North American Service Manual

Similar documents
COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery.

Digital Indicator. Revision 1.6 March 15, Transcell Technology, Inc. Contents subject to change without notice.

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

Digital Weight Indicator Setup / Operation Manual

Model S200 Series. Revision 1.0 July, Contents subject to change without notice.

TI-500 Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual

TI-1600 Series. Digital Indicator. Setup / Operation Manual. Revision 1.5 June 5, 2006

DCS Series. Digital Counting Scale. Setup Manual

Digital Bench Scale. Revision 8.93 August 12, 1993

600-E Series. Digital Baggage Scales. Installation / Setup / Operation Manual. Revision 2.3 June 5, Triner Scale & Mfg. Co., Inc.

PC 150. Digital Bench Scale. Operation Manual

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

Calibration & Connectivity

Revision 1.0 July, Contents subject to change without notice.

Digital Weight Indicator Setup / Operation Manual

CHECK WEIGHING SCALE. Operation Manual. Revision 2.7 June Transcell Technology, Inc. Contents subject to change without notice.

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

MODEL TI-700. Digital Weight Indicator (with wireless weighing capability) Installer s Manual

PC-150. DIGITAL BENCH SCALE Setup / Operation Manual

Industrial SBU Product User s Manual

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

MODEL TI-500 SL. User Manual. Digital Weight Indicator

Addendum to TI-500E Plus Setup/Operation Manual For Time, Date, Print Formats Option

Digital Counting Scale. Revision 2.4 October 20, Transcell Technology, Inc. Contents subject to change without notice.

Digital Scale. Operation Manual. Revision 1.1 April 16, Transcell Technology, Inc. Contents subject to change without notice.

Model DS100 Scale Indicator

PS-IN202 Weighing Indicator User Manual

Copyright Western Scale Co. Limited. All rights reserved.

Operating Manual =CENTER OF ZERO =CENTER OF ZERO. FB 2250 Series Instrument by Fairbanks Scales, Inc All rights reserved Rev.

! User Manual Rev. 1

Crane Scale. Revision 1.4 February 18, Transcell Technology, Inc. Contents subject to change without notice.

LTS DR2100A/AN Indicator WARRANTY POLICY

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

Multi-Function Smart Indicator User Manual

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

MODEL. TI-500 RF Series. Installer s Manual. Digital Weight Indicator (with wireless weighing capability)

Sartorius Comparator. Interface Description for the CC Model Series

WARRANTY POLICY. 1 CONTACT INFORMATION. 2 GENERAL INFORMATION. 2 STANDARD FEATURES. 3 INDICATOR OPTIONS. 3 DISPLAY DESCRIPTION. 4 KEYBOARD CONTROLS.

Model PC-400 Portion Control Scale

QuickSilver Series Bench Scale

1. On / Off. 2. Initial reset to zero

BB 8100 SS Operator s Manual & Troubleshooting Guide

EXCELL PRECISION CO., LTD.

Trade Approved Version NMI: S520

TI DIGITAL WEIGHT INDICATOR Setup / Operation Manual

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

SERIES 208 INSTALLATION & OPERATING MANUAL

Copyright Western Scale Co. Limited. All rights reserved.

BW/BWS Weighing Indicator

Model PC-400 Portion Control Scale

DT 200. Data Terminal Operators Manual Version 1.E 03/15/2010 Program S200001x

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

FB1100 Series. Digital Instrument Products: Owner s Manual

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller.

This document hosted by: Extension Load Cell Cable (OP-02)

SY021 Portable Load/Force Meter User instructions

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

GM8895. User s Manual

Gateway 1400 Reference Manual

DIGITAL WEIGHT INDICATOR Setup / Operation Manual

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom

805HP. Handheld Digital Weight Indicator User s Manual (v1703) Anyload Transducer Co. Ltd Website:

Addmaster Corporation

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

QC-3265 Checkweigher User s Manual

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Pennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual

VC500 Series USERS GUIDE P/N

CONFIGURATION: The Reader, LED Indicator, pin numbers for the 9-pin connector and the 25-pin adapter are shown in Figure 1-2.

