M57 Profibus DP Master Interface

Similar documents
M82 16 Binary Inputs. Embedded Solutions for Transportation and Industrial Markets

M81 16 Binary Outputs

M35N 8/16 Analog Inputs, 14 Bits

G211F 3U CompactPCI Serial Quad Fiber Optics Interface

M77N Mezzanine Card with 4 UARTs

GM2 Octal Gigabit Ethernet Rear I/O Card

PU4 3U 8 HP Power Supply Unit PSU, 72 to 110 VDC, 35 W

F223 3U CompactPCI PCIe Mini Card Carrier for Wireless Functions

PU5 3U 12 HP Power Supply Unit PSU, 110 VDC, 100 W

F701 3U CompactPCI MVB Interface Card

D302-6U CompactPCI Card with 128 Binary I/Os

SF4 3U 19" Industrial Ethernet Switch

G229 Serial I/O Expansion Board

P517 - Graphics Accelerator PMC

NM10 Smart Managed 8-Port Railway Ethernet Switch

NM11 Smart Managed 8-Port Rugged PoE Switch

PX4 Mobile Phone Voice Interface PCI Express Mini Card

MH70I Rugged 19" Modular Industrial PC

CM10 Rugged COM Express with TI Sitara ARM Cortex-A15

RS4 IP67 Industrial Ethernet Switch

DC13 Rugged 8.4" Panel PC with Front Keys

CB70C Rugged COM Express (VITA 59 RCE) with Intel Core i7

F305 Quad Fast Ethernet / Real-Time Ethernet Interface

DC13 Rugged 8.4" Panel PC with Front Keys

G52A. QorIQ Enhanced Network CPU Board. Data Sheet. CompactPCI Serial

XC15 Rugged COM Express Evaluation Carrier Board

B6-3U VMEbus 68k Communication Controller

PX1 GLONASS & GPS PCI Express Mini Card

B12-3U VMEbus PowerPC SBC

A17 Embedded Single Board Computer with PowerPC MPC8548

A23C TI Sitara ARM Cortex-A15 CPU

G51 3U CompactPCI Serial QorIQ Communications CPU Board

EM02 - ESM with Pentium III

ME1 DIN Rail Wireless Communication Component

EK01 - ESM Starter Kit with Pentium III

DC17 Rugged 12.1" Panel PC

D601 - Conduction-Cooled 6U CPCI Pentium M SBC

EM07 - ESM with Pentium III / Celeron

BE10A Entry-Level Box PC for Industrial Applications

F302-3U CompactPCI Managed 8+1-Port Eth. Switch

SC27 Intel Atom SBC for Intelligent Displays

D4-6U CompactPCI Pentium 4 SBC

A21C Embedded Single Board Computer, QorIQ P1xxx, PMC/XMC

F4-3U CompactPCI PowerPC Peripheral SBC

CB71C Rugged COM Express Module with AMD V1000

BC50F Rugged Box PC for Industrial Automation with AMD G-Series

D4-6U CompactPCI /PXI Pentium 4 SBC

DC2 Rugged 10.4" Touch Panel PC

F9-3U CompactPCI Pentium M SBC

NM50 Mobile Gateway & WLAN Access Point

BC51M Rugged Industrial Box PC with Intel Apollo Lake-I

DC15 Rugged 10.4" Panel PC with Front Keys or Touch Screen

20F E F217 3U CompactPCI Memory Card Carrier. Embedded Solutions. Configuration example. User Manual

D3B - 6U CompactPCI MPC8245 SBC / M-Module

A12C - 6U VMEbus MPC8245 SBC / PMC

A15C - 6U VME64 MPC8245 SBC / PMC

F9-3U CompactPCI PentiumM SBC

SC27 Intel Atom SBC for Intelligent Displays

BL51E Rugged Box PC for Transportation with Intel Apollo Lake-I

BC50I Rugged Box PC for Industrial Automation with AMD G-Series

F18-3U CompactPCI /Express Core 2 Duo SBC

A15a - 6U VME64 PowerPC SBC with PC-MIPs

EM04 - ESM with PowerPC MPC 8245

F9-3U CompactPCI PentiumM SBC

G211F 3U CompactPCI Serial Quad Fiber Optics Interface

NM50 IOT & Gateway Computer or WLAN Access Point

F7-3U/6U CompactPCI/PXI Pentium III SBC

F18-3U CompactPCI /Express Core 2 Duo SBC

F9-3U CompactPCI/PXI Pentium M SBC

BC50M Rugged Box PC for Transportation with AMD G-Series

F17-3U CompactPCI /Express Core 2 Duo SBC

BL70W Rugged Box PC for Transportation with Intel Core i3 / i5 / i7

G22 3U CompactPCI Serial Intel Core i7 CPU Board

20AD67-00 E AD67 6U I/O Extension for A12, A15, D3, SC13. Embedded Solutions. Configuration example. User Manual

