Hitachi Compute Blade 2000 LSI MegaRAID SAS 2208 RAID controller firmware update User s Guide

Similar documents
Hitachi Compute Blade 500/2500 LSI MegaRAID SAS 3004 (imr) firmware update User s Guide

Hitachi Compute Rack Series RAID Driver Instruction Manual For Red Hat Enterprise Linux

Hitachi Compute Blade CB Base-T 4-port LAN Adapter User's Guide

BBI Quick Guide Networking OS for 1/10Gb LAN Switch Module

Hitachi Compute Blade HVM Navigator Installation Manual

Hitachi Compute Blade 2500 Intel LAN Driver Instruction Manual for SUSE Linux Enterprise Server

Hitachi Compute Blade 500 Series

Use Restrictions for Hitachi Compute Blade 500 Series FASTFIND LINKS. Getting Help Contents MK-91CB

Hitachi Compute Blade Installation Guide for Oracle Linux OS Installation Guide

Hitachi Compute Blade Installation Guide for Oracle Solaris OS Installation Guide

Hitachi Compute Blade Logical VGA SnapShot

Hitachi Data Ingestor

Use Restrictions for Hitachi Compute Blade 2500 Series FASTFIND LINKS. Getting Help Contents MK-99CB

Hitachi Data Ingestor

Hitachi Data Ingestor

Hitachi Compute Blade HVM Navigator User s Guide - LPAR Configuration

Hitachi Compute Blade HVM Navigator User s Guide - LPAR Configuration

Hitachi NAS Platform F1000 Series

Hitachi Server Adapter for the SAP HANA Cockpit

Use Restrictions for Hitachi Compute Blade 500 Series FASTFIND LINKS. Getting Help Contents MK-91CB

Hitachi Data Ingestor

Hitachi Compute Blade Emulex Adapter User's Guide for Driver

Use Restrictions for Hitachi Compute Blade 500 Series. Getting Help Contents MK-91CB

Hitachi Command Suite. Automation Director. Messages MK-92HC221-02

Hitachi Virtual Storage Platform G1000

Hitachi Content Platform HCP Data Migrator 6.1 Release Notes HCP-DM Version June 27, 2014

Hitachi WAN Optimizer VMware vsphere Setup Guide

Hitachi Compute Blade 2500 Series

BBI Quick Guide Networking OS for 1/10Gb LAN Switch Module. Product Version Getting Help Contents

Hitachi Compute Blade Series Hitachi Compute Rack Series

Hitachi Converged Adapter 2.0 for VMware vcenter Operations HCA for vc OPs Third-Party Copyrights and Licenses

Hitachi Unified Storage VM Block Module

Hitachi Storage Connector for VMware vrealize Orchestrator

Hitachi Compute Blade 500 Series

Hitachi Data Ingestor

Hitachi Storage Command Portal Installation and Configuration Guide

Hitachi Compute Blade Series Logical Partitioning Manager Version Upgrade / Revision Update Guide

Hitachi Data Instance Director

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User s Guide alive monitoring functions

Hitachi Storage Adapter for Microsoft Windows PowerShell

Mainframe Analytics Recorder v Release Notes

Hitachi Converged Adapter 2.0 for Microsoft SCOM 2012 Administration Manual HCA for SCOM Administration Manual

Replication Manager. Hitachi Command Suite. Application Agent CLI Reference Guide MK-90HC Document Organization. Product Version.

Hitachi Command Suite. Command Director. CLI Reference Guide MK-90HCMD004-04

Hitachi Compute Blade 500 Series

Tuning Manager. Hitachi Command Suite. Getting Started Guide MK-96HC FASTFIND LINKS Document Organization. Product Version.

