eyeheight EM-4 AES audio option for playout user manual

Similar documents
Fastrack Release Notes Version 3.5X60

D/ESAM Installation Guide

User Manual Controller. Automation and Router Control.

C8651 C8000. digital audio modular processing system. Dolby Medatada serial RS485 I/O. features. functional description. page 1/7

Quick Start Guide. Installation Summary

Quick Start Guide. Installation Summary

N8VEM S-100 BACKPLANE VERSION 04 MAY 3, 2015 J.B.

AMU1-CHD+MK2 AUDIO MONITORING UNIT

Digital Mixing System D-2000 Series

PMC494 10BaseT to 10Base2 PMC Media Converter

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

The AMG5715A1B9 is designed to be powered using an AMG2001 standalone power supply.

Unpacking an Epica Distribution Matrix

CORIO matrix by Modular AV router with softswitching & scaling. CORIOgraph your video

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring

TruZoom and Corvid Ultra 4K/UHD Region of Interest selection, Live Scaling and Recording

Installation Instructions Model ZAM-180

8 Channel Video Transmit Unit with 9 Bi-directional Data and Audio Channels and Ethernet for a Multimode Fibre Link

Network Video Recorder Quick Operation Guide

Data Insert Unit with 2 Bi-directional Data Channels for a Dual Redundant Singlemode Fibre Ring

The Shop Interface Unit allows MxPro 4 control panels to send and receive alarm signals from other equipment.

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

WR-5e Remote Control

OPEN SOURCE SPECIFICATION

Quick Start Installation Guide

Installation Guide Serial Interface T942SI

BT-1 Series Bluetooth Wireless Audio Module

MIXERS. 6 channel dual format DJ mixer with removable fader panel. (Supplied with linear faders)

MIXERS. 6 channel dual format DJ mixer with removable fader panel. (Supplied with linear faders)

Digital Keypad Introduction

TABLE OF CONTENTS 1. OVERVIEW... 1

C S Technology Ltd. cstech.co.uk. DTMF display 32 kit with 2 line x 16 LCD display

Installing Sentor. Hardware Installation

Installation & Operation Guide

AMX AMX-1881 HD/SD 8 AES Embedder Guide to Installation and Operation M February Description.

System Interface Unit SIU-100/100T

A-100G6 - Basic frame assembly diagram

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

Studer D21m. I/O System Components. Condensed Information

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

Ashly WR-5 Remote Control

Contents. Chapter 1 Introduction to the CP-20. CP-20 Control Panel Technical Support Chapter 2 Executing Switches

Fibre Modem - Single-mode

FPA-1 Facility Port Adapter Installation Guide

Kaleido-K Feature-rich display elements toll free: or Kaleido-K has a wide selection of display elements to construct e

OXYGEN 5 DIGITAL BROADCAST DIGITAL MIXER FULLY BROADCAST DIGITAL MIXING CONSOLE

Transcendent Frequency Counter

INSTALLATION GUIDE. AXIS 291 1U Video Server Rack ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL

CONTENTS. 1. Motherboard installation Install 3½ and 5¼ drives Install PCI components Connect case leads to motherboard...

Blue Point Engineering

Network Upgrade for the LINK DAC III

EnerSure Installation Guide

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

8 Channel Video Receive Unit with 2 Bi-directional Data and Audio Channels plus Ethernet for a Dual Redundant multimode fibre ring.

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Videum Duo & Quattro Xpress

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

16x16 Modular Matrix Switch VM1600

MASELEC MTC-6 master transfer and monitor system

4 Channel Video Receive Unit with up to 8 Bi-directional Data and Audio Channels plus Ethernet

6 Channel RS-422 Board (P/N xxx) User s Manual. And. Troubleshooting Guide

V3.0 Software Quick Start Guide to the New Features

TRC-190 User s Manual

C8000. switch over & ducking

IRT Eurocard Type. DVA Mb/s ASI/SDI 8 O/P Reclocking Distribution Amplifier

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

The AMG5716A9 is designed to be powered using an AMG2001 standalone power supply.

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H User s Manual. Version A0. July / 28 / 2008

VISTEK V1608 DART RACK USER GUIDE.

Kramer Electronics, Ltd. USER MANUAL. Model: VS-162V. 16x16 Video Matrix Switcher

RS-422/485 PCIe Card

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners.

