PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL

Similar documents
TECHNYLIGHT. T Entertainment Lighting Effects. Please read this manual carefully before you initially start-up!

Mini Photoelectric Sensor

Octostrip ORDERCODE 42220

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

INTRODUCTION CT87E FEATURES AND CONTROLS

ITA100 MKII 100mW green DMX laser

Contents. - i - Ver.:2

1 Channel Strobe Controller ORDERCODE 40226

DOT MATRIX PRINTER SP6000 SERIES

RТTH DUAL ROOM SWITCH

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

DUAL LASER PACK & CONTROLLER USERS MANUAL

User Manual DUO BEAM/RG

ORYON RING LIGHTS. 14 in. Ring Light and 18 in. Ring Light. Quick Start Guide. What s Included

Universal AC Power Source + AC Power Analyzer

Laboratory Switch Mode Power Supply Series. Instruction Manual

7032 Digital-Analog Multimeter

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Use the ML830 Smart laser System only as directed.

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Motorized Curtain Tracks Progress 50 Motor Set

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

Geo3X HP BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI

User's Guide. MiniTec TM Series Model MN25 MultiMeter

DEB 575/1200. Electronic Flicker Free Ballast DMX MOD INSTRUCTION AND MAINTENANCE MANUAL

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

User's Guide. Model W 3-in-1 Switching DC Power Supply

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Haze 800 DMX. User Guide. English

Self-leveling Laser Marker (4V1HXL)

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

ENVIRONMENTAL PROTECTION

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Instruction Manual. Portable CD Player with Stereo Radio Cassette Recorder NPB-241

TECHNYLIGHT. T Entertainment Lighting Effects

B&W RearView Camera Installation & Operation

LaserLyte-Flex Red & Green Alignment System

RXTP ROOM TEMPERATURE

PHOS mini OPERATING INSTRUCTIONS

D-Pack 6 Classic ORDERCODE 50315

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

Back-UPS RS 550 Installation & Operation

DT-311J Digital Stroboscope Operation Manual

Digital Overhead Stirrer

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc.

Party Dimmer IEC ORDERCODE 50324

Large Police Light 100W ORDERCODE 80361

Optional add-on cassette Attachment Instruction manual

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

KDC-C712 KDC-C662 KDC-C462

icore Kiosk system Installation Guide

User Manual. Trinocular Stereo Microscope

TEL: / FAX:

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

impact INSTRUCTIONS LiteTrek 4.0 Monolight lighting equipment and accessories

CM-Z2212GY. Outdoor IR Speed Dome PTZ Camera

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

FT-20 Fire Training Fog Machine User Manual English

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

burst laser

DarkFX Spot 670 User Manual English

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Installation Job Aid for Ethernet Routing Switch 3600 Series

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter

CPA 40 Two Channel Amplifier

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Model 2380 Rack-Mount Kit

Stage Fog Machine User Manual

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Model 2380 Rack-Mount Kit

Tabletop Paper Collator FC-10

DC Power Supply APS-3320L APS-3610L

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Survival Laser SL-001.4PB Laser Parts Bundle Assembly & Operation Instructions

Axiomet AXB Safety instructions

INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

ECOLINE EL 515 PLUS EL 515 PLUS SET

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:

User's Guide. Phase Sequence and Motor Rotation Tester Model

Automated Tuner System Power Distribution Hub

XSIMA X-RAY EQUIPMENT

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS

CAUTION Use of controls or adjustment or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1

Instruction Manual. Professional 1000WS Incubating. Rocking Shaker. Waving Shaker

Instruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,

Mini Digital Multimeter

IPCB42501 / IPCB42551

V /06/ Velleman nv

Transcription:

HF80/15+DLP PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL Version 1.0

CONTENTS PAGE NO. NOTICE FOR SAFE OPERATION 2 INTRODUCTION... 3 NOTES TO USERS. 3 COMPONENTS.. 4 OPERATING CONDITIONS. 5 MAIN PARTS. 6 LASER ALIGNMENT INSTRUCTIONS. 8 OPERATING PROCEDURES 9 ERROR INDICATOR 11 SPECIFICATIONS.. 12 SCHEMATIC DIAGRAM.. 13 Thank you for purchasing your HF80/15+DLP portable veterinary x-ray unit. We are confident that you will be pleased with the radiographs you make with this model. This excellent unit will give you many years of reliable service. Please read this manual completely before using your HF80/15+DLP. We always welcome your comments and suggestions. - 1 -

