to 35 khz Galvanic isolation included LogMessage devices are fully protected against earth loops enabling measurements from non-isolated sources. All analog inputs can function as differential inputs Isolation voltage between analog inputs: 110 VDC to a maximum of 650 VDC Galvanic isolation between power supply and each interface No earth loop problems Digital in/out Analog out Frequency/ Counter Thermoc

ssionals Applications Secure data acquisition with stand alone capability PC-independent measurement and testing Acquisition via universal inputs Product testing, laboratory, R&D Mobile data acquisition Fault diagnostics at machine/plant Status and event logging Energy efficiency measurements GPS data logging and remote monitoring Temperature data acquisition Online Secure data storage The LogMessage's data storage capability enables it to function without PC or network support. 3.5 GB of memory for 250 million data records Each measurement data record is recorded with a time-stamp (date and time at microsecond precision) Measurement data can be assigned to groups and used as triggers No data loss in the event of power failure Alarm management with pre and post alarm data ouples RTD 20 ma Volt/mV RS232/485 Comprehensive signal processing Software channels, configurable according to requirements, can be used for online calculation, monitoring, and many other functions. This enables data to be generated that is immediately usable. Online calculations performed on measurement data (e.g. temperature differentials) Integration functions (e.g. flows to volumes) Limit value monitoring with alarm functions (switching digital outputs) Counter function and operational data acquisition Resolutions for demanding requirements LogMessage devices are suitable for both slow- and high-speed measurements. Time resolution for analog measurement data is at 100-µs precision levels; digital resolution at millisecond precision. The devices are equipped for precision measurement with 24-Bit ADCs.

Versions LM LM LM LM LM LM LM LM LM Typ 1000 2000 3000 4000 5000 6000 7000 8000 9000 Analog input (mv, ma, thermocouple) 15 15 8 15 30 15 Analog inputs (mv, ma, thermocouples, RTD) 10 16 10 20 Analog output (mv, ma) 1 2 1 2 Digital inputs (frequency measurement) 12 (11) 24 28 (2) 12 (11) Digital outputs (mv) 17 1 5 1 16 2 Sampling rate in measurements per sec. 600 600 600 10000 80 1200 1200 600 1200 Isolation voltage DC (AI to AI) 110 110 110 100 650 110 110 110 110 LogMessage is available in nine different versions. LogMessage is a genuine high-speed logger with sampling rates of up to 10,000 measurements per second. The LM 5000 version has an increased isolation voltage of up to 650 VDC between inputs. Web server included LogMessage devices are equipped with internal web servers. The standard version displays current measurement data in a channel list as well as extensive configuration and maintenance information. In combination with the ProfiSignal WEB option, views can be generated and loaded into the LogMessage in HTML5. Software channels Software channels are capable of performing computations on online measurement data, and used for visualisation, storage or monitoring purposes. The processing of signals takes place independently within the LogMessage device and requires no PC support. There is virtually no limit on the number of software channels that can be used. Software channel computations run parallel to data acquisition and logging. Software channels are included in delivery. Online analysis Calculation channel Channel averaging Edge counter Differentiator Integrator Linearization Operating hours counter Statistic channel Stopwatch Monitoring Limit value Batch alarms Wake function Status monitoring Description Any number of channels can undergo computation procedures. Functions include: basic arithmetic functions; trigonometry; binary and boolean operations Computation of moving and triggered averages Counter for impulses (high, low, and reset functions) Computes changes over time Numerical integration over time Corrective calculations on non-linear sensors Accumulates the time (in hours) of a digital signal's high-level Computes moving and triggered statistical values (min, max, variant, standard deviation) Time measurement between two events Description Generates events for threshold violations (over- / under-runs, inertia, hysteresis, process monitoring) Generates a single alarm from multiple input channels Generates pulses at a chronological point in time (once a day, week, month ) Evaluates status information for measurement data and generates an alarm

