SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

Similar documents
CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

SC500/SC500P. Installation Note

MS-7000: SuperStar Reader

EL-ST100 KEYPAD CONTROLLER

User Manual. PCKeypad Wireless Keypad

MRC350 Card Capture Reader

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

GV-EL124S Electric Strike

MS-3000 MicroStar Reader

Mifare ID Reader. with selectable outputs

Waterproof. Keypad/Reader/Controller

Connecting a Cisco Reader Module

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Installing Keypad and Backplate

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

MS-5000: MiniStar Reader

RBR-SB-KTZ001 LAR 2. User Manual

Multi Card Technology

Installation Instructions RF5010 and RF5210

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

Stand-alone Proximity Access Control

W3-H Waterproof Keypad/Reader/Controller

Aceprox FSK Proximity Reader REV2 Data Sheet

Fingerprint Identification Proximity Reader. Quick Installation Guide

MS-4000: ShootingStar Reader

mifare ID Reader with Selectable Outputs Data Sheet

-DTZ001- Stand-Alone Proximity Access Control. User Manual

VIDI-AC-2CS Access Controller/ Reader

iclass INSTALLATION GUIDE

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

Pyramid Series Proximity Readers


Slimline LED Floodlight

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Digital Keypad Introduction

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data

ievo ULTIMATE INSTALLATION GUIDE

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

W3-M. Metal waterproof standalone access control/reader. User Manual

Documentation on all Paxton products can be found on our web site -

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

Analog Output Module Installation Instructions

Single Door Standalone Access Control User Manual

Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data

OEM Proximity Reader with Keypad Manual REV1

CM-110SK Standalone Keypad Installation Instructions

Enhancing Business Performance

GV-RK1352 and GV-R1352 Card Reader

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

FE8171V. 3MP 360 Panoramic View Vandal-proof

12 MODULE BAR ASSEMBLY INSTRUCTIONS EL3H12AØØ(x)

GV-Card Reader. User s Manual

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Gallagher T12 Reader. Installa on Note. The Gallagher T12 Reader

232iLM Keypad Installation and Programming Instructions

4. We recommend that you install the ievo reader at the DDA height of approximately 1 metre. This will be the perfect height for finger placement.

Security Expert Smartcard Reader Mini

Local Set Point Module Operating Bulletin

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

DOLXFD1000B. Waterproof Access Control/Reader

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Gallagher T20 Reader. Installation Note. The Gallagher T20 Reader

Installation and User Manual

Control Box Setup - PRSalpha

IBM. Rack Installation Instructions

Zodiac FR100 TM INSTALLATION MANUAL

Switch on / off. For switching off please press button for approx. 5 sec.

4 Channel DMX Driver Instruction Manual

Quick Start Guide. GV-CS1320 Camera Access Controller

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video

Keypad KEY-2.7. Instruction Manual

Installation procedure Hands free reader: L51 - R1x Variant

716 Converter. Programmable Data Converter

HSY-S209 EM Metal waterproof access control system User Manual

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

WELCOME. Network: Only use Shielded CAT5 cable for network communication.

Operating Instructions Wiegand Decoder with SD Card

Installation Instructions Models CC-5 / CC-2

R SERIES INSTALLATION GUIDE

Flat Panel Static Wall Mount MSP-SS (GSM-210)

Copy Machine Reader. Installation and Setup Guide

7612 Programming Instructions

Installation manual CF8-W-Disp-AL

IBA-7612 Programming Instructions

A note about our online installation instructions:

232iLM Keypad Installation & Programming Instructions

Inductive Proximity Sensor

REX F-0-9 Standalone or Access Controller

* ) Article No.: Article No.: MCS IV plus. Contents. Device descripition... 2 Technical Data... 2 Dimensions... 3 Accessories...

212iL Rev. 1.1

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Product Datasheet. Touch screen Part number OPERATOR INTERFACE

BluePass 2-N-1 BluePass Multi-Tech Reader Manual. Installation Instructions P/N: X15

Transcription:

DOC0067 Issue 1.2 Reader Wiring InSTRUCTIONS SP1 MP1 WP2 WP1 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes: MP1-EM1 MP1-HT1 MP1-DP1 WP1-EM1 WP1-HT1 WP1-DP1 SP1-EM1 SP1-DP1 SP1-DP1 WP2-EM1 MP1-LEG MP1-MIF MP1-ISO WP1-LEG WP1-MIF WP1-ISO

1. 2. 3. 4. 5. 6. Fitting the Slimline Reader Identify a suitable location for the reader at a convenient height near to the door that it controls. Mark out the position of the unit and then drill holes for mounting screws and the cable. Feed the cable through the wall and terminate it either at the access controller or in a suitable terminal box. Screw the reader to the wall using the screws provided and appropriate plugs/fixings (not supplied) for the type of mounting surface) Terminate the conductors according to the wiring details overleaf. Fit the label once the reader has been fully installed and you are confident that the unit will not need to be moved. 80 mm

