Size of Mounting Plate /2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards)

Similar documents
EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

BioPointe Reader Installation Guide

Installation & Operation Guide

1.0 Wiring and Layout Diagrams

EA500. Installation Instructions Transponder

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA

180 Series Keypad. Handbook. Revision 2.1

Leased-Line Extenders over IP

Guangdong Be-tech Security Systems Limited. Elevator Control Manual Instruction. Version 2013 Page1 total 22

Installation Instructions

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Installation OVERVIEW

SPX-7400_SPX-7410_MAN_161028

HuddleCamHD Serial Joystick Controller Model Number: HC-JOY-G3

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide

Installation and Programming Manual

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

CA-A480-A Elevator Controller. Reference & Installation Manual

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

Intelligent Devices IDI 1100 Series Technical Manual

INSTALLATION INSTRUCTIONS

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

PCIEMODBOX232 RS232 to PCI Module Box Introduction

Goto BRUKER BSMS, BSMS/2. RCB User Manual. Version 003 BRUKER

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

Single Phase Systems-North American PC125/PC420 Series

Suprex RS-485 SPX-7500 Wired Reader-Extender

ADDJOG User Guide 7/30/10. Overview

OMX-CI-RS232 Control Interface

FSA-CU Configuration Utility Programming Guide

H704-42(H)(E), H704-42/1(H)(E)

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Ethernet Adapter Installation Instructions

TX3 Series TELEPHONE ACCESS SYSTEMS. Installation and Operation Manual

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

VPN Routers. OnSite 2800 Series. Quick Start Guide

UC-2000 Installation Manual Unicorn Computers Technology Limited

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

GRX-CI-RS232 Control Interface

EnerSure Installation Guide

iconverter 1-Module Redundant Chassis

PXL-500/PXL-510: Firmware v8.4.30

L-MBUS20/L-MBUS80. User Manual. M-Bus Level Converter. LOYTEC electronics GmbH

Temperature Controller

THE CTB08D LIGHT CONTOLLER

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

istar Pro Installation Guide

Troubleshooting and Diagnostics

BCM2 Series Branch Circuit Monitors Quick Setup Guide

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

PXL-250 Tiger Controller

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

CommLink IV Technical Guide

Motorised actuator 0-10V EAC

rdczbk User Manual ZigBee to RS-232 / RS-485 Converter

Thermometer / Barometer System

CA111x-series Arming Station

High Voltage DC Meter

Three Phase Systems-International PC302-I/MTD

MANUAL INSTALLATION. Multi-Variable Monitor. MVM Series. Issue Date: 02/07/ Price Industries Limited. All rights reserved.

5000 Series Audio Matrix

Troubleshooting and Diagnostics

TAC I/NETTM 1284, 1280, Security Control Unit

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Serial Interface Module

USB to RS-422/485 Serial Adapter

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

TIME DELAY RELAYS Product Summary

LIGHTING CONTROLS PICTURED: ESL VISION 265W LED AREA LIGHTS WITH 50CC OCCUPANCY SENSOR, 0-10V DIMMING

Code Dynamics, Inc. Port Splitter

HIGH-VOLTAGE DC METER

GRX-CI-NWK-E Control Interface

DS232. RS232 to DMX Converter V4. ELM Video Technology s RS232 to DMX Converter / Controller

ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual

ETC Installation Guide

SC168MBM 16x8 Characters MODBUS MASTER LCD

TIME DELAY RELAYS TR-6 SERIES Time Ranger TM Programmable Multi-Range Plug-in Off Delay, Single Shot & Watchdog

CR3000 Copy Reader. Installation Guide

QSE-CI-NWK-E Control Interface

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Installation & Operation Guide

Quick Start Installation Guide

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

EMS467 Monitoring System. Installation and Operations Manual Section 40

PROGRAMMABLE MARQUEE DISPLAYS

2000 Series e/em Style Keypad Installation and Programming Manual

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

BA/BS4S Temperature Sensor Installation & Operating Instructions

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Series 3000 User Manual and Product Features

T3 Interface Converters

ADDENDUM. Date: August 4, 2004

Rev Cutler-Hammer Smart Breaker Panel Control Manual

Access control panel U-Prox IC E (Elevator control)

Transcription:

Remote Control Panel The Remote Control Panel (RCP), used in conjunction with PM4, PM5, Advantage, and VF Telephone Entry (TE) systems, serves as the control hardware for related access control functions, most commonly elevator controls. In this use, the unit is designed to supplement a TE system by providing floor access control in addition to port control without a proportional load burden being placed on the telephone entry unit. Each RCP, with added Expander Control Panels (ECP), can control up to 64 low current outputs (150 ma, AC/DC capacity). Standard RCP configuration is an RCP-16 which is designed for 16 low current outputs. An RCP requires a 12 VAC power supply. If existing power supplies are not capable of delivering the required voltage, an optional 120 VAC wall transformer can be used. 1.0 Specifications Size of Mounting Plate - 10 1/2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards) Environment - Temperature Range 0 to 100 F - Humidity 0% to 95% noncondensing Quick Start Guide Power Supply - 120 VAC 60 Hz Class II Transformer outputs 12 VAC @ 20 VA s/access Control Points 8 per ECP to a maximum of 64 (8 ECPs) - 150 ma - AC/DC - 30 V maximum - normally open Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 1 of 12

