Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

Copyright: December 2017 Nidec Issue: E

PROFINET MODULE. Communications module. User Guide. This manual is to be given to the end user en / a. Power. Error. Status.

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

ETHERNET/IP & PROFINET MODULE

Profinet Module. User Manual. Contents

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

OPERATING INSTRUCTIONS MCD

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3.

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Install the DeviceNet Module using the following procedure:

Ethernet/IP Module. User Manual. Contents

Instructions. Modbus RTU Card (WSIQ-COM-MB)

1. Installation DEVICENET INTERFACE. Install the DeviceNet Interface using the following procedure:

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Copyright December 2017 Nidec Issue: D

1. Introduction. 2. Installation MODBUS INTERFACE

Installation Guide EtherNet/IP Module

Installation Guide PROFINET Module

Installation Guide Modbus TCP Module

ASTAT XB/XBm Remote Operator

Installation Guide EtherNet/IP Module

MCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment.

VersaMax IP Input Module

Opal Pro to DeviceNet. Opal Pro MS6 SERIES. DeviceNet Interface Users Manual. Revision Page 1

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

Serial PROFIBUS Interface

Opal Pro AB Ethernet IP. Opal Pro MS6 SERIES. AB Ethernet IP Interface Users Manual. Revision Page 1

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Operation manual. HDOM-Profibus-V0. More options please visit;

Optidrive Applications Support Library

User Guide SE73-PROFIBUS-DP. Commander SE. Part Number: Issue Number: 4.

Advanced User Guide SE73-PROFIBUS-DP. Commander SE. Part Number: Issue Number: 4.

Gateway 1400 Reference Manual

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

EL731 PROFIBUS INTERFACE

Section 0.0 Warnings... 2 Section 1.0 Quick Set-up... 3 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

Section 0.0 Warnings... 3 Section 1.0 Quick Set-up... 4 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

Section 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents

PAC BI-DP BIM and 8701-CA-BI Carrier

Section 1 Caution Statements... 3 Section 2 Introduction Section 3 Basic Setup Procedure... 5 Section 4 Installation... 6

Optidrive Applications Support Library

1. Introduction. 2. Installation INSTALLATION INSTRUCTIONS: MCD USB MODULE

DVPPF02-SL PROFIBUS DP Slave Communication Module

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Operator Manual for Profibus

POWERDRIVE UNIDRIVE SP VARMECA 33/34 PROXIDRIVE DIGIDRIVE IVE SK

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

Profibus DP Expansion Board

User Guide. Cloning interface small option module for Unidrive and Commander GP. Part Number: Issue Number: 3

- 15G0078B130 - USB MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

PROFIBUS Gateway for MCD 3000 Series Soft Starters. User Manual

PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

SMART RELAY SRW 01 V4.0X

Advanced User Guide. SE77-DeviceNet. Commander SE. Part Number: Issue Number: 1.

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

MGate 5111 Quick Installation Guide

SK TU4-PBR Part number:

User Guide Regenerative & Non-Regenerative Digital DC Drives 5 to 1000 HP

SSW06. Soft Starters.

SK CU4-PBR-C Part number:

E2 Modbus RTU Register Map

MPCR Series Profibus-DP Technical Manual

SM-I/O Plus. Solutions module for UNIDRIVE SP. User guide. This manual is to be given to the end user. Réf en / a

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

USERS IMS2 SERIES SOFT STARTERS

Installation and Setup

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

CONTENTS IMS2 SERIES A. 2.1 Overview Feature List Part Number Format... 3

PACSystems* RX3i IC695PBM300

User s Manual Pulse Encoder Interface Module OTAC-01

Digistart. Soft starters for 3 phase induction motors 7.5 to 800kW (18 to 1600A) 200V, 400V, 575V, 690V

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

TeSys U Communication Variables

User Guide SM-I/O PELV. Solutions Module for: Unidrive SP Commander SK. Part Number: Issue: 3.