Model 815 User s Manual

CW INSTRUCTION MANUAL

CAUTIONS... 4 INTRODUCTION...

CHAPTER 1. Introduction Introduction 3

Manual 601: : USB/RS232. Specifications. Contents. Options

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

7561-PSD Manual Portable Battery Powered Indicator

3000 SERIES LOW PROFILE FLOOR SCALE.

TWP series. Weighing Indicator Service Manual

CERTIFICATE of EU TYPE-APPROVAL

Model 7620U. Bench Scale. User s Manual

1203 Weight Transmitter Reference Manual For use with Software Versions 1.0 and above

TWP-W. Weighing Indicator Service Manual

AD Remote Controller INSTRUCTION MANUAL WM+PD A

Force Pressure Temperature Switch Service EZE20X005. Digital amplifier BE 946

IDS 430/433. Weight Indicator Installation/Calibration/Operation. Version 1.B 06/13/08

SURVIVOR CW-80 Checkweigher. Installation Manual

DISCONTINUED SURVIVOR CW-80. Installation Manual. Checkweigher

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

C500 Series Data Sheet

INSTRUCTION MANUAL. Strain Gage Indicator with Enhanced Performance Features. Model ADVANCED FORCE MEASUREMENT

NUWEIGH Large Remote Display KCA 1100 MKII

Interface Technology Group, Inc.

OPERATING MANUAL AND TECHNICAL REFERENCE

Optima OP-902 User Manual

Single-Axis Counter BDD 611

Transcription:

North American Service Manual MODEL PC SERIES Version 2 March 25, 1997 Revision B1.1 April 4, 2000 Prepared by TRANSCELL TECHNOLOGY, INC.

TABLE OF CONTENTS Page Chapter 1: Introduction... 1-1 Chapter 2: Legal for Trade Sealing... 2-1 2.1 Overview... 2-1 2.1.1 Sealing the Scale... 2-1 Chapter 3: General Troubleshooting Flowchart... 3-1 Chapter 4: Illustrated Parts List... 4-1 4.1 PC-30 & PC-70... 4-1 4.2 PC-150... 4-3 Chapter 5: Assembly / Disassembly... 5-1 5.1 PC-30 & PC-70... 5-1 5.2 PC-150... 5-2 Chapter 6: Internal Wiring Diagram... 6-1 Chapter 7: Theory of Operation... 7-1 7.1 Theory of Operation Overview... 7-1 7.1.1 Main Board Assembly... 7-1 7.1.2 Display/Key Board Assembly... 7-1 Appendix A: Technical Specifications... A-1 Appendix B: Serial Data Formats Information... B-1 B.1 Serial Data Formats... B-1 B.1.1 Serial Data Formats Overview... B-1 B.1.2 Consolidated Controls Demand Format... B-1 B.1.2.1 Recognized Host Commands... B-1 B.1.3 Consolidated Controls Continuous Format... B-2 B.1.4 Toledo 8213 Demand Format... B-3 B.1.4.1 Recognized Host Commands... B-3 B.1.5 NCI 3800 / Triner Demand Format... B-4 B.1.5.1 Recognized Host Commands... B-4 B.1.6 Transcell Technology Demand Format... B-5 B.1.6.1 Recognized Host Commands... B-5 B.1.7 Transcell Technology Continuous Format... B-6 B.1.8 Detecto Demand / Continuous Format... B-7 B.1.8.1 Recognized Host Commands... B-7 i