INSTALLATION INSTRUCTIONS

The Single Dimmer Board

User Manual. Sirius 600. Medium-scale router offering a mix of AES, SDI, ASI and HD and 3G signals in one frame. snellgroup.com

Technology Corporation. ADDERLINK X SERIES X2-MultiScreen

This package should include the following files.

4 Channel Video Receive Unit with Bi-directional Data Channel and Ethernet for a Singlemode Fibre Link

32 x 32 Modular Matrix Switch

HARTING econ 3000 Introduction and features

Supplementary manual UVR16x2E-DE/NP Relay versions

8 Channel Video Transmit Unit with Bi-directional Data Channel and Ethernet for a Multimode Fibre Link

16x16 Modular Matrix Switch VM1600A

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

Mini4 Dual Sonar Interface Board (P/N xxx) User s Manual And Troubleshooting Guide

HDx TDM Record/Playback Option Guide

Replacing Preamplifier Circuit Boards

ASTAT XB/XBm Remote Operator

Instruction Manual RR-915C Video Receiver With Bi-directional Multi-Protocol Data And Bi-directional Contact Closure

FITTING INSTRUCTIONS

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

MA1 Midi Analyzer M Series Module ELM Video Technology, Inc.

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

GL2200 MIXING CONSOLE

VLSI AppNote: VSx053 Simple DSP Board

Zonal LED Indicators.

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

WICE-SPI Hardware Operation Manual

Transcription:

eyeheight EM-4 AES audio option for playout user manual

Table of Contents 1 System Overview...4 1.1 Applications for the EM-4...4 1.2 Associated Equipment for the EM-4...5 1.2.1 Chassis Types...5 1.2.2 Control Surfaces...5 2 Installation...7 2.1 Installation of the EM-4 product...7 2.2 Installing the EM-4 into a flexibox...7 2.3 Connecting Video to an EM-4...7 2.4 Connecting Panels to the EM-4...8 3 Operation... 10 3.1 Manual control of the EM-4... 10 3.2 Automation Control of the EM-4... 10 3.3 Operational Menus for the EM-4... 11 4 Technical Appendix... 15 4.1 Technical Specification for the EM-4... 15 4.2 Jumpering the I-BUS (CAN-BUS) Termination... 15 4.3 CHP-100 SDI-TC-GPI Card... 16 4.3.1 Jumper Links on the Timecode and GPI I/O card... 16-2 -

Table of Figures Figure 1-1 The EM-4 Module....4 Figure 1-2 FlexiBox with flexipanel fitted...5 Figure 1-3 Desktop modular panel FP-10...5 Figure 1-4 IRU panel FP-9...6 Figure 2-1 Connections for the EM-4...8 Figure 2-2 I-Bus Connections and Termination...8 Figure 4-1 Location Of I-Bus Termination Link... 16 Figure 4-2 jumpers on the EM-4 I/O card... 16-3 -

1 System Overview This manual describes the function of the EM-4. This unit is an AES embedder and de-embedder designed to work with the MW-3E, mixer wipe unit. The system embeds AES audio onto the A and B SDI feeds to an Eyeheight MW-3E Mixer/Wipe module. (The MW-3E also mixes Embedded audio) hence effectively providing AES Audio mixing. The unit also contains a de-embedder to provide an AES output from the MW-3E or a unit further down the chain in an eyeheight playout system The EM-4 Product The EM-4 is a unit that will accept three standard SDI video inputs, and has four SDI outputs. Two of which are loop outputs, and the remaining two with embedded audio. The main features are :- 2 off Audio Embedders (AES into SDI). 1 off Audio De-embedder (AES from SDI). Audio Level controls. Figure 1-1 The EM-4 Module. 1.1 Applications for the EM-4 Applications for the EM-4 include the following:- - 4 -

AES audio option for the PresTX system Embedding and de-embedding AES audio 1.2 Associated Equipment for the EM-4 The EM-4 is a module and requires both a chassis and a control surface to function. 1.2.1 Chassis Types flexibox is a 1RU chassis. The order code is FB-9. This will hold a maximum of 3 EM-4 Modules with Hot Swap redundant PSU option and Hot Swap EM-4 modules. maxibox is an alternative low cost 1RU chassis. The order code is MX-9. This also will hold a maximum of 3 EM-4 modules but it has no redundant PSU option and the EM-4 units must be factory fitted. Figure 1-2 FlexiBox with flexipanel fitted 1.2.2 Control Surfaces flexipanel is a IRU control surface that fits on the Front of a 1RU flexibox. The order code is FP-9. A FlexiPanel can also be used in conjunction with a minibox, in this case the extra accessory (Order code RR-9) will be required FP-10 is a desk mounting control surface (Order code FP-10). This unit is a modular unit which can be used in conjunction with the units below. Figure 1-3 Desktop modular panel FP-10. - 5 -