NOTICE FOR SAFE OPERATION 1. X-ray equipment should be operated only by individuals who have appropriate training and licenses. 2. Please take the following precautions during installation: A. Keep equipment dry. B. Do not subject equipment to excessive atmospheric pressure, temperature, humidity, direct sunlight, dust, or air containing salt and sulphur. C. Do not subject equipment to excessive vibration and/or shock during transportation, etc. D. Do not store equipment under any adverse gaseous conditions. E. Insure that the input electrical voltage, amperage and hertz are correct and the unit is properly grounded. 3. During operation, consult and /or develop a technique chart for appropriate anatomy, distance, and screen/film combination. 4. After using the equipment: A. Remove cords carefully, if necessary. B. Keep equipment clean and dry. C. Store inside carrying case in a cool, dry environment. 5. Maintenance A. Equipment should be checked regularly to insure cleanliness and tightness of screws. B. When equipment has not been used for a long interval, check operation completely before putting into service. 6. Operate the equipment correctly according to this instruction manual. - 2 -

INTRODUCTION Your HF80/15+DLP is a constant potential portable x-ray device utilizing the latest high frequency inverter. The HF80/15+DLP has the following features: 1. A high frequency inverter with output greater than conventional models and constant x-ray tube voltage. 2. Compared with conventional generators, the wave form can be more than 2.5 times as effective. 3. kv and ma are corrected and stabilized by automatic feedback circuits. 4. X-ray tube focal spot size is 1.0 mm. Therefore, the quality of the resultant radiographs is equal to or better than x-ray taken by units with larger focal spots. 5. The HF80/15+DLP is very easy to carry by hand because of its small size and light weight. 6. The HF80/15+DLP incorporates a Dual Laser Pointer in the light beam collimator to indicate the distance of SID. As HF80/15+DLP uses high voltage, please read this manual carefully prior to operation. NOTES TO USERS 1. The HF80/15+DLP has been developed specially for veterinary x-ray applications. It should not be used for other applications. 2. Wall outlet of 16A (minimum) is recommended for the 230V model. 3. Be sure to use a grounded circuit. 4. During operation, the operator should be fully protected from exposure to radiation and use a dosimeter badge. - 3 -

COMPONENTS 1. X-ray Equipment (Model HF80/15+DLP) 1 set 2. Power Cord 1 pc. 3. Hand-held Exposure Switch and Cord 1pc. 4. Spare Fuse 2 pcs. 5. Instruction Manual 1 pc. 6. Carrying Case 1 pc. 7. Warranty Sheet 1 pc. - 4 -

OPERATING CONDITIONS A. Power Supply 1. Nominal supply voltage 230VAC 2. Safe range of fluctuations 200-260VAC in line voltage ( no load ) 3. Safe minimum line voltage (under load) 190VAC (230V model) 4. Rating of supply circuit 10A (230V model) 5. Phase and hertz Single phase, 50 or 60Hz DO NOT OPERATE IF USING ELECTRICAL OUTLET WITHOUT PROPER GROUND. B. Environmental Conditions for Use 1. Temperature 45 40 41 104 2. Humidity 30 85% 3. Atmospheric Pressure 70 106kPa (700-1060mbar) 4. Other Avoid using where explosive or corrosive gases are present. - 5 -

MAIN PARTS OF HF80/15+DLP Screw to adjust Laser point direction (horizontal) Collimator Angle indicator Screw to adjust Laser point direction (vertical) Level Tape measure Knob to adjust x-ray field size (horizontal) Connector for exposure switch Knob to adjust x-ray field size (vertical) Battery compartment Main power switch Fuse box Connector for power cord Exposure switch Power cord - 6 -

