BMS: Installation Manual v2.x - Documentation

Similar documents
BMS: Configuration Manual v2.x

LO-LED64 Latched Output Card

DSP240-LPI Inverter Controller Card. Technical Brief

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

Home Security System with Remote Home Automation Control

AIC1520. Ferrite Bead GND. *33µF, 16V Tantalum, or 100µF, 10V Electrolytic Bold line indicate high-current traces. USB High-Side Power Switch

Ocean Controls KTA-224 Modbus IO Module

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

BENCHMARK MEDIA SYSTEMS, INC.

UCBB dual port breakout board user's manual

Universal Keying Adapter 3+

Display Unit User Manual

Thursday, September 15, electronic components

P522 Signal Processor

Genset Controller Unit Model EMS - GC10. Installation Manual Section

USER S MANUAL. C32- DUAL PORT MULTIFUNCTION CNC BOARD Rev. 4

INSTALLATION INSTRUCTIONS

Appendix F: Design Documentation for multisensory therapy system

Energy Management System. Operation and Installation Manual

Adafruit USB Power Gauge Mini-Kit

Perform general SC916 electrical testing. With external power removed, step on one or both of the pedal arms

Issue : 1.1 Date : 19/1/2004. Trigger IO. C-Cam Technologies. a division of. Vector International 1 / 6

Integrated Battery Control System LBCS Step-by-Step Setup Guide

MaxStepper Serial Step and Direction Pulse Generator. User Manual

Slick Line Acquisition System Manual

RFID: Read and Display V2010. Version 1.1. Sept Cytron Technologies Sdn. Bhd.

EMUS BMS mini User Manual v0.8

MP6500 Stepper Motor Driver, Digital Current Control

Basic Interface Techniques for the CRD155B

DEV-1 HamStack Development Board

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

DREAM 2 WIRED RTU SYSTEM GUIDE

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

C11G- MULTIFUNTCION CNC BOARD Rev. 8.2

LVX Control Unit. Features:

Comprehensive support USB hot-swappable, USB connection at any time to monitor the state, Mach3 work

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

PANDORA HACKER GUIDE

UNIPORT V2. Uniport V2

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

C35- QUICK SETUP BREAKOUT BOARD Rev. 1.1

BERMAD Irrigation. BIC Wire RTU

eace PLC Velocio s Embedded Ace (eace) PLC

What are output transducers An output transducer will convert electrical signals passed to it by the process into another form of energy.

Measurement Systems Datascan Installation and User Guide

POWERWISE INDAC SETUP MANUAL

USER S MANUAL. C11S- MULTIFUNTCION CNC BOARD Rev. 1.2

Digital Pins and Constants

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

Two Door Controller GEN-045

E3B USER'S GUIDE. for QT310 / QT320 QProx IC evaluation and development Overview. Fast Start

UC-2000 Installation Manual Unicorn Computers Technology Limited

Abstract. GLV User Manual 1

- NLS NAVIGATION LIGHT CONTROL

Hardware Manual 1240i-485

Owner s Hardware Service Manual Frank Control Computer System

ZeptoBit Isolated USB-UART Adapter Datasheet

I/O System for the PSYONIC Advanced Bionic Hand. Team 28 Byron Hopps and Steven Sun ECE 445 Senior Design Fall 2017

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM

DATA LOGGER GEOLOGGER G8 PLUS

USER S MANUAL. C33 - MULTIFUNCTION ROUTER BOARD BOARD Rev. 4

Electronic Control Unit RC

High Voltage Battery Management System. Installation Guide , Rev. 1.8

EVALUATION KIT AVAILABLE 28V Linear Li+ Battery Charger with Smart Autoboot Assistant OFF

Setting up an initial ".tcshrc" file

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

icex-cmtm General specs and Installation guide

TLE9869 Eval.Kit V1.0 Users Manual

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

AIC1526. Dual USB High-Side Power Switch FEATURES DESCRIPTION APPLICATIONS

Goal: We want to build an autonomous vehicle (robot)

Installation & Operation Guide

With a digital input we can read two states, a high or low. A switch can be open or closed.

CRADLEPOINT GPIO APP NOTE AFFECTED PRODUCTS: COR IBR11X0 FAMILY, COR IBR9X0 FAMILY, COR IBR6X0 FAMILY, COR IBR6X0B FAMILY, COR IBR6X0C FAMILY

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

C33- MULTIFUNCTION ROUTER BOARD Rev. 2

Laboratory of Sensors Engineering Sciences 9 CFU

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

CORRIGENDUM ISSUED FOR NATIONAL COMPETITIVE BIDDING UNDER TEQIP PHASE-II

HM9708 HM9708. Battery-Powered Equipment Motherboard USB Power Switch USB Device Power Switch Hot-Plug Power Supplies Battery-Charger Circuits DC+ VIN

