NTX Series Product Comparison

Similar documents
I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

VersaMax Micro and Nano Technical Product Presentation

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

SEL-2411 Programmable Automation Controller

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Remote Terminal Unit ER1000 APPLICATION FEATURES

SCADAPack ES. Smart RTU

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

SEL-2414 Transformer Monitor

IntesisBox Modbus Server Panasonic

SCADAPack 350E 357E. Smart Remote Terminal Unit

SCADAPack ES. Smart RTU

SAGE A powerful distribution automation platform with all the functionality of a gateway. Make the most of your energy SM

icex-cmtm General specs and Installation guide

SCADAPack 312E 313E. Smart RTUs for water

SCADAPack Smart RTU

SCADAPack 530E 535E. remote Programmable Automation Controller

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

NovaTech Orion I/O Overview

SCADAPack 350E 357E. Smart Remote Terminal Units. Distributed by Relevant Solutions relevantsolutions.com

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

UK +44 (0) // USA // JAPAN //

2 NOVATECH. This page is intentionally left blank.

SCADAPack 312E 313E 314E

RTU32S RTU32S Series Small Compact Utility RTU

LAUREL ELECTRONICS, INC.

RTU32S RTU32S Series Small Compact Utility RTU

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

SCADAPack 330E 333E 334E 337E

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

DL05 CPU Specifications. Performance Contact execution (Boolean) µs Typical scan (1K Boolean) ms.

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Select a Micro800 Controller

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

High Density Switch Mainframe and Cards

Bus Bar Protection Relay B-PRO 4000

HRM-0800 Instruction Manual

Power Quality and Recording Field Upgrade Available SEL-734, Standard Power Quality, 32 MB Memory SEL-734P, Advanced Power Quality, 128 MB Memory*

JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required

GE Fanuc IC694ALG221. Rx3i PacSystem

Trident and Trident X2 Digital Process and Temperature Panel Meter

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Bedrock OSA Features and Benefits

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

MINER-S Station Controller. Substation Automation

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

C500 Series Data Sheet

Micro Motion Model 7950 and Model 7951 Signal Converters

EMS467 Monitoring System. Installation and Operations Manual Section 40

TALON Network Manager- 2 & 6 Express

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

5OOO Series. Expansion & Communication Modules. Product Selection Guide. Expansion. Communication CONTROL MICROSYSTEMS

Scout-S Station Controller

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

MINER-S Station Controller

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

PLC PFC200 Controller PFC200 CS 2ETH RS

UK +44 (0) // USA // JAPAN //

Measurement Systems Datascan Installation and User Guide

DRTS 33. The new generation of advanced three phase relay test set

IntesisBox Modbus Server Fidelio IP

RS 485 Mini Modbus 1AO

Time Counters mini "h", DC Version

ROCON RPC 116. SUBSTATION AUTOMATION Central unit for substation automation

IntesisBox Modbus Server KNX

Industrial Automation with PLC. LM MICRO SERIES PLC Selection Guide

G303 RIO (REMOTE I/O) AND LOW END RTU

TCP. Control and Protection Terminal Data sheet

DIGITAL SYSTEM. Technology Overview Nordco. All rights reserved. Rev C

Data sheet CC 03, Commander Compact (603-1CC21)

RTU560 Connections and Settings DIN Rail RTU 560CIG10

JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required

extending the boundaries of technology evolution of proven technology FEATURES

SOLUTIONS FOR AN EVOLVING WORLD RFL GARD Programmable Single Function PLC RFL GARD SFPLC 1

SCADAPack 32. Smart RTU

Accessories / 7XV5820

EM QUICK START GUIDE. Quick Start Guide EM BG0504 REV.A2

General information. Display. Supply voltage

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

DTM Distributed Transmitter Monitor

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

SCM5B. SLX200 Data Acquisition System. isolynx. Data Acquisition Systems. Visit our website Features

Modbus Server SIEMENS Algorex (printer port)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

MicroLogix 1000 Programmable Controllers

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

Features and Benefits. Certifications

Transcription:

