The new Expert Logger 400: Industry 4.0 ready!

Similar documents
PRECISE STAND ALONE ADVANCED MEASUREMENT TECHNOLOGY. Innovative data logger. Modern. Powerful. Maintenance free.

A NEW DATA LOGGER Stand alone. Secure. Fast.

ProfiMessage. NEW Modular. Secure. Adaptable.

Luminaire testing device

Innovative hardware...

Product catalogue 2012 / Measuring. Testing. Automation.

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Remote I/O Modules EH-RIO2 Series

MMT330 Series Moisture and Temperature Transmitters for Oil

PMA Rail Line. Product Brochure.

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

VersaMax Micro and Nano Technical Product Presentation

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

VariTrans P Standard-Signal Isolators

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

w w w. z i g s e n s e. c o m. a u

X-Log Expert Data Logger

MULTICHANNEL DATA RECORDERS

iologik E1200H Series

DMT345 and DMT346 Dewpoint Transmitters

MULTICHANNEL DATA RECORDERS

RS-485 I/O Modules: ADAM-4000

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

MODEL 9250 Preliminary data sheet

TB20. DISTRIBUTED FIELDBUS I/O SYSTEM

VariTrans P The Problem The variety of tasks results in a large number of different devices.

Compact data logger offering best-in-class noise resistance and communication function

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Eurotherm advanced controllers providing solutions for simple to demanding applications...

MID approval no. DE-08-MI004-PTB004 Date of release

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

AC500-eCo: your PLC from ABB Unique scalable concept, optimal costs... Change for more!

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Q.brixx station 101. Base Unit with Test Controller. Most important features:

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

imc BUSDAQflex compact mobile expandable Intelligent multi-bus data logger for field and vehicle buses imc productive testing

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

THE NEXT TRANSDUCER GENERATION

SAI Active Universal Pro

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

LBVR1718. Description. Features channel paperless recorder

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

L-force The Lenze I/O system to IP20. Compact and modular

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Self-Powered Wireless Instrumentation

MIC-2 Multi-instrument DATA SHEET

RS 485 Mini Modbus 1AO

8B SLX300 Data Acquisition System

imc BUSDAQflex compact mobile expandable Intelligent multi-bus data logger for field and vehicle buses imc productive testing

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

enod4 Weighing controller for automated systems

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Features and Benefits. Certifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Z-PC Line REMOTE I/O SYSTEM. Cost-effective & easy to manage TCP-IP

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

MPC / 6. First interface. distance up to 15m, speed up to 19,2Kbit/s, GSM modem support. 4 band 850/900/1800/1900 MHz

TESTING SUCCESS. DATaRec 4 - DISTRIBUTED TESTING SYSTEM. ZODIAC DATA SYSTEMS GmbH AIRCRAFT SYSTEMS Data Systems

imc CANSASfit clickable small temperature resistant Robust measurement modules for mobile applications imc productive testing

Presented By. NicolScales.com Contact Us

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

Open Smart Metering Gateway EWIO-9180-M. Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

BMS-Ethernet-Gateway COM460IP

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

ELECTRONIC AND CONTROL PROCESS DEVICES. reliability. professionalism. Company Profile.

TITAN S8. Transportable Data Acquisition Device. Product Brochure EN

Pen Drive USB Datalogger!

MPC / 7. First interface. distance up to 15m, speed up to 19,2Kbit/s. 4 band 850/900/1800/1900 MHz. Second interface (galvanically isolated)

DIAGNOSTICS PN# / / FSP

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

TM221CE40R controller M IO relay Ethernet

Meter Scanner & Controller

DT9800 Series. USB Function Module for Data Acquisition

Laboratory automation

Select a Micro800 Controller

TM221M16R controller M IO relay

FLEXIBLE AND MODULAR PROCESSOR T11 MULTI I/O MODULES. The Heart of ADwin Pro-II. All-rounder with A/D, D/A, counters, SSI and EtherCAT

with Backlight Graphic LCD Screen

Measurement Systems Datascan Installation and User Guide

PI 500 Hand-held instrument for industry

M-Bus-Logger Data Logger

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Data sheet CPU 315SB/DPM (315-2AG12)

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports

Transcription:

The new Expert Logger 400: Industry 4.0 ready! NEW AND ONLY WITH US: With an OPC UA interface! Data logging Test stand automation Process monitoring