included Quick to deploy LogMessages are delivered with the professional PCsoftware ProfiSignal Go, used for online/offline monitoring and measurement data analysis. Just three steps are required to display measurement data as trends, to analyse the data, and to evaluate offline data. ProfiSignal Go has a choice of diagrams that can be run simultaneously. The integrated DataService software provides data storage and archiving functions. In combination with ProfiSignal Go, the DataService also provides many alarm management and monitoring functions. The DataService enables ProfiSignal to function efficiently and powerfully as well as to process large data volumes via multiple and diverse interfaces. Product features Monitoring and analysis of any type of measurement data Saving experiments to individual files Online portrayal in trends Uninterrupted switching to offline data ASCII-export as CSV-file Printout or export as EMF file Offline computation functions Statistical valuation ProfiSignal Go Trend Analysis with cursor functions up to µsec Saving of diagram configuration data Evaluation of digital signal operation Included in delivery LogMessage devices are delivered with a comprehensive package of software. ProfiSignal Go LabVIEW and DASYLab drivers OPC-Server Modbus TCP OCX driver to enable self-programming +

Technical specifications Analog inputs Voltage/current measurement ranges ± 156 mv... ± 10 V / 0/4... 20 ma Thermocouples of any type; integrated temperature compensation; Sensors resistance thermometer RTD, NTC and linear resistances to 10 kω 750 VDC to the system and power supply; 650 VDC between channels for LogMessage 5000; Potential isolation 100 VDC between channels for LogMessage 4000; 110 VDC between channels for other versions 24-Bit precision V, ma 0.01 % from accumulated value; Resolution 14-Bit measurement precision: V, ma 0.1 % from accumulated value for LogMessage 4000; Pt100 0.1 K; Pt1000 0.1 K; thermocouple 0.1% from accumulated value Analog outputs Resolution / potential isolation 16-Bit / 750 V; 12-Bit for LogMessage 4000 0/4... 20 ma at a maximal max. load 650 Ω; Output signal 0... 10 V min. 2.5 kω for LogMessage 4000 Digital inputs Potential isolation 2,5 kv Input measurement range low: 0... 1.5 VDC@0... 1.5 ma / high: 3.5... 90 VDC@2 ma Frequency / counter inputs Potential isolation / measuring range 2.5 kv / low: 0... 1.5 VDC@0... 1.5 ma / high: 3.5... 90 VDC@2 ma Measurement frequency up to 30 khz at TTL-level Digital outputs Potential isolation 2,5 kv Switching voltage Data storage Standard size / measurement data Max. size / measurement data LogMessage max. 50 VDC@2.5 A Partitionable storage, standard: 3.5 GB; max. 250 million measurement records 15.5 GB; up to 1 billion measurement records; 15.5 GB; up to 7 billion measurement records for LogMessage 4000 Interfaces Mechanical design COM 1 / COM 2 RS485, 9-pole Sub-D-connector, DIN EN ISO 19245-1 Mechanical design COM 3 / COM 4 RS232, 9-pole Sub-D-plug Protocols COM 1... COM 4 Modbus RTU Master / Slave, customer-specific protocols Ethernet RJ45 (8-pole STP-connector), 100 BaseT protocol: TCP/IP, HTTP, SMTP, NTP, Modbus TCP Client / Server USB USB 1.1 for memory read out CAN 9-pole Sub-D-connector, protocols: CAN Raw; baud rates: 50 k... 1 MBaud General technical information Dimensions 200 x 73 x 118 mm Weight 1 kg Rail mounting DIN EN 50023 or screw fixings Signal connections Detachable screw terminals, 33 terminals in 2 rows, lead protection, connecting cabling max. 2.5 mm² Temperature range -20... 60 C Power supply 12... 36 VDC / 12... 28 VAC eff. / ± 10%; LogMessage 4000: 18 VAC/DC power input: < 10 Watt Layout: www.team-mt.de., 1. print 06/12 ISO 9001 certified Delphin Technology AG Lustheide 81 51427 Bergisch Gladbach. Germany Phone +49 (0) 2204 97685-0 Fax +49 (0) 2204 97685-85 info@delphin.de. www.delphin.com