EPILOG LASER Table Mountain Parkway Golden, Colorado Phone FAX

Similar documents
Laser Alignment. For the Epilog Fusion CO2 10/10/2013

NAV-1 Lens Support. NAV-2 Lens Support BEFORE YOU BEGIN

Canon EOS Rebel XTi Tripod mount

Further Information can be found at

Rack Installation Instructions

Microscopic Imaging Research Station (MIRS) Assembly Guide. Version 1.0.0

Installing the Server into a Rack

System Storage EXP3000 Rack Installation Instructions

EMC 10T "CE" Mechanical Upgrade Procedure

Copyright Black Box Corporation. All rights reserved.

CIB 3047 (14B) 10-Button Voice Terminal Fixed Desk Stand and Wall Mount (32007)

Mac Mini Mid 2011 SSD Dual Drive Installation

Ultra short throw lens installation

Kodak Retina II (type 122)

ST101-SR Installation Guide

Setup Information Panosaurus May 3, 2011

Cutter Option Installation Instructions

Installation Guide GE Healthcare Solar 8000M Keypad Mounting Kit for 15'' and 18'' Flat Panel Displays

Codonics Virtua Virtua-2 Optical Drive Replacement

imac Intel 27" EMC 2639 Hard Drive

Plasma Panel Replacement Guide DU-42PX12X

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

Mac Mini Mid 2010 SSD Installation

Printhead Replacement and Adjustment Guide for the CD Printer Revision B

StealthyPro Instructions

Written By: Walter Galan

Upgrade Instructions Printer Terminal Holder

INSTALLATION INSTRUCTIONS

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

ipod Classic Headphone Jack & Hold Switch Replacement

ipod Classic Click Wheel Replacement Written By: irobot ifixit CC BY-NC-SA Page 1 of 25

Dear user. You will find actual information about our products on Seite 1 / 6

Mac Mini Mid 2011 SSD Installation

CDRPanP. Installation. Instructions for Instrumentarium OP-100 FOR PANORAMIC SYSTEMS. Schick Technologies, Inc. Avenue

Quick Start Guide Ioline StudioJet

CONTENTS. Application Guide ADA Auto Raster TM Pen Configuration Guide for EGX- 400/600. October 19, 2015

Removal and Installation8

Ribbon Supply Spindle Maintenance Kit

SSD Dual Drive Installation

imac Intel 21.5" EMC 2389 SSD Dual Drive

Canon PowerShot SD 600 Rear Control Board Replacement

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

TDM To MiniMech conversion ProceDure

Mac mini Mid 2010 IR Sensor Replacement

CARD PRINTER PRINTHEAD REPLACEMENT INSTRUCTIONS

Mac mini Mid 2011 IR Sensor Replacement

Written By: Walter Galan

HP rp5700 Repair Central Processing Unit(CPU) Replacement

Written By: Andrew Bookholt

Olympus Stylus Tough TG-2 ihs Lens Assembly Replacement

Written By: senordingdong

MacBook Pro 17" Unibody AirPort Board Replacement

MacBook Core Duo Optical Drive Replacement

User Manual THALES SIMPLICITY II

3 Indexer Installation For PRSalpha Tools

CAMERA ASSEMBLY. Removal/Replacement of the Camera Box Assembly APR-CA. Install Camera Assembly. Remove Camera Assembly

TrueNAS Z SERIES NODE SATADOM REPLACEMENT KIT. August 2017 Edition

NewScope-T0 Operation Manual

MacBook Core 2 Duo Clutch Cover

CIB 3097 ESD Suppression Kit

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website:

MacBook Core 2 Duo Display Replacement

Print Mechanism Maintenance Kit

Reflowing Xbox 360 Motherboard

LS-785 High Throughput Lens Spectrograph User Manual

ColorMaxLP Label Roll Rewinder

imac Intel 21.5" EMC 2389 Stand Replacement

imac Intel 27" Retina 5K Display CPU Replacement

Mac mini Mid 2011 Hard Drive Replacement

Wall Mount Kits. To check which phone model you have, press Applications number field shows your phone model. and select Phone information.

