MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

Similar documents
MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

MiCOM P12x/y AREVA T&D. Three phase and earth fault overcurrent relays

MiCOM P521. Fast Feeder Differential Protection

MiCOM P521. Fast feeder differential protection

MiCOM P521. Fast Feeder Differential Protection. Protection Relays. MiCOM P521 CUSTOMER BENEFITS

MiCOM P122C Time-Overcurrent Protection

Three phase and earth fault overcurrent relays

MiCOM P12x/y. Three phase and earth fault overcurrent relays

MiCOM P220, P225 and P226C

MiCOM P111. Three phase and earth fault overcurrent relays

MiCOM P14x AREVA T&D. Feeder Management Relays

VIP 40/45 VIP 400/410

MiCOM P123R. Overcurrent Relays P123R/EN AD/A11. Upgrade Documentation

MiCOM P111 Numerical three phase and earth fault overcurrent relay description

GRD110 FEATURES APPLICATION

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

MiCOM P721 & P723. Numerical High Impedance Differential Relay. Protection Relays. Customer Benefits

MiCOM P14x. Feeder Management Relays

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

VAMP 11F. Overcurrent Protection Relays. Protection

Protection relay for secondary distribution

MiCOM P13x AREVA T&D. Feeder Management Relays

Reyrolle Protection Devices. 7SR10 Argus User Manual Overcurrent and Earth Fault Relay

MiCOM P139 Feeder Management and Bay Control

MiCOM P14x. Feeder Management Relays. Protection Relays

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

Content FPC 200. USER MANUAL Mar Feeder F1 and F3 Motor M1 and M3 Busbar B2 and B3 Transformer T1 and T3

Content FPC 400. USER MANUAL Apr Feeder F3 Motor M4 Busbar B3 Transformer T4

NPW800R RETROFITTING. Power and Volatge Protection Relay

GE Multilin 350 Feeder Protection Relay Specifications

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

MiCOM Agile P541 & 542. Grid Solutions. High-speed current differential unit protection. Key Benefits. Key Features. Current Differential Protection

Feeder Protection Relay REF 610. Product Guide

7SR11 and 7SR12 Description of Operation

INSTALLATION & COMMISIONING GUIDE

SACE Emax 2 Specification guide

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

GRE120. Motor Protection and Control for MV Systems

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Reyrolle Protection Devices. 7SR11 and 7SR12 Argus Overcurrent Relays. Answers for energy

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

SIA C. Self-powered overcurrent relay USER MANUAL

(1) Description of Operation 7SR224 Recloser Controller

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

GRE110. Protection and Control for MV Systems

7SR11 & 7SR12 Argus Overcurrent Relay Energy Management

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

MiCOM Agile P746. Grid Solutions. Key Benefits. Numerical Busbar Protection. A Combination of Speed, Security and Selectivity. About MiCOM P40 Agile

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

RMS Product Presentation

Products Portfolio. Pole mounted Vacuum Recloser

Circuit Breaker Operation & its load calculations

7SR18 Solkor Line Differential Protection Energy Management

Protection Relays PHASE & RESIDUAL OVERCURRENT

GRD130 - FEATURES APPLICATION

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

SDR recloser. A PH Fault B PH Fault C PH Fault. Ground Fault. SGF Lockout Aux Power OK. Recloser OK

Substation Automation Products. Line differential protection RED670 Relion 670 series

MiCOM P342/3/4/5 Generator Protection Relays

2C138. Sensitive Earth Fault Relay. Features. Application. Operation

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Earth-fault Relay SPAJ 110 C. Product Guide

Content REF615 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection

Protection relays.

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Feeder protection relay

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

Reyrolle Protection Devices. 7SG13 Delta Protection and Control Relays. Answers for energy

WiAutoLink Frequently Asked Questions

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES

Section 4 Ground-Fault Protection Devices

RF119. w w w. r m s p l. c o m. a u R F 119 B 4 08/ 01/

Reyrolle Catalogue Answers for Energy

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

MiCOM Agile P99x. Grid Solutions. Testing & Commissioning. Test Block, Multi-finger Test Plug and Single-finger Test Plug. Design Flexibility

FP5000. Refer to for the latest information on this constantly evolving product

Feeder/ Motor Protection Relay VAMP 40

Feeder protection relay SPAA 341 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide

4. CIRCUIT BREAKERS. Functional Emergency Switching

GRE130. Protection and Control for MV Systems

AUGUST 2001 APPLICATION AND COMMISSIONING MANUAL MIT161 RELAY EASUN REYROLLE LIMITED

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication

RELAYABLE POWER. AQ-200 series protection, control, measurement and monitoring IEDs

Reyrolle Protection Devices. 7SR10 Argus Overcurrent and Earth Fault Relay

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation

Transcription:

PROTECTION MiCOM P124 Self and Dual Powered Overcurrent Relays MiCOM P124 are numerical relays designed to offer complete overcurrent protection without requiring any external auxiliary supply. They can be applied to a wide variety of high and medium voltage electrical systems as either main or backup protection. MiCOM P124 self-powered model Available in a self-powered or in a dual-powered version, they offer three phase and earth fault protection. When supervision functions are required, the dual-powered version offers additional measurement, monitoring and recording functions. Numerous integrated communication protocols are available for flexible integration in most substation control or SCADA systems. The user-friendly operator interface allows easy reading of measured values and simple configuration of the relay. Associated accessories (low energy striker, battery box or capacitor trip unit) are also available to fit your particular application. MiCOM P124 dual-powered model Housed in a 4U metal case, it can be easily mounted in a panel or in a rack. Customer Benefits No auxiliary power required Simple and cost efficient solution Complete and fully safe protection Self or dual powered Additional measurement, monitoring, recording and communication features T&D

APPLICATION MiCOM P124 overcurrent protection relays provide a complete and fully safe protection for applications where no external auxiliary power supply is available or guaranteed. They provide efficient protection for industrial plants, utilities distribution substations or customers and can be used as either main or backup protection. The following two models are available: > Self-powered P124 > Dual-powered P124 Self-powered P124 model offers a simple and cost efficient solution when no external auxiliary power supply is available. In addition to its protection functions and when powered by an external auxiliary source, dual-powered P124 offers the ability to transmit recorded and measured data to a supervisor via communication networks. Should the auxiliary power supply fail, protection and tripping functions remain fully operational. These two types of MiCOM P124 relays take the power necessary for their operation from line current transformers. The functions offered by these two models are listed below. MAIN FEATURES Both models offer a wide range of overcurrent protection functions without requiring an external auxiliary supply: three independent phase stages, three independent earth stages, twelve groups of IDMT curves for the phase and 14 for the earth, and two thermal overload stages. The dual-powered model offers additional protection, automation and monitoring. Some of these additional functions are operational only when an auxiliary power supply is available. In the event of loss of this power supply, the performances of the P124 dual-powered relay become equivalent to the ones of the selfpowered model. The power supply to the electronic circuits of the MiCOM P124s has been optimised so that it can trigger the circuit-breaker with a load current of 0.2 In on at least one phase. The hardware architecture and software algorithms have been studied to operate on very short failure detection times, so that, starting from a load current of 0.2 In, tripping occurs within no more than 30 ms. 2>3 Function ANSI Codes Self-powered Dual-powered MiCOM MiCOM Three-phase non directional overcurrent 50/51 3 independent thresholds Phase-earth non directional overcurrent 50N/51N 3 independent thresholds Thermal overload (true RMS) 49 2 independent thresholds Undercurrent 37 (note 1) Negative phase sequence overcurrent 46 Broken conductor detection (I2/I1) Blocking logic (note 1) Selective relay scheme logic (note 1) Cold load pickup (note 1) Setting groups 1 2 Assignable inputs/outputs (note 1) Autoreclose option (4 shots) 79 (note 1) Output for striker triggering Changeover contact output for trip coil Bistable magnetic indicator flag for trip indication 4 extra magnetic flags option Output relay latching 86 (note 1) Circuit breaker failure 50 BF Circuit breaker supervision Measurements (true RMS) Peak and rolling values Event records (note 1) Fault records Disturbance records (note 1) Rear port RS485 communications (note 1) Front port RS232 communications (note 1) : Function not available if auxiliary power supply fails.