RS1 IP67 Industrial Ethernet Switch

NM30 Managed 8-Port Rugged Industrial Ethernet Switch

PX7. User Manual. PCIe Mini Card to M.2 Adapter. PCI Express Mini Card

NM31 Fully Managed 8-Port Industrial Ethernet Switch with PoE

EM8 - ESM with PowerPC MPC8540 (PowerQUICC III)

BC50M Box PC for In-Vehicle Applications

20G E G215 3U CompactPCI Serial Universal Interface Board. Embedded Solutions. Configuration example.

BL50S Rugged Box PC for Storage Applications (AMD)

NUF2221W1T2. USB Upstream Terminator with ESD Protection

NM10. Unmanaged 8-Port Rugged Ethernet Switch. User Manual

NP0080TA Series. Low Capacitance Protector

Hardware Documentation

M68HC705E24PGMR PROGRAMMER USER'S MANUAL

CM1219. Low Capacitance Transient Voltage Suppressors / ESD Protectors

NUP4114UCW1T2G. Transient Voltage Suppressors. ESD Protection Diodes with Low Clamping Voltage

Headset/Speaker EMI Filter with ESD Protection CM1416/D. Features. Product Description. Applications. ±30kV ESD protection on each channel per

M68HC705E6PGMR PROGRAMMER USER'S MANUAL

UniFinger SFM5060-OH

Freescale Semiconductor, I

IEXT224-4PH-L IEXT224-4PH-R Long Reach POE Extenders

AND8319/D. How to Maintain USB Signal Integrity when Adding ESD Protection APPLICATION NOTE

Device Errata MPC860ADS Application Development System Board Versions ENG, PILOT, REV A

CM DE. 4-Channel LCD and Camera EMI Filter Array with ESD Protection

CM1621. LCD and Camera EMI Filter Array with ESD Protection

NZQA5V6AXV5 Series. Transient Voltage Suppressors

NUP2114 Series, SNUP2114UCMR6T1G Transient Voltage Suppressors Low Capacitance ESD Protection for High Speed Data

Transcription:

M57 Profibus DP Master Interface Class 1/2 Profibus DP master (DIN19245) Isolated RS485, RS232 (debug) interface Local 32-bit CPU Up to 127 active or passive stations 12 Mbit/s data transfer rate 1 MB DRAM Complete Softing Profibus software on board Compatible with PROFIBUS DP Configurator The M57 is a Profibus DP (Distributed Peripherals) interface. The M-Module is based on the ASPC 2 controller and the 16-MHz Motorola MC68331 CPU. It is an ideal interface solution for intelligent remote I/O applications via a very popular fieldbus standard. The ASPC 2 is an advanced Profibus controller allowing 127 stations with 254 SAPs (Service Access Points) each. It allows data transfer rates of up to 12 Mbaud on the M57. The mezzanine card MC68331 is a 68020-based CPU which handles communication with the host CPU via the on-board 1 MB of shared DRAM. The advantage of this Profibus application using the MC68331 is that the complete Profibus protocol stack runs locally on the M- Module with very reduced interaction of the host CPU. The Profibus firmware consists of the true Softing protocol stack. The corresponding driver software comes from MEN and complies with the standard Softing PROFIBUS DP Configurator tool. It supports configuration of the M57 for each application in a very convenient way. The driver is based on MDIS (MEN Driver Interface System) which makes the M57 ready for use under Windows, Linux and RTOS environments. The optically isolated RS485 Profibus interface is supplied by an onboard DC/DC converter. The M57 is based on the M-Module ANSI mezzanine standard. It can be used as an I/O extension in any type of bus system, i.e. CPCI, VME or on any type of stand-alone SBC. Appropriate M-Module carrier cards in 3U, 6U and other formats are available from MEN or other manufacturers. M57 Data Sheet / 2012-04-02 Page 1

