Tech Byte 25: UPS Systems - Key To Ensuring Business Continuity - Part 1

Similar documents
02 Why Does My IT Infrastructure Need a UPS?

Tech Byte 22: Why Surge Protection Awareness Must Increase

White Paper Power and Its Connection to Network Reliability

Tel: AC Power for Business-Critical Continuity TM

Design for Critical Power Loads. Bryan A. Snyder, PMP Product Application Specialist

WHITEPAPER WHITEPAPER. GE s eboost Technology Reducing Data Center Power Consumption, Ensuring Power Quality. Silvio Colombi.

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Common Power Problems & Power Protection Solutions

The Future of DATA CENTER CRITICAL POWER

SE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality,

A Dell Technical White Paper Dell

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Redundant Power Supplies. Keep Machines Up When Power Goes Down

Industrial Facility Wide Protection

IP Telephony. Contact Centers. Mobility. Services Avaya Overview Brochure

Modular and Scalable Power Converters in the UPS Industry

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

Converged Power Solutions. Data center power reinvented

"Powering and Protecting Networks and Equipment Connected to It" Jim Pelegris ITW/LINX

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

National Survey on Data Center Outages

Continuous power. Digital static transfer switches for increased data center reliability

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Data Centers: The Case For Energy Risk Management and Energy Reliability

POWERING NETWORK RESILIENCY WITH UPS LIFECYCLE MANAGEMENT

Tech Byte 20: The Benefits of Power Switching in Dual Bus UPS Designs

Liebert GXT MT kva

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

UPS Operating Modes: A Global Standard. A White Paper from the Experts in Business-Critical Continuity

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Power Quality of Commercial Buildings - Advanced

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

Careful What You Wish For: Poor Colocation Design Could Cost You. Thorough assessment of upfront costs to prevent future system failures

Power Quality. The Overlooked Productivity Variable

BUSINESS CONTINUITY: THE PROFIT SCENARIO

Liebert NX Series. 30kVA to 200kVA. AC Power For Business-Critical Continuity

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Reliability Models for Electric Power Systems

Help your Cisco customers defend against downtime and reduce costs

Manage power your way

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

SystemTrust is the authorized distributor and partner of Borri UK in Nigeria

Imperva Incapsula Survey: What DDoS Attacks Really Cost Businesses

REMOTE IT MANAGEMENT SOLUTIONS: MANAGE REMOTE OFFICES WITHOUT LEAVING YOURS

EMC GLOBAL DATA PROTECTION INDEX KEY FINDINGS & RESULTS FOR ITALY

Ensuring business continuity with comprehensive and cost-effective disaster recovery service.

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Infrastructure for the Architecture

Newave s approach for protecting mission critical application

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Modular, scalable, high-efficiency power protection for data centers

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

DATA CENTER SERVICES. A Higher Level of Service Expertise

Dirty Power... A Guide to Surge Suppression & Filtering. Surge & Signal Protection for Business-Critical Continuity. EmersonNetworkPower.

UPS series PROTECT C. / C.R. Double conversion UPS with true sine wave - output

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment?

IBM TS7700 grid solutions for business continuity

Liebert LM Series. Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Power Management Solutions Maximise the reliability and efficiency of your power critical facility

Backup vs. Business Continuity

Redefining Power Quality

ADDRESSING CHALLENGES TO POWERING SMALL TO MIDSIZE IT SPACES

Customer Breach Support A Deloitte managed service. Notifying, supporting and protecting your customers through a data breach

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

The case for cloud-based data backup

Consortium for Electric Infrastructure to Support a Digital Society An Initiative by EPRI and the Electricity Innovation Institute

AC Power Quality and Protection

Conducted by Vanson Bourne Research

EMC GLOBAL DATA PROTECTION INDEX STUDY KEY RESULTS & FINDINGS FOR THE USA

9900B UPS. The POWER of Green UNINTERRUPTIBLE POWER SUPPLIES

EMC GLOBAL DATA PROTECTION INDEX KEY FINDINGS & RESULTS FOR UAE

EMC GLOBAL DATA PROTECTION INDEX KEY FINDINGS & RESULTS FOR BRAZIL

HP NonStop Database Solution

Tel: Mobile: Tel: Fax:

EMC GLOBAL DATA PROTECTION INDEX KEY FINDINGS & RESULTS FOR AMERICAS

Common Mode Noise The Often Neglected Tenth Power Problem

THE NEW SHAPE OF NETWORK POWER PROTECTION

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

The power management skills gap

ARC BRIEF. Application Downtime, Your Productivity Killer. Overview. Trends in Plant Application Adoption. By John Blanchard and Greg Gorbach

EMC GLOBAL DATA PROTECTION INDEX KEY FINDINGS & RESULTS FOR APJ

Hitec QPS product range

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

5 Things Small Businesses Need to Know About Disaster Recovery

The data quality trends report

Gain Control Over Your Cloud Use with Cisco Cloud Consumption Professional Services

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Power and Cooling Design Guidelines for Network Access Rooms. A White Paper from the Experts in Business-Critical Continuity TM

Liebert APM 30, 60, 90, 120, 150kVA UPS Adaptive Power Quality Solution for Critical Applications

Ensuring Business Resilience Jim Neumann, Vice President of Marketing, Power Analytics Corp.

