Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Similar documents
Switch Mode Power Supply S8VT 120/240/480/960 W Models

S8VE (60/90/120/180/240-W Models)

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Voltage Current Front-mounting bracket

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Switching Power Supply

S82S (3/7.5-W Models)

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Switch Mode Power Supply

Switching Power Supply

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

S82J (10/25/50/100/150/300/600-W Models) CSM_S82J_DS_E_3_1

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Model Number Structure

Switch Mode Power Supply

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Switch Mode Power Supply

20A DRR Module / 40A DRR Module

Industrial Power Supplies

VP ELECTRONIQUE MASSY - Tel

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

PFE-S SERIES Single Output AC-DC Power Module UL / EN60950 Low Voltage Directive CSA C22.2 No Features Model naming method

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Industrial Power Supplies

Solid-state Timer H3YN

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)

12-15VDC (12V±5%) 24-28VDC (24V±5%)

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

Safety Relay Unit (I/O Unit Type)

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Switch Mode Power Supply. New Product

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Output Amps Model Number Output Voltage (max), (Note 2) Load Reg (max) Ripple & Noise pk-pk Efficiency typ.

Conductive Level Controller

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

12-15VDC (12V±5%) 24-28VDC (24V±5%)

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43

MMA-15 series. 15W Medical Grade Ultraminiature Switching Power Supplies. Single / Dual / Triple Outputs. Universal 90 to 264VAC Input

Model Number Structure

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Rhino PSM Power Supplies. Operating Instructions

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

SPECIFICATIONS: PSAK650

Model Number Structure

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Output Voltage* (nom.)(adjustable)

Series AM20EW-NZ 20 Watt DC-DC Converter

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

MINI-PS AC/10-15DC/8

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

Switching Power Supply S82G. Ordering Information. Dependable Power Supply for Demanding Industrial Applications

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

TEP 100WIR Series, 100 Watt

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

DIN Rail. user manual Models , & INT /503556/ UM

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

Switch Mode Power Supply. New Product

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

QUINT-PS/ 1AC/24DC/20/CO

CUS150M1 Instruction Manual

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

QUINT-PS/ 1AC/24DC/ 5

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Special-purpose Basic Switch

ABL8RPS24030 regulated SMPS - 1 or 2-phase V - 24 V - 3 A

Safety Standards. Model Number: Unit Weight:

Power Supply HARTING pcon

RTU500 series Data Sheet Power Supply CP-E 24/2.5

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

Table of Contents. 1 General 1.1 Scope

Transcription:

Three-phase Input Switch Mode Power Supply S8VT DIN-rail mounting, Power Supply with a range of 5 A to 40 A output current 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output Higher stability, lower ripple and noise level Compact design Fuses protection included Natural ventilation UL60950 (CSA22.2-60950), UL508 listing in addition to the CE mark Conform to EN61000-3-2 Parallel & serial operation possible Ordering Information S8VT Input voltage Power rating Output voltage Output current Model number 400 to 500 VAC 120 W 24 V 5 A S8VT-F12024E 3-phase 240 W 24 V 10 A S8VT-F24024E 480 W 24 V 20 A S8VT-F48024E 960 W 24 V 40 A S8VT-F96024E Model Number Legend S8VT - 1 2 3 E 1. Input Voltage F: 400 to 500 VAC 3-phase 2. Power Rating 120: 120 W 240: 240 W 480: 480 W 960: 960 W 3. Output Voltage 24: 24 V Three-phase Input Switch Mode Power Supply S8VT 1

Specifications Item Nominal Input Voltage F: 400 to 500 VAC Nominal Input Current 5 A 10 A 20 A 40 A Efficiency (400 VAC FULL LOAD) 86% 90% 91% 91% Input Voltage range 340 to 576 V 3AC resp. 480 to 810 VDC Frequency 50 to 60 Hz Current (max.) 0.5A 1A 1.5A 3A (Vin = Range min., Pmax) Power factor (400 VAC FULL 0.66 0.66 0.86 0.86 LOAD) Leakage current (max.) <3.5mA <3.5mA <3.5mA <3.5mA Inrush current (max.) < 30A @ Vin max. < 30A @ Vin max. < 40A @ Vin max. < 30A @ Vin max. (Pmax) EMI filter 2 10 mh 2 27 mh 2 6.8 mh 2 2.2 mh Line fuses T2A T3.15A T4A T6.3A Output Voltage adjustment range 21.6 to 28.0 VDC min. Tolerance adjustment accuracy 1% Ripple & noise (Pmax.) 100 mv max. (p.p. 0-20 MHz) variation influence ±0.5% max. Input variation influence ±0.25% max. Temperature variation influence Less than 0.05%/ C Startup time (max.) 1.3 s 1.3 s 1.3 s 1.3 s Hold time (min.) (Vin = 400 VAC) 15 ms 15 ms 15 ms 15 ms Protection - Short circuit protection continuative - Over load protection - Over voltage protection Parallel operation Yes (for two units) Serial operation Yes (for two units) Indicator Yes (Green LED) Others Heat radiation Natural air cooling Ambient temperature -10 to 70 C (de-rating: 5%/ C for 60 to 70 C) Temperature power derating 60 to 70 C see diagram Storage temperature -40 to 85 C Ambient humidity 10 to 90% noncondensing Dielectric strength 2.5 kvac Input-PE (for 1 sec.; routine test) 3 kvac Input-Output on isolation components (transformers) (for 1 sec.; high-pot routine test) 1 kvac Output-PE (for 1 sec.; routine test). Insulation resistance 500 Mohm min at 500 VDC, Output - P.E. Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude for 2 h each in X, Y and Z directions 10 to 150 Hz, 0.35 mm single amplitude for 80 min each in-x, Y and Z directions Shock resistance 150 m/s², 3 times each in ±X, ±Y, ±Z directions EMC EN55011 (EN55022) EN61000-3-2, EN61000-4-2, EN61000-4-3,EN61000-4-4,EN61000-4-5, EN61000-4-6,EN61000-4-8,EN61000-4-11, EN61204-3 Approval standards (AC and DC input) *1 For the 5 A and 10 A models UL is pending IEC60950-1, EN60950-1 UL60950-1, CSA 22.2 No. 60950-1, UL508 Listed *1, EN50178, EN60204 Life expectancy 10 years (Vin=400-500 VAC 50% of rated output current Ta=40 C) Weight 0.71 kg 0.91 kg 1.8 kg 3.3 kg 2 Three-phase Input Switch Mode Power Supply S8VT

Engineering Data Definition of Inrush Current, Start up Time and Hold Time Input ON Input OFF AC input voltage Inrush current input application AC input current 90% 95% Output voltage Start up time Hold up time Overload Protection The Power supply is provided with an overload protection function that protect the load and the power supply from possible damage by over current. When the output current rises above between 105 to 130% (105 to 120% for the 40 A model) of the rated current, the protection function is triggered, decreasing the output voltage. When output current falls within the rated range, the overload protection function is automatically cleared. De-rating Curve P Overvoltage Protection 5 A and 10 A models If output voltage exceed the rated voltage more than 25% (50% at maximum) by some reason, then the output voltage will be automatic limited for safety. 20 A and 40 A models If output voltage exceed the rated voltage more than 25% (50% at maximum) by some reason, then the output voltage will be turned OFF automatically for safety. To restart the S8VT, turn OFF the input voltage, wait few minutes, then apply the input power again. Pmax 50% 60 70 C For UL and CSA the maximum temperature is 60 C (70 C for the 20 A model) Three-phase Input Switch Mode Power Supply S8VT 3

Operation Block Diagram S8VT-F Vout+ AC-PH1 AC-PH2 AC-PH3 Input Line Fuses RFI filter Vout- P.E./Chassis Driver Control Module Opto-isolator Ouput Voltage Control Module 4 Three-phase Input Switch Mode Power Supply S8VT

Dimensions and Nomenclature Note: All dimensions shown are in millimeters. S8VT-F12024E 5 6 9 10 7 8 130 11 125 136 1 2 3 4 45 9.9 S8VT-F24024E 5 6 9 10 7 8 130 170 181 11 1 2 3 4 45 9.9 S8VT-F48024E 5 6 9 10 7 8 130 170 181 11 1 2 3 100 4 9.9 S8VT-F96024E 195 130 170 181 11 1 2 3 4 5 6 7 8 9 10 9.9 1. AC input L1 2. AC input L2 3. AC input L3 4. P.E. (Protective Earth) 5. LED Vout ok 6. Vadj. Trim 7. Vout + 8. Vout + 9. Vout - 10.Vout - 11.DIN-rail clip Three-phase Input Switch Mode Power Supply S8VT 5

Notice Three phase input operation when one phase is missing The S8VT will in most cases continue to operate even after the loss of one phase of the supply. The performance specifications are of course not guaranteed under these conditions. As the loss of one phase puts additional stress on some components, the life span of the unit could be shortened. It is prudent therefore to regularly check for signs of the following possible conditions. 1. Input terminals wiring open/loose. 2. Incorrect/No voltage on one or more phases of the supply. 3. Abrupt or periodical loss of input voltage. The power supply needs output derating as in the chart for the operation on missing phase at the input voltage range of 340 to 576 V. Otherwise, the power supply may deteriorate or be damaged. In every single application suitability has to be checked. Note: In two phase operation, the specification for EMC performance, hold-up time, efficiency and output ripple will no longer be valid. Three phase input switch off In order to switch off the Power Supply completely: All 3 phases need to be switched off. Mounting (%) 110 100 90 80 70 60 50 40 30 20 10 0-20 -10 0 10 20 30 40 50 60 70 80 Ta ( C) To improve and maintain the reliability of the Power Supply over a long period, adequate consideration must be taken to heat radiation. The S8VT is designed to radiate heat by natural air cooling, therefore, mount the S8VT so that enough air flow takes place around the power supply. If installing S8VTF closely, keep the minimum distance of 20 mm at 60 C ambient. Generating (±) Output Voltage Missing phase de-rating S8VT-F12024E S8VT-F48024E S8VT-F24024E S8VT-F96024E An output of ± can be generated as shown below, since the S8VT has a floating output. Serial Operation As shown below, the output voltage from each S8VT can be added. Types must be the same. Parallel Operation As shown below, two S8VT-F (same capacity model) can be paralleled to boost the output power (current). Set the output voltages of the Power Supplies to the same value. Also, make sure that the thickness and the length of all wires connected to the load are the same to ensure that the wires will have no voltage drop difference. Parallel connection is only permissible with ambient temperature from -10 C to +50 C. In case of a redundant system or back-up system, use diode to be connected to output + terminal of all the Power Supplies. + V V + V V +V V +V V + V V + V V 6 Three-phase Input Switch Mode Power Supply S8VT

Safety Precautions Safety Signal words This document uses the following signal words to mark safety precautions for the S8VT. These precautions provide important information for the safe application of the product. You must be sure to follow the instructions provided with safety signal words.!warning Indicates information that, if ignored, could possibly result in loss of life or seriously injury.!caution Indicates information that, if ignored, could result in relatively serious or minor injury, damage to the product, or faulty operation.!warning Be sure to connect the grounding line. Not doing so may result in electric shock.!caution Do not attempt to disassemble the Power Supply or touch its internal parts while power is being supplied. Doing so may result in electric shock.!caution Do not touch the S8VT while the power is being supplied or immediately after the power is turned OFF. The case of the Power Supply can be still hot. Three-phase Input Switch Mode Power Supply S8VT 7

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. M03E-EN-01 In the interest of product improvement, specifications are subject to change without notice. 8 Three-phase Input Switch Mode Power Supply S8VT