B.1.9 Fairbanks 70-2453-4 Demand Format... B-8 B.1.9.1 Recognized Host Commands... B-8 Appendix C: Circuit Diagrams... C-1 LIST OF FIGURES 1-1 PC Series Front Panel... 1-1 2-1 Location of Calibration Switch... 2-1 2-2 Detail of Calibration Switch... 2-1 5-1 Opening up the PC-30 and PC-70 Base Unit... 5-1 5-2 Opening up the PC-150 Base Unit... 5-3 6-1 PC Series Chassis Wiring Diagram... 6-1 B-1 Consolidated Controls Demand Weigh Data Record... B-1 B-2 Consolidated Controls Continuous Weigh Data / Status Record... B-2 B-3 Toledo 8213 Demand Weigh Data Record... B-3 B-4 Toledo 8213 Demand Status Record... B-3 B-5 NCI 3800 / Triner Demand Weigh Data Record... B-4 B-6 NCI 3800 / Triner Demand Status Record... B-4 B-7 NCI 3800 / Triner Demand Invalid Command Record... B-4 B-8 Transcell Technology Demand Weigh Data Record... B-5 B-9 Transcell Technology Demand Status Record... B-5 B-10 Transcell Technology Continuous Weigh Data / Status Record... B-6 B-11 Detecto Weigh Data / Status Record... B-7 B-12 Fairbanks Demand Weigh Data / Status Record... B-8 ii

CHAPTER 1: INTRODUCTION Service and maintenance personnel who desire more technical information than is presented in the PC Series User s Guide should use this manual. Any component level troubleshooting or board replacement should be done by factory authorized personnel only. The PC Series has three ranges of weight capacities. The PC-30 is a 30 lb (15 kg) scale, the PC-70 is a 70 lb (30 kg) and the PC-150 is a 150 lb (70 kg) scale. GROSS NET TARE ZERO lb kg STABLE CAPACITY: 70 x 0.05 lb, 30 x 0,02 kg CLASS III Temp. Range: 0 to 40 C n max = 1500 lb kg ZERO NET GROSS TARE PRINT Transcell Technology inc. MODEL PC-70 FIGURE 1-1: PC Series Front Panel 1-1

CHAPTER 2: LEGAL FOR TRADE SEALING 2.1 OVERVIEW The scale can be prepared for commercial use by sealing access to the calibration switch, to meet the requirements for a legal-for-trade scale. 2.1.1 SEALING THE SCALE Once calibration has been successfully completed, then the scale can be sealed as follows: 1. Referring to Figure 2-1, locate the calibration switch on the back of the scale. 2. Replace the calibration switch cover by securing with the two drilled head screws. 3. Thread a wire security seal through the openings in both drilled head screws. This prevents access to the calibration switch. Refer to Figure 2-2 for more detail. Calibration Switch Figure 2-1: Location of Calibration Switch Drilled Head Screws Figure 2-2: Detail of Calibration Switch Cover Plate with Drilled Head Screws 2-1

CHAPTER 3: GENERAL TROUBLSHOOTING FLOWCHART START A Does Scale Turn On? YES NO Try The Following In Order Of Appearance: 1. Replace AC Adapter. 2. Check the Display Cable. 3. Troubleshoot or Replace Main PCB. Is the Scale Stable? YES NO Try The Following In Order Of Appearance: 1. Check for proper AC Adapter Voltage. 2. Check environment. 3. Troubleshoot or Replace Main PCB. Does Scale Weigh? YES NO Try The Following In Order Of Appearance: 1.Try re-calibrating scale. 2. Check Load Cell Wiring. 3. Replace Load Cell. 4. Replace Main PCB. Is the Scale Linear? YES NO Try The Following In Order Of Appearance: 1. Check for platform obstruction (i.e. ovld stop). 2. Replace load cell if zero offset count too high. 3. Troubleshoot or Replace Main PCB. Try The Following In Order Of Appearance: Do the Keys Work? YES NO 1. Check Display Cable. 2. Troubleshoot or Replace Display PCB. 3. Troubleshoot or Replace Main PCB. A CALL TRANSCELL STOP 3-1