CONTROL PANEL OF HF80/15+DLP 1. X-ray Indicator 9. kv Adjustment Button (+) 2. Ready Indicator 10. sec/mas Adjustment (+) 3. Error Indicator 11. sec/mas Adjustment (-) 4. kv Indicator 12. Shift Button 5. Exposure time (sec)/ 13. Collimator light switch mas Indicator 14. Memory Storage Button 6. mas Indicator 15. Memory Recall Buttons (M1to M5) 7. sec Indicator 16. Level 8. kv Adjustment Button (-) - 7 -

LASER ALIGNMENT INSTRUCTIONS Before using the Dual Laser Pointer, you must adjust the position of the laser beam to be cross with the central ray of the x-ray unit at the source-to-image-distance (SID) you typically use. The adjustments can be made with a phillips (+) screwdriver. Set up the x-ray unit indoors at the SID that you typically use, to a wall or x-ray cassette. The adjustment screws for the laser beam are on the top and side of collimator. Turn on the collimator light and laser beam together by pressing the COLLIMATOR LIGHT ON BUTTON on the control panel, or the first stage of the EXPOSURE SWITCH. Make sure that the cross hair indicating the central ray is visible at this SID. Use the screwdriver to turn the adjustment screws for the laser beam to place the laser beam close to be a cross on the wall or x-ray cassette by the collimator at your typical SID. One adjustment screw adjusts the laser beam UP and DOWN. Turning this screw clockwise adjusts the laser beam DOWN. The other adjustment screw adjusts the laser beam RIGHT and LEFT. Turning this screw clockwise adjusts the laser beam LEFT. When you have finished adjusting the position of the laser beam, a cross hair of laser beam indicating on the wall or x-ray cassette. NOTE: Initially, the Laser Pointer has been adjusted to the central ray at a SID of 27.6"(70 cm). The Laser Point s adjustable distance is 19.7 (50cm) 39.4 (100cm). One adjustment screw adjusts the laser beam UP and DOWN. Turning this screw clockwise adjusts the laser beam DOWN. (The adjustment Screw is locate the side of collimator) The other adjustment screw adjusts the laser beam RIGHT and LEFT. Turning this screw clockwise adjusts the laser beam LEFT. (The adjustment Screw is locate the top of collimator) When you have finished adjusting the position of the laser beam, a cross hair of laser beam indicating on the wall or x-ray cassette. - 8 -

OPERATING PROCEDURES Connection Connect POWER CORD and EXPOSURE CORD to main body. Connect POWER CORD PLUG to grounded electrical outlet of proper voltage, amperage, and hertz. Check the rating label on your unit to confirm the proper input voltage. Operation 1. Press MAIN POWER SWITCH on the rear panel to the on position. Each digital display on the control panel will illuminate. The HF80/15+DLP is now ready to use. CAUTION DO NOT SWITCH THE MAIN POWER ON AND OFF QUICKLY IN A SHORT TIME WHEN TURNING ON AGAIN AFTER TURNING OFF, WAIT FOR AT LEAST 1 MINUTE. OTHERWISE THE HIGH FREQUENCY INVERTER CANNOT WORK PROPERLY. 2. Select the kv output by pressing the arrows below the kv display to choose 50kV to 80kV. ma output is fixed at 15 for all kv settings. 3. Set the exposure time for the view to be taken, and the imaging medium used. Press the arrows below the sec. display to choose the exposure time between 0.01 and 2.00 second exposures. The display can be changed between mas and sec. selected by pressing the shift button (#) and pressing the down arrow ( ) below the kv display. 4. Use the retractable tape measure to position the HF80/15+DLP at the proper source-image distance (SID) for the image to be taken. 5. Turn on the collimator light by pressing the button on the control panel. The light will remain on for approximately 45 seconds, and then automatically turn off. The shutters of the collimator can be adjusted at any time with the 2 knobs on the collimator. The size of radiation field will only be projected on the image receptor when the light is on. 6. Position the patient. Adjust the collimator position so the cross hair projected by the collimator light is aligned with the anatomical point of interest and the center of the image receptor. Collimate the size of the light field so that it stays within the dimensions of the image receptor. 7. Radiography Make sure that ERROR INDICATOR is off. The exposure switch has 2-stage button. - 9 -