AG300 Family CTL01-3A-03, AMP01-2A-02

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

ElectronFlux USB Module

DECK All-In-One Enclosure. Quick Installation Guide for Field Installers

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

RS 485 Mini Modbus 1AO

IST ULTRASTAB Power Supply for high precision transducers

T100MD PLC Installation Guide

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

DM9051NP Layout Guide

Linux Kernel Hacking Free Course, 3rd edition. HWMPS: Hardware Monitor & Protection System

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

USER S MANUAL. C11- MULTIFUNTCION CNC BOARD Rev. 9.9

CH1. Figure 1: M3 LOG Advanced

Electric Vehicle Display

Plug in to external instrument, lamp or buzzer

Transcription:

Page 1 of 7 BMS: Installation Manual v2.x From Documentation This section describes how external peripheral devices are connected and additional functions of the BMS are used. I you have not done so already, please follow Quick Start Guide to get your system running before proceeding further. Contents 1 Before you start 2 Bluetooh module 3 Current Sensor 4 CAN Cell Group Modules 5 Charging and Battery low indication 6 Sound buzzer 7 Ignition and Fast charge input switches 8 Charger 8.1 Connecting non-can charger 8.2 CAN charger 9 Display unit 9.1 EVGUI for Windows Mobile OS 9.2 EVGUI for Android OS 9.3 Fuel Gauge Display 9.3.1 Digital Fuel Gauge 9.3.2 Analog Fuel Gauge Before you start Emus BMS Control Unit has several inputs and outputs, some of them are fixed and some can be remapped in software: The internal circuitry of the pins is shown below. Different types of pins have different circuitry and properties. For example, output pins (BUZZER, HEATER,...) are controlled by MOSFET open drain and can only be configured for output functions, but they can drive loads with up to 0.5A current to the ground. Other pins have protective resistors and external devices may be driven only with small currents (0.5mA). All pins are controlled by internal Micro Controller Unit (MCU) with CMOS 0-5V level signals for inputs and outputs. On the pins where there are 10k resistors and clamping diodes the inputs may be driven with signals above +5V and applying +12V signal is fully acceptable. BMS Control Unit interface pins internal schematic fragments

Page 2 of 7 Emus BMS typical wiring diagram Bluetooh module Emus Bluetooth module operates from 12V supply and communicates with Emus Control Unit via RS232 port (DISP.TX and DISP.RX pins). Connection is as follows: 1. 2. 3. 4. 5. Black - 0V Red - +12V White - DISP.RX Green - DISP.TX Shield - not connected. Pairing password: 1234 Please note that RS232 port is shared with USB port internally: Bluetooth will be not accessible while USB is connected. Bluetooth module can be powered from ignition key, if energy saving is required.

Page 3 of 7 Current Sensor Emus current sensor is plug&play, but requires some configuration. Sensor has two hall-effect chips to provide two measurement ranges: 0-100A and 100-1000A. At high loads second range is used and on lower loads - more sensitive (0-100A) range, to get more accuracy. Typical accuracy for Emus Current Sensor is 0.5%. Each Current Sensor is calibrated at factory and calibration values are written on back of the sensor - these should be entered in the configuration of Emus Control Unit via Emus Control Panel software. Also make sure that Control Unit's INPUT1..INPUT4 pins are mapped for Current Sensor. The Current Sensor can be mounted either way, as it will simply show current with plus or minus sign. It can be inverted in configuration. Hall-effect chips are sensitive to magnetic fields, so current sensor should be zeroed-out after install. Current sensor comes with 4 meter twisted-pair shielded cable and Control Unit connector. As with all low-signal cables, it is recommended to instal this cable far from power cables. If it is installed in a car for example, power and signal lines should go on different sides. CAN Cell Group Modules Emus CAN Group Module is used as an interconnecting interface to separate the whole battery pack into cell groups. Each group of cells is served by one Emus CAN Group Module which then communicates to Emus BMS Control Unit via CAN bus. This arrangement allows better communication reliability in installations where EMI levels could pose issues for simple serial connection. CAN group modules should also be used if the whole battery pack's cells are installed in physically separate locations where EMI would likely cause communication interference errors over long single wire connecting Emus Cell Modules. CAN Group Module has optical embedded isolation circuitry so it may be connected directly to Cell Modules chain without additional isolation modules. CAN Group Module also allows to form exchangeable modules of battery pack. Optical isolation allows to build exchangeable modules each having safe voltage levels for manual handling. Please note that CAN Group Module still requires Emus BMS Control Unit to perform BMS functions.