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

Installation, Operation and Maintenance Manual

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE

Softstarters. Type PSTX Fieldbus communication, Anybus Modbus TCP. 1SFC132087M0201 March SFC132087M0201 1

PROFIBUS MODULE (CB15) English Operating Instructions. Contents. Warning and Caution Notes

PROFIBUS Interface WM : PD

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

mbc082 Bus Converter

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Profibus DPV0/DPV1. 1SFC132091M0201 June SFC132091M0201 1

CONTENTS. Basic Setup Procedure Section 1 Caution Statements Programming and Operation IMS2 SERIES H

Softstarters Type PSTX Fieldbus communication, Anybus CompactCom DeviceNet

1 Extended and Advanced Cascade Controller Option 3

Softstarters. Type PSTX Fieldbus communication, Anybus EtherNet/IP

Powered Roller Controller for DeviceNet

Transcription:

General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment or from mismatching the starter with the motor. The contents of this guide are believed to be correct at the time of printing. In the interests of commitment to a policy of continuous development and improvement, the manufacturer reserves the right to change the specification of the product or its performance, or the content of the guide without notice. All rights reserved. No parts of this guide may be reproduced or transmitted in any form or by any means, electrical or mechanical including, photocopying, recording or by an information storage or retrieval system, without permission in writing from the publisher. Copyright: December 2017 Nidec

Contents 1. Introduction... 4 2. Important User Information... 4 3. Installation... 4 3.1 Installation Procedure... 4 3.2 Physical installation... 4 4. Profibus Module Connection and Configuration... 6 4.1 Adjustment... 6 4.2 Connection... 6 4.3 LEDs... 7 5. Master Configuration... 7 5.1 Configuration... 7 5.2 Operating modules... 7 6. Data Structures... 8 6.1 Soft Starter Control I/O Data Structure... 8 6.2 Soft Starter Monitoring I/O Data Structure... 9 6.3 Soft Starter Programming I/O Data Structure... 12 7. Profibus Diagnostics and Modes... 13 7.1 Profibus Diagnostic Telegram and Flag... 13 7.2 Profibus Freeze Mode... 13 7.3 Profibus Sync Mode... 13 7.4 Profibus Clear Mode... 13 8. Specifications... 14 Profibus Module: User Guide 3

1. Introduction The Profibus Module can be used with Digistart D2 and Digistart D3 soft starters to allow the starter to be connected to a serial communications network using the Profibus protocol. 2. Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. 3. Installation CAUTION Remove mains and control voltage from the soft starter before attaching or removing accessories. Failure to do so may damage the equipment. 3.1 Installation Procedure 1. Remove control power and mains supply from the soft starter. 2. Attach the module to the soft starter as illustrated. 3. Set the module address to match the address set in the Master configuration tool. 4. Apply control power to the soft starter. 5. Insert the network connector and power up the module. 3.2 Physical installation 1. Fully pull out the top and bottom retaining clips on the module. 2. Line up the module with the comms port slot. 3. Push in the top and bottom retaining clips to secure the module to the starter. Figure 3-1 Attach the module to the starter A B C 10178.C 4 Profibus Module: User Guide

Figure 3-2 Remove the module from the starter Remove the module using the following procedure: 1. Take the module off-line. 2. Remove control power and mains supply from the soft starter. 3. Disconnect all external wiring from the module. 4. Fully pull out the top and bottom retaining clips on the module. 5. Pull the module away from the soft starter. A 03550.C Profibus Module: User Guide 5

4. Profibus Module Connection and Configuration 4.1 Adjustment Figure 4-1 Adjustment switches Before powering up the Profibus Module, set the two rotary switches so that the module address matches the address set in your Master configuration tool. eg MSD = 2 and LSD = 1 corresponds to address 21. (The diagram shows the factory default setting for the rotary switches). The module automatically detects the network data rate. MSD ADDRESS LSD 4.2 Connection The module connects to the Profibus network via a standard DB9 connector. The Profibus Module can be powered either through the network cable or externally (24 Vdc). Figure 4-2 Profibus Module connections Digistart D2 1 Digistart D3 1 2 2 3 4 08651.A 3 4 08652.A Digistart D2 CSL, DI2: Stop input Profibus Module External 24 Vdc supply required if not powered through bus DB9 connector to Profibus network Digistart D3 (Remote mode) DI2, +24V: Stop input DI3, +24V: Reset input Profibus Module External 24 Vdc supply required if not powered through bus DB9 connector to Profibus network Digistart D2: For the Profibus Module to accept serial commands, a link must be fitted across terminals CSL-DI2 on the soft starter. Digistart D3: Input links are required across the stop and reset inputs if the soft starter is being operated in Remote mode. In Local mode, links are not required. If the Starter Disable function is not required, change the setting of Pr 3A or connect a link across DI4, +24V. NOTE Digistart D3: Control via the serial communication network is always enabled in local control mode, and can be enabled or disabled in remote control mode (Pr 3O Comms in Remote). See the soft starter user manual for parameter details. 6 Profibus Module: User Guide

