Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4

Similar documents
US 5,634,357 D 385,7683 Bulletin: A21S4

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Heavy Duty Disconnects US 5,634,357 D 385,7683 BULLETIN: A28S4

US 5,634,357 D 385,7683 Bulletin: A28S4

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects

Free-Stand Disconnects and Accessories

Standard Product One-Door Enclosures. Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

See also Accessories. Industrial Corrosion Inhibitors Floor Stand Kit PANELITE Enclosure Lights Overview Bulletin: A28X1, A28X2, A28XM.

UL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12

SEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

Fiberglass. Spec L. Non-Metallic. Hinge-Cover with 3-Point Latch or Quick-Release Latches, Type 4X

Type 4 Disconnect Enclosures

CONCEPT Stainless Steel Wall-Mount Enclosures

Type 4X S.S. Disconnect Enclosures

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

Arc Flash Safety Systems INDEX. Safety Systems. Arc Flash AF-8

Free-Standing Type 12 Enclosures

151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

INTERSAFE Data Interface Ports are mounted on an enclosure to allow programming access to devices inside without opening the enclosure door.

Disconnect Enclosures

INTERSAFE DATA INTERFACE PORTS, TYPE 4/4X/12

Polycarbonate and ABS QLINE E

TYPE 4/12 PREMIER SERIES

Standard Product Left-Hinged

Standard Product Left-Hinged

Polycarbonate and ABS QLINE E

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet

Polycarbonate and ABS QLINE D

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

Technical Operating Information AC Unit (T150116G100) Replacement Filter No Wall-Mount Cabinets

Polycarbonate and ABS QLINE D

Standard Product. Catalog Number. Width. Depth. mm 18 = = = = = = = = 400

Technical Operating Information AC Unit (T150116G100) Replacement Filter No

NEMA Enclosure Solutions for Cisco WLAN Deployments

CHAPTER 3. Intro Page POLYPRO ULTRX QLINE D

FS66S Global Free-Stand Single and Dual Access, Type 4X

FTTX Fiber Optic Cabinet Packages Priority Electronics USA

INDUSTRIAL MODULAR ENCLOSURES EQUIPMENT PROTECTION

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

Shelves, Keyboard Trays and Gland Plates Folding Shelves

Industrial Modular Enclosures

Jockey Pump Controllers

Jockey Pump Controllers

1510 MOTOR CONTROLLERS

Disconnect Enclosures

Ex-CELL Stainless Steel and Painted Steel Enclosures

PROLINE ExtERNaL COmPONENts 0-mm solid BasE Catalog Number Fits Frame B x C W (mm) W (in.) D (mm) D (in.) PB045 PB046 PB064 PB064HF2 PB065HF2 PB066

3630P Encl 34X28 Enclosure Panel. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions

194E FA 32 E P11 P11 6

Product Description. Construction. Finish. Industry Standards

Top Door Opening, Height mm/in

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

194E FA 32 E P11 P11 6

Featured Products - RU Marking Standard on Hoffman brand

SECTION PANELBOARDS

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

PENDANT PUSHBUTTON STATIONS

EJB Junction Boxes Dimensions Pg. 132

PANELITE ENCLOSURE LIGHTS OVERVIEW

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Brasch Washdown Unit Heaters

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

Rack- and Panel-Mount Power Distribution Units (PDUs)

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Maintains NEMA Type 12 and IEC IP55 enclosure rating when properly installed per Hoffman instructions.

PanelView Plus/VersaView CE Terminals and Display Modules

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

SECTION SWITCHBOARDS

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Universal Tablet Enclosure 13 Inch and Under for Microsoft Surface Pro 3 and 4 PN MSPRO4

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

IP Enclosures Product Overview 2015

Rack- and Panel-Mount Power Distribution Units (PDUs)

DS185 1G FS Box Switch Cover. Features. Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Installation, Operation

Mounting Options. Maintains NEMA Type 12 and IEC IP55 enclosure rating when properly installed per Hoffman instructions.

