MICRO GROW GREENHOUSE SYSTEMS, INC

Similar documents
MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX

MICRO GROW GREENHOUSE SYSTEMS, INC

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

S82S (3/7.5-W Models)

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

ICM 400. Three Phase Voltage Monitor with Reset Switch. Low cost line voltage protection for 3-phase motor systems

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

OZONE SWITCH Model OS-6. OS-6 Features

Tempco Instruction Manual

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

I2:34 MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT. Heat only, or Cool only. Meets California Title 24 Residential USERS INFORMATION MANUAL

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Digital Lighting Systems, Inc.

Cantata m100 Amplifier

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Integrated Stepper Drive & Motor

SMD Series Integrated Stepper Driver and Motor Revision 1.3

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

PMDX-105 Quad Isolator Board

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

INTRODUCTION. FX-1 Operations Manual. Standard Features. Optional Features. Read This Manual Completely Before Proceeding!

I/O Expansion Box Installation & Operator s Instruction Manual

Application Engineering

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

PS8 - II. Professional Power Sequencer. User s Manual

Global Water Instrumentation, Inc.

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

TC-9102 Series Surface Mount Temperature Controllers

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

SP6R Level Controller Operation Manual

Number of input channels

Basketball Shot Clock Set LX2180 Manual

SOLARIMMERSION IV Advanced Installation Manual v1.9

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail

Instruction Manual CTC-1

Evolution Variable Output. With Override Pot. Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033

User's Guide. Model High Precision Quad Output DC Power Supply

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

Bid Specifications and General Description

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

FIT. Fuel Island Terminal Installation and Operation Manual. The material in this manual is subject to engineering changes and editorial revisions

MAXIMA + Series ROTARY LEVEL CONTROL

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

Brasch Washdown Unit Heaters

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

OPERATOR S MANUAL FPD 50 WATT POWER SUPPLY. Flat Pack Single Output DC to DC Converter 50 Watt Output 24 Vdc Nominal Input

MAXIMA + Series ROTARY LEVEL CONTROL

Sapling Converter Box

DC425 NEMA 4X Analog Output Transducers

RB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Product Description. S&C 5800 Series Automatic Switch Control S&C ELECTRIC COMPANY TABLE OF CONTENTS

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

icp installation guide

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Spec Tech Industrial Electric Technical Support. Model: DL34-(XX) Quick Start

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

BTU 4 & Sensors. Installation and Operation Manual

Solid State Relays with Failure Detection Function

EMS Electrical Management System

MAXIMA+ Series Rotary Level Indicator

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

True RMS AC Voltage/Current Datalogger

S66 Series Electronic Fan Speed Control

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

X-11s Users Manual. X-11s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

MPF-1, Mains Power Filter User Manual

MR52 READER INTERFACE

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

LPG STM 94442A User s Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

FNet Repeater Installation & Operator s Instruction Manual

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Transcription:

MICRO GROW GREENHOUSE SYSTEMS, INC 4065 ZEVO DR., UNIT B-, TEMECULA, CA 9590 PHONE (95) 96-3340 FAX (95) 96-3350 www.microgrow.com Revision., -09-0 Growstat Control Series

INSTALLATION PROCEDURES SERIES OF CONTROLLERS PANEL MOUNTING Mount the control panel in an accessible location. Make sure that the location is free of vibration and in close proximity to the devices being controlled. Always consider voltage drop of electrical current when locating the control panel. Securely mount the panel. SWITCHING CONTACTORS AND RELAYS The control panel will operate the greenhouse equipment via load contactors and load relays. ALL RELAYS AND LOAD CONTACTORS USED MUST HAVE A SURGE SUPPRESSOR INSTALLED ACROSS THE COIL OF THE RELAY OR LOAD CONTACTOR. These surge suppressors are readily available from Micro Grow Greenhouse Systems, Inc. All load contactors and relays are also readily available from Micro Grow Greenhouse Systems, Inc. To decide which to use, follow this guide: LOAD CONTACTORS: Exhaust fans, pad pumps, horizontal air flow fans, heating pumps, fan jets, large heaters, crop lighting, and all other larger electrical loads over /6 H.P. LOAD RELAYS: Signal switching such as the small control lines for gas fired heaters, control lines for vent and shade system controls, small loads such as motorized shutters, other loads up to /6 H.P. CUSTOM CONTACTOR AND RELAY PANEL AVAILABLE A UL, custom pre-wired load contactor and load relay panel is available from Micro Grow Greenhouse Systems, Inc. This panel will contain all of the required switching apparatus for your project, as well as a correctly sized machine tool transformer. Contact Micro Grow Greenhouse Systems, Inc for pricing and availability. TRANSFORMERS The control panel is to be powered by a 4 VAC transformer. It is most important to use a MACHINE TOOL TYPE. A Machine Tool Transformer is a heavy-duty variety that will allow for high inrush currents that are associated with the use of load contactors and relays. Micro Grow Greenhouse Systems, Inc. stocks this type of transformer. Use no smaller than a 40 VA Machine Tool Transformer. ELECTRICAL CIRCUITS The electrical circuit that feeds the machine tool transformer must have no other loads connected to it. This will prevent a damaging surge from other related electrical devices. Follow all local and national codes in the connection of all of the greenhouse equipment. Always allow for voltage drop conditions. Always consider that the greenhouse is a wet environment. Always follow the code rulings for disconnect switches and overcurrent devices on greenhouse equipment. USE A QUALIFIED AND LICENSED ELECTRICIAN AT ALL TIMES.

