ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

Similar documents
ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

OSM PRODUCT GUIDE. OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

Reclosers. Functional Specification Guide PS280026EN. Form 6 Rack/Yard-Mount Recloser Control

Products Portfolio. Pole mounted Vacuum Recloser

Functional specification for Form 6 pole-mount recloser control

NU-LEC. Loop Automation. Reclosers & Sectionalizers

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Form 6 Pole Mount Microprocessor-Based Recloser Control Technical Specifications

Vacuum-Break Switches

Elastimold Molded Vacuum Recloser - MVR

NPW800R RETROFITTING. Power and Volatge Protection Relay

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch

2.1 The NOVA-TS Triple-Single Recloser and Form 6-TS control shall be designed in accordance with the following standards as applicable:

Medium Voltage Distribution. U-Series Three-Phase Recloser/ W-Series Single-Phase Recloser with ADVC Controller

OSM PRODUCT GUIDE. OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models

GMK GROUND MOUNT KIOSK PRODUCT GUIDE

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

MW/MVAR Transducer Specifications

POLE MOUNTED Load Break Switch

InteliPro. Protection Relay for Parallel Applications. Technical Specification

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Siemens Vacuum Recloser 3AD. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

GE Multilin 350 Feeder Protection Relay Specifications

SM100. On-Line Switchgear Condition Monitoring

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Feeder protection relay SPAA 121 C. Product Guide

MINER-S Station Controller

S&C 6801M Automatic Switch Operator

VisoVac padmount fault interrupter

DIAC/DIFC/DSFC. Single Phase Digital O/C. Single phase or ground overcurrent protection for industrial and utility power systems.

MEDIUM VOLTAGE RING MAIN UNIT

SECTION SWITCHBOARDS

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

DNP Points List and Implementation

Protection Relays PHASE & RESIDUAL OVERCURRENT

Autodaptive Capacitor Control M 2501B

Bus Bar Protection Relay B-PRO 4000

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

Solid Dielectric Switchgear

www. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Earth-fault Relay SPAJ 110 C. Product Guide

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

SF6 GAS INSULATED PAD MOUNTED. Load Break Switch. SSPGS SERIES 15kV, 25.8kV 400A, 600A

Solid Dielectric Switchgear Catalog S-trid13

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

DIGITAL TEMPERATURE MONITOR MASTERTEMP ANSI I CATALOG

Scout-S Station Controller

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

Type VRLTC tap changer

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

Microprocessor protection and automation devices

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Diamondback. Solid Dielectric Load Break Switch Catalog. Distributed By;

Siemens Fusesaver and Remote Control Unit 3AD8

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

MPSC Microprocessor-based protection and metering devices for low voltage power circuit breakers. ABB Power Distribution

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

VIP 40/45 VIP 400/410

MiCOM P111. Three phase and earth fault overcurrent relays

g Energy Multilin Recloser Controller DGCR Communications Protection Automation & Control Security & EnerVista Software Hardware Metering & Monitoring

INTEGRATION OF RECLOSERS INTO SCADA SYSTEMS

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

GRE130. Protection and Control for MV Systems

SERIES SD3800 / SD3810 SPECIFICATION

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

OSM PRODUCT GUIDE OSM AUTOMATIC CIRCUIT RECLOSER SINGLE TRIPLE MODEL

g Energy Multilin Voltage Regulator Controller DGCV KEy BENEFITS APPLICATIONS FEATURES Metering & Monitoring Voltage Regulation Communications

E4PA. Ultrasonic Displacement Sensor. Ordering Information

SACE Emax 2 Specification guide

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

DNP Points List and Implementation for Universal Controls

Descriptive bulletin. OVR outdoor vacuum reclosers kv Innovative designs ensure system reliability

SIEMENS 8DJH 11/22 kv Ring Main Units

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES

Communication Gateway COM 610. Product Guide

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers

GE Power Management. MMII Intelligent MCC Controller

e 2 TANGO -400 Overcurrent Relay K Catalogue EN

Transcription:

ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Ver. 081226

General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated with cycloaliphatic epoxy materials. The Solid Insulated Vacuum Recloser is designed for the inherently reliable, intelligent automation and environmentally friendly, completely oil free and gas free. The mechanism is enclosed in a powder coated stainless steel and cycloaliphatic epoxy resin bushing is bolted on to the stainless steel enclosure. The cycloaliphatic epoxy advantages show permanent flexibility, superior surface arc tracking resistance, hydrophobicity preventing continuous water film from forming leakage current paths, ultraviolet resistance and high tensile strength. The control cubicle is heat insulated with polyurethane to minimize temperature variation and protected from solar heating as adopting sunshine cover to the outside and heat insulation inside of control cubicle. The operation of recloser uses a low- voltage power source supplying from low voltage distribution line by utility or potential transformer and a fully charged battery and trip and close capacitors provide recloser operation over hundreds of open-close operations as back-up upon loss of control power. This allows recloser operation independent of the high voltage supply, the low voltage supply and the battery and capacitor conditions with dead line operation capability required for SCADA and distribution automation. 983 Vents of the control cubicle are screened against vermin s entry and door is sealed with a rubber gasket. Especially all electronic parts built in microprocessor control are fully protected from entry of moisture and condensation able to use any places where tropical, moderate and severe humidity area is located on. The mechanism is operated by a magnetic actuator which the opening and closing solenoid is respectively equipped with. As the actuator uses magnetic latching, the mechanical parts are drastically reduced, resulting from high reliability and maintenance free operation during the life time. 273 Side mounting Mid-point mounting 273 983

