The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Similar documents
The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The LT1320 also has analog out circuitry to generate a precision 0/4-20mA or 0-10V analog output signal.

DXP-40 FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Weight Indicator. Model Intuition 22i FEATURES APPLICATIONS DESCRIPTION OPTIONS CONFIGURATION

High Voltage DC Meter

LAUREL ELECTRONICS, INC.

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

HIGH-VOLTAGE DC METER

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

LC0 DVP

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

PD Helios Strain Gauge, Load Cell & mv Meter. Strain gauge. Actual Size Digit

Trident and Trident X2 Digital Process and Temperature Panel Meter

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

System StrainSmart Data Acquisition System. Micro-Measurements FEATURES DESCRIPTION MODEL 5100B SCANNER SPECIFICATIONS

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Simplified information where and how you want it.

The GF-2 is able to measure G-forces even if the instrument is not mounted exactly on the vertical axis of the aircraft.

PD765 TRIDENT. Trident Series Process & Temperature Meters.

IPM650 Intelligent Panel-Mount Display

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

GF-1. Introduction. 1 Features. +-10G Tilt Compensated dual range aviation G-force meter. Operating Manual English 1.00

Safe-Weigh Process Weighing System

LCt-104 FEATURES HTU MODE FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

DUAL-LINE TEMPERATURE METER

OZONE SWITCH Model OS-6. OS-6 Features

PD765 TRIDENT. Trident Series Process & Temperature Meters.

General Specifications. P2-08THM Analog Input

dual-line 6-dIGIt process MeteR

CHAPTER 1. Introduction Introduction 3

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath

PD Helios Dual-Line 6-Digit Temperature Meter. Actual Size Digit

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

ES-600 Ozone Controller Operation Manual

LCI User Manual mantracourt.com

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LAUREL ELECTRONICS, INC.

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Tempco Instruction Manual

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

FLOW MONITOR & TRANSMITTER

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

Simplified information where and how you want it.

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

FLS M9.06. ph/orp MONITOR

Multi-Point Gas Detection and Control System

Samba PLC+HMI SM35-J-RA22

P2-04AD Analog Input. Removable Terminal Block Specifications

MOD-RI Room Interface Modules with Modbus

The CAL range of temperature controllers

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Characteristics and functioning

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

Process displays For current and voltage

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

NF760 Batch Controller

Product Description. Contents. Fusion Series. New Information December 2003

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES.

Multi-Point Gas Detection and Control System

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

Universal power supply

ProVU 4 Advanced Temperature & Process Controller

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

C500 Series Data Sheet

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

LLR-MOD Modbus Light Level and Occupancy Sensor

Micro Motion Model 7950 and Model 7951 Signal Converters

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

P2-04DA Analog Output. Removable Terminal Block Specifications

Multi-Point Gas Detection and Control System

7561-PSD Manual Portable Battery Powered Indicator

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

TLB4 TLM8. ERDE-Elektronik AB - Spikgatan Vellinge TLM8den.

Transcription:

IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high bright 6-digit 7-segment 20mm LED displays and the sunlight readable graphic LCD display make for easy setup and readability. A simple menu system allows for easy configuration of display and load cell settings. The load cell calibration can be done directly from the load cell calibration certificate or from using known weights. A universal mains switch mode power supply (85-264VAC) is provided as standard but an optional low voltage (10-30VDC) isolated power supply or a high voltage (25-70VDC) isolated power supply can be installed. The IQ300 contains precision front end circuitry for high accuracy and stability. The load cell bridge excitation voltage can be field selectable for 5VDC or 10VDC and provides for a Kelvin sensed feedback to compensate for cable loss. The IQ300 can power up to 6x350Ω load cells at 10V excitation and can interface to both 4-wire and 6-wire load cells. RS232 and RS485 communications is supplied as standard with the MODBUS RTU and MODBUS ASCII protocol. A simple ASCII out protocol is also provided for serial printing and communicating to large displays. The IQ300 also has analog out circuitry to generate a precision 0/4-20mA, 0-10V or +-10V analog output signal. The IQ300 also includes advanced features such as auto-zero tracking, user input linearisation, max/min recording, programmable front push buttons, programmable digital inputs, security menu lockout, zero indication, motion indication, advanced digital filtering, plus many more to provide a all in one precision load cell indicator.