Figure 1-4 IRU panel FP-9. - 6 -

2 Installation 2.1 Installation of the EM-4 product If this unit is already pre-installed in a flexibox (FB-9), or a maxibox, with either a local or a remote panel from the factory then refer to the "Hardware Installation Guide" which will be enclosed with the system. If this unit has been ordered separately, we assume here that you already have a flexibox system with a Flexipanel and that the flexibox has at least two spare slots above each other for the EM-4 card. If this system is part of a playout, please refer to the playout user guide for an example of the use of the EM-4. 2.2 Installing the EM-4 into a flexibox To install the EM-4 into a flexibox it is desirable (but not necessary) to power down the flexibox. Follow these instructions. On the rear of the flexibox are 6 slots for Products. Remove any pair of spare blanking plates one above another. There are 2 off M2.5 Screws, which require unfastening for each blanking plate. Slide the Product PCB into the spare slots and firmly push it "home". Use the four thumbscrews to fasten the unit in place. Take care that the ribbon cable for the upper circuit board stays attached to the lower board. Now refer to the "GeNETics User Guide". If your system consists of a single flexibox with a single flexipanel then refer to the section titled "flexipanel Auto Set-up". If your system is part of a network with more than one flexipanel then refer to the section titled "flexipanel Manual Set-up". This will guide you through acquiring your product as a device on the flexipanel. 2.3 Connecting Video to an EM-4 The connections on an EM-4 are shown below, video in and out are shown and the table gives the pin numbers on the 15W D type. - 7 -

Pin Number Function 1 AES 1 Input+ (EMBEDS ON OUTPUT 1) 2 AES 1 Input- (EMBEDS ON OUTPUT 1) 3 AES 2 Input+ (EMBEDS ON OUTPUT 2) 4 AES 2 Input- (EMBEDS ON OUTPUT 2) 5 AES Output + (AES FROM INPUT 3) 6 AES Output - (AES FROM INPUT 3) 7 AES Output + (AES FROM INPUT 3) 8 AES Output - (AES FROM INPUT 3) 9 AES Output + (AES FROM INPUT 3) 10 AES Output - (AES FROM INPUT 3) 11 AES Output + (AES FROM INPUT 3) 12 AES Output - (AES FROM INPUT 3) 13 GPI #1 (not used) 14 GPI #2 (not used) 15 GND Figure 2-1 Connections for the EM-4 2.4 Connecting Panels to the EM-4 The EM-4 may be operated using a FP-9 Flexipanel locally mounted. For a more operational environment the EM-4 may be supplied with a desk mounting FP-10 unit. For detailed information on connecting remote panels refer to the section Connection of Remote Panels to a flexibox in the genetics Hardware Installation Guide. Below is shown a typical system consisting of an EM-4 in a flexibox controlled by an FP-10 and a VP-10. ** Connect Pins 1,2,4,7,9 from chassis to panels (1:1). Use twisted pair AES Digital Audio cable for pins 2 and 7. Pins 1,4,9 carry power 0.5 Amp, 13V. Use cable with a least a 1 amp rating for pins 1,4,9. Cable llength should not exceed 250m. ** I-Bus pins 2 & 7 ** The I-BUS Network requires terminating with 100 Ohms at each extreme end of the network. Ensure that this is done either by an external 100 ohm resistor OR ONE Panel/Product at each end has the termination set. See the "Genetics User Guide" Under the sections "Flexipanel Power/I-BUS Jumpers".For the 4RU Panels see 4RU Panel (FP-10) Jumpers for I-BUS and 4RU Panel (VP-10, SW-10, AP-10) Jumpers for I-BUS. Alternatively The termination can be set on a Product (ie the AD-2/AD-2E module). Information about this is given in this manual. Figure 2-2 I-Bus Connections and Termination - 8 -

N.B. From 1/10/02 Eyeheight introduced a change in the flexibox Chassis. Most versions now have two 9 way connectors on the rear labelled I-Bus and D- Bus. The I-Bus connector is the same as the previously labelled Can-B connector. Although a maxibox is shown in this diagram the same arrangement applies for a flexibox chassis. Please also note that this shows a T-Bar module (VP-10) the connections are the same for the AP-10 fader module. - 9 -