Diagram M57 Data Sheet / 2012-04-02 Page 2

Technical Data MC68331/16MHz CPU ASPC 2 Profibus Controller Miscellaneous Peripheral Connections M-Module Characteristics Electrical Specifications Mechanical Specifications Environmental Specifications Safety EMC Software Support CPU32 performance Complete Profibus DP software on one M-Module Local interrupt controller Hardware watchdog Up to 12Mbaud data rate 16-bit DMA interface (local) Complete bus access protocol Up to 127 active or passive stations 1MB shared memory for communication and program Fast M-Module interface with autoincrement address mode Status LEDs Isolated Profibus interface Via front panel on a shielded 9-pin D-Sub receptacle connector A08, A24, D16, INTA, IDENT Isolation voltage: 500V DC Supply voltage/power consumption: +5V (4.85V..5.25V), 800mA typ. MTBF: 45,000h @ 50 C (derived from MIL-HDBK-217F) Dimensions: conforming to M-Module Standard Weight: 92g Temperature range (operation): 0..+60 C Industrial temperature range on request Airflow: min. 10m³/h Temperature range (storage): -40..+85 C Relative humidity range (operation): max. 95% non-condensing Relative humidity range (storage): max. 95% non-condensing Altitude: -300m to + 3,000m Shock: 15g/11ms Bump: 10g/16ms Vibration (sinusoidal): 2g/10..150Hz Conformal coating on request PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers Tested according to EN 55022 (radio disturbance), IEC1000-4-2 (ESD) and IEC1000-4-4 (burst) Softing protocol portation (ISO/OSI protocol layer 2/DP) MEN Driver Interface System (MDIS for Windows, Linux, VxWorks, QNX, OS-9 ) M57 Data Sheet / 2012-04-02 Page 3

Ordering Information Standard M57 Models 04M057-00 Profibus DP interface, 0..+60 C Miscellaneous Accessories 05M000-17 25 mounting screw sets to fix M-Modules on carrier boards Software: Linux This product is designed to work under Linux. See below for potentially available separate software packages from MEN. Software: Windows This product is designed to work under Windows. See below for potentially available separate software packages from MEN. 13M057-70 MDIS4/2004 / MDIS5 Windows driver (MEN) for M57 and P6 Software: VxWorks This product is designed to work under VxWorks. For details regarding supported/unsupported board functions please refer to the corresponding software data sheets. Software: QNX This product is designed to work under QNX. For details regarding supported/unsupported board functions please refer to the corresponding software data sheets. Software: OS-9 This product is designed to work under OS-9. For details regarding supported/unsupported board functions please refer to the corresponding software data sheets. Software: Miscellaneous For use of the MDIS4 driver you also need the Softing PROFIBUS DP Configurator tool. You will find more information on this tool and a demo version at www.softing.de. For operating systems not mentioned here contact MEN sales. Documentation Compare Chart fieldbus M-Modules» Download 20M000-00 M-Module Draft Specification, Rev. 3.0 20M057-00 M57 User Manual M57 Data Sheet / 2012-04-02 Page 4

Contact Information Germany MEN Mikro Elektronik GmbH Neuwieder Straße 3-7 90411 Nuremberg Phone +49-911-99 33 5-0 Fax +49-911-99 33 5-901 info@men.de www.men.de France MEN Mikro Elektronik SAS 18, rue René Cassin ZA de la Châtelaine 74240 Gaillard Phone +33 (0) 450-955-312 Fax +33 (0) 450-955-211 info@men-france.fr www.men-france.fr USA MEN Micro Inc. 860 Penllyn Blue Bell Pike Blue Bell, PA 19422 Phone (215) 542-9575 Fax (215) 542-9577 sales@menmicro.com www.menmicro.com The date of issue stated in this data sheet refers to the Technical Data only. Changes in ordering information given herein do not affect the date of issue. All brand or product names are trademarks or registered trademarks of their respective holders. MEN is not responsible for the results of any actions taken on the basis of information in the publication, nor for any error in or omission from the publication. MEN expressly disclaims all and any liability and responsibility to any person, whether a reader of the publication or not, in respect of anything, and of the consequences of anything, done or omitted to be done by any such person in reliance, whether wholly or partially, on the whole or any part of the contents of the publication. The correct function of MEN products in mission-critical and life-critical applications is limited to the environmental specification given for each product in the technical user manual.the correct function of MEN products under extended environmental conditions is limited to the individual requirement specification and subsequent validation documents for each product for the applicable use case and has to be agreed upon in writing by MEN and the customer.should the customer purchase or use MEN products for any unintended or unauthorized application, the customer shall indemnify and hold MEN and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim or personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that MEN was negligent regarding the design or manufacture of the part. In no case is MEN liable for the correct function of the technical installation where MEN products are a part of. Copyright 2014 MEN Mikro Elektronik GmbH. All rights reserved. M57 Data Sheet / 2012-04-02 Page 5