AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Similar documents
AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

AC/DC MAGNETIC METER

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

OPERATION MANUAL. SD card real time Data Recorder SOLAR POWER METER. Model : SPM-1116SD

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

OPERATION MANUAL. SD card real time datalogger HUMIDITY/TEMP. MONITOR. Model : MHT-381SD

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

DIGITAL ANEMOMETER Model : AM-4203

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

UVA LIGHT METER OPERATION MANUAL. Model : UVA-365SD. SD card real time datalogger + Type K/J thermometer

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

VACUUM METER Model : VC-9200

VIBRATION METER Model : VB-8213

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD

OPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD

600 g x 0.02 g DIGITAL BALANCE

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

PRESSURE METER OPERATION MANUAL. Model : PS-9302

SD card real time data logger TDS ( Total dissolved solids ), Salt '20 us/200 us/2 ms/20 ms/200 ms CONDUCTIVITY METER.

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

OPERATION MANUAL. SD card real time datalogger HEAT INDEX WBGT METER. Model : WBGT-2010SD

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

OPERATION MANUAL. SD card real time data logger DISSOLVED OXYGEN METER. Model : DO-5512SD

DATALOGGER. SD card, real time OPERATION MANUAL. Model : DL-9602SD

MOISTURE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. 3, Hagavish st. Israel Tel: , Fax:

UV LIGHT METER UVC-254

TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

LIGHT METER OPERATION MANUAL. auto range 0 to 50,000 Lux, 3 ranges. Model : LX-113S

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

Manual Digital Thermometer PCE-T 390

VB Model. Instruction Manual. Vibration Meter. reedinstruments. www. com

HOT WIRE ANEMOMETER. Model : 204HA

VANE ANEMOMETER HUMIDITY/TEMP.

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS General Specifications Electrical Specifications...3

USER GUIDE. AC/DC Magnetic Meter. Model MF100

TU-2016 TURBIDITY METER

Torque Meter. Instruction Manual

SD card real time datalogger, RS232/USB Frequency weighting and Time weighting meet IEC class 2, Personal sound exposure meet IEC 61252

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

SOIL MOISTURE METER OPERATION MANUAL. Model : DSMM500. Your purchase of this

MOISTURE METER OPERATION MANUAL. all in one. Model : PMS-713

Light Meter with Bar Graph

Clamp meter with Data recorder SERIES set

RH/Temperature SD Card Datalogger. Instruction Manual

Manual ph Meter PCE-228

SD Model. Instruction Manual. Sound Level Meter/ Data logger. reedinstruments. www. com

SD Model. Instruction Manual. Heat Stress Meter and Datalogger. reedinstruments

Datalogging Hot Wire CFM Anemometer

Anemometer SD Card Datalogger. Instruction Manual

LIGHT METER OPERATION MANUAL. Model : LM-81LX

MMD7003 USER S MANUAL. DIGITAL and LED PRECISION MOISTURE METER

Visible Light SD Card Datalogger

VANE ANEMOMETER BAROMETER HUMIDITY/TEMP. Model : ABH-4225

Heavy Duty Hot Wire CFM Thermo-Anemometer

4 in 1 Anemometer, Humidity Light Meter, Thermometer

OPERATION MANUAL. SD card real time datalogger ph, ORP, CD, TDS, DO, SALT METER. Model : WA-2017SD

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

LIGHT METER. Model : LM-81LX. Digital Measurement Metrology, Inc Digital Measurement Metrology, Inc

Datalogging Conductivity/ TDS Meter. Instruction Manual

Laser, PHOTO TACHOMETER RS

INSTRUCTION MANUAL. Models: H100 Light Meter

TORQUE METER Model : TQ-8800

Pen type, with separate electrode PH METER Model : PH-220 OPERATION MANUAL

9 in 1 Anemometer, Humidity/Temp. meter, Light meter Pt 1000 Temp. ( optional ) Sport/Weather meter ENVIRONMENT METER Model : SP-8001