CHAPTER 4: ILLUSTRATED PARTS LIST 4.1 PC-30 AND PC-70 1 4 2 3 5 4-1

ITEM QTY PART NO. DESCRIPTION 1 1 380190008 Stainless Steel Platform 2 1 211040020 Load Cell FAD-20 (PC-30) 2 1 211040045 Load Cell FAD-45 (PC-70) 3 1 380190036 Bottom Spacer - Aluminum 4 1 380190037 Top Spacer - Aluminum 5 4 380190013 Adjustable Foot 1 250116237 AC Adapter 12 VDC, 500 ma 1 ITEM QTY PART NO. DESCRIPTION 1 1 215193811 Main Board Assy 1 215366100 Display/Key Board Assy 4-2

4.2 PC-150 1 3 5 6 7 4-3

ITEM QTY PART NO. DESCRIPTION 1 1 380190008 Stainless Steel Platform 3 1 380360001 Top Spacer - Aluminum 5 1 211040100 Load Cell FAD-100 6 1 380360007 Bottom Spacer - Aluminum 7 4 380190013 Adjustable Foot 1 250116237 AC Adapter 12 VDC, 500 ma 4-4

CHAPTER 5: ASSEMBLY / DISASSEMBLY 5.1 PC-30 and PC-70 Tools Required: 5 mm Allen Wrench Phillips Head Screwdriver 1. Remove the scale platter (1) and set aside. 2. Using the 5 mm Allen wrench, remove the [2] load cell mounting bolts (2). 3. Lift off the sub-platform assembly (3), and set aside. 4. Remove the [4] mounting screws (5) for the splash plate (4) and set aside. 5. Lift off the splash plate and set aside. 1 2 3 4 5 Figure 5-1: Opening up the PC-30 and PC-70 Base Unit 5-1

5.2 PC-150 Tools Required: 5 mm Allen Wrench Phillips Head Screwdriver 1. Remove the scale platter (1) and set aside. 2. Using the 5 mm Allen wrench, remove the [2] load cell mounting bolts (2). 3. Lift off the sub-platform assembly and aluminum spacer (3), and set aside. 4. Remove the [4] mounting screws (5) for the splash plate (4) and set aside. 5. Lift off the splash plate and set aside. 5-2

1 2 3 5 4 Figure 5-2: Opening up the PC-150 Base Unit 5-3

CHAPTER 6: INTERNAL WIRING DIAGRAM Load Cell RED GRN BLK WHT Main / ADC Board Assy RED GRN BLK WHT J8 1 2 3 4 J1 2 E+ S+ E S + J2 BLK RED JP2 Setup Switch 1 Ferrite Bead Core 1 2 3 4 5 6 7 8 9 10 J3 1 2 3 4 Female DSUB9 RED 5 2 3 GND SCALE RXD SCALE TXD + Ferrite Bead Core DC Power Jack 1 2 LED + On/Off Switch Display/Key Board Assy (PC-150 only) 10 9 8 7 6 5 4 3 2 1 TO REMOTE DISPLAY/ KEY UNIT (PC-30 & PC-70 ONLY) Female 14-PIN CENTRONICS Figure 6-1: PC Series Chassis Wiring Diagram 6-1

CHAPTER 7: THEORY OF OPERATION 7.1 THEORY OF OPERATION OVERVIEW Refer to Appendix C for reference designators. 7.1.1 MAIN / ADC BOARD ASSEMBLY Power to the scale is supplied by a 12 VDC, 500 ma adapter. Regulator U1 supplies +5 VDC to the digital components. Regulator U8 supplies + 10 VDC to the analog components including load cell excitation. Switching regulator V5 inverts the + 10 VDC to 10 VDC to act as the negative supply rail. Regulators V4 and V6 further regulate to ± 8 VDC for the A/D converter IC, U9. Op-amp U11 forms a high impedance bridge amplifier for the load cell with a fixed gain of 100. Op-amp U10:B forms a low pass filter to prevent unwanted noise from entering the circuit. The other half of U10 (U10:A) provides a buffered reference voltage for op-amp U11. The A/D converter, U1, is a dual slope type converter. Timing is controlled by the microcontroller. Microcontroller U2 executes several functions including A/D fetch, digital signal conditioning, key scan, serial communication, and display output. EEPROM U5 contains calibration data as well as the setup parameters. IC U7 is the EPROM, which contains program memory. The network around U4 boosts the MCU s UART signal to RS-232 level for serial communication with a host device. 7.1.2 DISPLAY/KEY BOARD ASSEMBLY This circuit contains footprints for 5 keys, display driver (U4) and the LED Display (U1-U3). 7-1