MiCOM P124 relays are equipped with two types of circuit-breaker trip outputs, fully independent from an external auxiliary power supply: > A capacitance discharge output capable of putting out sufficient power to a striker releasing the actuating mechanism of the circuit-breaker, > A changeover contact relay output capable of sending an order directly to the circuit-breaker coil. The front panel includes an electromagnetic bistable flag to indicate that a trip has occured. As an option in the dual-powered model, four additional magnetic indicator flags are freely configurable. Depending on the model, one or several LEDs indicate the correct operation of the relay as well as other information regarding protection of the electrical system. MiCOM P124 relays are housed in a 4U-30 TE shallow metal case for mounting either in a rack or in a panel. PROTECTION AND CONTROL > Time-delayed phase overcurrent (51) MiCOM P124 relays provide three phase current inputs. Three independent stages are available. For the first stage, the user can select between 12 different types of curves (IEEE/ANSI, IEC, RI, RC). For each curve model a selection of 60 different TMS values are available to optimise fault detection and shorten tripping time in co-ordination with fuses, motors, feeders, transformers and other devices. The second and third stages have independent settings with adjustable definite time tripping. Time delays can be set from 0 to 180s thus providing maximum selectivity. The phase current can be set from 0.1 to 40 times the rated phase current (first threshold limited at 4In). FUNCTIONAL OVERVIEW Front port Setting software S1 Rear port RS485 port To setting software S1 to SCADA system 79 85 AUXILIARY FUNCTIONS - Auxiliary timers - Peak and rolling demand - CB Monitoring - Cold Load Pick Up - Trip Circuit Supervision - Blocking Logic - Selective Scheme Logic - Self Monitoring MEASUREMENTS - Phase Current - Residual current - Frequency - Autoreclose counters - Direct and inverse currents - CB mechanical operation counter - CB electrical operation counter RECORDING FEATURES Fault record 5 Event Recording 75 Dist. Recording 3 Sec 50/51 50N 51N 49 46 46BC 50BF 37 Always Available Available on the Dual Powered model Only P124: Self and Dual Powered Overcurrent Relays (Description of ANSI code nos. see Functions Table) Two Protection Relays to ensure 100% safety

> Instantaneous phase overcurrent (50) For each phase overcurrent stage, the instantaneous information is generated within 30 ms after the threshold has been exceeded, with a load current of 0.2In on at least one phase. This instantaneous information is generated within 60 ms of the circuitbreaker opening (close-on-to-fault case). For the dual-powered model, the user can assign each instantaneous information to output contacts, as well as to four LEDs and four magnetic indicator flags located on the front panel. > Thermal overload (49) Transformers and cables must be protected taking into account their particular thermal characteristics. MiCOM P124 relays include a thermal overload element based on true RMS value of the current. Alarm and overload thresholds as well as thermal time constants are fully programmable to match each device requirement. > Undercurrent (37) MiCOM P124 dual-powered relays provide undercurrent protection. This function is particularly useful to detect a loss of load or a circuit breaker failure. Ith > Negative sequence overcurrent (46) In order to maximise the time of operation of electrical systems, dual-powered MiCOM P124 relays provide a negative sequence overcurrent protection function. This programmable function is particularly well adapted to detect any phase unbalance conditions. Instantaneous and time-delayed (DT or IDMT) negative sequence overcurrent stages are the same stages as the phase overcurrent. Time I < I > t > I >> t >> I >>> t >>> Current Fig. 1 Overcurrent Stages > Time-delayed earth fault (51N) Earth fault detection is identical to the detection of timedelayed phase overcurrent. Three independent earth fault stages can be selected. For the first stage, the user can select either any of the 14 families of curves and TMS values or a definite time setting. Earth current range can be set from 0.002 to 40 times the rated earth current to allow maximum sensitivity for earth fault detection. > Broken conductor A typical unbalanced fault that can occur on the system is an open circuit fault. This fault can arise from broken conductor, mis-operation of one of the switchgear poles, or blowing of a fuse. MiCOM P124 relays incorporate an element, which measures the ratio of negative to positive sequence current (I2/I1). This fully programmable function allows more sensitivity and stability than pure negative measurement. Earth current is generated either by a CT core of sufficient power, or by a residual connection of the three line CTs. > Instantaneous earth fault (50N) As for phase faults, MiCOM P124 relays generate instantaneous data for each earth fault stage, with the same characteristics. Fig. 2 Broken Conductor Detection For the dual-powered model, the user can assign instantaneous earth fault stages to output contacts, as well as to four LEDs and four magnetic indicator flags located on the front panel. 4>5