Pin No. 1 Shield 2 24 Vdc negative (optional) 3 RxD/TxD-P 4 Not used 5 DGND 6 VP (end of bus slave only) 7 24 Vdc positive (optional) 8 RxD/TxD/-N 9 DGND 4.3 LEDs Figure 4-3 Feedback LEDs DB9 connector Assignment 1 2 OFF ON Power status (red) Module not powered up Module powered up and ready to go online Bus status (green) No connection, offline or data exchange failure Module online and in data exchange state 03523.C NOTE If communication fails between the module and the network, the Bus Status LED will go off. When communication is restored, the Bus Status LED will come back on. NOTE When a communications failure occurs, the soft starter may trip if the Communication Timeout parameter for the network is set greater than zero. When communication is restored, the soft starter must be reset. 5. Master Configuration 5.1 Configuration Import the latest.gsd file into your Master configuration tool. This file is available from. If your Master uses on-screen icons, two graphic bitmap files are available from the website. SSPM_N.bmp indicates normal mode. SSPM_D.bmp indicates diagnostic mode. NOTE The Profibus Module has a slave address range of 0 to 99. If the Profibus network fails, the module will leave data exchange mode after the network watchdog timeout period has expired. This timeout period is set at the Master configuration tool. A Communication Timeout parameter in the GSD file sets how soon after this event the soft starter will be forced into a trip state. The user can adjust the Communication Timeout parameter in the GSD file to any setting between 0 and 100 seconds. The default setting is 10 seconds. NOTE If the Communication Timeout parameter is set to 0, the current state of the soft starter will remain unchanged on a network failure. This gives the user the option of operating the soft starter via local control, but is NOT failsafe. 5.2 Operating modules The GSD file contains three operating modules, supporting data I/O structures as follows: Table 5-1 Data structures Data Structure Basic Module Extended Module Parameter Upload/ Download Module Soft Starter Control I/O Data Structure on page 8 Soft Starter Monitoring I/O Data Structure on page 9 Soft Starter Programming I/O Data Structure on page 12 The Basic Module allows the user to start and stop the soft starter and read limited information on operating status. The Extended Module defines additional bytes allowing the user to read soft starter operating data such as actual motor current and motor temperature. The Parameter Upload/Download Module allows the user to read and write soft starter parameter values (only applicable to Digistart D3 soft starters). Profibus Module: User Guide 7

6. Data Structures 6.1 Soft Starter Control I/O Data Structure Master > Slave control word is structured as follows: Table 6-1 Control I/O data structure Byte 0 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserved Reserved Reserved Quick stop Motor set Reserved Reserved Byte 1 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserved Reserved Reserved Reserved Reset Reserved Reserved Fwd run Quick Stop Bit When Fwd run bit changes from 1 to 0: 0 = stop action will be a soft stop (as selected on the soft starter). 1 = stop action will be a quick stop (ie coast to stop). NOTE The Quick stop bit must be set to 0 before the soft starter can perform a start. Motor Set Bits (Digistart D3 only) Selects which parameter set to use when starting: 0 = selected from soft starter remote input (programmable input must be set to 'Motor Set Select') 1 = soft starter primary motor set (ensure soft starter programmable input is not set to 'Motor Set Select') 2 = soft starter secondary motor set (ensure soft starter programmable input is not set to 'Motor Set Select') 3 = Reserved NOTE If Pr 3A Input A Function for Digistart D3 is set to motor set select, this will cause a conflict with motor set selection via serial communications. Slave > Master status word is structured as follows: Table 6-2 Status word structure Byte 0 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Ramping Local 2 Motor current (% FLC) 1 Byte 1 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserved Reserved Reserved Reserved Warning 2 Fault On Ready 1 Motor current (% FLC) represents current as a percentage of the set motor full load current. A maximum value of 63 represents 200% full load current. To convert this value to a readable percentage, divide by 0.315. For models D3-0053B and smaller this value will be 10 times greater than the value displayed on the keypad. 2 Only available on Digistart D3 soft starters. Ready is set when the soft starter is ready to start the motor. On is set when the soft starter is starting, running or soft stopping the motor. Warning is set when the soft starter detects a warning condition. Fault is set when the soft starter has tripped. Ramping is set when the soft starter is starting or soft stopping the motor. Local is set when the soft starter is set to Local mode. 8 Profibus Module: User Guide