125KHz Reader Wiring Connect the reader cable to the reader port of the controller according to the table below. For readers with a screw terminal block, refer to terminal numbering diagram. Terminal* Cable Function 1 Red +5VDC to +16VDC 2 Black Ground 3 White Wiegand Data 1 / Clock 4 Green Wiegand Data 0 / Data 5 Yellow Green LED input 8 Brown Beeper input 9 Orange Format Select (see below) 10 Blue Serial Data Output *Terminal Numbering 13 12 11 10 9 8 7 6 1 2 3 4 5 Format Select: Use the Format Select lead to set the required data output format by connecting it to either Ground or +VDC as follows: Reader Variant Connect to Ground Connect to +VDC EM1, HT1 10-Digit Clock & Data 26-Bit Wiegand DP1 26-Bit Wiegand 44-Bit Wiegand

Fitting The Reader Cover (MP1 and WP1) Once the reader has been fitted and wired, the cover can be fitted as described below (the illustration shows the mullion model but the procedure is the same for the wall switch model). 1. 2. 3. Hook the two tabs at the top of the reader cover over the top of the reader back plate, engaging them with the corresponding slots in the back plate. Hinge the cover over the reader body until it is correctly seated over the reader (it should click into place). Insert the cover retaining screw in the base of the reader and tighten. 1 2 3

13.56MHz Reader Wiring Connect the reader cable to the reader port of the controller according to the table below. For readers with a screw terminal block, refer to terminal numbering diagram. Terminal* Cable Function 1 Red +5VDC to +16VDC 2 Black Ground 3 White Wiegand Data 1 / Clock 4 Green Wiegand Data 0 / Data 5 Yellow Green LED input 6 Brown Beeper input 7 Blue Serial Data Output 8 Orange Format Select (see below) 1 2 3 4 5 6 7 8 *Terminal Numbering Format Select: Use the Format Select lead to set the required data output format by connecting it to either Ground or +VDC as follows: Reader Variant Connect to Ground Connect to +VDC ISO 10-Digit Clock & Data 32-Bit Wiegand MIF, LEG Dependant upon the customer specific version

Mounting the Wall Switch Reader Wall Switch readers are designed to fit to a standard wall switch back box (minimum depth 25mm). The WP1 can also be mounted directly on a wall (see the instructions for fitting a mullion mount reader). If the reader is to be mounted on a back box and is fitted with a cable, feed the cable through the hole in the back box to the controller and terminate the conductors according to the wiring details overleaf. If the reader is fitted with screw terminals, feed the connecting cable into the back box and terminate the conductors according to the wiring details overleaf. Secure the reader to the back box using the screws supplied. Note: To fit the Flush-mount Wall Switch reader to a back box, follow the mounting instructions above.

Power & Testing Once the reader is fitted and wired, carry out a brief test to ensure that it is functioning correctly. You may need to refer to the controller reference documentation. 1. 2. 3. Connect power to the controller and ensure that the LED lights red. The reader requires a supply of 5VDC to 16VDC. Present a compatible card to the reader and check that the LED blinks green and the beeper sounds (if fitted). Make a card valid in the access controller and present the card to the reader. Ensure that the card is accepted and the LED and beeper respond to the access controller as expected. This will depend upon how you have wired the reader and the way in which the access controller operates. If the card details are not recognised by the access controller, check all connections and ensure that you have connected the Format Select input correctly according to the table in the wiring instructions.. Note 1: The Slimline reader uses two separate LEDs for red and green indications but the basic operation is the same as other models. Note 2: If the LED does not give any indication at all when a card is presented, it is likely that the reader technology does not match that of the card.

Mounting the Mullion Reader Identify a suitable location for the reader at a convenient height near to the door that it controls. Place the reader on the mounting surface and mark the position of the cable hole. Drill a hole suitable for feeding the cable through. If the reader is fitted with a cable, feed it through the hole so that the reader can be positioned correctly against the mounting surface. Ensure that the reader is level and mark out the position of the fixing holes, drill and prepare the holes. Terminate the cable conductors according to the wiring details overleaf. If the reader is fitted with screw terminals, position the reader against the mounting surface, ensure that the reader is level and mark out the position of the fixing holes. Drill and prepare the fixing holes. Feed the connecting cable through the cable hole and terminate the conductors according to the wiring details overleaf. Secure the reader to the mounting surface using the two no.6 wood screws supplied with appropriate plugs/fixings (not supplied) for the type of mounting surface.

Specifications Supply Voltage MP1 WP1 WP2 SP1 5VDC to 16VDC Max. Current 250mA 70mA Read Range Up to 100mm Up to 50mm Up to 80mm Indications IP Rating Operating Temperature Dual colour LED (red/ green), Beeper IP65-20 o C to 50 o C Dual colour LED (red/ green) Red LED Green LED, Beeper For further details, view or download the corresponding product datasheet from the Nortech website at: http://www.nortechcontrol.com/document-library.aspx Product mounting templates are also available at this location.

Reader FITTING InSTRUCTIONS Fitting Mullion and Wall Switch Readers For those readers fitted with a cover (MP1 and WP1) ensure that the cover securing screw is not fitted to the base of the reader, and separate the front cover and the reader body as follows: Insert the tip of a terminal screwdriver into the small slot in the base of the cover. Press lightly to release the securing catch while you separate the cover from the reader at the base.