APPENDIX A: TECHNICAL SPECIFICATIONS ANALOG SPECIFICATIONS Full Scale Input Signal Internal Resolution Displayed Resolution Measurement Rate System Linearity Calibration Method Excitation Voltage RFI Protection DIGITAL SPECIFICATIONS Microcontroller SERIAL COMMUNICATIONS RS-232 OPERATOR INTERFACE Display Keyboard POWER AC Adapter ENVIRONMENTAL 16 mv, including dead load Approximately 150,000 counts Up to 3,500 graduations max 10 Meas/sec, nominal Within 0.02% of FS Software Calibration, with long term storage in EEPROM +10 VDC Signal lines protected by LC Low Pass Filters Excitation & Power lines protected by EMI Chokes Intel 80C32 Program Memory: 32K x 8, external to µc EEPROM: 64 x 16, external to µc Full Duplex, Selectable Baud, Data Bits and Parity 6-Digit, 0.56 7-segment LED Display 5-key Tactile Keypad 12 VDC, 500mA Operating Temperature 41 F (0 C) to 95 F (40 C) Storage Temperature -4 F (-20 C) to 167 F (+75 C) Operating RH 20% to 95%, non-condensing Storage RH 20% to 98% PHYSICAL DIMENSIONS: 13.0 in [330.2 mm] 13.0 in [330.2 mm] 4.4 in [112 mm] ON/OFF SWITCH DC POWER JACK CALIBRATION SWITCH COVER ID TAG RS-232 PORT REMOTE DISPLAY CONNECTOR (WP-30 & 70 ONLY) PC-150 Only 10.2 in [258.0 mm] PC-30/70 A-1

APPENDIX B: SERIAL DATA FORMATS INFORMATION B.1 SERIAL DATA FORMATS B.1.1 SERIAL DATA FORMATS OVERVIEW The COM1 serial port is a full duplex RS-232 port designed for connection to a serial printer, computer, or remote display. Consult the PC Series Operation Manual for information on pinouts and cable diagrams. Through the User Menu, you may choose one of the available SDF s (Serial Data Formats). These serial data formats emulate certain makes of scales and make up the Application Layer. From a Data Link Layer perspective, there are two types: Demand and Continuous. Some SDF s can be used with both types but most can be used with only one type. For Demand types, the scale acts as the client and requires a host (usually a PC). The host issues a command (typically a single ASCII character) and the scale responds with a weigh data record, a status record or no record depending on the specific SDF chosen. NOTE: Use Demand types for interfacing to a serial printer. In this case, data output can be initiated by pressing the PRINT key on the front panel of the scale. (Host is not required). For Continuous types, host control is not required but not restricted either. In this type, the scale automatically transmits a weigh data / status record out of the serial port at the end of each display update. Continuous types are used to interface to computers, scoreboards, and other remote devices requiring constant data updating. Host commands, although not required, are accepted and acted upon. B.1.2 CONSOLIDATED CONTROLS DEMAND FORMAT Figure B-1 shows the weigh data record sent to the host when the scale receives a Print ( P ) command. The same weigh data record is sent out of the serial port if the PRINT key is pressed on the scale s front panel. If the weigh data is invalid, the scale does not respond. See section below for more information. <STX> <POL> xxxxx.xx <SP> <LB/KG> <SP> <GR/NT> <CR> <LF> Start Weight Data Space Space Carriage Return Polarity: <SP> = Positive " " = Negative Units: lb = pound kg = kilogram Gross/Net: GR = Gross NT = Net Line Feed FIGURE B-1. Consolidated Controls Demand Weigh Data Record B.1.2.1 RECOGNIZED HOST COMMANDS These commands are issued from the host to the scale and are single ASCII characters. P - This command is sent to the scale to print the indicated display. The scale will not respond if the scale is in motion, positive overload or negative overload. Page B-1