3 Channel Datalogging Thermometer

DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T

Barometric Pressure / Humidity and Temperature Datalogger

Hygro-Thermometer / Datalogger

Anemometer, Hygrometer Light Meter, Thermometer

Datalogging Hygro-Thermometer

User's Guide. Datalogging Hygro-Thermometer Model SD500

Vibration Meter SD Card real-time datalogger

User's Guide. 3 Channel Datalogging Thermometer Model SD200

WBGT SD Card Datalogger. Instruction Manual

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Instruction Manual Force Gauge, Kg

Datalogging Hygro-Thermometer

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

PH SD Card Datalogger. Instruction Manual

Transcription:

G ( Gauss), mt ( milli Tesla ), USB/RS232 AC/DC MAGNETIC METER Model : PCE-MFM 3000 Your purchase of this AC/DC MAGNETIC METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate instrument, its durable structure will allow many years of use if proper operating techniques are developed. Please read the following instructions carefully and always keep this manual within easy reach. OPERATION MANUAL

TABLE OF CONTENTS 1. FEATURES...1 2. SPECIFICATIONS...2 3. FRONT PANEL DESCRIPTION... 4 3-1 Display...4 3-2 Power Button... 4 3-3 Hold Button...4 3-4 REC Button... 4 3-5 ZERO Button...4 3-6 Mode Button ( DC, AC Button )...4 3-7 Input socket...4 3-8 Probe Handle...4 3-9 Probe Sensing Head...4 3-10 Probe Plug...4 3-11 Probe Head Cover...4 3-12 RS-232 Output Terminal...4 3-13 Reset button...4 3-14 DC 9V Power Adapter Input Socket...4 3-15 Stand...4 3-16 Tripod Fix Nut... 4 3-17 Battery Compartment/Cover...4 3-18 Battery Cover Screw...4 4. MEASURING PROCEDURE...5 4-1 Measurement consideration... 5 4-2 AC/DC magnetic field measurement...6 4-3 Data Hold...8 4-4 Data Record...8 5. ADVANCED MEASURING PROCEDURE...9 5-1 Auto power ON/OFF management...10 5-2 Change the unit ( mt, G )...10 6. RS232 PC SERIAL INTERFACE...11 7. BATTERY REPLACEMENT...12 8. SYSTEM RESET...13

1. FEATURES * Wide range, general purpose magnetic measurement. for industrial, mechanical, material, electrical, laboratory field usage. * Unit : G ( Gauss ), mt ( milli Tesla ). * DC and AC magnetic field measurement * DC Range : 300.00 mt/3000.0 mt. AC Range : 150.00 mt/1500.0 mt. * Resolution : 0.01/0.1 mt, 0.1/1 G. * N pole/s pole indicator. * Use Hall sensor with automatic Temp. compensation. * Zero button for DC magnetic function. * Separate probe, easy operation and convenient for remote measurement. * Data hold function for freezing the desired value on display. * Records Maximum and Minimum readings with Recall. * RS232/USB computer interface. * Microprocessor circuit assures maximum possible accuracy, provides special functions and features. * Heavy duty & compact housing with hard carrying case, designed for easy carry out & operation. * Auto shut off is available to save battery life. * Power supply from batteries or DC 9V adapter in. 1

2. SPECIFICATIONS Circuit Custom one-chip of microprocessor LSI circuit. Display LCD size : 52 mm x 38 mm dual function LCD display. Measurement mt milli Tesla Unit G Gauss Measurement mt Range 1 300.00 mt x 0.01 mt Range, DC Range 2 3,000.0 mt x 0.1 mt G Range 1 3,000.0 G x 0.1 G Range 2 30,000 G x 1 G Measurement mt Range 1 150.00 mt x 0.01 mt Range, AC G Range 2 1,500.0 mt x 0.1 mt Range 1 1,500.0 G x 0.1 G Range 2 15,000 G x 1 G Accuracy DC ± ( 5 % rdg. + 10 digit ) AC ± ( 5 % rdg. + 20 digit ) Frequency AC measurement : Response 50 Hz / 60 Hz Sensor Hall sensor. Temp. Probe head build the Temp. sensor Compensation for using the ATC ( automatic Temp. for hall sensor compensation ). Field Direction Uniaxial. Data Hold Freeze the display reading. Memory Recall Maximum & Minimum value. Display Approx. 1 second. Sampling Time Power off Manual off by push button or Auto shut off to save battery life. Operating 0 to 50. Temperature Operating Less than 85% R.H. Humidity 2