Quick Start Guide Remote Control Panel 2.0 Installation 2.1 Mounting Elevator RCPs Any RCP used to control an elevator can be installed in one of two methods, depending upon elevator design. The two methods are: 1. Installed directly on the elevator cab. 2. Installed in the elevator control room. Use the method which best serves to minimize wiring and facilitates the RCP interface with existing elevator control systems. For detailed information regarding RCP wiring interface with specific elevators, refer to the elevator manufacturer s service and installation manuals. NOTE: For safety and liability reasons, all connections to an elevator cab must be made by a certified elevator technician or installer. 2.2 Wiring RCPs 2.2.1 Connecting RCPs to the Telephone Entry System Communication is established between the TE system (via DB-25 connector) and the RCP (10-pin connector) via the TE system s RS-485 serial port connector using two sets of twisted pair wires. see Table 1 for wiring a PM4, PM5, or Advantage TE system to a single RCP see Table 2 on page 3 for wiring a VF TE system to a single RCP see Table 3 on page 3 for wiring multiple RCPs together via a daisy-chain Table 1: Wiring a PM4, PM5, or Advantage TE System to a Single RCP TE DB-25 Pin RCP J2 Pin 2 Tx- 6 Rx- 1 Tx+ 5 Rx+ 14 Rx- 4 Tx- 15 Rx+ 3 Tx+ Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 2 of 12

Remote Control Panel Table 2: Wiring a VF TE System to a Single RCP TE BS2 Pin RCP J2 Pin 6 Tx- 6 Rx- 5 Tx+ 5 Rx+ 4 Rx- 4 Tx- 3 Rx+ 3 Tx+ Table 3: Wiring Multiple RCPs Together RCP 1 Pins RCP 2 Pins RCP 3 Pins 7 Tx+ 5 Rx+ Quick Start Guide 8 Tx- 6 Rx- 9 Rx+ 3 Tx+ 10 Rx- 4 Tx- 7 Tx+ 5 Rx+ 8 Tx- 6 Rx- 9 Rx+ 3 Tx+ 10 Rx- 4 Tx- 2.3 Wiring ECPs to RCPs The basic RCP-16 board is delivered with one RCP board and two ECP boards mounted on the Mounting Plate. The necessary connections have been made at the factory. The required connections are provided here for troubleshooting purposes. For RCPs with additional ECPs, the only changes are in the board addresses (in increasing order, set at the factory), and the additional wiring of the output points. The internal RCP connections have been made at the factory. 2.3.1 Connections A 16-pin ribbon cable runs from the RCP to each ECP board. This is a parallel connection. See Figure 1 on page 4 for pin orientation. Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 3 of 12

Quick Start Guide Remote Control Panel Figure 1: The RCP and ECPs on a Mounting Plate The board address for each ECP is set by a jumper at the factory and the software interface information is hard coded into the RCP at the factory. Do NOT move this jumper unless directed to by a Tech Support technician. Moving the jumper will result in communication problems between the RCP and the ECP boards. The cable and the address jumper are the only connections/settings required for proper operation of the RCP and the ECPs. All other connections are for system power or for the operation of control points. Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 4 of 12

Remote Control Panel 2.4 RCP Setup There are three things to do before wiring the RCP to control points (see Figure 2). 1. Verify all dip switches are set to OFF. Do NOT change these settings. 2. Connect a jumper between pins 4 and 6. 3. Run power to the RCP from a 120 VAC transformer. Connect power using a twisted-pair of AWG 18 wire to AC IN (pins 7 and 8). Quick Start Guide Figure 2: RCP Setup Connections NOTE: The PROM installed on the RCP must be at revision 1.6 for proper operation with ECPs (see Figure 1 on page 4). Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 5 of 12

Quick Start Guide Remote Control Panel 2.5 Wiring an ECP to its Control Points Each control point must be individually wired using AWG 22 twisted-pair wire (long distance runs may require a heavier gauge). Figure 3 displays output point locations; Table 4 displays output point number per ECP card. When in operation, output LEDs identify when an RCP output is active; one LED per output point. Figure 3: ECP Setup Connections ECP # A B Table 4: s by ECP C D E F G H 1 1 2 3 4 5 6 7 8 2 9 10 11 12 13 14 15 16 3 17 18 19 20 21 22 23 24 4 25 26 27 28 29 30 31 32 5 33 34 35 36 37 38 39 40 6 41 42 43 44 45 46 47 48 7 49 50 51 52 53 54 55 56 8 57 58 59 60 61 62 63 64 Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 6 of 12