The first stage pre-heats the filament of the x-ray tube. When this stage alone is depressed and held, the "READY" indicator will light after 2.5 seconds, indicating the filament was heated and the unit is ready to generate x-rays. The second stage initiates the x-ray exposure for the time set in the sec display. When the second stage is fully depressed, x-ray will be emitted, the X-RAY indicator will light, and an audible signal will be heard. PRESS AND HOLD THE FIRST AND SECOND STAGE BUTTONS TOGETHER UNTIL THE EXPOSURE HAS TERMINATED. This is a "dead man" exposure switch -- x-ray exposure will terminate immediately as a safety feature when the buttons are released. It is possible to depress the two stage buttons simultaneously. When this is done, there is approximately a 2.5 second delay before the timed x-ray exposure begins. 8. After each exposure, release the exposure buttons. The HF80/15+DLP is now ready for the next exposure. Error lamp will blink if the exposure switch is released before the set exposure time. Turn off the MAIN POWER SWITCH, wait 1 minute, then start procedures over again. Operation Note: To insure maximum life of x-ray tube and to avoid interruption of operation, do not exceed duty cycle of 1:30. 9. When you are finished using the HF80/15+DLP, turn off the main power switch. All of the indicators on the control panel will turn off after several seconds. 10. Five different technique settings can be stored in memory for quick recall on the HF80/15+DLP. To store a technique setting, press the Memory Storage button MR then press Memory Recall button M1. This will store the technique setting displayed in memory position M1. Repeat this process for storing the different technique setting in M2-M5 as desired. Stored technique settings can be easily recalled by simply pressing M1-M5. 11. Memory Storage use two (2) size AA alkaline batteries inside Battery Compartment, located on the back side of equipment. Open the Battery Compartment using a coin, turning the compartment lid counterclockwise 90. If there are no batteries in the Battery Compartment, use some adhesive tape to help you remove the compartment lid. Insert two (2) size AA alkaline batteries in the Battery Compartment, with the + end toward the Battery Compartment lid. Reattach the Battery Compartment lid and lock it with a coin, turning it clockwise 90. Close Open Pull - 10 -

ERROR INDICATOR Your HF80/15+DLP has an ERROR INDICATOR. If the ERROR INDICATOR is on, stop exposing and follow the step below. The unit has malfunctioned and x-ray cannot be generated. If ERROR INDICATOR is lit even after the EXPOSURE SWITCH is released, it means an unusual situation has occurred. Turn off the MAIN POWER SWITCH, wait 3 minutes, then start procedures over again. If the ERROR INDICATOR remains on, contact your dealer or Gierth for service. - 11 -

HF80/15+DLP Specifications Rating Power Requirement AC, single phase, 230V Maximum Output 80kVDC, 15mA, 2.00 sec. Line Voltage Regulation 4.8% Input Current Stand by: 0.185A Momentary: 13.0A Protection Against Electrical Shock Fuse Type B, Class I 15A @ 250V X-ray Generator Output 15mA @ 50-80kVDC Timer Ultra high resolution 0.01-2.00 sec. Internal Power Supply Constant potential, 60kHz Line Voltage Adjustment Automatic X-ray Tube SNMI Focal Spot 1.0 mm Anode Heat Storage 7kHU Total Filtration 3.0 mm Al equivalent (with collimator) 2.5mm Al equivalent (without collimator) Collimator Mikasa R-200V type J04 continuously adjustable light beam type with central ray indicator and adjustable dual laser pointers Dual Laser Pointers (model LP4) Laser type: Class IIIa Laser Diode Maximum output: < 5.0 mw Wave length: 600-680nm Beam length: 15mm at 60cm Power 12VDC Exposure Cord 2.5 meters Exposure Switch Two stage, deadman type Power Cord 6.0 meters Size 18.2cm W x 15.0cm H x 31.0cm L Weight 6.56 kgs. Applications Equine and large animal veterinary radiography Duty cycle 1:30 Specifications subject to revision without notice. - 12 -