VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Similar documents
VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Valueline Industrial PC

Industrial PC - VL BPC

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

PHOENIX CONTACT - 05/2007

FL MC 2000E (SM40) LC

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

PHOENIX CONTACT - 07/2006

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Junos WebApp Secure 5.0 Hardware Guide

PHOENIX CONTACT Features

MINI-PS AC/10-15DC/8

PHOENIX CONTACT - 10/2009

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

Characteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

onlinecomponents.com

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

PHOENIX CONTACT - 04/2008

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

TRIO-DIODE/12-24DC/2X10/1X20

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

QUINT-BUFFER/24DC/24DC/40

Compact, fanless, vibration-proof computers for rolling stock applications. Features and Benefits. Certifications

QUINT-PS-3x AC/24DC/10

Industrial PC IPC191V3 (Linux OS) IPC191V3WIN (Windows OS) General Operating, Maintenance and Installation Manual

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

Features and Benefits. Certifications

Features and Benefits. Certifications

TF501, TF521 Terminal Bases

Features and Benefits. Certifications

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

FPC 08W Series. 8 Widescreen Multi-functional Touch Panel PC. Quick Reference Guide. 2 nd Ed 28 June, 2010

8806 Series. 15 Multi-functional Touch Panel PC. Quick Reference Guide

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

HMIBMUSI29D2801 Modular Box PC HMIBM Universal SSD DC Windows 10 2 slots

This data sheet is only valid in association with the IL SYS INST UM E user manual.

TM221CE40R controller M IO relay Ethernet

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Industrial Ethernet Switch

Feature and Benefits. Certifications

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

TM221CE40T controller M IO transistor PNP Ethernet

HMIBMUCI29D2W01 Modular Box PC HMIBM Universal CFast DC WES 2 slots

MINI MCR-SL-CVS NC

Features and Benefits. Certifications

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

HMIBMPHI74D4801 Modular Box PC HMIBM Performance HDD DC Windows 10 4 slots

TM221CE24R controller M IO relay Ethernet

Features and Benefits. Certifications

TM3AI4 module TM3-4 analog inputs

FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

LPC-08 Series. Quick Reference Guide. 8 Multi-functional Touch Panel PC. Copyright Notice. 2 nd Ed May 2010

TM3TI4 module TM3-4 inputs temperature

TM3TM3 module TM3-2 temperature inputs and 1 analog output

PHOENIX CONTACT - 11/2008

TM221M16R controller M IO relay

TU531, TU532 Terminal Unit

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

HEC. General Operating, Maintenance and Installation Manual

ETD-BL-1T-OFF-CC- 10S

iologik E1200H Series

PHOENIX CONTACT - 01/2007

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

CPCI-PS24 24V-Power Supply

PSI-MODEM-SHDSL/SERIAL

TM221ME32TK controller M IO transistor PNP Ethernet

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Product Datasheet. Touch screen Part number OPERATOR INTERFACE

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

General Operating, Maintenance and Installation Manual

F1000 User's Manual. (Version: V1.01)

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

TM221CE24T controller M IO transistor PNP Ethernet

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

DX561 Digital Input/Output Module

TM3TI4 module TM3-4 inputs temperature

TM3TI8T module TM3-8 inputs temperature

DC562, digital input/output module,

FLEX Ex Spring Clamp Terminal Base

DI561 Digital Input Module

TM221ME16T controller M IO transistor PNP Ethernet

TM3DI16 module TM3-16 inputs

TM241C40U controller M IO transistor NPN

DC561, digital input/output module,

EPC-APL. Quick Reference Guide. Intel Pentium /Celeron Processor Fanless Tiny System. Copyright Notice. 1 st Ed 12 September 2017

TM241C24T controller M IO transistor PNP

Transcription:

A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers. It employs a fanless design inside an extremely compact form factor and is DIN rail-mountable. Specially selected, energy-efficient Intel Atom processors allow the VL BPC MINI product to be used in a wide variety of applications. Along with other Valueline IPC products, it is configurable to meet the specific needs of a particular application. Energy-efficient Intel Atom processors Fanless design Customer configurable for specific applications DIN rail and wall mounting options CompactFlash slot for industrial cards Embedded operating system support Wide temperature options for extreme environments High shock and vibration ratings for applications in rugged conditions On-board digital I/O (optional with some processor selections) Secure Digital (SD) card slot NOTE: Protective earth ground and circuit ground (return) are connected. Make sure you always use the latest documentation. It can be downloaded at phoenixcontact.net/products. This data sheet is valid for all products listed on the following page:

Ordering data Products Description Type Order No. Pcs./Pkt. Industrial embedded PC, configurable VL BPC MINI 70077 An order key must be appended to the 7-digit order number to reflect the various options that are specified in each configuration. The order key is generated using the Phoenix Contact on-line configuration tool. Order Key 70077/Axx/Ixx/Rxx/Mxx/OSxx/Sxx/MPxx Order No. Mounting Processor Main memory Mini-PCI option Software Operating system Data storage Accessories Description Type Order No. Pcs./Pkt. Adapter, DIN rail UTA 07/0 0089 Replacement parts Description Type Order No. Pcs./Pkt. Connector, printed circuit board, for power input MSTB,/ -STF 788 0 Connector, printed circuit board, for I/O connection MC,/ 8-STF-,8 877 0 Technical data General Data Dimensions (width x height x depth) x x 9 mm Ambient temperature (operating) -0 C Ambient temperature (storage/transport) -0 8 C Permissible humidity (relative) 9%, non-condensing Weight. kg Degree of protection IP0 Mounting Wall, NS DIN rail (EN 07) LED indicators Power, CF, Run, Error 90_en_F PHOENIX CONTACT

Electrical data Power supply, nominal V DC Power supply, range 9 V DC Power consumption, typical (0% load) 0. W (9 V). W ( V). W ( V) Power consumption, maximum (00% load). W (9 V). W ( V) 0. W ( V) Recommended power supply size. A or greater Type of connection Removable Combicon screw-type Conductor size 0.. mm² ( AWG) Torque 0. 0. Nm RTC battery, typical life years Windows XP Embedded OS, GB RAM, GB CF, x COM loopback, x LAN loopback, keyboard and mouse in USB Windows XP Embedded OS, GB RAM, GB CF, x COM loopback, x USB loopback, keyboard and mouse in USB, x. W loads, x DIO output @ 00 ma each Computer data Operating system (configurable option) Windows Embedded Standard 009 Windows Embedded CE.0 Windows Embedded Standard 7 Processor (configurable option). GHz Intel Atom Z0PT processor RAM (configurable option) GB GB DDR SODIMM (wide temperature) Data storage (configurable option) CompactFlash (bootable) Secure Digital (SD) card (accessory purchased separately) Maximum Secure Digital card capacity GB Processor data Processor Intel Atom Z0PT Clock speed. GHz Cache kb L cache Number of cores Number of threads Maximum TDP. W Maximum RAM GB RAM type DDR SODIMM Number of memory channels Interfaces USB x Type A, USB./.0 Serial connection 9-pos. D-Sub, male Jumper selectable for RS-//8 Super I/O chipset Winbond W87DHG-PT Video VGA (DB-, female) Video chipset Intel GMA 00 Number of Ethernet connectors Ethernet connection 0/00/000 Mbps LAN chipset Intel 87IT 90_en_F PHOENIX CONTACT