6.2 Soft Starter Monitoring I/O Data Structure Master > Slave output byte is structured as follows: Table 6-3 Monitoring I/O data structure Operating data request (Data request numbers 1 to 16) Byte 2 Slave > Master input bytes, in response to an operating data request, are structured as follows: Byte 2 Echo data request number Byte 3 Bits 7 to 1 Reserved Bit 0 = 1: Invalid data request number Byte 4 Data value - high byte Byte 5 Data value - low byte NOTE An invalid data request number will result in the invalid data request number bit being set = 1. NOTE Data request numbers 4 (only Motor 2 Temperature ) to 16 are only valid for Digistart D3 starters. Digistart D2 starters will return zero values. Data values are defined as follows: Table 6-4 Data values Data Request Number Data Value High Byte Data Value Low Byte 0 Reserved 1 Soft starter product type code 1 Soft starter software version number 2 Trip/Warning code Soft starter status 3 2 Average current (high byte) Average current (low byte) 4 3 Motor 2 temperature Motor 1 temperature 5 Reserved % Power factor 6 Power (kw) 7 Power (kva) 8 Average voltage 9 2 L1 current 10 2 L2 current 11 2 L3 current 12 Reserved 13 Reserved 14 Reserved 15 Software major version number Software minor revision number 16 Reserved Digital Input state 1 Product type code: 4 = Digistart D2 8 = Digistart D3 2 For models D3-1x-0053-B and smaller this value will be 10 times greater than the value displayed on the keypad. 3 Motor temperature is calculated using the soft starter thermal modelling. 6.2.1 Power Input bytes for data request numbers 6 and 7 are defined as follows: Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 High Byte Power scale factor Power high nibble Low Byte Power low byte Powerscale functions as follows: 0 = multiply Power by 10 to get W 1 = multiply Power by 100 to get W 2 = Power is represented in kw 3 = multiply Power by 10 to get kw Profibus Module: User Guide 9

6.2.2 Soft Starter Status The low byte data value of data request number 2 reports soft starter status. Bits 0 to 3 function as follows: Table 6-5 Status byte Value (decimal) Bits 0 to 3 Soft Starter Status 0 Unknown (communication error between module and soft starter) 1 Ready to start (waiting) 2 Starting (soft starting) 3 Running (running full voltage at the motor) 4 Stopping (soft stopping) 5 Not ready (restart delay, restart temperature check, run simulation, input A (DI4, +24V) not shorted) 6 Fault (tripped) 7 1 Menu or Logs Menu open (cannot start) 8 1 Jog Forward (slow speed) 9 1 Jog Reverse (slow speed) 1 Only available on Digistart D3 soft starters. Bits 4 to 7 function as follows: Bit Number Function Bit 4 Set if positive phase sequence detected (Bit 6 must = 1) Bit 5 Set if average current exceeds Motor FLC setting Bit 6 Set after first start once phase sequence has been confirmed Bit 7 Set if a communication failure occurs between module and soft starter 6.2.3 Digital Input State The low byte of data request number 16 reports digital input state as follows (0 = open, 1 = closed): Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Low Byte Reserved Input D Input C Input B Input A Reset Stop Start 10 Profibus Module: User Guide

6.2.4 Trip Codes Table 6-6 Trip messages Trip Code Description Digistart D2 Digistart D3 1 Excess start time 2 Motor overload (thermal model) 3 Motor thermistor 4 Current imbalance 5 Frequency (Mains supply) 6 Phase sequence 7 Instantaneous overcurrent 8 Power loss / Power circuit 10 Heatsink overtemperature 11 Motor Connection Tx 12 Input trip 13 FLC too high (FLC out of range) 14 Unsupported option (function not available in inside delta) 15 Starter communication (between module and soft starter) 16 Network communication (between module and network) 17 Internal fault x (where x is the fault code detailed in the table below) 20 1 Ground fault 23 Parameter out of Range 24 Input B trip 26 L1 phase loss 27 L2 phase loss 28 L3 phase loss 29 L1-T1 shorted 30 L2-T2 shorted 31 L3-T3 shorted 32 Motor 2 overload (thermal model) 33 2 Time-overcurrent (Bypass overload) 35 Battery/clock 36 Thermistor circuit 37 RTD/PT100 A 38 1 RTD/PT100 B 39 1 RTD/PT100 C 40 1 RTD/PT100 D 41 1 RTD/PT100 E 42 1 RTD/PT100 F 43 1 RTD/PT100 G 45 RTD/PT100 X Circt 46 Analog input trip 47 Overpower 48 Underpower 255 No trip 1 Available with Digistart D3 only if the appropriate option card is fitted. 2 For Digistart D3, time-overcurrent protection is only available on internally bypassed models. Profibus Module: User Guide 11