G12/G12x USER S MANUAL

Peel & Present Option Rev.C

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

INSTALLATION GUIDE Version 1.0

Sony NEX-7 Screen Replacement

APES-14 HD-6500 & HD-7000 Version Operator s Training Manual

MacBook Core 2 Duo Optical Drive

Epilog Laser Setup And Jig Operations

Flat Panel Static Wall Mount MSP-SS (GSM-210)

HARMONi G3. Quick Start Guide for HARMONi G3. imac Processor/FireWire Upgrade

Mac mini Mid 2011 Heat Sink Replacement

Eco D-ELS-4 Stereo Microscope. Instruction Manual

Z Series and S4M Ribbon Take-Up Spindle Maintenance Kit

ASI Photoport TIRF Injector Instruction Manual

Cone Beam Volumetric Tomography and Panoramic Dental Imaging System

SECURITY MODULE UPGRADE

Xbox 360 Motherboard Replacement

3D SYSTEMS University CubeX 3D Printer

Replacement Instructions

Mac mini Late 2018 Memory (RAM) Replacement

Validator Update Instructions for Rowe BC1200 $1 - $20

Lab 4: Trajectory Following 1

P160 User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario

Canon Powershot S200 Camera lens Replacement

Print Head Replacement and Adjustment Guide for the CD Printer Revision C

PowerBook G4 Aluminum 17" GHz PRAM Battery & USB Board Replacement

ASSEMBLY ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

Xbox DVD Drive Disassembly

Sonnet AV/HPV Card Video Adapter Kit

Transcription:

EPILOG LASER 16371 Table Mountain Parkway Golden, Colorado 80403 Phone 303-277-1188 - FAX 303-277-9669 www.epiloglaser.com Procedure Title: Replacing the Optics in your FiberMark Laser Engraver Tools Needed: o #1 Phillips Screwdriver (For Side Panel) o #2 Phillips Screwdriver (for Mirror Mounts) o 3/32 Allen Wrench o 1 ea. 5/64 Allen Wrench (for mirror mount over lens) o 1 ea Magic Marker Supplies provided: o 1 ea. Alignment Target, provided with replacement optics o 3 ea. mounted replacement mirrors o 1 ea. un-mounted replacement mirror Note: o Due to the construction of the Fiber Laser, this alignment will be performed using the Red Dot Pointer. There is no need to align the red dot to the laser, as they are aligned internally in the laser. o The laser will be aligned after each replacement optic is installed. This will simplify the alignment process. Some conventions: o The front of the machine is where the control panel is located. When facing the front of the machine, left is your left, and right is your right. o After a mirror is replaced, the engraver will be re-aligned. When making alignment adjustments for this procedure, only make adjustments to the last mirror replaced. This will simplify the alignment process. Once all of the mirrors have been replaced, we will double check the entire machine for alignment. Procedure: 1. Turn off the power to the engraver 2. Unplug the engraver from its power source

3. Remove the power cord from the engraver. 4. Remove the 6 #2 Phillips screws which secure the left hand side access panel. There are 4 on the side and 2 on the rear. 5. Move the lens carriage to the center of the engraving table. Note: We have included spare mounting mirror mounting screws for the mirror over the lens, but because the screws are very small, it is a good idea to place a piece of paper or plastic on the table surface to prevent the screws from falling through the holes in the table. 6. With the provided 5/64 Allen wrench, remove the 4 mounting screws which attach the mirror retainer to the mirror holder. As the screws are removed, place them on the table surface. Do not leave them in the mirror retainer. 7. Carefully remove the mirror retainer from the mirror mount. 8. Remove the o-ring from the rear of the mirror 9. Remove the mirror from the mirror mount 10. Remove the un-mounted replacement mirror from the package. 11. Install the replacement un-mounted mirror in the mirror mount, shiny side down. When looking at the lens carriage assembly from the top, you should see the dull or frosted side of the optic. 12. Place the o-ring in the mirror retainer. 13. Gently place the mirror retainer over the mirror, ensuring that the o-ring is in place. 14. Install the 4 mounting screws, but do not tighten at this time. 15. Once all of the mirror mounting screws have been installed, gently and evenly tighten the mirror mounting s. DO NOT OVER TIGHTEN. NOTE: Because the position and alignment of this mirror is fixed, there is no need to perform an alignment at this step in the process. 16. On the far left hand side of the X-Axis assembly, is a mirror mount. This mirror mount is made of 2 components. The Mirror support and the Mirror mount. a. The Mirror support is Brass in color and has knurled ridges around the outside, similar to a quarter. b. The Mirror mount is aluminum in color and has NO knurled edge.