Z - This command is sent to the scale to zero the scale. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in gross mode or within the zero reset range. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. T - This command is sent to the scale to tare the scale. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it displaying a negative gross value. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. G - This command is sent to the scale to revert to gross mode. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in net mode. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. N - This command is sent to the scale to revert to net. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in gross mode or a tare has yet to be established. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. C - This command is sent to the scale to toggle among the configured units. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. B.1.3 CONSOLIDATED CONTROLS CONTINUOUS FORMAT Figure B-2 shows the weigh data / status record automatically transmitted by the scale at the end of each display update. The same host commands listed in Section B.1.2.1 are accepted and acted upon by the scale. <STX> <POL> xxxxx.xx <L/K> <G/N> <STAT> <CR> <LF> Start Polarity: <SP> = Positive " " = Negative Weight Data Units: L = pound K = kilogram Gross/Net: G = Gross N = Net Carriage Return Line Feed Status: <SP> = Valid M = Motion O = Over/under range FIGURE B-2. Consolidated Controls Continuous Weigh Data / Status Record Page B-2

B.1.4 TOLEDO 8213 DEMAND FORMAT Figure B-3 shows the weigh data record sent to the host when the scale receives a Print ( W ) command. The same weigh data record is sent out of the serial port if the PRINT key is pressed on the scale s front panel. If the weigh data is invalid, the scale responds with a status record instead as shown in Figure B-4. See section below for more information. NOTE: Since this SDF (Serial Data Format) does not support units of measure. It is recommended that lb/kg conversion be disabled. <STX> XXX.XX <CR> Start Weight Data Carriage Return FIGURE B-3. Toledo 8213 Demand Weigh Data Record <STX> <?> <SS> <CR> Start Invalid Weight Carriage Return Status Byte: ( "1" = "True") See Table Bit B7 B6 B5 B4 B3 B2 B1 B0 STATUS BYTE TABLE Function Parity bit Always "1" Always "1" Center of zero Outside zero capture range Under zero Out of range Motion FIGURE B-4. Toledo 8213 Demand Status Record B.1.4.1 RECOGNIZED HOST COMMANDS These commands are issued from the host to the scale and are single ASCII characters. W - This command is sent to the scale to print the indicated display. The scale will respond with the status record if the weight is less than zero or the scale is in motion, positive overload or negative overload. Otherwise, the scale responds with the weigh data record. H Same as the W command except that the scale outputs an extra character at the beginning and end of the weigh data record. Z - This command is sent to the scale to zero the scale. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in gross mode or within the zero reset range. Whether the command was successful or not, the scale sends a status record to the host. Page B-3