Page 4 of 7 CAN Cell Group Modules also serves another purpose of giving the possibility of arranging the cell groups intro several strings of cells connected in parallel, for applications that require more power with the same voltage. Charging and Battery low indication These are basic signals for user, if graphical display is not used. There are two outputs for indication lamps Charging Indication and Battery Low. The outputs are pulled low to the ground when active. The Emus Control Unit's outputs for lamps can provide up to 0.5 A current which allows to use up to 6W 12V lamps. Lamp's one terminal must be connected to Emus BMS Control Unit's output and the other side must be connected to +12V external power source. The source could be the same as supplying the power to BMS. LEDs can also be used but they must be connected with corresponding value resistor in series (820 Ω typically). Sound buzzer The warning buzzer must be of self-oscillating type which emits a sound of some warning frequency when it is connected to power source of 12V. The output is pulled low to the ground when active. Buzzer's (-) terminal must be connected to Control Unit's BUZZER output. Buzzer's (+) terminal must be connected to +12V power source. The buzzer may draw up to 0.5 A current maximum. Ignition and Fast charge input switches EMUS BMS inputs IGN. IN and FAST CHG. are activated by positive +12V signals. IGN. IN should be connected to vehicle's ignition key switch which supplies +12V when active. This input informs the EMUS BMS when the vehicle is being actively used. FAST CHG. should be connected to two position switch which is supplying +12V when fast charging mode is selected. Charger Emus BMS supports two types of chargers: basic and CAN-equipped chargers. CAN-equipped chargers are able to be controlled and configured over CAN line. Connecting non-can charger Non-CAN charger does not have the benefits of CAN charger but may also be used with EMUS BMS. There are two signals provisioned for such charger connection: AC SENSE and CHARGER. AC SENSE is the input which senses the charger connection to AC mains power source. +12V voltage applied on this input informs BMS that charger was connected to AC mains socket and charging can start. CHARGER is the output controlling the charger. It is pulled low to the ground when active. It may drive charger's input or a relay which is connecting the AC power source to charger's input.

Page 5 of 7 An optional specially designed opto-isolated AC sensing non-can charger control relay can be ordered from JSC Elektromotus. This relay connects to AC SENSE and CHARGER signals on low voltage side. On high voltage side it connects to AC mains source and charger's AC input. Relay cable colors: Red - goes to BMS Control Unit "+12V", White - goes to BMS Control Unit "AC SENSE", Green - goes to BMS Control Unit "Charger", Black/chield - not connected. CAN charger Before connecting CAN charger a correct charger model must be selected in Charger Type field via EMUS BMS Control Panel application on PC. The connection to CAN charger is made by connecting EMUS BMS Control Unit's CAN+ and CAN- signals to corresponding charger's CAN interface signals. Resistive termination is required for reliable operation of CAN interface. EMUS BMS Control Unit does not have internal terminator between CAN+ and CAN- signals. If charger does not have internal termination then external 120 Ohm termination resistor must be connected between CAN + and - signals. The 120 Ohm termination resistor is included in the EMUS BMS package. Once the CAN charger is properly connected to Control Unit via CAN bus it may be verified by plugging it into AC mains. EMUS BMS Control Unit will detect the powered-up charger via CAN bus and start a charging process which can be checked by Charging Indication lamp, graphical display or via EMUS BMS Control Panel application on PC. Display unit EMUS BMS Control Unit sends its output parameters via serial RS232 interface. The data can be used for detailed display of BMS operation details via graphical user interface using various graphical handheld devices, such as ipaq Pocket PC with Windows Mobile OS. EVGUI for Windows Mobile OS Free open-source EVGUI software for Windows Mobile handheld devices is available on Downloads page. Devices of various series which have serial interface of Bluetooth connection and are running Windows Mobile operating system can be used. Software is currently available for ARM processor platform based devices but will be expanded in the near future. Please follow updates in News section. When connecting devices the EMUS BMS Control Unit's DISP. TX should be connected to device RX data line and DISP. RX should be connected to IPAQ s TX data line. EVGUI for Windows Mobile OS data layout

Page 6 of 7 EVGUI for Android OS Free open-source software Android EVGUI for handheld devices is available on Downloads page. Please follow updates in News section. Fuel Gauge Display Fuel gauges come in various shapes and signal types, analog or digital. Control Unit's "SOC OUT" pin is designed with versatility in mind: pin is internally connected directly to MCU via 1kΩ resistor, thus giving protected pulse-width-modulated CMOS 0-5V level signal. This allows it to be used with various Fuel Gauges, however, requires some additional Gauge-specific circuitry. Digital Fuel Gauge In case of digital gauge, which accepts pulsed PWM signal, no additional circuitry is needed and the gauge can be wired directly to SOC OUT pin. Analog Fuel Gauge Probably the most popular ones, as shown on this picture, have three terminals: 0V, +12V and "input". "0V" terminal should be connected to Control Unit's GROUND, "+12V" - to ignition key. The "input" terminal usually is pulled down to GROUND to indicate "full tank" and left open for "empty tank". To interface it to this kind of gauge, current amplifier is needed: N-channel MOSFET, NPN BJT or optocouple usually does the job. Other types of analog fuel gauges

Page 7 of 7 may not work properly with pulsed PWM signal and will need filtering Standard fuel gauge and, sometimes, amplification. One type of gauges requires a 0-5V DC signal. In this case, since there is an internal 1kΩ resistor, only a 10µF capacitor is needed between SOC OUT and GROUND. It will filter-out the pulses and leave a DC voltage, which is proportional to pulse width. Retrieved from "" This page was last modified on 5 March 2013, at 13:10. This page has been accessed 9,683 times.