Data Output Power Supply RS 232/USB PC serial interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug. * Connect the optional USB cable USB-01 will get the USB plug. 006P DC 9V battery ( Alkaline or Heavy duty type ). DC 9V adapter input. * AC/DC power adapter is optional. Power Current Approx. DC 20.5 ma. Weight Approx. 270 g/0.60 LB. ( include battery & probe ) Dimension Main instrument : 195 x 68 x 30 mm ( 7.6 x 2.6 x 1.2 inch ) Probe : 198 x 25 x 19 mm ( 7.8 x 1.0 x 0.7 inch ). Accessories Included Optional Accessories Instruction manual...1 PC Magnetic Probe...1 PC Carrying case, CA-06...1 PC RS232 cable, UPCB-02 USB cable, USB-01 Data Acquisition software, SW-U801-WIN * Above specification tests under the environment RF Field Strength less than 3 V/M & frequency less than 30 MHz only. 3

3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-2 Power Button 3-3 Hold Button 3-4 REC Button ( Enter Button ) 3-5 ZERO Button 3-6 Mode Button ( DC, AC Button ) 3-7 Input socket 3-8 Probe Handle 3-9 Probe Sensing Head 3-10 Probe Plug 3-11 Probe Head Cover 3-12 RS-232 Output Terminal 3-13 Reset button... 3-14 DC 9V Power Adapter Input Socket 3-15 Stand 3-16 Tripod Fix Nut 3-17 Battery Compartment/Cover 3-18 Battery Cover Screw 4

4. MEASURING PROCEDURE 4-1 Measurement Consideration 1) Display indicator : DC magnetic field measurement * North pole : Display will show " N " indicator * South pole : Display will show " S " indicator AC magnetic field measurement * Display will show " AC " indicator. 2)Probe head sensing area and the sensing direction : Magnetic sensing area Magnetic sensing direction Fig. 2 5

4-2 AC/DC magnetic field measurement 1)Power ON the meter by pressing the " Power Button " ( 3-2, Fig. 1 ) once. 2)Press the " Mode Button " ( 3-6, Fig.1 ) once, the Display will show the following screen in sequence : Under mt unit Under G unit 0 a1 0 a2.0 0 0.0 b1 0 b2 0.0 0 c1 0 c2.0 AC 0 AC 0.0 d1 0 d2 0 AC.0 AC Note : a1 screen is ready for DC 0.1 mt resolution measurement. b1 screen is ready for DC 0.01 mt resolution measurement. c1 screen is ready for AC 0.1 mt resolution measurement. d1 screen is ready for AC 0.01 resolution measurement. a2 screen is ready for DC 1 G resolution measurement. b2 screen is ready for DC 0.1 G resolution measurement. c2 screen is ready for AC 1 G resolution measurement. d2 screen is ready for AC 0.1 G resolution measurement. 6

4) unit selection : How to select the unit ( mg, ut ), the procedures please refer to chapter 5-1 " Change the unit ( mt, G ) ", page. 5) Contact and close the testing material to the probe head ( refer to Fig. 3 ), the Display will show the magnetic field value along with the unit ( mg, ut ). Magnetic sensing direction Fig. 3 7

6) Zero adjustment : When power ON the meter, due to the environment interference, the display may show certain values ( not zero value), it is normal. * Before the measurement, fix the probe at the exact position, press the " ZERO Button " ( 3-5, Fig. 1 ) continuously at least two seconds until the display show " 0 " value, in the same time the Display will show the " 0 " indicator then release the finger from the button. * Press the " ZERO Button " ( 3-5, Fig. 1 ) continuously at least two seconds again, the " O " indicator will be disappeared and the Display will return to the " no zero " value ( show the environment magnetic field value ). 4-3 Data Hold During the measurement, press the " Hold Button " ( 3-3, Fig. 1 ) once will hold the measured value & the LCD will display a " HOLD " symbol. * Press the " Hold Button " once again will release the data hold function. 4-4 Data Record ( Max., Min. reading ) * The data record function records the maximum and minimum readings. Press the " REC Button " ( 3-4, Fig. 1 ) once to start the Data Record function and there will be a " REC " symbol on the display. * With the " REC " symbol on the display : a) Press the " REC Button " ( 3-4, Fig. 1 ) once, the " REC. MAX " symbol along with the maximum value will appear on the display. If intend to delete the maximum value, just press the " Hold Button " ( 3-3, Fig. 1 ) once, then the display will show the " REC. " symbol only & execute the memory function continuously. 8