6.2.5 Internal Fault x The table below details the internal fault code associated with trip code 17. Table 6-7 Internal fault X Internal fault 70 to 72 Current Read Err Lx 73 ATTENTION! Remove Mains Volts 74 to 76 Motor Connection Tx 77 to 79 Firing Fail Px 80 to 82 VZC Fail Px 83 Low Control Volts 84 to 98 Internal fault X Contact your local supplier with the fault code (X). Message displayed on the keypad 6.3 Soft Starter Programming I/O Data Structure The Soft Starter Programming I/O Data Structure allows the user to upload (read) and download (write) soft starter values over the network. Master > Slave output bytes are structured as follows. Table 6-8 Programming output byte structure Byte 3 Byte 4 Byte 5 Byte 6 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Parameter number to read/write Write Read Reserved Reserved Reserved Reserved Reserved parameter parameter High byte parameter value to write to soft starter/ zero data values for read Low byte parameter value to write to soft starter/ zero data values for read Reserved Slave > Master input bytes are structured as follows. Table 6-9 Programming input byte structure Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 6 Byte 7 Byte 8 Byte 9 Echo parameter number Reserved Reserved Reserved Parameter access level Parameter access level is defined as follows: 0 = Read only 1 = Operator (Digistart D3 parameter groups 1 to 14) 2 = Supervisor (Digistart D3 parameter groups 15 and 16) Write access denied High byte parameter value read from soft starter Low byte parameter value read from soft starter Invalid parameter value Invalid parameter number NOTE This operating module only functions with Digistart D3 soft starters. 12 Profibus Module: User Guide

7. Profibus Diagnostics and Modes 7.1 Profibus Diagnostic Telegram and Flag The Profibus Module supports external diagnostics. The following telegram will be sent to the Master if the soft starter trips or if a parameter is changed at the soft starter. Table 7-1 Profibus diagnostic telegram structure Diagnostic Telegram Data Structure Byte 0 User diagnostic length (Always set = 3) Byte 1 Trip code Byte 2 Changed parameter number (Digistart D3 only) 7.1.1 Profibus Trip Code When the soft starter trips, a diagnostic flag is set at the Master and the trip code is reported in Byte 1. When the soft starter is reset, the diagnostic flag and trip code data are reset = 0, provided the trip condition does not still exist (see Trip Codes). 7.1.2 Changed Parameter Number If a parameter is changed via the keypad, the affected parameter number is reported in Byte 2. When the Master reads or writes the changed parameter, Byte 2 is reset = 0. A changed parameter number does not set a diagnostic flag. 7.2 Profibus Freeze Mode The Profibus Module supports Freeze Mode. In Freeze Mode, inputs are only updated with new data from the soft starter when another Freeze action is carried out. An Un-Freeze action returns the Profibus Module to normal operation. 7.3 Profibus Sync Mode The Profibus Module supports Sync Mode. In Sync Mode, commands to the soft starter are not processed until another Sync action is carried out. An Un-Sync action returns the Profibus Module to normal operation. 7.4 Profibus Clear Mode If the Master sends a global Clear command, the Profibus Module will send a Quick Stop command to the soft starter. Profibus Module: User Guide 13

8. Specifications Enclosure Dimensions... 40 mm (W) x 166 mm (H) x 90 mm (D) Weight... 250 g Protection... IP20 Mounting Spring-action plastic mounting clips (x 2) Connections Soft starter... 6-way pin assembly Contacts... Gold flash Network... DB9 female External power supply... 2-way removable screw type Maximum cable size... 2.5 mm 2 Settings Network address Setting... MSD and LSD rotary switches Range... 0 to 99 Data rate Setting... Auto-detect Range... 9.6 kb/s to 12.0 Mb/s Power Consumption (steady state, maximum)... 35 ma at 24 Vdc Reverse polarity protected Galvanically isolated Certification CE... EN 60947-4-2 14 Profibus Module: User Guide

Profibus Module: User Guide 15