HANDOUT Electrical Safety How do we make sure that humans and computer equipment are safe from electrical hazards?

White Paper: Backup vs. Business Continuity. Backup vs. Business Continuity: Using RTO to Better Plan for Your Business

EMC GLOBAL DATA PROTECTION INDEX KEY FINDINGS & RESULTS FOR HONG KONG

A Computer Scientist Looks at the Energy Problem

TECHNOLOGY: THE COMPETITIVE ADVANTAGE FOR SUCCESSFUL RETAIL BUSINESS

Data Center Infrastructure Management (DCIM) Demystified

Transcription:

I don t need a UPS system, I have a generator This is one of the most common misconceptions that business owners or managers have when evaluating power protection for the critical elements of their business. They often agree that they need protection against outage conditions, but they do not fully understand how stand-by or back-up power systems operate when utility power fails. What does happen when utility power fails? Is your generator normally running at all times? Is it readily available so that when utility power fails, it can immediately provide power to the critical load without an interruption? No, that is not how back-up generator systems operate. Whether you have a generator or not, you will have a load outage when utility power fails, unless you have a UPS system. A generator simply guarantees that you can get back on line AF- TER the outage without having to wait for the utility to be repaired. Uninterruptible power supplies perform a critical role in the process of ensuring power availability and power conditioning to a given critical load, that cannot be provided by a generator system or the utility provider alone. In a nutshell, A UPS system provides the following significant benefits to a business-critical connected load: A UPS provides an instant, reserve power source to its connected load upon a utility source failure. The connected load sees no power loss between the time the utility fails and the UPS engages its back-up power source. A UPS provides a limited duration power source (batteries or flywheels) to either: Ride thru the outage. Hand-off to the facility generator source when faced with an extended duration outage. Or allow for an orderly shutdown in the absence of a facility generator when faced with an extended duration outage. Many UPS systems offer complete power conditioning to protect the connected load. This includes protection against sags, swells, spikes, noise, surges, frequency deviations, and single phasing. Why are these benefits important? They are important because they provide a means to business continuity. They allow for a business to maximize their investments in their critical technology and processes. Downtime of these systems costs businesses money. Unfortunately, the modern power grid does not adequately support critical operations and it appears to be getting worse. Electricity demand has jumped 30 percent over the past 10 years, while transmission capacity has increased only half that amount. As seen in August 2003, a strain in one location can cause the whole system to buckle. Consequently, each organization must create a power infrastructure that can deliver the power quality and reliability their critical systems require. OUTAGE SPIKE NOISE SWELL Common Power Quality Anomalies, Corrected By Many Managing the availability of critical systems requires an understanding of the risks and costs of losing access to business critical information or services, balanced against the cost of achieving a certain level of availability. The main challenge is understanding the actual costs of downtime to a business as a whole. Many businesses are still, to this day, unaware of the actual costs of power loss to a critical element of their business. This is mainly because of the ripple effects of the outage, and how downtime of one process affects interlinked levels of the business. Downtime cost considerations need to include: 1

Damage to mission critical data Impact of downtime on organizational productivity Damages to equipment and other assets Cost to detect and remediate systems and core business processes Legal and regulatory impact, including litigation defense cost Lost confidence and trust among key stakeholders Diminishment of marketplace brand and reputation Downtime duration does not often equal utility outage duration. The vast majority of critical systems can not be restarted instantaneously. A five second outage can lead to hours of downtime... It is important to note that power disturbances can disrupt business activities well beyond the actual length of the outage because a majority of critical systems can not be restarted instantaneously. The resulting downtime means lost production, revenue, and/ or sales that the business can not always make up later. This also leads to another misconception related to the need for UPS systems: Many individuals associate power outage with downtime. This is most often not the case. We cannot assume that our critical systems will ONLY be down for the duration of time that the utility is out. Downtime represents the amount of time necessary to fully RECOVER systems from the outage event and get them back to full operation. Let s use a simple example: If you were to pull the plug on your PC workstation and then reconnect it in 10 seconds, are you instantly back to the state of productivity you were at before you pulled the plug? Or, do you have to reboot and re-launch your applications in order to get back to your original state of productivity? Also, what if you had not saved your work before the plug was pulled? In reality, it would take a matter of minutes or possibly hours, not seconds, to get back to where to your left off. Knowing this, consider the same situation applied to a computer room. A hard shutdown of a computer room could take an hour or more to recover from. During this time, the business IT infrastructure would be unproductive and disrupting the continuity of the business. Perhaps not knowing what the downtime costs are for a particular business, let s look at the costs of downtime from a local, geographic perspective. EPRI (Electric Power Research Institute) created a research paper entitled The Cost of Power Disturbances To Industrial & Digital Economy Companies. In this paper, EPRI breaks down the costs, by state, of outages on Industrial and Digital businesses. As we can see on the table to the right, Michigan ranks in the top 10 nationwide in annual costs incurred due to power outages (over EPRI: Top Ten States with Highest Annual Outage Costs 2