> Blocking logic When relays are used in critical networks, management of protection relays must take surrounding devices into consideration. In MiCOM P124 dual-powered relays, two blocking logic inputs can be configured independently of each other to lock any selected element (current thresholds, thermal replica, etc.). This function is deactivated in the event of a loss of auxiliary power supply. > Selective relay scheme logic Dual-powered MiCOM P124 relays include selective relay scheme logic. A dedicated digital input can temporarily alter the time delay settings in response to the phase/earth fault start condition of a downstream relay. This function allows the relay to clear the fault faster when used in a cascade scheme. It is an alternative for personnel more familiar with this type of selectivity than with blocking logic. > Inputs and Outputs Dual-powered MiCOM P124 relays have seven output relays with unbiased changeover contacts and five opto-isolated logic inputs. Each input can be configured for the blocking logic, selective logic, etc. and each output can be assigned to trip on thresholds crossing and to light up a LED on the front panel. > Tripping outputs MiCOM P124 relays have two types of tripping outputs that are entirely independent from any auxiliary supply: A capacitance discharge output capable of supplying a striker with an energy of 20mJ at 12 volts. Another changeover contact relay output with a high breaking capacity to trip the circuit-breaker coil. > Cold load pickup The cold load pickup feature allows selected settings to be raised to react to temporary overload conditions that may occur during cold starts. This function is deactivated in the event of loss of auxiliary power. 400 Fig. 4 MiCOM P124 adapted to a striker Current (% of In) 300 200 100 Fig. 3 Nominal Setting 0 1 2 3 4 5 6 Time Cold Load Pickup curve > Optional autorecloser (79) MiCOM P124 dual-powered relays include an optional 4 shot autorecloser. All programmed protection functions may independently start any of the shots and the user can program which functions are allowed to trip after any of the shots. Dead and reclaim times are freely adjustable. Front panel LEDs can be configured to display the status of the autorecloser. > Setting groups External conditions may impose the need of different settings. Dual-powered MiCOM P124 relays provide two setting groups. Switching between setting groups can be done via the activation of a logic input, through the front panel interface, or through remote communication. A counter stores the number of reclose commands. This information can be displayed either locally or remotely. This function can be activated only when auxiliary power supply is present. > Output relay latching (86) This function is available only for dual-powered versions of MiCOM P124 relays. Any outputs, including the trip output, can be latched. Latched outputs can be reset via the activation of a logic input, through the front panel interface or through remote communication. MiCOM P124, the easy, safe and fast way to detect the fault in your power system.

MONITORING FUNCTIONS OFFERED BY THE DUAL-POWERED MODEL > Trip circuit supervision MiCOM P124 relay constantly monitors trip circuit and ensures that they are available. Operation personnel can easily view this information, both locally and remotely, and optimise switchgear maintenance. > Event recording 75 logic events are stored in MiCOM P124 dualpowered model. Events include inputs/outputs, change of status, alarms and contacts operations. All events are time stamped to 1ms, and can be accessed either locally or remotely. > Disturbance recording Up to five records or 3 seconds each can be stored in MiCOM relays. The current sampling frequency is 1600 Hz. The different records can be retrieved either locally or remotely. > Measurements MiCOM P124 relays permanently monitor all current inputs, calculate the frequency and line currents, display values on the LCD and store measurements in memory. The measured values are true RMS up to the 10th harmonic. This data can be accessed either locally or remotely. FAULT RECORDING The last 5 faults are stored inside both models of MiCOM P124 relays. Each fault includes: > Record number > Fault time > Active setting group > Faulted phase > Protection operation > Magnitude of input quantities Fault indicator helps the user to clearly identify the fault and to monitor relay setting and operation. In addition, the dual-powered model offers the following functions: time-tagging of all parameters, status of logic inputs and outputs and remote retrieval of stored information. USER INTERFACE > Front panel and menus The user can program and modify all parameters (protection, communication, automation, LEDs, inputs and outputs) through the front panel user interface. The backlit LCD informs the user about settings, measurements, faults, etc. The menus have a pull-down structure to allow easy and quick access to any data. > Dedicated LEDs An healthy LED on the front panel of MiCOM P124 relays indicates that the relay is correctly energized with sufficient power from line current. In addition, for the dual-powered model, three LEDs indicate the relay condition (Trip, Alarm, Watchdog). > Configurable LEDs (dual-powered model only) To facilitate identification of electrical faults, 4 LEDs are freely programmable. Each LED can be programmed to light up when one or several thresholds are crossed or when a logic input is activated. Fig. 5 Front panel of the MiCOM P124 Enter Key Trip Led Clear Key Read Key Alarm Led Equipment Failure Led Auxiliary Supply Led Programmable Leds Trip Flag Indicator Cursor Keys Programmable Trip Flag Indicators Battery RS232 6>7