WIRING METHODS Always use stranded wire when connecting cables or conductors to the actual circuit board of the control panel. This will allow flexibility. Use no smaller than #8 gauge, stranded wire for all outputs. Use no smaller than the recommended wire size of stranded cable for inputs; generally # gauge. SENSOR CONDUCTORS: Route sensor conductors separately from control conductors. This is very important so as to reduce electrical interference. Never route sensor conductors in conduits used for other voltages. This is in violation of the electrical code and will cause dangerous interference to the control system. Always locate the actual sensor in the center of the range that is being controlled for accurate readings. Do not allow the sensor to come in contact with any greenhouse structure member such as a post that would give off any radiated heat and cause a false temperature reading. Do not locate the sensor where a particular piece of equipment would cause false readings, such as a heater blowing directly on the sensor. Mount all wind/rain sensor is a clear area, free of any wind obstructions. CONTROL CONDUCTORS: Route all control conductors separately from sensor conductors. This is very important so as to reduce electrical interference. Control conductors maybe routed in conduits that contain other power system wiring only if the insulation material on the conductors is the same as the power system wiring. Consult the national electrical code or local codes if in doubt about the insulation ratings of the wire in use. Remember; always use a qualified and licensed electrician. VENT SYSTEMS, ROLL UP CURTAINS When connecting a vent system, or roll up curtain ventilation system to the control panel, you must use a separate control box designed for that particular vent system. These are readily available from Micro Grow Greenhouse Systems, Inc. Generally these separate control boxes feature overcurrent protection for the particular motor on the vent or shade system, provisions for direct limit switch connections, and a manual means of operating the vent system independent of the main control system. These separate control boxes will connect the main control system either directly through the outputs of the control system, or they will require control relays for interconnection to the main control system. Consult the individual instructions that come with the vent or shade controls for detailed information. SYSTEM TESTING It is always important to completely and fully test the electrical system by energizing circuits and verifying equipment operations before automatically operating the equipment from the control panel. This would include setting all of the vent limit switches at the individual control panels. 3

Micro Grow Greenhouse Systems, Inc. Growstat Set Temperature:. Depress the SET switch once. The OUTPUT indicator will be on. Use the VALUE switch to set the correct desired setting. This will be the day mode setting. Depress the SET switch again to light the NIGHT indicator along with the OUTPUT indicator. Set the desired night level here.. (If DIF is not used, this instruction will not apply) If DIF is being used, the temperature setting for the DIF time period will be set next. Continue to depress the SET switch until the word DIF is displayed. The control will show the DIF temperature. Use the VALUE switch to set the desired DIF temperature. 3. Depress the SET switch again. The OUTPUT indicator will be on. Use the VALUE switch to set the all of the desired settings for output. Repeat for the night mode and DIF (if in use) as outlined above. 4. Return to the run mode by toggling the RUN switch up. To Check High and Low History: The control will automatically track the high and low readings for the past 4 hours for both inputs. To check them, depress the SET switch until the word "HIGH" appears in the display. The control will automatically indicate the highest reading for the past 4 hours. Depress the SET switch until the word "LO" appears in the display. The control will automatically indicate the highest reading for the past 4 hours. If you would like to reset these values, depress VALUE switch once while the system is in the high and low mode. The system will however automatically update these readings continuously. To Set the Clock:. Continue to depress the SET switch until the SET TIME indicator is on. The item to be set will be flashing. Use the VALUE switch to raise or lower the flashing value. The first value will be hours. Depress the SET switch again to set the minutes, and once more to set if it is AM or PM. To Set the Day and Night Mode Times: The control can detect night automatically with the use of an external photocell. If no photocell is connected, it will use the internal 4-hour time clock. You can also use a combination of both if desired.. Continue to depress the SET switch until the SET DAY MODE indicator is on. If a photocell is connected to the system, adjust the hours setting till the word "PHO" appears in the display. If a photocell is not connected, a time can be set. Use the VALUE switch to change the setting.. Depress the SET switch again and repeat the above procedure to SET NIGHT MODE. If you do not want the NIGHT mode to be used, adjust the hours setting till OFF appears in the display. 4