A current transformer and a capacitive voltage transformer are moulded in the horizontally arranged epoxy bushing. These sensors provide to incorporate the functions of an overcurrent protection relay, a ground fault relay, a sensitive earth fault relay and to measure line current, voltage, real and reactive power, power factor, demand watts and VARs, frequency and so on. All the measured values and event records are stored in the microprocessor control for transmission or off-line analysis. The recloser functions, settings and data records are programmable and readable with PC or remote communi cation. Personal computer based on software package supports on-line and off-line programming, monitoring, measuring and control of recloser via RS232 port. All telemetry communication can be supported with DNP3.0 protocols based on IEC870-5 and Modbus. The advantages of cycloaliphatic epoxy encapsulation - environmentally friendly, oil free and gas free - Proven performance in outdoor use - Compact, light weight, easy to trans portation - Superior surface arc tracking resis tance - Excellent hydrophobicity - Highly resistant to moisture absorption - Ultraviolet resistance - Outstanding tensile characteristics The advantages of magnetic actuator - Elimination of mechanical latches and associated associated linkage provide reliable, trouble free operation - Dramatic reduction in moving parts provide maintenance free, ten thousand operations without periodic maintenance. - Compact, light weight and minimum mounting space - High response time in instantaneous reclose - Reduced installation and operating cost. User Interface Panel

Microprocessor Based Recloser Control EVRC2A Features Reduced distribution automation costs RTU and control mounted in one control cubicle with space for radio and modem DNP 3.0, Modbus communication protocols and SCADA capability 12Vdc ~ 24Vdc auxiliary power available for modem or radio Voltage, current and power metering Record of operation, fault and waveform data for line and load profile data Un-interruptable power supply with trip and close Inner heat insulation for polyurethane foaming Microsoft Windows-based EVRC2A interface software Average load profile & waveform EVRC2A cubicle Protections User TCC construction capability Three curve standards: IEEE, IEC and 37nonstandard inverse time curves Protective settings in nonvolatile memory during power failure Delay time overcurrent protection(51p, 51G) Instantaneous overcurrent protection(50p, 50G) Negative sequence overcurrent protection(46) SEF protection Source and load side synchronism check Cold load pickup and sequence coordination Underfrequency and load shedding(81) Undervoltage, overvoltage detection and alarm(27,59) Directional controls(67) Fault events & 15 Cycles waveform Editor for TCC modification

Mutli-metering - Current - Voltage - Measures KW and KWH, power factor, demand watts and VARs and frequency - Load profile data & oscillogram Remote Communication - RS-232 ports - DNP3.0 protocol based on IEC870-5, Modbus - Built in RTU - Complete remotely access for recloser functions, settings metering and data records Technical EVRC2A Control Specifications RATINGS Rated frequency 50 or 60 Hz Control voltage 110/220 AC ENVIRONMENTAL Ambient temperature range Storage -40 to +85 Operation -25 to +70 Degree of protection IP65 Insulation test voltage 2kV 50/60Hz, One minute Impulse voltage withstand 6kV Peak, 1.2/50 ANSI C62.45, IEC 61000-4-5 Interference test withstand SWC ANSI C37.90.1, IEC 61000-4-4 Radio frequency interference IEC 255-22-3 Class, ANSI C37.90.2 GENERAL PROTECTION (CT ratio 1000:1A) Phase time overcurrent CT ratio(0.04~3.20), (40~3200A at CT 1000:1) Phase instantaneous multiplier range CT ratio(1.00~20.00) Ground time overcurrent CT ratio(0.02~1.60), (20~1600A at CT 1000:1) Ground instantaneous multiplier range CT ratio(1.00~20.00) Sensitive earth fault CT ratio(0.005~0.160),(5~160a at CT 1000:1) Phase and ground time curves IEEEC37.112, IEC255-3, User programmable curves 37 non standard inverse time curves RECLOSE Reclose times Programmable from 1 to 4 Reclosing(Dead) times 1st reclose: 0.5-600 sec in 0.01sec steps 2nd reclose:1.0-600 sec in 0.01sec steps 3rd reclose: 1.0-600 sec in 0.01sec steps 4th reclose: 1.0-600 sec in 0.01sec steps Reset (Reclaim) times 1-600 sec in 1sec steps METERING (At rated voltage and current) Current 1% Voltage % (2.5% : CVD) Watt hours 3% (5% : CVD) Vars hours 3% (5% : CVD) Demands 3% (5% : CVD) Power factor 0.02 (0.05 : CVD) Frequency 0.02Hz (0.05Hz : CVD) RECORDING Waveform capture : 16 events with 15 cycle System event : Last 500 events Diagnostic event : Last 100 events Load profile : Last 1024 events, 42 days/ 60Min.(5,10,15,20,30,60, min interval) Counter : Trip, fault, system restart Recloser wear : phase A,B,C

HV terminal Vacuum interrupter Integrated sensors Solid insulation housing water proof cabinet Open/Close indicator Manual trip and locking lever Manual closing shaft Magnetic actuator 78-2 BUNCHEON-RI BONGDAM-EUP HWASEONG-CITY GYUNGGI-DO KOREA TEL: +82-31-227-1161 FAX : +82-31-227-1164 http://www.entecene.co.kr E-mail : entec@entecene.co.kr