Hitachi Data Ingestor

Hitachi Virtual Storage Platform

Hitachi Compute Blade 2500 Series

Hitachi Command Suite

Hitachi Dynamic Link Manager (for AIX) Release Notes

Hitachi Command Suite

Hitachi Command Suite. Automation Director. Installation and Configuration Guide MK-92HC204-02

Hitachi Command Suite. Dynamic Link Manager. (for VMware ) User Guide. Document Organization. Product Version. Getting Help. Contents MK-92DLM130-12

Hitachi Hyper Scale-Out Platform (HSP) Hortonworks Ambari VM Quick Reference Guide

Hitachi Device Manager Mainframe Agent Release Notes Contents

Hitachi Data Ingestor Hyper-V Installation Guide 6.0.0

Hitachi Data Ingestor

Hitachi Command Suite. Tuning Manager. Server Administration Guide. FASTFIND LINKS Contents. Product Version. Getting Help MK-92HC021-39

Hitachi Command Suite

Compute Systems Manager

Hitachi Data Systems. Hitachi Virtual Storage Platform Gx00 with NAS Modules NAS Platform (System LU) Migration Guide MK-92HNAS078-00

Hitachi Compute Blade 2500 Series

Hitachi Virtual Storage Platform

Hitachi Data Instance Director Disaster Recovery Reference

Hitachi Dynamic Link Manager (for AIX) Release Notes

Hitachi Dynamic Link Manager (for AIX) v Release Notes

Hitachi Command Suite

Hitachi Compute Blade Series Hitachi Compute Rack Series Server Installation and Monitoring Tool User s Guide Log Collect Functions for VMware vma

Hitachi Compute Blade 500 Series

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Storage Navigator Messages

Hitachi Data Systems. Hitachi Dynamic Provisioning with HNAS v12.1 Frequently Asked Questions MK- 92HNAS057-02

Global Link Manager. Hitachi Command Suite. Installation and Configuration Guide MK-95HC Document Organization. Product Version.

Hitachi Infrastructure Adapter for Microsoft System Center Operations Manager

Hitachi Dynamic Link Manager (for VMware ) Release Notes

Hitachi Compute Blade 500 Series

Hitachi Virtual Storage Platform G1000

Hitachi Virtual Storage Platform G1000

Hitachi Virtual Storage Platform G1000

Hitachi NAS Platform F

Hitachi Data Instance Director

Hitachi Global Link Manager Release Notes

Hitachi Virtual Storage Platform

Hitachi Compute Blade 500 Series

Compute Systems Manager

Hitachi Storage Adapter for Microsoft System Center Virtual Machine Manager

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide internal storage monitoring functions

Contents. About This Document Intended Audience Getting Help Hardware and Software Support Storage Models (All adapters)...

HCP Data Migrator Release Notes Release 6.1

Hitachi Adapter for Oracle Enterprise Manager - Database Cloning

Hitachi Command Suite. Dynamic Link Manager. (for Windows ) User Guide. Document Organization. Product Version. Getting Help. Contents MK-92DLM129-34

Hitachi Adapters for Oracle Database

Hitachi Storage Adapter for Oracle Recovery Manager

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Copy-on-Write Snapshot User s Guide

Hitachi Data Center Analytics v7.0 Release Notes

Hitachi Data Ingestor

Hitachi Compute Blade 500 Series

Hitachi Virtual Storage Platform G1000

Hitachi Virtual Storage Platform G1000

Hitachi Command Suite. Tuning Manager. User Guide. Document Organization. Product Version. Getting Help. Contents MK-92HC022-39

Transcription:

Hitachi Compute Blade 2000 LSI MegaRAID SAS 2208 RAID controller firmware update User s Guide FASTFIND LINKS Document organization Product version Getting help Contents MK-99BDS2K105-02

2010-2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose without the express written permission of Hitachi, Ltd. Hitachi, Ltd., reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. This document contains the most current information available at the time of publication. When new or revised information becomes available, this entire document will be updated and distributed to all registered users. Some of the features described in this document might not be currently available. Refer to the most recent product announcement for information about feature and product availability, or contact Hitachi Data Systems Corporation at https://portal.hds.com. Notice: Hitachi, Ltd., products and services can be ordered only under the terms and conditions of the applicable Hitachi Data Systems Corporation agreements. The use of Hitachi, Ltd., products is governed by the terms of your agreements with Hitachi Data Systems Corporation. Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries. Hitachi Data Systems is a registered trademark and service mark of Hitachi, Ltd., in the United States and other countries. Archivas, Essential NAS Platform, HiCommand, Hi-Track, ShadowImage, Tagmaserve, Tagmasoft, Tagmasolve, Tagmastore, TrueCopy, Universal Star Network, and Universal Storage Platform are registered trademarks of Hitachi Data Systems Corporation. AIX, AS/400, DB2, Domino, DS6000, DS8000, Enterprise Storage Server, ESCON, FICON, FlashCopy, IBM, Lotus, MVS, OS/390, RS6000, S/390, System z9, System z10, Tivoli, VM/ESA, z/os, z9, z10, zseries, z/vm, and z/vse are registered trademarks or trademarks of International Business Machines Corporation. All other trademarks, service marks, and company names in this document or website are properties of their respective owners. Microsoft product screen shots are reprinted with permission from Microsoft Corporation. ii

Contents Contents...iii Preface... v Intended audience...vi Product version...vi Release notes...vi Document organization...vi Document conventions... vii Convention for storage capacity values... viii Getting help... viii Comments... viii Firmware version check... 1-1 Firmware version check...1-2 Firmware update... 2-1 Firmware update...2-2 Acronyms and Abbreviations... 1 Contents iii

iv Contents

Preface This document describes how to use the RAID firmware update tool CD. This preface includes the following information: Intended audience Product version Release notes Document organization Document conventions Convention for storage capacity values Getting help Comments Notice: The use of the RAID firmware update tool CD and all other Hitachi Data Systems products is governed by the terms of your agreement(s) with Hitachi Data Systems. Preface v

Intended audience This document is intended for the personnel who are involved in planning, managing, and performing the tasks to prepare your site for Compute Blade installation and to install the same. This document assumes the following: The reader has a background in hardware installation of computer systems. The reader is familiar with the location where the Compute Blade will be installed, including knowledge of physical characteristics, power systems and specifications, and environmental specifications. Product version This document revision applies to the RAID firmware update tool CD version 01-00-015. Release notes Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document. Document organization The following table provides an overview of the contents and organization of this document. Click the chapter title in the left column to go to that chapter. The first page of each chapter provides links to the sections in that chapter. Chapter Chapter 1, Firmware version check Chapter 2, Firmware update Description This chapter explains how to check a RAID controller firmware version. This chapter explains how to update RAID controller firmware. vi Preface

Document conventions This document uses the following typographic conventions: Convention Regular text bold Italic Screen text Description In text: keyboard key, parameter name, property name, hardware labels, hardware button, hardware switch. In a procedure: user interface item Variable, emphasis, reference to document title, called-out term Command name and option, drive name, file name, folder name, directory name, code, file content, system and application output, user input < > (angled brackets) Variable (used when italic is not enough to identify variable). [ ] (square bracket) Optional values { } braces Required or expected value vertical bar Choice between two or more options or arguments _(underline) Default value, for example, [a b] This document uses the following icons to draw attention to information: Icon Meaning Description NOTICE WARNING CAUTION NOTICE Note This indicates the presence of a potential risk that might cause death or severe injury. This indicates the presence of a potential risk that might cause relatively mild or moderate injury. This indicates the presence of a potential risk that might cause severe damage to the equipment and/or damage to surrounding properties. This indicates notes not directly related to injury or severe damage to equipment. Tip This indicates advice on how to make the best use of the equipment. Preface vii

Convention for storage capacity values Physical storage capacity values (for example, disk drive capacity) are calculated based on the following values: Physical capacity unit Value 1 kilobyte (KB) 1,000 (10 3 ) bytes 1 megabyte (MB) 1,000 KB or 1,000 2 bytes 1 gigabyte (GB) 1,000 MB or 1,000 3 bytes 1 terabyte (TB) 1,000 GB or 1,000 4 bytes 1 petabyte (PB) 1,000 TB or 1,000 5 bytes 1 exabyte (EB) 1,000 PB or 1,000 6 bytes Logical storage capacity values (for example, logical device capacity) are calculated based on the following values: Logical capacity unit Value 1 block 512 bytes 1 KB 1,024 (2 10 ) bytes 1 MB 1,024 KB or 1,024 2 bytes 1 GB 1,024 MB or 1,024 3 bytes 1 TB 1,024 GB or 1,024 4 bytes 1 PB 1,024 TB or 1,024 5 bytes 1 EB 1,024 PB or 1,024 6 bytes Getting help Comments The Hitachi Data Systems customer support staff is available 24 hours a day, seven days a week. If you need technical support, log on to the Hitachi Data Systems Portal for contact information: https://portal.hds.com Please send us your comments on this document: doc.comments@hds.com. Include the document title and number including the revision level (for example, -07), and refer to specific sections and paragraphs whenever possible. All comments become the property of Hitachi Data Systems Corporation. Thank you! viii Preface

1 Firmware version check This chapter describes the firmware version check for CB 2000 Standard Server Blade with the LSI MegaRAID SAS 2208 RAID controller. Firmware version check Firmware version check 1-1

Firmware version check Check the firmware version of LSI MegaRAID SAS 2208 RAID controller that is installed in CB 2000 standard server blade in accordance with the following procedure. Check the firmware version after closing all programs, because the system unit is restarted during the operation. Firmware version check through OS When you check the firmware version through OS, MegaCli must be installed in the system unit. If MegaCli is not installed or you cannot find the folder in which to store MegaCli, see Firmware version check through MegaRAID Web BIOS to check the firmware version. 1. Log on as a user, which have administrative privileges, OS. Windows: Administrator privileges Linux or VMware: root privileges 2. Start a command prompt, and move to a folder that MegaCli is stored. Windows: MegaCli is stored in a folder that MSM (MegaRAID Storage Manager) is stored. As default, MSM is installed in the following directory. Windows 64-bit: C:\Program Files (x86)\megaraid Storage Manager Windows 32-bit: C:\Program Files\MegaRAID Storage Manager Linux: MegaCli is stored in "/opt/megaraid/megacli" folder. (When MegaCli is installed.) VMware: There is no fixed place to store MegaCli. 1-2 Firmware version check

3. Execute the following command. Windows 32-bit: #.\MegaCli -adpallinfo -aall -nolog >.\RAIDInfo.txt Windows 64-bit: #.\MegaCli64 -adpallinfo -aall -nolog >.\RAIDInfo.txt Linux or VMware: #./MegaCli -adpallinfo -aall -nolog >./RAIDInfo.txt Type the command correctly for Linux, because Linux is case sensitive. 4. RAIDInfo.txt is created in the same folder stored MegaCli after executing the command. 5. Search the RAIDInfo.txt file for strings while referring to the following procedure. (1) Search for Product Name as string. (RAID controller name) (2) Search for FW Version as string. (Firmware version) Product Name FW Version. : xxxxxxxxxxxx. : x.xxx.xxx-xxxx. RAID controller name Firmware version 6. Check the hit string from searching. Product Name FW Version Firmware LSI MegaRAID SAS 9266-8i 3.152.185-3520 No update available Version other than Update available 3.152.185-3520 7. If the firmware version is Update available, need to update to the latest version. If the firmware version is No update available or Product Name is other than LSI MegaRAID SAS 9266-8i as above table, firmware does not need update. Quit this procedure. Firmware version check 1-3

Firmware version check through MegaRAID Web BIOS 1. Turn on the system unit. Restart the system unit when the OS is already booted. 2. When the following window is displayed while starting up, press Ctrl key and H key. LSI MegaRAID SAS-MFI BIOS Version x.xx.xx(build xxxx xx, xxxx) Copyright(c) xxxx LSI Corporation HA -0 (Bus xx Dev xx) LSI MegaRAID SAS 9266-8i FW package: xx.xx.x-xxxx x Virtual Drive(s) found on the host adapter. x Virtual Drive(s) handled by BIOS Press <Ctrl><H> for Web BIOS 3. The following window is displayed. Adapter No. Bus No. Device No. Type Firmware Pkg.Version 0.(o) x 0 LSI MegaRAID SAS 9266-8i x.xxx.xxx-xxxx Start 4. Check the RAID controller firmware version. Type Firmware Pkg.Version Firmware LSI MegaRAID SAS 9266-8i 23.2.1-0065 No update available Version other than Update available 23.2.1-0065 5. If the firmware version is Update available, need to update to the latest version. If the firmware version is No update available or Type is other than LSI MegaRAID SAS 9266-8i as above table, firmware does not need update. Quit this procedure. 1-4 Firmware version check

2 Firmware update This chapter describes the firmware update for CB 2000 Standard Server Blade with the LSI MegaRAID SAS 2208 RAID controller. Firmware update Firmware update 2-1

Firmware update Update the firmware of LSI MegaRAID SAS 2208 RAID controller in CB 2000 standard server blade in accordance with the following procedure. Update the firmware after closing all programs, because the system unit is restarted during the operation. The firmware automatically update. It takes about 20 minutes for firmware update. 1. Let the system recognize the RAID firmware update tool CD as follows. (1) Use the remote CD/DVD function of the remote control application to recognize the CD drive. Using the remote CD/DVD function, do not load the CD as a CD image, then attempt to recognize the image. This method is not supported. For the use of the remote CD/DVD function, see the Remote Console Application User's Guide that comes with the unit. If the remote CD/DVD function is already active, once disable it, and then reenable it. (2) Insert the CD into the CD/DVD drive. 2-2 Firmware update

2. Please refer to "Hitachi Compute Blade 2000 User's Guide" and Start System BIOS menu. And Set System to boot up from CD/DVD drive. 3. Turn on the system unit. 4. The following window is displayed after CD boot. Wait 30 seconds. LSI MegaRAID SAS 2208 ROMB (MegaRAID) Firmware Update/Parameter Set Tool Ver.01-00(20xx/xx/xx) -xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx model -xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx model Firmware Update to Ver. 3.152.185-3520 (Package Ver. 23.2.1-0065) If press Enter key, the menu is displayed, and press R key. The system unit is restarted, therefore, set this procedure again. 5. The following window is displayed, and update will be started. Adapter X: XXXXXXXXXXXXXXXXXXXXXXXX Vendor ID: 0xXXXX, Device ID: 0xXXXX Download Completed. Flashing image to adapter... The following message of mouse is displayed while updating. This message is not problem. DOS/32A warning (9004): mouse initialization failed It takes 2 minutes to update. Firmware update 2-3

6. The system unit automatically restart after the firmware update. 7. The following window is displayed after CD boot. Wait 30 seconds. LSI MegaRAID SAS 2208 ROMB (MegaRAID) Firmware Update/Parameter Set Tool Ver.01-00(20xx/xx/xx) -xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx model -xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx model Firmware Update to Ver. 3.152.185-3520 (Package Ver. 23.2.1-0065) If press Enter key, the menu is displayed, and press R key. The system unit is restarted, therefore, set this procedure again. 8. Version is checked, and the following message is displayed. C:> OOOOOO KK KK OOO OOO KK KK OO OO KK KK OO OO KK KK OO OO KKKKKKK OO OO KK KK OO OO KK KK OO OO KK KK OO OO KK KK OOO OOO KK KK 000000 KK KK 9. Remove the CD from the CD/DVD drive. 10. If System already set to boot up from CD/DVD drive, Please refer to "Hitachi Compute Blade 2000 User's Guide" and start System BIOS menu. And return the setting. The firmware update is completed. 2-4 Firmware update

Acronyms and Abbreviations CD DVD OEM OS RAID VD Compact Disc Digital Versatile Disc Original Equipment Manufacturer Operating System Redundant Arrays of Inexpensive Disks Virtual Drives Acronyms and Abbreviations Acronyms-1

Acronyms-2 Acronyms and Abbreviations

Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California 95050-2639 U.S.A. www.hds.com Regional Contact Information Americas +1 408 970 1000 info@hds.com Europe, Middle East, and Africa +44 (0) 1753 618000 info.emea@hds.com Asia Pacific +852 3189 7900 hds.marketing.apac@hds.com MK-99BDS2K105-02