To Activate the DIF Mode The Growstat has a built in DIF mode of operation. The DIF mode is used to control plant growth based on a temperature differential between the day and night modes. The Growstat allows the user to set a special time for this mode. For truly automatic operation, a photocell should be used to automatically detect the actual sunrise time. To set the DIF time period:. Continue to depress the SET switch while the SET TIME indicator is on while the DIF indicator is also lit. the word "OFF" will be shown. This means that the DIF mode is disabled. By toggling the VALUE switch, a number proceeded by a negative sign will be shown (-8.0 example). This will be the number of hours before sunrise, or before the set day mode time that the Growstat will use to enter the DIF mode. Set any value in.5 hour increments desired. After this negative number is set, depress the SET switch again. A number will appear without a negative sign in front of it (.0 example). This will be number of hours after sunrise or after the set day mode that the Growstat will use to exit the DIF mode.. Return to the run mode when finished. To Calibrate the Control: The control can be calibrated easily. Calibration is best performed in the early or late hours to prevent the interaction of the solar influence. Using a good mercury or digital thermometer and hydrometer, obtain the value to calibrate the control to.. Continue to depress the SET switch until the CALIB is on the display. The first number to appear afterwards is the temperature. Use the VALUE switch to change the setting.. Depress the SET switch again and repeat the above procedure to set the humidity reading. Return to the run mode when finished. 5

BLACK AIR TEMPERATURE SENSOR TO SENSOR TERMINAL AIR TEMPERATURE BLACK LOCATE SENSOR IN THE CENTER OF THE CONTROLLED AREA, AT BENCH OR CROP LEVEL, AWAY FROM DIRECT CONTACT WITH GREENHOUSE METAL POSTS AND MEMBERS. SENSORS MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project SENSORS Drawn by Date Distributor Order ID SC 4/7/09 MICRO GROW N/A 6

INDOOR / OUTDOOR TEMPERATURE SENSOR CONNECTION AIR TEMPERATURE SENSOR LOCATE IN THE CENTER OF CONTROLLED AREA, AWAY FROM DIRECT CONTACT WITH GREENHOUSE METAL POSTS AND MEMBERS. AIR TEMPERATURE AIR TEMPERATURE SENSOR LOCATE IN THE CENTER OF CONTROLLED AREA, AWAY FROM DIRECT CONTACT WITH GREENHOUSE METAL POSTS AND MEMBERS. AIR TEMPERATURE OUTPUT OUTPUT OUTPUT 4 VAC 4V COM 3 +5 VDC COM SENSOR INPUT TERMINAL 4 VAC 4V COM SHA AIR TEMPERATURE SENSOR AIR TEMPERATURE AIR TEMPERATURE SENSOR OUTPUT OUTPUT OUTPUT 4 VAC 4V COM 4 VAC 4V COM 3 +5 VDC COM SENSOR INPUT TERMINAL NOTE: IF AIR TEMPERATURE SENSOR IS SHA YOU MUST CUT R6 PULL UP RESISTOR FOR AN ACCURATE AIR TEMPERATURE READING. MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project SENSOR CONNECTIONS Drawn by Date Distributor Order ID SC /03/0 N/A N/A 7

DIP SWITCH SETTINGS TEMPERATURE MODE # OFF # ON FAHRENHEIT CENTIGRADE # ON IN USE # OFF NO TEMPERATURE DIFFERENTIAL # 3 OFF # 3 ON # 3 OFF # 3 ON # 4 OFF # 4 OFF # 4 ON # 4 ON DEGREE DEGREES 3 DEGREES 4 DEGREES DIF ENABLE # 5 OFF DIF OFF # 5 ON DIF ON TIME DELAY # 7 OFF # 8 OFF # 7 ON # 8 OFF # 7 OFF # 8 ON # 7 ON # 8 ON OUTPUT DEFINITION # OFF HEATING # ON COOLING # OFF HEATING # ON COOLING SECONDS 30 SECONDS 60 SECONDS 0 SECONDS OUTPUT NOTE: THE CONTROL OUTPUTS ARE RATED AT AMP @ 4 VAC EACH MAXIMUM. DO NOT EXCEED THIS OR DAMAGE MAY RESULT. DO NOT EXCEED AMP @ 4 VAC FOR ANY SINGLE OUTPUT. TEMPERATURE # TEMPERATURE # +5 VDC TERMINAL 3 +5 COM SENSOR INPUT TERMINAL OUTPUT # OUTPUT # OUTPUT 4 COM 4VAC 4VAC 4 COM POWER INPUT 4 VAC MACHINE TOOL TRANSFORMER INPUTS AND OUTPUTS MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project Drawn by INPUTS AND OUTPUTS Date Distributor Order ID GH /3/0 N/A N/A 8