NTX

Function Primary design application Pole-top/pad-mount switch automation; small substation installations Small substation installations with medium serial and Ethernet port requirements Some legacy ACS and 2nd source upgrade applications Medium to large substation installations, and installations with larger serial and Ethernet port requirements Some legacy ACS and 2nd source upgrade applications Small to large substation installations, with large serial and Ethernet port requirements for data concentration/integration applications. No local I/O other than for legacy ACS and 2nd source upgrade applications to adapt to legacy I/O interfaces. Very large substation or power plant installations, with very large serial and Ethernet port requirements. Heavyduty data concentration/ protocol translator applications. Some legacy upgrade applications. Replaces NTU-7575 base Fully-expanded Smaller Connex 30 Connex 60 or Connex 30 NTU-7575 and small Connex 60/Connex 30 and larger Connex 60 gateway, and smaller I/O capacity for Connex 30 data concentrator/ protocol translation applications Fully-loaded Connex 30 plus Mechanical Carrier/card file dimensions 200 x 08 x 70 mm (8 x 4.25 x 2.75 ) module 42 HP wide, 3 U high (9 w x 5.25 h x 2 d) Half card file 84 HP wide, 3 U high (9 w x 5.25 h x 2 d) Full card file 42 HP wide, 3 U high (9 w x 5.25 h x 2 d) Half card file 84 HP wide, 3 U high (9 w x 5.25 h x 2 d) Full card file Optional: 84 HP wide (9 ) for rack mounting Optional: 84 HP wide (9 ) for rack mounting Optional: front access front- or rear-mount double card file 9 w x 0.5 h x 9 d Carrier/card file mounting 35 mm DIN rail Bottom or flush surface panel Optional: front/rear access for rack 9 rack or bottom mount (front/rear module access) Bottom (front/rear module access) or rear mount (front access only) panel or optional 9 rack mount 9 rack or bottom mount (front/rear module access) or optional 9 front/rear mount double card file, front access only Expansion analog/ digital card file with separate binary output controller available No No Yes 84 HP wide, 3 U high (9 w x 5.25 h x 2 d) for large I/O installations and some upgrade scenarios; 2 I/O slots per expansion chassis DNP3/IP interfaces with built-in 2-port Ethernet switch Advanced Control Systems, Inc. 07/204 Rev 5 of 4

Power supply Mounting and input voltages available Internal 8-36 VDC (24 VDC nominal) @ 0 watts Optional: external 220 VAC/230 VDC, 5 VAC/25 VDC, 48 VDC to 24 VDC 24 VDC, 48 VDC, 25 VDC/VAC, 20 VAC, with 2 to 8 hour battery backup 24 VDC, 48 VDC, 25 VDC/VAC, 20 VAC, with 2 to 8 hour battery backup 24 VDC, 48 VDC, 25 VDC/VAC, 20 VAC, with 2 to 8 hour battery backup 24 VDC, 48 VDC, 25 VDC/VAC, 20 VAC, with 2 to 8 hour battery backup 20/230 VAC with 24 hour battery backup DC input power monitor No Yes, 00ths of volts Yes, 00ths of volts Yes, 00ths of volts Yes, 00ths of volts Base card file slot capacity Node system mid-plane MB slots 4 slots 5 slots 5 slots 8 slots I/O mid-plane MB slots 3 slots 6 slots 8 slots Expansion analog and digital card file capacity For large I/O local or distributed installations and some legacy upgrade scenarios 2 analog and/or digital input modules per card file, for a maximum of up to 92 analog, 384 binary or any combination of expansion modules per card file With separate binary output controller option, 256 control relay outputs supported per expansion chassis Includes power supply and dual 0/00 BaseT Ethernet server interfaces Expansion chassis additions limited only by DNP3/IP connectivity available (64 IP per Ethernet gateway) and the NTX gateway capacity of approximately 4,000 database points Includes board temperature monitor analog value in milli-degrees C. Advanced Control Systems, Inc. 07/204 Rev 5 2 of 4

System controller node Router/gateway maximum Isolated RS-232 or RS-485 serial ports 2 9-pin DTE 2 EIA 56 RJ45 2 EIA 56 RJ45 2 EIA 56 RJ45 2 EIA 56 RJ45 Physical 0/00 BaseT Ethernet ports Configurable Virtual Ethernet ports 7 7 7 7 7 IRIG-B time code reader (unmodulated) NMEA 083 Garmin satellite clock interface NTP supported via Ethernet Yes Yes Yes Yes Yes Database capacity 4,000 points 4,000 points 4,000 points 4,000 points 4,000 points CPU 32-bit ARM9E RISC microprocessor with DSP extensions Firmware updates USB thumb drive port to flash memory Operating system Embedded Linux (not user-accessible, for secure operating conditions) Advanced Control Systems, Inc. 07/204 Rev 5 3 of 4