A - This command is sent to the scale to request an acknowledgement. This acknowledgement consists of two characters: <STX> and <CR>. B.1.5 NCI 3800 / TRINER DEMAND FORMAT Figure B-5 shows the weigh data record sent to the host when the scale receives a Print ( W <CR>) command. The same weigh data record is sent out of the serial port if the PRINT key is pressed on the scale s front panel. The status record is shown in Figure B-6. If an invalid host command is received, the scale responds with the invalid command record shown in Figure B-7. See section below for more information. <LF> (1) <xx.xxx> (2) <LB/KG> <CR> (4) <HSB> Line Feed Weight Data (1) Insert <SP> for Triner. (2) Insert <SP> for NCI. (3) Use lower case for NCI. (4) Insert <LF> for NCI. Units (3): LB = pound KG = kilogram Carriage Return High Status Byte: See Table Low Status Byte: See Table <LSB> <ETX> End of Bit B3 B2 B1 B0 High Status Byte Table ("1" = "True") Bit B3 B2 B1 B0 Function Not Used Not Used Not at zero Motion Low Status Byte Table ("1" = "True") Function Not Used Not Used Over capacity Under capacity FIGURE B-5. NCI 3800 / Triner Demand Weigh Data Record <LF> S <HSB> <LSB> <CR> <ETX> <LF>? <CR> Line Feed High Status Byte: Same as "W" Carriage Return Low Status Byte: See as "W" End of Line Feed Carriage Return FIGURE B-6. NCI 3800 / Triner Demand Status Record FIGURE B-7. NCI 3800 / Triner Demand Invalid Command Record B.1.5.1 RECOGNIZED HOST COMMANDS These commands are issued from the host to the scale and consist of two ASCII characters. W <CR> - This command is sent to the scale to print the indicated display. The host should check the status bytes to determine if the scale is in motion, positive overload or negative overload. Page B-4

Z <CR> - This command is sent to the scale to zero the scale. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in gross mode or within the zero reset range. Even if successful, the host receives no response from the scale. The host must issue an S <CR> command to determine if the command was processed by the scale. S <CR> - This command is sent to the scale to request the status record. B.1.6 TRANSCELL TECHNOLOGY DEMAND FORMAT Figure B-8 shows the weigh data record sent to the host when the scale receives a Print ( P ) command. The same weigh data record is sent out of the serial port if the PRINT key is pressed on the scale s front panel. If the weigh data is invalid, the scale sends the status record shown in Figure B-9. See section below for more information. <STX> <+/ > XXXX.XXX <SP> <UNITS> <SP> <GR/NT> <CR> <LF> <ETX> Start Weight digits* Space Space Carriage Return End Polarity: + = Positive = Negative Units: lb = pound kg = kilogram Gross/Net: GR = Gross NT = Net Line Feed * with leading zero suppression FIGURE B-8. Transcell Technology Demand Weigh Data Record <STX>? <S1> <S2> <ETX> Question Mark End Start Status Character 2: See Continuous Mode Status Character 1: See Continuous Mode FIGURE B-9. Transcell Technology Demand Status Record B.1.6.1 RECOGNIZED HOST COMMANDS These commands are issued from the host to the scale and are single ASCII characters. P - This command is sent to the scale to print the indicated display. The scale will respond with the status record instead if the scale is in motion, positive overload or negative overload. Page B-5

Z - This command is sent to the scale to zero the scale. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in gross mode or within the zero reset range. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. T - This command is sent to the scale to tare the scale. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it displaying a negative gross value. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. G - This command is sent to the scale to revert to gross mode. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in net mode. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. N - This command is sent to the scale to revert to net. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in gross mode or a tare has yet to be established. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. C - This command is sent to the scale to toggle among the configured units. Even if successful, the host receives no response from the scale. The host must issue a P command to determine if the command was processed by the scale. B.1.7 TRANSCELL TECHNOLOGY CONTINUOUS FORMAT Figure B-10 shows the weigh data / status record automatically transmitted by the scale at the end of each display update. The same host commands listed in Section B.1.6.1 are accepted and acted upon by the scale. <STX> <LF> <+/ > XXXX.XXX <UNITS> <G/N> <LF> <S1> <S2> <ETX> Line Feed Start Polarity: + = Positive = Negative Weight Data Units: LB = pounds KG = kilograms Gross/Net: G = Gross N = Net Line Feed End Status Character 2: 0 = valid 1 = Motion 2 = Zero 3 = Motion and Zero 4 = Not Ready Page B-6 Status Character 1: 0 = valid 1 = Under 2 = Over FIGURE B-10. Transcell Technology Continuous Weigh Data / Status Record