SECTION SWITCHGEAR

Operator Interface Business

Vertiv VR Rack 1.0 GENERAL

TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)

DC Outdoor Power Supply/Chargers

WRD REMOVABLE HINGE PIN

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority

ROLLING COUNTER SHUTTERS

PowerFlex 750-Series Power Option Cabinets

Complete UL/CSA Disconnect Switch Kits

920 Remote Control (RC) Switches

Transcription:

763.422.2600 SPEC-00384 J763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL TWO-DOOR DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects TWO-DOOR STAINLESS STEEL ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS, TYPE 4X SPECIFICATIONS Manufactured from 12 gauge Type 304 stainless steel Seams continuously welded and ground smooth Body stiffeners in larger enclosures for extra rigidity Body flange trough collar excludes liquids and contaminants Removable centerposts permit easy panel installation Heavy-gauge continuous hinges Heavy-duty lifting eyes are Type 316 stainless steel Data pocket is high-impact thermoplastic 15-in. floor stands are welded to enclosure Seamless foam-in-place gasket provides oil-tight and dust-tight seal against contaminants Panel supports Collar studs provided for mounting optional panels Heavy-duty 3-point latching mechanism operated by Type 316 stainless steel POWERGLIDE padlocking handle on all doors Master door is right-hand door on X enclosures and left-hand door on CPX enclosures Type 316 stainless steel handle with defeater on master door Type 316 stainless steel handle (non-defeater) on slave door Mechanical interlock operated by master door prevents slave door from being opened first; doors can be closed in any order Preferred cutout on right flange provides mounting for most disconnect operators Bonding provision on doors; grounding studs on body Accessory mounting channel provided in enclosure top INDUSTRY STANDARDS UL 508A Listed; Type 3R, 4, 4X, 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 3R, 4, 4X, 12; File No. E61997 NEMA/EEMAC Type 3R, 4, 4X, 12 CSA File No. 42186: Type 4, 4X, 12 IEC 60529, IP66 Meets NEMA Type 3RX requirements FINISH Stainless steel enclosures are unpainted. Sides and body have smooth #4 brushed finish. Optional mild steel panels are painted white. Optional conductive panels are available. ACCESSORIES See also Accessories. Blank Adapter Plates, Mild Steel INTERSAFE Data Interface Ports, Type 4/4X/12 Operator Adapters for Universal Cutouts PANELITE Enclosure Lights Overview Panels for Type 3R, 4, 4X, 12 and 13 Enclosures Steel and Stainless Steel Window Kits MODIFICATION AND CUSTOMIZATION Hoffman excels at modifying and customizing products to your specifications. Contact your local Hoffman sales office or distributor for complete information. PATENTS US 5,634,357 D 385,7683 BULLETIN: A21S4 1 Disconnect SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Standard Product Two-Door with Provision for Disconnect Operator on Right Flange Panel Size Catalog Number AxBxC in./mm Panel Conductive Panel D x E in./mm A60X4912SSLPN4 60.12 x 49.79 x 12.12 1527 x 1265 x 308 A60P48 A60P48G 56.00 x 44.00 1422 x 1118 A60X6112SSLPN4 60.12 x 61.75 x 12.12 1527 x 1568 x 308 A60P60 A60P60G 56.00 x 56.00 1422 x 1422 A72X6112SSLPN4 72.12 x 61.75 x 12.12 1832 x 1568 x 308 A72P60 A72P60G 68.00 x 56.00 1727 x 1422 A72X7312SSLPN4 72.12 x 73.75 x 12.12 1832 x 1873 x 308 A60X4918SSLPN4 60.12 x 49.75 x 18.12 1527 x 1264 x 460 A60P48 A60P48G 56.00 x 44.00 1422 x 1118 A60X6118SSLPN4 60.12 x 61.75 x 18.12 1527 x 1568 x 460 A60P60 A60P60G 56.00 x 56.00 1422 x 1422 A72X6118SSLPN4 72.12 x 61.75 x 18.12 1832 x 1568 x 460 A72P60 A72P60G 68.00 x 56.00 1727 x 1422 A72X7318SSLPN4 72.12 x 73.75 x 18.12 1832 x 1873 x 460 A72X7324SSLPN4 72.12 x 73.75 x 24.12 1832 x 1873 x 613 Purchase panels separately. All 24.12-in. (613 mm) and deeper enclosures using short connecting rods in the following models require a Hoffman platform assembly, catalog number ADSCPA, purchased separately. ABB Controls flange-operated devices Eaton Cutler-Hammer C361 devices Eaton Cutler-Hammer C371 mechanisms which use C371E, F, G, K operating mechanism General Electric Type TDA devices (see next paragraph for option) Schneider Square D Class 9422 devices (see next paragraph for option) The platform assembly can be omitted if long connecting rods are ordered in place of short connecting rods. For Eaton Cutler-Hammer operating mechanisms C371E and C371F order catalog number C371CS1 connecting rod. For C371G and C371K order catalog number C371CS2 connecting rod. For General Electric devices, order catalog number TDSR extended length drive rod For Schneider Square D devices, order catalog number 9422- R2 extra long operating rod(s). Some devices require two rods. Consult factory for space occupied on panel when platform is used. EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.422.2600 pentairprotect.com Disconnect 2

Standard Product Two-Door with Provision for Disconnect Operator on Centerpost Panel Size Catalog Number AxBxC in./mm Panel Conductive Panel D x E in./mm A60CPX4812SSLPN4 60.12 x 48.50 x 12.12 1527 x 1232 x 308 A60P48 A60P48G 56.00 x 44.00 1422 x 1118 A60CPX6012SSLPN4 60.12 x 60.50 x 12.12 1527 x 1537 x 308 A60P60 A60P60G 56.00 x 56.00 1422 x 1422 A72CPX7212SSLPN4 72.12 x 72.50 x 12.12 1832 x 1842 x 308 A72CPX7218SSLPN4 72.12 x 72.50 x 18.12 1832 x 1842 x 460 Purchase panels separately. 3 Disconnect SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

DISCONNECT MOUNTING SPACE Disconnects will occupy space on panel shown by dimensions E1, F1, G1 and K. Wiring Space W1 is available when disconnect is installed in the enclosure. See the Technical Information chapter for E1 Spacing by Enclosure Height for various disconnect switch manufacturers. Refer to National Electrical Code, 2005 article 430-10(b) for wiring space required for line side conductors to be connected to disconnect. Verify your application to determine if wiring space is adequate. EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.422.2600 pentairprotect.com Disconnect 4

Notes 5 Disconnect SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Free-StandStainlessSteelPreferred-CutoutDisconnectsFree-StandPreferred-CutoutStainlessSteelDisconnectOverview FREE-STAND PREFERRED-CUTOUT STAINLESS STEEL DISCONNECT OVERVIEW PREFERRED-CUTOUT OVERVIEW Bulletin 140U flexible cable operating mechanisms for 140U molded case circuit breakers Bulletin 140G flexible cable and variable depth flange-mount molded case circuit breakers Bulletin 1494C cable-operated disconnect switches with flangemount handles Bulletin 194RC cable-operated flange-mount handles for use with the NFPA 79 compliant 194R IEC rotary disconnect switches Allen-Bradley Bulletin 1494V-R1, -R2 and -W2 operating handles and Allen-Bradley Bulletin 1494F disconnect devices or Bulletin 1494D circuit breaker operators will NOT fit these enclosures. ABB Controls flange-mount variable-depth operating mechanisms for disconnect switches and circuit breakers. Also the cable version for circuit breakers. Eaton Cutler-Hammer Type C361 flange-mount variable-depth operating mechanisms with disconnect switches and Type C371 flange-mount variable-depth operating mechanisms for circuit breakers. APPLICATION Enclosures having the preferred cutout are sized for use with up to 200A disconnect switches and up to 400A circuit breakers unless otherwise specified. The preferred cutout accepts the smaller operating handle whose mounting hole centers are 4.688 in. apart. Preferred cutouts are standard in mild steel wall-mount enclosures, modular enclosures and some select large mild steel enclosures. They are also present on all standard stainless steel offerings. 400 A (or greater) disconnect switches and 600 A (or greater) circuit breakers require the Large or High Amp cutout. This cutout accepts the larger operating handle whose mounting hole centers are 6.500-in. apart. This large cutout is only available on PROLINE-DD Disconnect Packages and Type 1 Free-Stand Enclosures. Operator adapter for preferred cutouts must be ordered separately to be used with A21S, A28S4, A4S and WS2D enclosures. Preferred cutouts are designed to house the following: Allen-Bradley Bulletin 1494V disconnect switches with flange-mount variabledepth operating mechanisms and Bulletin 1494V flange-mount variable-depth operating mechanisms for circuit breakers General Electric Type STDA flange handles and variable-depth operating mechanisms for disconnect switches and circuit breakers. Also SPECTRAFLEX cable operators for circuit breakers. Siemens ITE MAX FLEX flange-mount variable-depth operating handles for circuit breakers. Schneider Square D Class 9422 disconnect switches with flangemount variable-depth operating mechanisms or cable mechanisms and Class 9422 flange-mount variable-depth operating mechanisms or cable mechanisms for circuit breakers. These enclosures will NOT accept Square D Class 9422 bracketmounted disconnect devices, Class 9422TG1 or TG2 devices. ORDERING Order the disconnect switch, operating handle and operating mechanism separately. See Technical Information in the Hoffman Specifier s Guide for wire bend space available when various manufacturers disconnect switches are installed or Disconnect Ordering Information at pentairprotect.com for disconnect ordering guidelines and wire bend space available. Check the enclosure dimension drawings to verify the chosen disconnect switch will fit in the enclosure. EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.422.2600 pentairprotect.com Disconnect 6