$1.5 billion annually for sectors surveyed, estimated $3.7 billion to $5.9 billion for all business sectors). Power quality is also a significant factor in unexpected costs facing today s businesses. In the latest report titled World Transient Surge Suppressor Market in August of 2010, Frost and Sullivan provides research data pertaining to power quality related costs. The data used was collected from industry participants, industry experts, end users, regulatory organizations, financial and investment communities, and other related sources. The data was compiled and used to illustrate trends in the market place, demand for SPD devices, and to forecast the future of the industry. A significant finding in this report:: Every year, billions of dollars in revenues are lost due to power-related problems. It is estimated that 50% of the data loss at computer installations is attributed to power EPRI: Top Ten States with Highest Annual Power Quality Anomaly Costs quality problems. About 40% is due to transient voltage spikes and the remaining 10% is caused by other factors. More than 60% of transient voltages and surges originate within the facility and the remaining 40% occur outside the facility because of harsh weather conditions and utility grid switching. In EPRI research paper, The Cost of Power Disturbances To Industrial & Digital Economy Companies, EPRI also details costs associated with power quality anomalies. These are costs due to all other power quality anomalies EXCEPT outages. In the table above, we can see that Michigan still ranks in the top 10 of states suffering the highest costs due to PQ issues ($235 million annually among sectors surveyed, estimated $552 million to $895 million across all business sectors). Using the low and high estimates of annual power related costs to all business sectors in Michigan, there is a potential cost savings range of $4.3 billion to $6.8 billion dollars by protecting business critical equipment and processes from outages and power quality anomalies. A UPS system addresses both of these needs. So now that we understand the need for UPS system protection, let s look at how they work and what UPS sizes and form factors are available in the market....in Michigan, there is a potential cost savings range of $4.3 billion to $6.8 billion dollars by protecting business critical equipment and processes from outages and power quality anomalies. A UPS system addresses both of these needs. 3

HOW UPS SYSTEMS WORK In the context of a complete power quality and outage solution that includes a generator, the UPS works to condition power under normal operation, and acts as a bridge to the generator when utility power fails. The sequence of operation looks like this: Normal Mode: Utility provides power to the UPS input. The UPS rectifier breaks down AC power to DC, charges the DC plant, and supplies DC power to the UPS inverter. The UPS inverter creates an AC sine wave output, free from anomalies, to feed to the connected load. Utility Failure Mode: In the event the utility power feed fails or goes outside of its pre-defined voltage and frequency tolerances, the UPS rectifier stops supplying DC power to the UPS DC bus. The DC bus voltage collapses until it reaches the DC power plant open cell voltage. At that time, the DC plant begins discharging DC power to feed the inverter. The output of the UPS sees no degradation in power during this process. Generator Operation: When the automatic transfer switch (ATS - Which switches between utility power and generator power and feeds the UPS) sees the utility outage, it sends a signal to the generator to start up. Once the generator has started up and reaches the proper voltage and frequency levels, the ATS switches to the generator source. The generator power is then available at the UPS input. At this time, the UPS will qualify the generator source, and begin to walk its rectifier onto generator power. Once the rectifier starts up, the UPS will stop discharging its battery and operate from the generator input source. Operation With No Generator: In UPS applications where no generator exists, the UPS will supply power to the connected load for as long as its DC plant has adequate stored power. Once the DC plant is depleted and the utility source has not returned, the UPS initiates a shutdown. UPS battery plants typically range from 5-minutes to 1-hour of back-up time at full UPS load. The time it takes for the generator to come on line once a power outage is identified can be anywhere from 6 seconds to many minutes, depending on whether or not the generator starts on the first try, or if there are any complex paralleling operations that must take place before stand-by power can be switched onto the critical bus. This is the bridge that the UPS spans. It prevents that initial outage from the time the utility fails and the generator comes on line, and allows critical systems to continue operating normally. Summary...Every year, billions of dollars in revenues are lost due to power-related problems. It is estimated that 50% of the data loss at computer installations is attributed to power quality problems Power quality and outage events significantly impact a business s bottom line, resulting in billions of dollars in annual losses across the state of Michigan. A UPS system is a sound investment for protecting critical elements of a business operation from these events, leading to less downtime and increased revenue. UPS systems are available in a wide range of capacities, form-factors, and topologies. There are small UPS systems that sit on a desk to provide battery power to an individual PC, and there are facility-wide or large datacenter UPS systems that consume entire electrical rooms. There are also a range of offerings in between. Whatever the critical process, physical space, and/or budget, there is likely a UPS solution to fit the need and offer the benefit of business continuity. 4

Liebert is an industry leader in the Uninterruptible Power Supply and Power Conditioning industry. They offer a full range of UPS and Power Conditioning products and service solutions to address any customer need. Network Large Facility Power Distribution Systems Power Switching Systems Rack Mount Desk Top New Liebert Offering Liebert APM 3-Phase Modular / Scalable UPS System 15kW to 90kW Rack Power Distribution 5