IQ300 Wall Mount Load Cell Indicator Page 2 1 Features 4 or 6 wire load cell / strain gauge input Field jumper selectable 5V or 10V load cell / bridge excitation voltage (Kelvin force sense excitation voltage to compensate for cable loss) Can power up to 6x350Ω load cells at 10V excitation voltage High precision 22bit ADC front end circuitry -199999 to +999999 display counts High bright 6-digit 7-segment 20mm LED displays 128x64 pixel backlit sunlight readable graphic LCD display for easy setup and calibration Easy calibration either from the load cell calibration certificate or by using known weights RS232 and RS485 communications (MODBUS RTU/ASCII and a serial ASCII out protocol) 180x180x60mm flame retardant ABS enclosure Universal mains switch mode power supply (85-264VAC) standard with built in EMI and fuse protection 4x Mechanical (FORM-C) relays 3x Programmable digital inputs 16 Point lineariser High precision 16bit Analog output (0/4-20mA, 0-10V, +-10V) Auto-zero tracking function Selectable/adjustable advanced digital filtering Up to 8 front panel LED indicators for alarm set point status, print, net/gross toggle, motion and zero Full alpha-numeric keypad Front programmable function keys (Zero, Tare, Print, Gross/Net toggle, LED Display Toggle, Display Hold & Alarm latch reset Max/Min weight recording RTC (Real Time Clock) for time and date stamping Cage clamp wire connectors for easy installation Field upgradable firmware via the RS232 interface 1 Year Warranty Additional hardware options include: Up to 4 solid state (FORM-A) relays Low voltage 10-30VDC Isolated power supply High voltage 25-70VDC Isolated power supply

IQ300 Wall Mount Load Cell Indicator Page 3 2 Specifications General: LED Display 6-Digit, 20mm (0.8 ) 7 segment high brightness red LED LCD Display 128x64 Full graphic sunlight readable monochrome display LCD Backlight Yellow/Green, User defined on/off control Display range -199999 to +999999 Display decimal point 0 to 0.00000 Status LEDS 8 LEDs total (SP1, SP2, SP3, SP4, Zero, Net, Motion & Print) Digital Inputs 3 Programmable digital inputs Built in hysteresis, filter and input over voltage protection Maximum input voltage <30VDC (Pull up, sinking inputs) - 10kΩ internal resistor to +5V Active/Non-Active input trigger: <1.9V Non-Active/Active input trigger: >2.3V Keypad Full 4x3 alpha-numeric keyboard 4 Dedicated function keys (Zero, Tare, Print, Gross/Net toggle) 3 Dual function keys (Display Toggle, Display Hold & Alarm latch reset) Memory storage Non-volatile EEPROM, 100000 write cycles minimum Warm up time 15 minutes Power Requirements: AC Power Supply DC Power Supply, 10-30VDC (Optional) DC Power Supply, 20-70VDC (Optional) 85-264VAC, 50/60Hz or 120-370VDC Isolation: 3000VAC/1min 10-30VDC input Reverse and over voltage protected Isolation: >1000V/1min 25-70VDC input Reverse and over voltage protected Isolation: >1000V/1min Power Consumption <15W Fuse (Built in) 2A Slow Blow (Wickmann 3721200000) RS components part number 226-6599 Environmental: Operating temperature Storage temperature Operating and storage humidity -10 C to 50 C (14 F to 122 F) -40 C to 80 C (-40 F to 176 F) <85% RH non-condensing Enclosure: Overall Dimensions 180x180x60mm (LxHxD) (7.09x7.09x2.36 ) (Height includes cable glands) Mounting Holes 159x94mm (6.26x3.7 ) Enclosure Material ABS Flame Retardant (UL 94 V-0) IP Rating IP65 / NEMA 4 / UL Type 4 Connector Ratings: (Cage clamp wire connectors) Conductor cross section solid min 0.2mm2 Conductor cross section solid max 2.5mm2 Conductor cross section stranded min 0.2mm2 Conductor cross section stranded max 1.5mm2 Conductor cross section solid min with 0.25mm2 ferrule Conductor cross section solid max with 1.5mm2 ferrule Wire stripping length 7.5mm