3 Operation 3.1 Manual control of the EM-4 Manual Control of the EM-4 is done using one or more of the following control surfaces: The 1RU FP-9 flexipanel. The FP10 Desk mounting panel The FP-9 and the FP-10 have identical manual control systems. (The FP- 10 is simply a desktop version of the FP-9). The AP-10 brings further functionality to the unit in the manual fader transitions. The EM-4 is, as are all genetics modules, controlled using a set of MENUS. Each of these menus contains up to 3 parameters that are adjusted using the rotary digipots. The Menus define all of the adjustable operational parameters in the EM-4. Pressing the rotary digipots brings the parameter to its default value. Device selection is done using the device select switches which, when pressed, will offer the name of the device in the LCD Window. Modules can be acquired and then de-acquired using the set-up switch. For a full description of the operation philosophy of the genetics system refer to the genetics User Guide (section Operation of the flexipanel ) A full list of the Menus and their functions are given in section 3 of this chapter. 3.2 Automation Control of the EM-4 Automation of the genetics products is achieved via an RS422 port.** This port is marked RS422 on the rear of a flexibox. For the port to work a flexipanel MUST be connected locally on the front of the flexibox. Automation control of the EM-4 can be done using two protocol methods: genetics Automation Protocol. PresTX Automation Protocol. Genetics protocol is described in detail in the GeNETics User Guide section titled Automation Protocol on the genetics Platform. The menu list in section 3 of this chapter contains the data information for the protocol. PresTX Automation Protocol is used only for the PresTX Presentation Mixer and channel branding system. In this case an AU-2 Automation card is also required. Refer to the PresTX Product manual **On most flexiboxes later than 1/10/02 the RS422 port has been replaced by a D-Bus Port. The D-Bus port is for High Speed data transfer and is not used for serial control. In order to achieve serial control of any products on an I-Bus network Eyeheight Ltd have developed a RS232 I-bus converter dongle, (DG- 9) which enables greater flexibility of products on the I-Bus network whilst using the same protocols as the RS422 port. Please refer to the User guide for the - 10 -

DG-9 eyeheight dongle and set-up software. 3.3 Operational Menus for the EM-4 Menu 00-03: Top level controls Level I/P A = 100% Level I/P B = 100% Output Level = 100% MEMORY option Menu Num. Heading Automation Function 0 Level I/P A (0 to 800%) 1 Level I/P B (0 to 800%) 2 Output Level (0 to 400%) O to 8191 Default is 1024 (=100%) O to 8191 Default is 1024 (=100%) O to 8191 Default is 2048 (=100%) This option adjusts the level of the A input. This option adjusts the level of the A input. This option adjusts the output level. 3 Memory N/A Pressing this button will select the memory control menus. Menu 04-07: Memory Controls (Mem1) (Mem2) (Mem3) BACK =main= Menu Heading Automation Function Num. 4 MEM1 1=Recall Pressing this will recall Memory number 1.User Names can be programmed in to the memories using a keyboard. - 11 -

See genetics User guide, section Giving product Memories names 5 MEM2 1=Recall Pressing this will recall Memory number 2. 6 MEM3 1=Recall Pressing this will recall Memory number 3. 7 Back N/A Pressing this button will take the user back to the main menu Menu 08-11: Memory Controls (Mem4) (Mem5) (Mem6) BACK =main= Menu Num. Heading Automation Function 8 MEM4 1=Recall Pressing this will recall Memory number 4. 9 MEM5 1=Recall Pressing this will recall Memory number 5. 10 MEM6 1=Recall Pressing this will recall Memory number 6. 11 Back N/A Pressing this button will take the user back to the main menu Menu 12-15: Memory Controls Save Mem. 1 Save Mem. 2 Save Mem. 3 BACK =main= - 12 -