ACCURACY READOUT PROGRAMMING MANUAL SWITCHES TIME DELAY DIFFERENTIAL ENCLOSURE VOLTAGE PHYSICAL SIZE TEMPERATURE +/- F /" LCD, F OR C SELECTABLE TOGGLE SWITCH ALL OUTPUTS USER SELECTABLE USER SELECTABLE WEATHERPROOF, CLEAR COVER 4 VAC 6.65" W x 6.75" H x 4.65" D MICRO GROW GREENHOUSE SYSTEMS, INC. LARGE, EASY TO READ DISPLAY FOR CURRENT HIGH AND LOW TEMPERTURES FRONT PANEL TOGGLE SWITCHES FOR EASY PROGRAMMING AND CALIBRATION OUTPUT OUTPUT NIGHT RUN SET - 70 L F VALUE SET TIME SET DAY MODE SET NIGHT MODE OUTPUT OUTPUT EACH OUTPUT HAS A FRONT PANEL MOUNTED SWITCH TO SELECT THE MODE OF OPERATION ON AUTO OFF LIGHTED STATUS INDICATORS WILL SHOW ANY STAGE IN OPERATION WEATHERPROOF ENCLOSURE WITH LOCKABLE CLEAR, LEXAN COVER AIR TEMPERATURE AIR TEMPERATURE SENSOR LOCATE IN THE CENTER OF CONTROLLED AREA, AWAY FROM DIRECT CONTACT WITH GREENHOUSE METAL POSTS AND MEMBERS. OUTPUT OUTPUT OUTPUT 4 VAC 4V COM 3 +5 VDC COM SENSOR INPUT TERMINAL DIP SWITCH GROWER DEFINED ADJUSTMENTS FOR TEMPERATURE DIFFERENTIALS, TIME DELAYS, ETC. 4 VAC TRANSFORMER 40 VA MINIMUM RATING 4 VAC 4 VAC COMMON 4 VAC 4V COM CPU ON BOARD MICROPROCESSOR MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project Drawn by Date Distributor Order ID SC /04/0 N/A N/A 9

LIMITED WARRANTY Micro Grow Greenhouse Systems, Inc. warrants that all of the products Micro Grow Greenhouse Systems, Inc. manufactures are free from defects at the time of shipment by Micro Grow Greenhouse Systems, Inc. This warranty covers defects in workmanship and materials. No warranty is extended on any parts, materials, or components manufactured by others and purchased by Micro Grow Greenhouse Systems, Inc., and any warranty on these materials is limited to the warranty supplied by the original manufacturer or supplier of said products only. This warranty excludes any and all damages cause by installation by unqualified individuals, damage by misuse or neglect, shipment damage, alterations to original manufacturing, and improper installation or use for any reason than intended by manufacturer. This warranty may not be altered in any manner except with the written authorization of one the officers or owners of Micro Grow Greenhouse Systems, Inc. The only and sole liability of Micro Grow Greenhouse Systems, Inc. under this warranty is limited to repairing, replacing or the issuance of credit for any products returned to Micro Grow Greenhouse Systems, Inc., during the warranty period of twelve () months from date of shipment. This warranty is specifically conditioned upon Micro Grow Greenhouse Systems, Inc. being notified in writing promptly upon discovery of any product defects by the buyer or end user. The product must then be returned prepaid to Micro Grow Greenhouse Systems, Inc. within the twelve month warranty period for inspection by Micro Grow Greenhouse Systems, Inc. Upon inspection of said product, Micro Grow Greenhouse Systems, Inc. will notify buyer or end user of its findings. At Micro Grow Greenhouse Systems, Inc. sole discretion, the product will be replaced, repaired or a credit will be issued for the original sale price of the product, provided that damage has not occurred due to misuse, neglect, improper use or installation as outlined above, shipping damages or accident. MICRO GROW GREENHOUSE SYSTEMS, INC. SHALL NOT BE LIABLE FOR ANY DAMAGES BEYOND THE ACTUAL ORIGINAL COST OF THEIR PRODUCT EITHER DIRECTLY OR INDIRECTLY ARISING FROM DEFECTIVE PRODUCTS OR WORKMANSHIP. 0