At last we have the security for measurement technology that we need for our applications. Networking, Industry 4.0, future-proof, profitability. These are the key concerns for responsible businesses especially when sensitive measurement data is involved. Nothing may be lost, everything must be securely and continuously documented, and data should be accessible every where at all times. All this is possible: with the Expert Logger from Delphin Technology. Are you aware that...... virtually everyone who experiences a live demonstration of Expert Loggers is so impressed that they then begin using them in their own companies? Data acquisition, environmental measurement technology, product testing, measurement data diagnoses, laboratory data acquisition, experiments and testing, and energy optimisation with the Expert Logger device your company is always on the safe side because it guarantees continuous recording of all relevant data. It functions independently (no network connection required) and can be operated over periods of weeks and months. Expert Logger 400 and Industry 4.0 The reality for companies is that their machinery is from different manufacturers and their plant is from different generations. This generally results in communication problems. However, this is not the case with the new Expert Logger 400. Problem free communication is guaranteed through its OPC UA interface. Even new plant and machinery can be easily integrated into existing systems. An important aspect for you is that the original Expert Logger was principally designed as a data logger. The new Expert Logger 400 is now equipped with extended monitoring functions so you get the assurance of using a tried and tested logger equipped with future-proof and advanced technology. All for one and one for all The Expert Logger is designed to match your specific requirements not the other way round. The device is built for versatility and can be set to do everything for any user. It functions perfectly as a stand alone unit or connected to the internet/ intranet. State-of-the-art communication is assured through its range of interfaces. The Expert Logger is also compact; ideal for installation in switch cabinets and in line with the motto: a smaller design means smaller costs. Delphin Technology Made in Germany As a medium-sized and established company that has been continuously developing its products for 35 years, we stand for quality, reliability, security, long-term partnerships and service. Our free of charge hotline is available with competent responses from experienced specialists. Very compact, very intelligent, and very versatile

Comments from users: Stand alone data logger Latest communication Advanced measurement technology

It uses advanced measurement technology. OPC UA enables us to now communicate overall. By using an Expert Logger you can be assured of working with the latest generation of data loggers. This means state-of-theart communication coupled with advanced technology. The new Expert Logger 400 sets you up perfectly to meet current and future requirements. The technological benefits of the Expert Logger device are as follows: it is based on FPGA technology and especially high performing; it is capable of processing up to 46 analog input channels at both low and high rates of sampling; measurement data can be accurately acquired, independently stored and transmitted to the internet or a PC via USB, LAN, WLAN and LTE for evaluation. The Expert Logger also features user-friendly operation. For example, signal connection takes place using plug-in screw terminals. Even high numbers of channels can be clearly organised. Each set of four terminals can be configured as two differential inputs to measure voltage, currents, thermocouples, or to measure a 4-wire RTD. Expert Logger types NEW Benefit 1: OPC UA interface, ProfiBus, Modbus, serial interfaces Communication 4.0 Expert Logger 400 enables communication at machine-field level via versatile interfaces Versions 100 200 300 400 Analog inputs for mv, ma and thermocouples 16 32 46 16 of which for RTD sensors Sampling rate (measurements / sec.) Digital inputs (mv, frequency) (8) (16) (23) (8) 1000 2000 3000 1000 4 4 1 1 SDI12 sensor bus 1 1 0 0 Benefit 3: Monitoring and data logging in a single device Digital outputs 4 4 1 0 Digital inputs / outputs 4 4 0 24

Flexibility WLAN interfaces to PCs and mobile devices; LAN and USB interfaces to PCs or networks Benefit 2: Stand alone operation with batteries or rechargeables Internal data memory Universal inputs Profitability The OPC UA interface enables measurement data and limit value violations to be immediately transmitted to subsystems Security Smooth, secure processes in all directions: Recording sensors controlling actuators using a single device Benefit 4: Our customers tell us It is simply a joy to work with the Expert Logger.