IQ300 Wall Mount Load Cell Indicator Page 4 Gland Ratings: Clamping/sealing range (Small gland) Clamping/sealing range (Large gland) 4-8mm (0.157-0.314 ) Diameter wire 7-13mm (0.276-0.512 ) Diameter wire Input: ADC Resolution 22 bit Delta-sigma Input range -20mV to +35mV Conversion rate 12 updates/second Filter Moving average digital filter with programmable input step detection Increment size 1, 2, 5, 10, 20, 50, 100, 200 Input Impedance 20 MΩ CMRR >-110dB Linearity <0.01% of full scale Accuracy 0.05% of full scale Calibration method From the load cell calibration certificate or from using known weights Load cell connection 4 or 6 wire connection + shield (Sense included) Load Cell Excitation: Excitation Voltage (Sense included) Excitation current Cable compensation Cable compensation resistance Analog Out: Ranges (Selectable through menu) DAC Resolution Update rate Current output compliance (maximum load) Voltage output compliance (minimum load) Current open loop detection Linearity Accuracy Field jumper selectable 5V or 10V Bipolar output (+-2.5V or +-5V), referenced to common Max. 172mA Up to 6x350Ω load cells or 10x1000Ω load cells 4 wire Kelvin force sense feedback <= 10Ω 0-20mA 4-20mA 0-10V +-10V 16 Bit 12 updates/second 500Ω (Current is source, not sink) 1kΩ LCD display flashes Loop Error error message <0.02% of full scale 0.05% of full scale Communications: Protocol MODBUS RTU MODBUS ASCII ASCII In (Infiniteq Protocol) ASCII Out (Infiniteq Protocol) RS232 Communications Baud rate: 1200,2400,4800,9600,19200,38400,57600,115200 Data bits: 7 or 8 bits Parity: Odd, Even or None Stop bits: 1 or 2 stop bits Non isolated RS485 Communications Baud rate: 1200,2400,4800,9600,19200,38400,57600,115200 Data bits: 7 or 8 bits Parity: Odd, Even or None Stop bits: 1 or 2 stop bits Internal 120Ω field jumper selectable termination resistor Max 32 instruments per line

IQ300 Wall Mount Load Cell Indicator Page 5 SetPoints: Electro-mechanical Relays: Contact rating 2A@240VAC or 30VDC (Resistive load) Isolation to input circuitry >1000Vrms for 1 minute Type FORM-C (Change over contact (NO/NC)) Life expectancy >100K cycles min. at full load rating. External RC snubber extends relay life for operation with inductive loads Solid-State Relays (SSR): (Optional, Up to 4 can be fitted) Contact rating 120mA@400VAC/DC Isolation to input circuitry >1000Vrms for 1 minute Type FORM-A (Normally open) RTC (Real Time Clock): Battery Accuracy CR2032 Better then 3 seconds per day (Temperature dependent)

IQ300 Wall Mount Load Cell Indicator Page 6 3 Installation Enclosure Dimensions

IQ300 Wall Mount Load Cell Indicator Hardware Connections, Jumpers and Fuse position Below is an exploded view of the hardware connections and jumper locations of the main circuit board. Page 7

IQ300 Wall Mount Load Cell Indicator Page 8 4 Front Panel Layout 6-Digit 7-segment high brightness LED display Zero (Center Zero) Indication Gross / Net Indication Print indication Alarm Status Indication 128x64 Sunlight readable backlit graphic LCD display Motion Indication LCD display page selection keys LCD display page indication Manual Zero key Left key. Tare key Right key. LED Status Indicators Print key. Down key. Gross/Net Toggle key. Up key, +- toggle. Alarm latch reset key Clear / Back key in programming mode LED Display toggle Display Hold key Press and hold for 3 seconds to access the menu system. Enter Key The SP1 to SP4 LED will illuminate when the corresponding alarm has been activated. The Zero (Center Zero) LED will illuminate when the gross weight is within 0.25 counts. The Net LED will illuminate when the LED display is showing the Net weight. The display value must remain within the motion band for 1 second in order for the motion LED to illuminate.

IQ300 Wall Mount Load Cell Indicator Page 9 5 Notice Specifications of the products displayed herein are subject to change without notice. Infiniteq cc, or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies. Information contained herein is intended to provide a product description only. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Infiniteq's terms and conditions of sale for such products, Infiniteq assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of Infiniteq products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Infiniteq for any damages resulting from such improper use or sale. 6 Warranty This product carries a warranty for a period of one year from date of purchase against faulty workmanship or defective materials, provided there is no evidence that the unit has been mishandled or misused. Warranty is limited to the replacement of faulty components and includes the cost of labor. Shipping costs are for the account of the purchaser. Note: Product warranty excludes damages caused by unprotected, unsuitable or incorrectly wired electrical supplies and or sensors, and damage caused by inductive loads.