> Dedicated magnetic indicator flag The front panel also features a bistable magnetic flag that indicates that the trip order has been issued to operate the circuit breaker. > Configurable magnetic indicator flags (dual-powered model only) In order to display faults even when the auxiliary power is down, four additional bistable magnetic flags exactly replicate the status of the four programmable LEDs. > RS485 communications The dual-powered MiCOM P124 includes an RS485 communication rear port. This port is available for MODBUS TM, Courier, DNP3.0 or IEC 60870-5-103 protocols. MiCOM relays can transmit to the monitoring or SCADA system, settings, measurements, alarms, faults, events and disturbance records. The communication parameters (relay address, data rate, parity, etc.) can be programmed using the operator interface front port. A communication failure does not affect the protection functions of MiCOM relays. > Communication RS232 The front serial RS232 communication port has been designed to be used with MiCOM S1 Software, which provides the ability to program settings off-line, extract and view event, disturbance and fault records, view the measurement information dynamically and perform control functions. > K1-3 Striker Associated with a self-powered relay, such as MiCOM P124, the K1-3 Striker converts an electrical pulse of low intensity (<20mA during 25ms) into a mechanical pulse of 4,7 dan, thus allowing the trip of the circuit breaker. > Capacitor Trip Unit MiCOM E124 For applications where there is no auxiliary supply or where a striker can not be used, MiCOM E124 ensures the supply of energy to a self or dual powered relay, such as MiCOM P124. This capacitor module has such storage capacity that, in case of loss of auxiliary supply, it can supply sufficient energy to excite a standard trip coil for two consecutive tripping orders without recharge. Fig. 7 MiCOM E124 Capacitor Trip Unit ACCESSORIES > Battery box Even when the circuit-breaker is open, i.e. the relay is no longer energized by the load current, settings can be applied thanks to a simple and inexpensive battery box. On one side, this battery box is connected to the RS232 port of the relay and on the other side to the PC loaded with the support software MiCOM S1. This battery box temporary energizes the relay and so allows the user to quickly and easily retrieve or change the setting of the relay. Fig. 6 MiCOM E1 battery box HARDWARE > Case The relays have a drawout metal 4U shallow case. All CT inputs are short-circuited if the active unit is withdrawn from its case. All MiCOM relays can be mounted in a panel or in a rack. They require no handling operations, since all the settings are put in through the operator interface. > Wiring External connections are made via MIDOS type terminal blocks. Each connection includes 2 x 6.35mm Faston and one M4 screw fixing. The wiring of both models of MiCOM P124 is standard to provide maximum compatibility.

DEVICE TRACK RECORD >> MiCOM Px2x range: Over 100.000 Medium Voltage Protection Relays sold in only 6 years of existence >> MiCOM P124: First released in September 2000. Over 6150 devices installed. AUTOMATION-L3-P124-BR-01.05-0819-GB - - AREVA - 2005. AREVA, the AREVA logo and any alternative version thereof are trademarks and service marks of AREVA. MiCOM is a registered trademark of AREVA. All trade names or trademarks mentioned herein whether registered or not, are the property of their owners. - 389191982 RCS PARIS - Printed in France - SONOVISION-ITEP AREVA T&D Worldwide Contact Centre: http://www.areva-td.com/contactcentre/ Tel.: +44 (0) 1785 250 070 www.areva-td.com Our policy is one of continuous development. Accordingly the design of our products may change at any time. Whilst every effort is made to produce up to date literature, this brochure should only be regarded as a guide and is intended for information purposes only. Its contents do not constitute an offer for sale or advise on the application of any product referred to in it. We cannot be held responsible for any reliance on any decisions taken on its contents without specific advice.