The integrated software is reliable and stable. And is simple to use. & Includes user-friendly software Only from Delphin Technology: ProfiSignal Go software for measurement data analysis is included with delivery. The benefits are obvious. ProfiSignal Go was also developed in-house and therefore is fully compatible with the Expert Logger and your requirements. This becomes immediately evident when using the software it is simple, intuitive, and user-friendly. For example, measurement data can be portrayed online and offline as well as analysed in detail. ProfiSignal Go can also portray all measurement data from Expert Logger devices as trends. You can choose between y(t) or y(x) diagrams as well as a range of other analysis graphics. Includes intelligent signal conditioning Signal conditioning using internal software channels significantly simplifies measurement tasks. Flexible calculation channels enable measurement data to undergo immediate computation and preprocessing. Integrators directly calculate volumes or quantities from time-weighted measurement data such as mass and discharge flow rates. Limit values can be used to monitor measurement data and switch digital outputs or automatically send emails. Complex signal processing is possible using impulse counters, stop-clock functions and operating-hour meters. Averages can be calculated and recorded as time-weighted or moving. Offline data evaluation is clear and simple. ASCII exporting of the measurement data for MS Excel, or conversion into TDM format is quick to perform. The Expert Logger s software-channel feature clearly sets it apart from other loggers and makes Delphin Technology very popular among users. Simple configuration via mouse clicking User-friendly software means simple configuration. Expert Logger configuration takes place from a PC. The configuration is saved permanently to the Expert Logger and remains there even in the event of a power loss. Configurations are easy to access from the Logger and then saved to a PC. A configuration can also be amended off-line without the Expert Logger having to be connected and then loaded into the device. You benefit by only having to perform the configuration once leaving you to focus on the actual tasks on hand.

Working with ProfiSignal Go is really enjoyable. And the telephone service provides professional help if you have a question.

Technical specifications Device Type 100 200 300 400 Analog inputs (mv, ma, TC) 16 32 46 16 Appropriate for RTD s (8) (16) (23) (8) Sampling rate 1000 Hz 2 groups per 1000 Hz 3 groups per 1000 Hz 1000 Hz Voltage / current measurement range ±156 mv.. ±10 V / 0.. 20 ma, 4.. 20 ma, free Current reference for restistance measurement None, 100 µa, 200 µa or 1 ma software switchable Strain gauge volt. ref. 5 VDC ± 10 mv 1 1 0 0 Resolution / input impendance 24 Bit / 1 GΩ Internal reference junctions yes / 2 yes / 4 yes / 6 yes / 2 Withstand voltage / galvanic isolation ±110 VDC / ±400 VDC to PE, other channel group Analog outputs 0 0 0 6 Resolution 16 Bit Output ranges 0.. 12 V / ±12 V / 0.. 20 ma / 4.. 20 ma Galvanic isolation ±400 VDC to system / PE Min. load / max. burden 625 Ω / 950 Ω Number of digital channels Digital inputs to 1 MHz 3 3 0 0 Digital inputs to 250 Hz 1 1 1 1 Digital outputs 4 4 1 0 Digital inputs / outputs 4 4 0 24 Technical information digital inputs Input signal low: 0.. 1 V / high: 5.. 100 VDC @ 3,5 ma Frequency range / width counter 0,2 Hz.. 1 MHz, respectively 0,2 Hz.. 250 Hz / 64 Bit Galvanic isolation ±400 VDC to PE, other channels Technical information digital outputs Max. switching voltage / current 50 V / 2,5 A PWM function / Pulse duty factor Basic frequency 5 Hz.. 10 khz / 1:1000 Galvanic isolation ±400 VDC to PE, other channels Data storage Data storage internal 2.. 14 GB (30 million measurement values per GB) Data storage external USB, NFS, CIFS, (S)FTP Interfaces / protocols Sensor bus SDI12 1 1 0 0 COM 1 and COM 2 RS 485, 9-pole sub-d plug / ASCII, Modbus RTU, PROFIBUS DPV1 Slave COM 3 RS 232, 9-pole sub-d plugs / ASCII, Modbus RTU LAN 1000 Base-T WLAN (alternative to WWAN) 802.11 b / g / n WWAN (alternative to WLAN) UMTS, LTE max. 100 Mbit / s USB Device 2.0 low / full / high speed / Host 2.0 low / full / high speed TCP/IP protocols (LAN, WLAN, WWAN, USB) Modbus TCP, OPC UA CAN 1 and CAN 2 CAN RAW protocols, Delphin expansion bus General technical information Dimensions / weight 210 mm x 80 mm x 125 mm / 750 g Fixing Rail mounting DIN EN 60715 or screw fixing Signal connections Plug-in screw terminals, max. 1.5 mm 2, 96 in 2 rows Temperature range -20.. 50 C Power supply 12.. 24 VDC / ±10 % Power input normal mode max. 10 W Power input sleep mode 5 mw @ 12 V, 10 mw @ 24 V NEW Edition 04/2016 Delphin Technology AG Lustheide 81 51427 Bergisch Gladbach Germany Phone +49 (0) 2204 97685-0 Fax +49 (0) 2204 97685-85 info@delphin.de www.delphin.com