PLC application supported NTX Logic Programmable Logic Controller (PLC) application that runs on the NTX System Controller platform with a Run-Time license. The NTX Logic supports all of the standard IEC 63 and IEC 6499 control program languages as well as Flow Chart. IEC 63 and IEC 6499 languages supported SFC: Sequential Function Chart FBD: Function Block Diagram LD: Ladder Diagram IL: Instruction Lists FC: Flow Chart ST: Structured Text Ethernet Quad-serial gateway node Maximum installed 3 4; no I/O; slot for control output; slot for optional expanded I/O interfaces 4; no I/O; 2 slots used for legacy I/O interfaces 7; no I/O; 2 slots used for I/O interfaces Isolated EIA 56 RJ45 RS-232 or RS-485 serial ports each 4 4 4 4 Physical Ethernet ports each Configurable Virtual Ethernet ports each 63 63 63 63 Database capacity each 4,000 points 4,000 points 4,000 points 4,000 points CPU 32-bit ARM9E RISC microprocessor with DSP extensions Operating System Embedded Linux (not user-accessible, for secure operating conditions) Board temperature monitor analog point Yes; milli-degrees C Advanced Control Systems, Inc. 07/204 Rev 5 4 of 4

Total NTX system ports supported Isolated serial ports 2 4 8; no control & DA050235 I/O controller used 8; no I/O; 2 node slots used for legacy I/O interfaces 30; no I/O; 2 node slots used for I/O interfaces Serial port baud rates Configurable from 300 to 5.2K baud per port Serial port configurations 9-pin isolated RS-232 with or without handshakes or RS-485 (4-wire); configurable per port EIA 56 RJ45 isolated RS-232 with or without handshakes or RS-485 (4-wire); configurable per port Current serial protocols supported Secondary modern (DNP3, Level 2++, Modbus RTU); legacy (Harris 6000, L&G8979, SC80, SCOMd, ACS7000). Primary (DNP3; Level 2++, Modbus RTU, Cooper 279) IED protocols supported Configurable per port (F/W PO5-009) Secondary modern (DNP3, Level 2++, Modbus RTU); legacy (Harris 6000, L&G8979, SC80, SCOMd, ACS7000) Primary (DNP3; Level 2++, Modbus RTU, Cooper 279) IED protocols supported Configurable per port (F/W PO5-0098 and PO5-005) Additional Ethernet/quad serial gateways can support L&N Conitel secondary C2020 and C300 (with SOE) protocols (F/W PO5-006) and a special Detroit Edison Protocol Suite (PO5-0094) Analog modem support Bell 202 external modem Bell 202 modem; 2-wire or 4-wire communications interfaces with optical isolated Transmit Key (PTT) output Uses one analog or digital input module slot Physical 0/00 BaseT Ethernet ports 4 5; no control & DA050235 I/O controller used 5; no I/O 8; no I/O Virtual Ethernet ports 7 96 259 259 448 IP protocols supported DNP3, Level 2++ and Modbus RTU client, server or multiples of both Advanced Control Systems, Inc. 07/204 Rev 5 5 of 4

Local binary inputs supported Binary contact inputs maximum Base 6 plus 4 expansion binary input modules, DIN rail-mounted (groups of 8 inputs each) 48 points maximum Isolated 8-36 VDC contact wetting With DA050230 I/O controller Maximum of 3 slots (96 points maximum with no analog inputs) Isolated 24 VDC contact wetting Use for legacy ACS and 2nd source upgrades where local I/O slots can be used for analog, digital inputs or required Bell 202 modems With DA050235 I/O controller 32 point binary input modules, card file mounted Maximum of 6 slots (92 points maximum with no analog inputs) Isolated 24 VDC contact wetting Use for legacy ACS and 2nd source upgrades where local I/O slots can be used for analog, digital inputs or required Bell 202 modems Advanced Control Systems, Inc. 07/204 Rev 5 6 of 4