Inputs Type Digital (sinking) Number of inputs Type of connection Removable Combicon screw-type Input voltage range 0 V DC Logic 0 voltage range 0 V DC Logic voltage range V DC Outputs Type Digital (sourcing) Number of outputs Type of connection Removable Combicon screw-type Nominal power supply V N 0 V DC Logic 0 voltage 0 V Logic voltage, nominal V N Output current per channel, maximum 00 ma Differential voltage V DC Mechanical tests Shock test according to IEC 008--7 Vibration resistance according to EN 008-- Conformance with EMC Directives Developed according to IEC 000-- IEC 000-- (ESD) IEC 000-- (radiated-noise immunity) IEC 000-- (burst) IEC 000-- (surge) IEC 000-- (conducted noise immunity) IEC 000--8 (noise immunity against magnetic fields) EN 0 (noise emission) g g Criterion B Criterion A Criterion B Criterion B Criterion A Criterion A Class A Approvals Listing U UL 08 90_en_F PHOENIX CONTACT

Dimensions 7 mm (.7 in) A mm (.9 in.) 7 mm (.78 in.) B mm (.0 in) Figure Dimensions Installation The VL BPC MINI can be mounted on an NS DIN rail or attached to a flat mounting surface such as a wall (mounting method must be selected when ordered). Be sure sufficient clearance exists for routing cables to the connectors or accessing any optional cards. When installing the VL BPC MINI in a cabinet, follow these general rules: Verify clearances within the cabinet. Typically, leave at least cm ( in.) on each side with.7 cm ( in.) on the connector side if the VL BPC MINI has any optional card slots. Drill all holes and make all cuts before beginning installation. Be sure to protect already installed components from shavings. Supporting panels must be at least gauge to provide proper support. Make sure that there is adequate space around the heat sink (on the back of the VL BPC MINI) and air inlets and outlets to provide sufficient cooling.. DIN rail mounting To install on DIN rail:. Angle the VL BPC MINI so the top edge of the mounting plate hangs on the top edge of the DIN rail.. Rotate the bottom of the VL BPC MINI down against the lower edge of the DIN rail. Press in until the latch snaps closed.. Secure with clamps. Figure A DIN rail installation and removal To remove from DIN rail:. Remove rail clamps and cables, as necessary.. Use a screwdriver to release the latch.. Rotate the bottom of the VL BPC MINI away from the rail and then lift it off the rail.. Wall mounting. Mark mounting holes in the mounting surface (wall) as indicated in Figure. Alternatively, hold the VL BPC MINI in position and mark the holes on the wall.. Drill holes in the wall as required. Mounting hardware (not included) will depend on the type of mounting surface.. Secure the VL BPC MINI to the wall using appropriate hardware. B 90_en_F PHOENIX CONTACT

7 8 9 0 VL BPC MINI 7 Interfaces After mounting the VL BPC MINI, make any necessary cable connections. Connections are always at the bottom of a mounted VL BPC MINI. The available connectors will vary depending on the configuration selected. For instance, not all VL BPC MINI will be equipped with an SD slot. Connectors and controls are located on the bottom and one side of the VL BPC MINI. RS-//8 USB Ethernet VGA X7: USB X8: USB X9: USB X: USB X: ETH X: USB X: ETH ERROR RUN CF PWR X: USB Power X0: COM X: PWR 9-VDC X: VGA X: CF + CompactFlash card slot Figure Bottom face connectors Input/output Power switch 7 8 X: DI/DO X: SD SD / MMC SD card slot Figure Side connectors The connections available are: Ethernet: Two RJ connectors are located on the rear of the VL BPC MINI. These allow the computer to communicate on a 0/00/000 Base-T Ethernet network. Serial: Serial devices connect to the 9-pos. D-Sub connector. This connector can be configured to communicate on the RS-, RS- or RS-8 physical layer (see Input/output configuration on page 9 for jumper settings). USB: USB devices connect using Type A connectors. The VL BPC MINI has six USB ports. VGA: This port connects the VL BPC MINI to an external analog display with a corresponding VGA connector. External display External analog displays can be connected to the VGA port of the VL BPC MINI (see Figure ). An Extended Display Identification Data (EDID) display will download its capabilities to the display driver while non-edid displays will not. In either case, additional settings can be applied through the Intel Graphics Media Accelerator. 90_en_F PHOENIX CONTACT

7. Service panel NOTE: Electrostatic discharge! The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD), in accordance with EN 0-- and EN 0--. There are two blocks of jumpers. On the inside of the plate is an illustration of the jumper positions and their functions. Jumpers on the circuit board provide the ability to configure the VL BPC MINI for specific applications. To access the jumpers:. Turn off the VL BPC MINI and disconnect the power supply.. Remove the VL BPC MINI to an ESD safe location.. Remove the four screws securing the access plate and remove the plate. Figure Label on inside of service panel Input/output jumpers (JP0) Serial port jumpers (JP7) Figure 7 Jumper block locations Figure Service panel removal To move a jumper, it may be gently grasped using a small needlenose pliers or large tweezers. Pull it straight out until it is clear of the pins. Reposition it over the desired pins and insert it straight on to the pins. 90_en_F PHOENIX CONTACT 7

7. Power connection A -position, screw-type Combicon connector (MSTB,/ -STF) is provided for connecting a power source to the VL BPC MINI. The following table shows the jumper positions for each possible COM port configuration. JP7 Function Jumper position 9 7 9 7 RS- ERROR RUN CF PWR 0 8 0 8 9 7 9 7 X: USB X: USB X: USB X: ETH X: ETH X: PWR 9-VDC + RS- 0 8 0 8 9 7 9 7 RS-8 0 8 0 8 Figure 8 Power connector The acceptable power supply range varies depending on the model. Connect power source to the included power connector (Order No. 788). This connector supports wire sizes from 0. to. mm² ( to AWG). Torque the wire retaining screws in the connector to 0. Nm (. lb f -in.) torque. Secure the connector to the VL BPC MINI chassis. PIN NO. DESCRIPTION (FE) Chassis Ground 0 V DC + +9 V DC The following table shows the function of each pin in the D-Sub connector with the different jumper settings. DB-9 RS- RS- RS-8 Pin DCD TXD- TXD- RXD TXD+ TXD+ TXD RXD+ Do not use DTR RXD- Do not use GND GND GND DSR Do not use Do not use 7 RTS Do not use Do not use 8 CTS Do not use Do not use 9 Function setup by JP0 Function setup by JP0 Function setup by JP0 7. Serial communication The COM port can be configured to communicate on the RS-, RS- or RS-8 physical layer. This is set using jumpers on the motherboard. NOTE: The maximum length of cable that can be connected to the COM port is 0 m when configured for RS-/8. Longer cable lengths can be achieved by using an external surge suppression device. 90_en_F PHOENIX CONTACT 8

Pin 9 in the COM port (D-Sub) connector can be configured to provide different voltages using JP0. JP0 Function + V Output Jumper position The VL BPC MINI can provide up to 00 ma current per output channel. Figure 9 shows a typical schematic for I/O connections with an external power source. 8 7 RI Input (default) + V Output + 7. Input/output configuration An 8-pin connector allows connection of three digital inputs and three digital outputs. Pin Number Description 8 Digital Input 7 Digital Input Digital Input Digital Output Digital Output Digital Output DIO Ground DO Power A Combicon screw-type connector (Order No. 877) is provided with the VL BPC MINI if equipped with this function. Figure 9 Typical I/O connection schematic 90_en_F PHOENIX CONTACT 9

8 Operation 8. LED operation Four LEDs are located on the bottom of the VL BPC MINI. These LEDs provide operating information. LEDs H ERROR RUN CF PWR H X: PWR 9-VDC + Figure 0 LED layout LED Indication Description ERROR Yellow Red Indicates reduced performance due to processor temperature Indicates an over-temperature condition has caused the processor to shut down RUN Reserved for future use CF Flashes Indicates CompactFlash activity green PWR Green When V DC is applied and the power switch is turned On 90_en_F PHOENIX CONTACT GmbH & Co. KG 8 Blomberg Germany 0 www.phoenixcontact.com