17. While standing in front of the engraver, grasp the Mirror mount, No knurled edge, with your index finger and your thumb. Turn the knurled portion of the mirror support toward you. Note, because you are standing essentially behind the mirror, the removal of the mirror on the threads may appear reversed. 18. The threads on the mirror support are about ¼ inch long. Turn the mirror support until the mirror comes off in your hand. 19. Remove one of the mounted replacement mirrors from the package and install on the mirror mount. 20. Locate the alignment target that was provided in your replacement optics kit, and place it in the lens carriage. 21. Invoke the Red Dot pointer by depressing the Pointer button on the display panel. 22. On the control panel, depress the X-Y Off button. 23. Depress Go to disable the Axis. The carriage should now move freely around the table. NOTE: The Red Dot pointer on the Fiber Laser is quiet large, roughly 3/8 of an inch when it is projected on to the surface of the target. 24. Move the lens carriage to the far right hand side of the engraver. If the Red Dot image is on the target, using the adjustment screws on the back of the mirror mount, move the red dot in to the center of the target. Carriage Mirror (Mirror 2) Adjustment Diagram: Diagram 1

25. Locate the ORANGE periscope. This is located in the upper left rear corner of the engraver, behind the side panel that was removed earlier. Left side of engraver Arrow denotes the Periscope Diagram 2 26. With your magic marker, draw an up facing arrow on both of the mirror mounting plates, as shown in the picture. This will make realigning the engraver much easier. 27. Remove the 4 #1 Phillips screws from TOP mirror mounting plate. 28. Gently lift the Mirror mounting plate up from the periscope 29. Remove the mirror from the Mirror mounting plate by turning the mirror and the mirror support counter. 30. Install the replacement mirror and mirror support on the mirror mounting bracket. 31. Place the Mirror mounting bracket back in the periscope ensuring that the arrow that was drawn earlier points up. Install the mounting screws 32. Turn on the Red Dot pointer. 33. Move the X-Axis rail to the rear and the lens carriage to the far left hand side of the engraver. 34. Visually inspect the position of the red dot. Adjust the Top mirror in the periscope until the red dot is centered in the alignment target.

Periscope Upper Mirror (Mirror 3) Adjustment Diagram: Diagram 3 35. With your magic marker, draw an arrow on the mirror mounting plate to indicate up. 36. Remove the 4 mounting screws from the Mirror mounting plate. 37. Gently remove the mirror mounting plate from the periscope 38. Remove the mirror and the mirror support from the mirror mounting bracket by turning the mirror and the mirror support counter. 39. Install the replacement mirror and mirror support on the mirror mounting bracket. 40. Reinstall the mirror mounting bracket in the periscope. Ensure that the arrow points up. 41. Secure the mirror mounting plate with the 4 Phillips screws. 42. Turn on the Red Dot pointer. 43. Move the lens carriage to the left rear of the engraver and adjust the red dot until it is centered on the target.

Periscope Lower Mirror (Mirror 4) Adjustment Diagram: Diagram 4 44. Depress Reset to re-enable the axis, and to send the lens carriage back to the home position This completes the replacing the optics portion of this technical note. Confirming the Alignment 45. Install the Alignment target in the lens carriage 46. Turn on the Red Dot pointer. 47. Depress the X-Y Off button on the control panel. 48. Depress the Go button, the carriage can now be moved around the table. 49. Move the lens carriage to the left rear corner (position 1) of the engraver. 50. Check to see if the Red Dot is centered on the target. 51. If the Red Dot is not centered on the target, using the Lower periscope mirror and the Periscope Lower Mirror (Diagram 4) Adjustment Diagram above, adjust the Red Dot so that it is centered on the target. 52. Move the lens carriage to the left front of the engraver. 53. Using the Upper periscope mirror and Diagram 3 so that the Red Dot pointer is centered on the alignment target.

54. Move the lens carriage back to position 1 to verify that the alignment has not changed. If it has moved, complete steps 49 through 53 again, until there is little change in the red dot position when you move from the front to the back. 55. Move the X-axis rail to the rear of the engraver. 56. Check to see if the Red Dot pointer is on the target. Adjust as necessary to move the Red Dot image to the center of the target. 57. Move the lens carriage to the right, watching the position of the Red Dot, if it moves off of the target, stop; move the lens carriage back and adjust so the red dot is in the center of the target. Otherwise move the lens carriage to the far right hand side of the engraver, and adjust so that the Red dot is in the center of the alignment target. 58. One last time, with the Target in place and the Red Dot pointer on, move the lens carriage to the outer limits of the table, making sure that the Red Dot image stays in the center of the target. 59. You have now completed the Updating your FiberMark Optics. If you have any questions please call Epilog s Technical Support Phone 303.215.9171 Fax 303.531.7594 E-Mail: tech@epiloglaser.com

Carriage Mirror (Mirror 2) Adjustment Diagram: Periscope Upper Mirror (Mirror 3) Adjustment Diagram:

Periscope Lower Mirror (Mirror 4) Adjustment Diagram: