v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

Similar documents
Tarleton State University. Specifications

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

Siemon PON Fiber Cabling Solutions

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

Data Cabling / Low Voltage Technology Specifications

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

LACCD IT Design Standards

ANSI/TIA/EIA-568-B Cabling Standard

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Target Interface / Construction Compliance Inspection Checklist

f) Telecommunications Equipment Rooms

Telecommunications Structured Cabling Systems

Communications. UNM IT/Telecommunications Guide Specification Communications

Peter Sharp RCDD IBI Group

The Riser as a Contract Document. Peter Sharp, RCDD

FIBER OPTIC HARDWARE STEVE PAULOV

TIA/EIA 568A Sub-system HORIZONTAL CABLING

2.3 SCOPE OF WORK MATRIX TO BE INCLUDED IN DISTRICT PROJECTS

Classroom WiFi Network Infrastructure Plan

E. Numbering and Labeling Pathway components. In general, pathway components are not labeled.

Power/Data Instructions. Genius. Movable Walls. September

Cabling a Data Center to TIA-942 Standard

Cabinet Location Plan FIG.01. Cabinet Symbol Key. Air Handler. Air Handler SAN disk storage. SAN disk storage. option B. Not To Scale.

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES

SPECIFICATION STANDARD

ANSI/TIA/EIA-568-B Cabling Standard

The six major components of a structured wiring system are:

Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution

Total Amount Carried Forward To Bill summary Page

CCBC is equipped with 3 computer rooms, one at each main campus location:

Technology Standards

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

Saving Critical Space. Cable Management Solutions

FTTE Revisited for New Technologies

Powering HP BladeSystem c7000 Enclosures

Los Angeles Community College District Design Standards

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

NOCCCD Cabling Infrastructure Standards - Page 1

CELL SITE INFRASTRUCTURE SOLUTIONS. Creative Solutions for the Mobile Evolution

Universal connectivity grid design guide

Fiber Backbone Cabling in Buildings

Fiber Optic System. Fiber Optic System. Fiber Optic Rack Mount Solutions

How You Can Optimize Passive Optical LAN Through Structured Cabling

PHYSICAL INFRASTRUCTURE QUICK SKU FINDER

Structured Cabling Guidelines

SECTION TELEPHONE AND COMPUTER CABLING

Target Interface / Construction Compliance Inspection Checklist

Design Guidelines for Facilities Construction:

ARIADROP: Fiber to the MDU (FTTM)

Fiber backbone cabling in buildings

General. Exterior Cameras. Camera Towers

Communications Infrastructure Specification

Target Interface / Construction Compliance Inspection Checklist

Division 27 Master Specification for

Powered fiber cable system technical overview: Hybrid optical fiber system for extending Power over Ethernet (PoE)

Netfinity White Paper Netfinity Technology Center

Polycom KIRK KWS300 Base Units

C o n n e c t o r s C h a p t e r 183

1 QUESTIONS/Answers PAGE 1 OF 10. Addendum 2 Request for Proposal FY Voice Data and Infrastructure Cable

Target Interface / Construction Compliance Inspection Checklist

SECTION COMMON WORK RESULTS FOR COMMUNICATIONS

The following pages contain a guide for the installation

COMMON WORK RESULTS FOR COMMUNICATIONS

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

Newark, Delaware Architectural Engineering Senior Thesis Portfolio

UMass Lowell. October 1, Network and Voice Infrastructure Specifications Prepared by Network Engineering and Network Project Management

RMG Series Rack Mount Fiber Enclosures

24-Port Gigabit Ethernet Switch w/ 12 Outlet PDU, 2 SFP and 8 PoE+ Ports, 120W

ProCliCk Pre-Polished ConneCtors

LC Connector. A High Density Fiber Optic Network Solution. Paul Kolesar Lucent Technologies, Bell Laboratories

Cabling Infrastructure

Computer Network Design Guide Existing Systems 1 / 6

Master Format Division 27 - Communications

A New Standards-Based Structured Cabling System Architecture

WIREMOLD. innovative wire and cable management

3M Passive Optical Splitter Shelves and Modules

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring

V-Built Custom Preconfigured Solutions

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

New Standardized Cabling Options for NBASE-T Devices

Cabling Infrastructure

ISO/IEC 11801: (E)

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS

WORLDSKILLS STANDARD SPECIFICATION

Ultra High Density Fiber Enclosure

UNIVERSITY OF CALICUT (Purchase Division)

SECTION 2 DIVISION 27 UNC CHARLOTTE ITS DEPARTMENT. ITS Telecommunications Standards - Specifications Manual for Construction and Renovations

Structured Cabling Guidelines For The State Of Oregon

Wireless Enclosures from Wiremold/Legrand

This attractive raceway conceals and

Brown University June 22, 2015 Facilities Design & Construction Standards SECTION COMMUNICATIONS

Copper Riser And Intrabuilding Cabling

York Region Information Technology Services. Standards and Guidelines. Cabling and Wiring for Voice and Data Communications

Closet Connector Housings (CCH)

GUILFORD COUNTY SCHOOLS IFB Wireless Data Outlet Installation Group 4 PACE Mobile Units September 27, 2013 Addendum 1

Transcription:

Changes in v2.6: v2.5 was updated May 10, 2016. v2.6 is an updated copy from March 1, 2017. Modifications to 4. Horizontal Pathways section with feedback incorporated from UofA Facilities and Operations Electrical Trades. Removal of Payphones section. 4. Horizontal Pathways C. Raceway Systems Expanded Perimeter Raceway Systems section and added Raceways Inside Rooms, including recommended suggestions. Reason for change: updates from UofA Facilities and Operations Electrical Trades Removal of section: 6. Miscellaneous B. Payphones Reason for change: payphones are being removed from campus Changes in v2.5: v2.4 was updated May 2, 2016. v2.5 is an updated copy from May 10, 2016. Addition of Appendix B: Typical Telecommunications Room Layout 3. Requirements for Telecommunications Spaces G. Electrical Power VoIP equipment requires a 220V/20A emergency power outlet the connector must have the ability to mate with a HBL2321 power connector. (was: 250V)

Reason for change: correction to power voltage - 220V 9. Additional U of A Cabling Requirements A. Voice over Internet Protocol (VoIP) The power requirements are a minimum of one NEMA L6-20R locking female receptacle connected to a 220 volt 20 amp circuit on UPS power. (was: emergency power) Reason for change: clarification that emergency power fed by generator is not required, but an uninterruptible power supply (UPS) is required for VoIP deployments 8. Additional U of A Cabling Specifications Singlemode fiber to be fusion spliced (Preferably by IST) Reason for change: clarify splicing on singlemode fibre Fiber patch panels to be used at all locations, IST to determine type/brand of enclosure to suit the location (i.e. Siemon depending on location and proper adapter strips depending on terminations) (was: Nordx or AMP) Reason for change: updated preferences 10. References Telecommunications Distribution Method Manual (TDMM) 13th Edition by Building Industry (was: 10th) Changes in v2.4: v2.3 was updated April 29, 2016. v2.4 is an updated copy from May 2, 2016. 5. Telecommunications Outlets A. Standard Wall Outlets [The gang box] is mounted flush in the wall at same height as the convenience electrical outlet-- 12" AFF.

(was: 18" AFF) Consider furniture designs when determining outlet placement. Wall ports must remain accessible for terminations, testing, and future troubleshooting. Reason for change: meet electrical outlet height, and 18 may be too high for furniture with modesty panels A TO for a wireless access point should be no more than 3 feet away from the specified wireless access point location. IST is responsible for wireless design and wireless access point placement. (was: A TO for wireless access point is mounted high on the wall at least 4" below the drop ceiling.) REMOVAL of lines: The wireless access point transmitter has an 8"X10" off white decorative plastic cover that protrudes four inches from the wall. Very small green indicator lights "LEDs" are visible from the bottom of the cover. Reason for change: updated preferences for wireless access points Changes in v2.3: v2.2 was last updated February 5, 2009. v2.3 is an updated copy from April 29, 2016. It includes: Minor wording changes and corrections. Rename of AICT to IST Addition of Appendix A: Requirements for copper and fiber installations 1. General Specification Guidelines ANSI/TIA/EIA-568-C.3 Optical Fiber Cabling Components Standard (was: ANSI/TIA/EIA-568-B.3) Reason for change: updated standard

3. Requirements for Telecommunications Spaces A. Location Telecommunication room (TR) placement should be discussed with IST and IST must approve the final design drawings. Quantity of TRs in a building should be kept to a minimum. (was: and at least one smaller telecommunications room (TR) is required on each floor above.) Reason for change: building design and networking requirements vary too much by building to give authoritative direction. If a TR is not required on every floor, then building space is wasted. Consultation with IST is the best way to allocate space appropriately. 3. Requirements for Telecommunications Spaces G. Electrical Power VoIP equipment requires a 250 220V/20A emergency power outlet the connector must have the ability to mate with a HBL2321 power connector. (was: HBL2621) Reason for change: vendors have changed 3KVA UPS plugs to NEMA L6-20R compatible 3. Requirements for Telecommunications Spaces M. Service Corridors Flame test rating of FT6 (CSA) (was: FT4) Indoor/outdoor fibre cables are preferred when running cables through the service corridor. Reason for change: updated standards and preferences 4. Horizontal Pathways E. Homerun Conduits Power over Ethernet (PoE) devices such as wireless access points (APs) must have a home run to the telecommunication room (TR) that contains the PoE network switch. Patching between floors or between different TRs is not acceptable. Reason for change: clarification of requirements for PoE devices such as wireless access points 5. Telecommunications Outlets

A. Standard Wall Outlets REMOVAL of line: There must be an electrical outlet next to every wireless TO to power the wireless access point transmitter that will be mounted on the wall. Reason for change: Power over Ethernet (PoE) supplies wireless access points with power. No other power source is required except where the network switch does not supply PoE. Requirement to use PoE switches with any new University Wireless Service (UWS) deployment. 5. Telecommunications Outlets E. Modular Furniture Wall ports must remain accessible for terminations and testing. Reason for change: Furniture impeding wall ports requires movement of furniture and delays the finalized installation of ports. 8. Additional U of A Cabling Specifications Fibre Requirements Multimode 50μm OM4 minimum (was: Multi Mode 62.5μm minimum Corning InfiniCor 300 or 1000 or equivalent 50μm minimum Corning InfiniCor 600 or 2000 or equivalent) Indoor use FT-6 rated, tight buffered (was: FT-4 rated) Termination to be LC connectors (was: ST connectors) Reason for change: updated standards and preferences 8. Additional U of A Cabling Specifications Connectivity Hardware Data Jacks: Hubbell (violet in color) PBX Voice Jacks: Hubbell (white in color) (was: - Current primary for data: Hubbell (violet in color) - Secondary: Panduit (violet in color) - Voice: Not specified (Black, White, Beige or Gray colors only) )

Reason for change: updated preferences 9. Additional U of A Cabling Requirements A. Voice over Internet Protocol (VoIP) 1. The power requirements are a minimum of one NEMA L6-20R locking female receptacle connected to a 220Volt 20 AMP circuit on emergency power. The power should be mounted on the wall close enough to so that no extension cord is required. (was: Mounted over top of rack or bottom of tray feeding the relay rack design. Mounted at the top or bottom of the relay rack. Mounted on the wall close enough to so that no extension cord is required. Mounted in a receptacle box with a movable (4 ft) power cable. ) Reason for change: power mounted above the rack is no longer preferred