Remote Control Panel 2.6 Power LED Sequence To verify proper RCP/ECP configuration, the LEDs on the ECP blink in a specific sequence when the unit is powered on. When power is first applied to the RCP, the Green power LED on the RCP blinks 5 times. The Yellow ECP output LEDs turn ON from left-to-right, top board to bottom board until all LEDs are lit. Then the LEDs turn OFF in the order they came on. Quick Start Guide Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 7 of 12

Quick Start Guide Remote Control Panel 3.0 Programming for PM4, PM5, and Advantage Units 3.1 To Assign Floors to a Given Tenant Directory Number This command allows you to assign elevator floor access to a tenant through the tenant s directory number. 1. Press *. 2. Enter the 8-digit programmer passcode. 3. Press #. The Enter lamp should be on indicating the unit is now in programming mode. 4. Press * 1 8. 5. Enter the 2 or 3-digit directory number of the tenant for whom you want to assign a Floor Number. 6. Enter the Floor Number. When entering a Floor Number, you must enter leading 0s to fill the Floor Number out to a 3-digit number. 7. Press # #. This exits you from programming mode. Examples: To assign tenant directory number 101 to floor number 007 (a 3-digit directory number): * <8-digit passcode> # to enter programming mode * 1 8 1 0 1 0 0 7 # to assign floor 7 to tenant directory number 101 # # to exit programming mode To assign tenant directory number 12 to floor number 007 (a 2-digit directory number): * <8-digit passcode> # to enter programming mode * 1 8 1 2 0 0 7 # to assign floor 7 to tenant directory number 12 # # to exit programming mode Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 8 of 12

Remote Control Panel 3.2 To Delete an Elevator Floor This command allows you to delete an elevator floor from the list of accessible floors. The command is similar to assigning a floor to a tenant directory number, but by entering 000 as the tenant directory number the floor is deleted. 1. Press *. 2. Enter the 8-digit programmer passcode. 3. Press #. The Enter lamp should be on indicating the unit is now in programming mode. 4. Press * 1 8. 5. Enter 000 as the tenant directory number. 6. Enter the Floor Number to be deleted. When entering a Floor Number, you must enter leading 0s to fill the Floor Number out to a 3-digit number. 7. Press # #. This exits you from programming mode. For example: To delete elevator floor number 13: * <8-digit passcode> # to enter programming mode * 1 8 0 0 0 0 13 # to disable access to floor 13 # # to exit programming mode Quick Start Guide 3.3 To Assign an Elevator Panel Timeout Value This command allows you to set the amount of time an elevator control panel s buttons remain active after a valid code has been entered. This command allows you to set a separate timeout for the elevator (as opposed to using the door unlock timeout command). The timeout range is from 1 to 240 seconds. 1. Press * 2 2. This enters the timeout value command. 2. Enter the timeout value in seconds (a minimum of 20 seconds is recommended). When entering a timeout value, you must enter leading 0s to fill the timeout value out to a 3-digit number. 3. Press #. This exits you from programming mode. Example: To set the elevator panel timeout value to 20 seconds: * 2 2 to enter the timeout value command 0 2 0 to set the timeout value to 20 seconds # # to exit programming mode Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 9 of 12

Quick Start Guide Remote Control Panel 4.0 Programming for VF Units 4.1 Enabling Elevator Control This command allows you to enable elevator control through the RCP. 1. Press #1234. Ignore the Invalid Password message; it is a decoy to deter random access attempts. The screen displays as follows. Entraguard System Local Programming Enter Password XXXXXXXX 2. Enter your password and press E. 3. The screen displays one of the following three messages depending upon the programming rights assigned to your password. Factory Edit Mode Installer Edit Mode User Edit Mode 4. After a brief delay, the screen displays as follows. Tenant Edit - Press 1 Parameter Edit - Press 2 Set Clock - Press 3 End Edit - Press 4 5. Press 2 to enter the Parameter Edit mode. 6. Use the up and down arrow keys to scroll to the Elevator Control parameter. Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 10 of 12

Remote Control Panel 7. Press E. The screen displays as follows. Elevator Control <status> Press 0 to Disable Press 1 to Enable 8. Press 0 to Disable Elevator Control or Press 1 to Enable Elevator Control. Once entered, the Elevator Control status is displayed. 9. If Elevator Control is Enabled, press * to display the Door Open Time. The screen displays as follows. Door Open: 120 sec Quick Start Guide 10. The factory default door open time is 120 seconds. If you wish to change this time, use the up and down arrows to scroll to the desired time. The time can be set anywhere from 10 seconds to 120 seconds in 5 second increments. 11. When finished, press E to exit the Elevator Control command. 12. Press 4 to exit Local Programming mode. Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 11 of 12

Quick Start Guide Remote Control Panel This page is intentionally left blank. Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 12 of 12