Menu Num. 12 Save Mem. 1 Heading Automation Function 1= Save Pressing this will Save Memory number 1. 13 Save Mem. 2 14 Save Mem. 3 1= Save Pressing this will Save Memory number 2. 1= Save Pressing this will Save Memory number 3. 15 Back N/A Pressing this button will take the user back to the main menu Menu 16-19: Memory Controls Save Mem. 4 Save Mem. 5 Save Mem. 6 BACK =main= Menu Num. 16 Save Mem. 4 Heading Automation Function 1= Save Pressing this will Save Memory number 4. 17 Save Mem. 5 18 Save Mem. 6 1= Save Pressing this will Save Memory number 5. 1= Save Pressing this will Save Memory number 6. 19 Back N/A Pressing this button will take the user back to the main menu Menu 20-23: Software version SOFTWA ---- RE VER ---- EM-4 250303 Ver1.1 BACK =main= - 13 -

Menu Num. Heading Automation Function 20 N/A Info 21 N/A Info 22 EM-4 230103 Ver2.5 N/A Info, the top line is product identifier, the middle is the date the software was last changed, and the last line is the software version. 23 BACK N/A Pressing this button will take the user back to the main menu Menu 24-27: Top Level Controls Set As Pow On Memory Recall Pow On Memory TOTAL! RESET!!!!!!! BACK =main= Menu Num. Heading Automation Function 24 Set As Pow On Memory 25 Recall Pow On Memory 26 TOTAL RESET 1=save 1=Recall 1=Reset Pressing this will save the current set up as the power on default. Pressing this will recall the power on default settings. Pressing this will reset the system. 27 BACK N/A Pressing this button will take the user back to the main menu - 14 -

4 Technical Appendix 4.1 Technical Specification for the EM-4 Number of Inputs 3 Type of Inputs 270Mbit Serial Digital Video Inputs 75 Ohm, comprising of 2 inputs for embedders and 1 input for de-embedder. 2 AES Audio Inputs (to embed) Line Length At least 200 Meters of PSF1/3 (Typically 275 Meters) Number of Outputs 4 Output BNC s, 2 SDI outputs for embedders, 1 SDI output for de-embedder, and a loop for input 1. Type Of Outputs Total Number Of BNC Connections SDI Output Jitter Current Consumption <800mA at +5V Size 215mm by 100mm 4 off AES audio output streams (two audio streams with two outputs per stream. Output of de-embedder) 270Mbit Serial Digital Video Outputs, 75 Ohm, 800mV 7, consisting of 3 Inputs, 4 outputs. The system will add less than 0.2UI to the input Jitter. (This is only guaranteed on issue 2 or later cards) 4.2 Jumpering the I-BUS (CAN-BUS) Termination The I-BUS Network is the "control system" under which all Products and Panels are networked together. Under certain circumstances it is necessary to terminate the network. This can be done on a Panel or a "Product". To terminate this product, locate J6 on the EM-4 Processor Card supplied which is between U1 (The large square "chip") and the Edge connector. (This is on the half of the card labelled "CHP-100 Spartan2 Processor"). Jumper this with a 2mm link. - 15 -

J6 Figure 4-1 Location Of I-Bus Termination Link 4.3 CHP-100 SDI-TC-GPI Card 4.3.1 Jumper Links on the Timecode and GPI I/O card The AES output has a number of jumper links, which effect the formatting of the AES, output data. LK1 LK10 Data Format Jumpers. Figure 4-2 jumpers on the EM-4 I/O card - 16 -

Link No. Function of LK1 LK10 Links Standard 10 Emphasis1, combined with Emphasis0 sets the Equalisation data on the channel status bits 9 Emphasis0, combined with Emphasis1 sets the Equalisation data on the channel status bits 2 Stereo mode set in Channel Status bits. (Link to set) No Link Link Link 1 User Bit set in Channel Status bits. (Link to clear) Link 4 Diagnostic MUST BE LINKED!! Link 7 Validity Bit set in Channel Status bits. (Link to clear) No Link 8 Sampling Freq1. combined with Sampling Freq0 No Link sets the Sampling Frequency data on the channel status bits. 3 Non-Audio Bit set in Channel Status bits. (Link to No Link set) 6 Professional Mode Bit set in Channel Status bits. (Link to set) Link 5 Sampling Freq0. combined with Sampling Freq1 sets the Sampling Frequency data on the channel status bits. Link Emphasis0 Emphasis1 Function No Link No Link Undefined Emphasis Link No Link No Emphasis No Link Link 50/15uS Emphasis Link Link CCITT J17 Emphasis Sampling Freq0 Sampling Freq1 Function No Link No Link 32.0K Sampling Link No Link 48.0K Sampling No Link Link 44.1K Sampling Link Link Sampling Freq Not Indicated. - 17 -