b)press the " REC Button " ( 3-4, Fig. 1 ) again, the " REC. MIN " symbol along with the minimum value will appear on the display. If intend to delete the minimum value, just press the " Hold Button " ( 3-3, Fig. 1 ) once, then the display will show the " REC. " symbol only & execute the memory function continuously. c) To exit the memory record function, just press the " REC Button " for 2 seconds at least. The display will revert to the current reading. Remark : The Max. ( Min. ) value is to present the value of the absolute measurement value ( forget the negative mark ), for example if the measurement value is -19,03 mt, -19. 02 mt, -17.31 mt, then the Max. value is -19,03 mt due to the negative label is just the to show the direction of " South pole " only. 5. ADVANCED SETTING Press the " SET Button " ( 3-6, Fig. 1 ) continuously at least two seconds will enter the " Advanced Setting " mode, then press the " SET Button " ( 3-6, Fig. 1 ) once a while in sequence to select the two function, the lower Display will show : PoFF...Auto power OFF management Unit...Select the measurement unit to mt or G 9

5-1 Auto power OFF management When the lower display show " PoFF " 1)Use the " AC/DC Button " ( 3-5, Fig. 1 ) or " RANGE Button " ( 3-6, Fig. 1 ) to select the upper value to " yes " or " no ". yes - Auto Power Off management will enable. no - Auto Power Off management will disable. 2)After select the desiring function ( YES or no ), press the " REC Button " ( 3-4, Fig. 1 ) to save the function with default. 5-2 Select the measurement unit to mt or G When the lower display show " unit " 1)Use the " AC/DC Button " ( 3-5, Fig. 1 ) or " RANGE Button " ( 3-6, Fig. 1 ) to select the Display indicator to " mt " or " G ". mt - milli Tesla G - Gauss 2)After Display unit is selected to " mt " or " G ", press the " REC Button " ( 3-4, Fig. 1 ) will save the setting function with default. 10

6. RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3.5 mm terminal ( 3-11, Fig. 1 ). The data output is a 16 digit stream which can be utilized for user's specific application. A RS232 lead with the following connection will be required to link the instrument with the PC serial port. Meter PC (3.5 mm jack plug) (9W 'D" Connector) Center Pin...Pin 4 Ground/shield...Pin 2 Pin 5 2.2 K resister The 16 digits data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 11

Each digit indicates the following status : D15 Start Word = 02 D14 4 D13 1 D12 & Annunciator for Display D11 mg = B3 G = B5 D10 Polarity 0 = Positive 1 = Negative D9 Decimal Point(DP), position from right to the left, 0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP D8 to D1 Display reading, D8 = MSD, D1 = LSD For example : If the display reading is 1234, then D8 to D1 is : 00001234 D0 End Word = 0D RS232 setting Baud rate 9600 Parity No parity Data bit no. 8 Data bits Stop bit 1 Stop bit 7. BATTERY REPLACEMENT 1)When the left corner of LCD display show " ", it is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2)Loose the " Battery Cover Screw " ( 3-18, Fig. 1 ), slide the " Battery Cover " ( 3-17, Fig. 1 ) away from the instrument and remove the battery. Replace with DC 9 V battery ( 006P Alkaline/heavy duty ), and reinstate the cover. 3) Make sure the battery cover is secured after changing the battery. 12

8. SYSTEM RESET If the meter happen the troubles such as : CPU system is hold ( for example, the key button can not be operated... ). Then make the system RESET will fix the problem. The system RESET procedures will be either following method : During the power on, use a pin to press the " Reset Button " ( 3-13, Fig. 1 ) once a while will rest the circuit system, After execute the " System reset " the setting value of : Advanced Setting " will be cleared and return to default value. 13 1002