Local binary inputs supported (continued) With DA05020 I/O controller Can be used for legacy upgrades where base I/O slots can be used for any required Bell 202 modems Can support 3 internal card file or external card file modules, but not both at the same time Supports ACS DIN rail binary modules with up to 8 modules (256 points) binary modules only with up to 6 modules (52 points) supported Includes board temperature monitor analog value in milli-degrees C Can be used for legacy upgrades or very large I/O installations Can support 6 internal card file or external card file modules, but not both at the same time Supports ACS DIN-rail binary modules with up to 8 modules (256 points) 32 point binary input modules : maximum of 6 modules (52 points) Includes board temperature monitor analog value in milli-degrees C For legacy ACS or 2nd source upgrades Can support external card file modules Can support maximum of 52 binary input points Can support a maximum of 256 binary inputs using ACS DIN rail binary input modules Includes board temperature monitor analog value in millidegrees C Can be used for legacy upgrades or very large I/O installations Can support 8 internal card file or external card file modules, but not both at the same time Supports ACS DIN rail binary input modules with up to 8 32-point binary input modules (256 points) : maximum of 6 modules (52 points) Includes board temperature monitor analog value in milli-degrees C Maximum inputs with expansion card file(s) Large I/O installations and legacy ACS or 2nd source upgrades may require expansion card files, with up to 384 binary input points maximum per expansion chassis (2 I/O slots each) Multiple expansion card files supported Uses the DA05020 I/O controller for the interface to the installed I/O modules and DA05022/DA0502 termination for the 0/00 BaseT Ethernet connectivity to an NTX Gateway Ethernet port Includes board temperature monitor analog value in milli-degrees C Advanced Control Systems, Inc. 07/204 Rev 5 7 of 4

Local binary inputs supported (continued) Optional contact wetting Optional externally supplied 48/30 VDC contact wetting with external dropping resistors Optional externally supplied 24/48/30 VDC contact wetting with external DIN mounted terminal block module, DA04032 Optional externally supplied 24/48/30 VDC contact wetting with external DIN mounted terminal block modules, DA04032 Legacy ACS or 2nd source upgrades will use existing digital input contact wetting Optional externally supplied 24/48/30 VDC contact wetting with external DIN mounted terminal block module, DA04032 Includes second layer of optical isolation with all binary inputs fully bi-polar Includes second layer of optional isolation with all binary inputs fully bi-polar Includes second layer of optical isolation with all binary inputs fully bi-polar Removable compression terminal blocks for up to #2 AWG wire Removable compression terminal blocks for up to #2 AWG wire Removable compression terminal blocks for up to #2 AWG wire Standard customer terminations DIN rail module and expansion module compression terminal blocks modules: DIN railmounted external terminal block module; per 6 digital inputs Includes LED contact state indicators for each input point modules: DIN railmounted external terminal block module; per 6 digital inputs Includes LED contact state indicators for each input point Legacy ACS or 2nd source upgrades will use existing I/O terminations modules: DIN railmounted external terminal block module; per 6 digital inputs Includes LED contact state indicators for each input point Input current limits 8 ma closed contact; <4 ma open contact 8 ma closed contact; <4 ma open contact 8 ma closed contact; <4 ma open contact Will use existing legacy I/O terminations 8 ma closed contact; <4 ma open contact Input isolation Optically isolated Optically isolated Optically isolated Will use existing legacy I/O terminations Optically isolated Binary inputs, configurable per point Binary Form A or Form C counters Binary with time (SOE ), binary without time (Status), or Form A or two consecutive as Form C counters Protocol dependent if supported Configurable for count per contact transition or count per contact full cycle Default: count per contact transition Advanced Control Systems, Inc. 07/204 Rev 5 8 of 4

Local binary inputs supported (continued) Binary input debounce filter Fixed debounce filter; changed contact must be in the same state for 4 consecutive millisecond scans before declaring the point change Adjustable bounce filter; changed contact must be in the same state for configurable (0-25) consecutive millisecond scans before declaring the point change on a per point basis Default: 5 Ms Binary input chatter filter If enabled, provides a chatter period of 0 to 65535 milliseconds and a chatter filter change limit of to 32 changes Both configurable on a per point basis Default: disabled Binary input sense mode Non-invert or invert on a per point basis Default: non-invert Binary input scan period & event resolution millisecond Change buffers 256 events Local DC analog inputs supported DC analog inputs maximum 6 expansion DC analog input modules 35 mm DIN rail-mounted (groups of 6 inputs each) 36 points maximum With DA050230 I/O controller 6 DC analog input modules, card file mounted Maximum of 3 slots (groups of 6 inputs each; 48 points maximum with no binary inputs) Advanced Control Systems, Inc. 07/204 Rev 5 9 of 4

Local DC analog inputs supported (continued) With DA050235 I/O controller 6 DC analog input modules, card file mounted Maximum of 6 slots (groups of 6 inputs each; 96 points maximum with no binary input points) With DA05020 I/O controller Can be used for legacy upgrades where base I/O slots can be used for any required Bell 202 modems. Can support internal card file or external card file modules, but not both at the same time Up to 6 DIN mounted or card file mounted modules (256 points) supported Includes board temperature monitor analog value in millidegrees C Can be used for legacy upgrades or very large I/O installations The base 6 I/O slots can be used for any required I/O or Bell 202 modems Can support internal card file or external card file modules, but not both at the same time 6 point analog input modules Maximum of 6 DIN mounted or card file mounted modules (256 points) supported Includes board temperature monitor analog value in milli-degrees C Can be used for legacy upgrades Can support a maximum of 256 DIN rail or card file analog input points Includes board temperature monitor analog value in millidegrees C Can be used for legacy upgrades or very large I/O installations The base 8 I/O slots can be used for any required I/O or Bell 202 modems Can support internal card file or external card file modules, but not both at the same time 6 point analog input modules Maximum of 6 DIN or card file mounted modules (256 points) supported Includes board temperature monitor analog value in milli-degrees C Maximum inputs with expansion card file(s) Large I/O installations and legacy ACS or 2nd source upgrades may require expansion card files with up to 92 points maximum supported per expansion chassis (2 I/O slots each). Uses the DA05020 I/O controller for the interface to the installed I/O modules and also DA05022/DA0502 termination module for the 0/00 Base T Ethernet connectivity to an NTX Gateway Ethernet port. Includes board temperature monitor analog value in milli-degrees C Advanced Control Systems, Inc. 07/204 Rev 5 0 of 4

Local DC analog inputs supported (continued) Standard customer terminations Analog input expansion module compression terminal blocks modules: 35 mm DIN rail-mounted; external compression terminal block module ( per 8 analog inputs) modules: 35 mm DIN rail-mounted external compression terminal block module ( per 8 analog inputs) Legacy ACS or 2nd source upgrades will use existing I/O terminations modules: 35 mm DIN rail-mounted external compression terminal block module ( per 8 analog inputs) Standard input range 0 ± ma 0 ± ma 0 ± ma 0 ± ma 0 ± ma Optional input ranges 4-20 ma, 0 ±.5 ma, 0 ± 2 ma, 0 ± 5 VDC, etc. 4-20 ma, 0 ±.5 ma, 0 ± 2 ma, 0 ± 5 VDC, etc. 4-20 ma, 0 ±.5 ma, 0 ± 2 ma, 0 ± 5 VDC, etc. 4-20 ma, 0 ±.5 ma, 0 ± 2 ma, 0 ± 5 VDC, etc. 4-20 ma, 0 ±.5 ma, 0 ± 2 ma, 0 ± 5 VDC, etc. A/D resolution 6-bit 6-bit 6-bit 6-bit 6-bit Supports scaling to engineering units Yes, with 32-bit floating point calculations of FSEU/32767 ± offset Yes, with 32-bit floating point calculations of FSEU/32767 ± offset Yes, with 32-bit floating point calculations of FSEU/32767 ± offset Yes, with 32-bit floating point calculations of FSEU/32767 ± offset Analog Accuracy 0.%; -0 C to 70 C (4 F to 58 F) 0.%; -0 C to 70 C (4 F to 58 F) 0.%; -0 C to 70 C (4 F to 58 F) 0.%; -0 C to 70 C (4 F to 58 F) 0.%; -0 C to 70 C (4 F to 58 F) Multiplexing hardware Differential - all solid-state (CMOS FET) Differential - all solid-state (CMOS FET) Differential - all solid-state (CMOS FET) Differential - all solid-state (CMOS FET) Differential - all solid-state (CMOS FET) Common mode rejection 85 db @ 0 to 60 Hz 85 db @ 0 to 60 Hz 85 db @ 0 to 60 Hz 85 db @ 0 to 60 Hz 85 db @ 0 to 60 Hz Normal mode rejection >70 db @ 60 Hz >70 db @ 60 Hz >70 db @ 60 Hz >70 db @ 60 Hz >70 db @ 60 Hz Isolation between inputs 0 m Ω 0 m Ω 0 m Ω 0 m Ω 0 m Ω Advanced Control Systems, Inc. 07/204 Rev 5 of 4

Local DC analog outputs supported DC analog outputs maximum 2 DC analog output modules, 35 mm DIN railmounted (requires booster 5 VDC logic supply) 4 DC analog output modules, 35 mm DIN rail-mounted 8 DC analog output modules, 35 mm DIN rail-mounted 8 DC analog output modules, 35 mm DIN rail-mounted 8 to 6 DC analog output modules, 35 mm DIN rail-mounted DC analog output range Isolated 4-20 ma per module/channel Isolation Galvanic D/A resolution 6-bit Output impedance 25 m Ω Analog accuracy 0.%; -0 C to 70 C (4 F to 58 F) Local control outputs supported SBO relay capacity 24 24 256 relays (less one quad-gateway) With DA050240 output controller 256 relays (less one quad-gateway) and for legacy RTU control interfaces Can be equipped with more than output controller Momentary relay module contact types (DIN railand panel-mounted) 4 relays each, one Form X @ 0 amp, 50 VDC; 8 relays each with one Form A and one Form B @ 0 amp, 32 VDC/277 VAC or 8 relays each with one Form C @ 5 amp, 32 VDC/277 VAC 6 relays each, one Form X or two Form C @ 20 amp, 50 VDC; 8 relays each, one Form X @ 0 amp, 50 VDC; 6 relays each, one Form A and one Form B @ 0 amps, 32 VDC/277 VAC Latch relay module contact types (DIN rail-mounted) 4 relays each, one Form C @ 0 amp, 32 VDC/277 VAC (2 addresses per relay) 8 relays each, one Form C @ 0 amp, 32 VDC/277 VAC (2 addresses per relay) External local/ remote switch Removable jumpers; optional external switch Built into card file rear panel or termination module Advanced Control Systems, Inc. 07/204 Rev 5 2 of 4

Local control outputs supported (continued) Relay coil voltage 24 VDC using optically isolated high-current drivers Control sequence Internal select-before-operate Control flags available Enclosures available Control system enable, control system failed Binary output controller on-line, X output error, Y output error, control system busy, local mode Enclosures and ratings Various sizes NEMA 2 (indoor) and NEMA 4 (outdoor) cabinets Floor mounting or wall mounting with rear-access only available Mounting 35 mm DIN rail Bottom card file (with module removal clearance), flush/semiflush through panel or 9 rack/wall cabinet mounting DIN rail-mounted analog and digital input terminal block modules, control output modules, and analog output modules external to card file 9 rack mounting or bottom card file panel mounting (with module removal clearance) DIN rail-mounted analog and digital input terminal block modules, control output modules, and analog output modules external to card file Bottom front/rear access card file (with module removal clearance) or front only card file rear panel mounting Optional 9 rack mounted 9 rack mounting or bottom card file panel mounting (with front DIN rail-mounted analog and digital input terminal block modules, control output modules, and analog output modules external to card file I/O protection certifications Input voltage Internal noise <.5% of input voltage (certified to IEEE Standard C37.-994) Input voltage range > ± 5% of nominal Inputs and outputs IEEE SWC protected (certified to ANSI/IEEE C37.90.-2002) Impulse voltage protected (certified to IEC 255-5 Standards) Advanced Control Systems, Inc. 07/204 Rev 5 3 of 4

Environmental specifications Operating temperature -0 C to 70 C (4 F to 58 F) With heater option To -30 C (-22 F) Humidity 0% to 95% non-condensing NTX Explorer configuration/monitor software Platform Microsoft Windows (XP/WIN7/WIN8 with administration rights) Accessibility File transfer from the PC to the NTX, or from the NTX to the PC via a micro-usb serial connection to the NTX USB maintenance port Where permitted, via the Ethernet WAN User interface Keyboard and mouse-driven menus and views emulate Microsoft Windows Explorer PC serial interface Mini-USB to USB interface port cable Firmware updates USB thumb drive port Monitor parameters Input and output state/values; control relay or IED tests, selective tracing of internal network traffic Manually modify analog, counter or binary data values for on-line simulation testing of all inputs On-line IED communications statistics Customer-enabled for either local or remote WAN access (can be disabled) Advanced Control Systems, Inc. 07/204 Rev 5 4 of 4