B.1.8 DETECTO DEMAND / CONTINUOUS FORMAT The Detecto SDF (Serial Data Format) can work both as a Demand type and a Continuous type, depending on the commands received from the host. Upon power up, the scale defaults to Demand type. The scale disregards the type setting programmed for Mode of Serial. Figure B-11 shows the weigh data / status record sent to the host when the scale receives a Print ( ~ ) command. The same weigh data record is sent out of the serial port if the PRINT key is pressed on the scale s front panel. The output records are identical when operating as a Demand type or a Continuous type. NOTE: Since this SDF (Serial Data Format) does not support units of measure. It is recommended that lb/kg conversion be disabled. <STX> <POL> XXX <SP> LB <SP> XX.X OZ <SP> <SB> <CHK1> <CHK2> <ETX> Start Polarity: <SP> = Positive = Negative Space Weight digits* Space Weight digits* Space Checksum Byte 1 Status Byte: M = Motion C = Over Checksum Byte 2 End * with leading zero suppression FIGURE B-11. Detecto Weigh Data / Status Record B.1.8.1 RECOGNIZED HOST COMMANDS These commands are issued from the host to the scale and are single ASCII characters. ~ - This command is sent to the scale to print the indicated display. The host should check the status bytes to determine if the scale is in motion, positive overload or negative overload. <SO> - This command is sent to the scale to change the scale to Continuous type. Even if successful, the host receives no response from the scale. <SI> - This command is sent to the scale to change the scale to Demand type. Even if successful, the host receives no response from the scale. NOTE: You can execute the <SO> and <SI> host commands by hitting Ctrl-N for <SO> and Ctrl-O for <SI> on your computer s keyboard. Page B-7

B.1.9 FAIRBANKS 70-2453-4 DEMAND FORMAT Figure B-12 shows the weigh data / status record sent to the host when the scale receives a Print (<CR>) command. The same weigh data record is sent out of the serial port if the PRINT key is pressed on the scale s front panel. XXXX.XXX <SP> <UNITS> <SP> <GR/NT> <SP> <SP> <CR> <LF> <EOT> Weight digits* Space Space Units: lb = pounds kg = kilograms Space Two Status Bytes: GR = gross/stable gr = gross/unstable NT = net/stable nt = net/unstable Space Carriage Return Carriage Return End * with leading zero suppression FIGURE B-12. Fairbanks Demand Weigh Data / Status Record B.1.9.1 RECOGNIZED HOST COMMANDS These commands are issued from the host to the scale and are single ASCII characters. <CR> - This command is sent to the scale to print the indicated display. The scale will not respond if the scale is in positive overload. The host should check the status bytes to determine if the scale is in motion. Z - This command is sent to the scale to zero the scale. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in gross mode or within the zero reset range. Even if successful, the host receives no response from the scale. The host must issue a <CR> command to determine if the command was processed by the scale. T - This command is sent to the scale to tare the scale. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it displaying a negative gross value. Even if successful, the host receives no response from the scale. The host must issue a <CR> command to determine if the command was processed by the scale. G - This command is sent to the scale to revert to gross mode. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in net mode. Even if successful, the host receives no response from the scale. The host must issue a <CR> command to determine if the command was processed by the scale. N - This command is sent to the scale to revert to net. The scale will disregard this command if the scale is in motion, positive overload or negative overload. The scale will also disregard this command if it is not in gross mode or a tare has yet to be established. Even if successful, the host receives no response from the scale. The host must issue a <CR> command to determine if the command was processed by the scale. Page B-8

C - This command is sent to the scale to toggle among the configured units. Even if successful, the host receives no response from the scale. The host must issue a <CR> command to determine if the command was processed by the scale. Page B-9

APPENDIX C: CIRCUIT DIAGRAMS Please see attached schematic diagram sheets. C-1