CONNECT AND PROTECT. nvent ERICO Critec SRF N-Series. Surge Reduction Filters

Similar documents
LPI SG + SS480 Spark Gap Surge Filters

LPI SST Surge Filters

Technical Data Sheet Medium Current Power Surge Filters

LPI SG + SST Spark Gap Surge Filter

TDS Transient Discriminating Surge Diverters

TDX Series. Transient Discriminating TM TVSS

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

White Paper. AC Surge Protection. Evaluation of Series Element Surge Protective Device for Protection of Electronic Equipment and Systems

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

ENGR. MARITES R. PANGILINAN, P.E.E.

glossary GE Digital Energy Power Quality Surge Protective Devices (SPDs)

SPM Series Plug-in Surge Protection

nvent ERICO Protection Solutions from the Ground Up nvent.com/erico 1

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

SPM Series. Plug-in Surge Protection

Fundamentals of Thyristor Overvoltage Circuit Protection

GLOSSARY OF TERMS. Surge and Lightning Protection ERICO Inc.

BS th Edition wiring regulations Furse overview

The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE

Surge Protection Devices Ex9UE2

Surge & Filter Protection Addressing your industrial power quality needs.

3 Design of the electrical installation protection system

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

Commercial and Industrial LV Power Protection

GE Digital Energy. Power Quality

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

L*W*H:120*65*35.5 L*W*H:152*133*48 L*W*H:220*143*48 L*W*H:360*280*132 for 1ph 5A~10A for 1ph 10A~16A for 1ph 20A~45A for 1ph 50A~120A/200kA

White Paper Surge Protective Devices in Automatic Transfer Switches

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

Tel: Web: Lightning and surge protection help pages

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Table of Contents. Safety. Attention. Warnings

Surge Protection Solutions

Lightning Current Equipotential Bonding SPDs

US Catalog March Surge protective devices (SPDs) UL range

Coordinated Facility Protection Selecting Surge Protection

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

Dirty Power... A Guide to Surge Suppression & Filtering. Surge & Signal Protection for Business-Critical Continuity. EmersonNetworkPower.

Remote telecom site protection

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

Overvoltage Protection

Surge Protection for Surveillance Systems

In the simplest terms, surge protective devices (SPDs) prevent damaging transient voltage surge levels from reaching the devices they protect.

2 Principle of lightning protection

AC Line Voltage Transients and Their Suppression

SURGE SUPPRESSOR INSTALLATION INSTRUCTIONS. Includes TDS-AR Alarm Relay and TDS-SC Surge Counter. ISSUE: 3 April

Product Overview 2Pro AC Devices Provide Overcurrent/Overvoltage/ Overtemperature Protection for AC Industrial and Appliance Applications

Quality assurance Test Facilities for Gapless ZnO Surge Arresters in High Voltage Division of CPRI, Bengaluru

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protection Devices Type 1+2

Surge Protective Devices. STV100K Series. Instruction Manual

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

Lightning and Surge Arresters

LIGHTNING PROTECTION

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Surge Protector. Esma Khatun

SPD Catalogue. SPD Catalogue. for AC applications

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

How to Select the Best Value Transient Voltage Surge Supressor for Your Equipment

ZoneMaster Series Surge Protection Devices

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

This is a preview - click here to buy the full publication TECHNICAL REPORT

High Performance Output Filter Instruction Manual

S400 Series HIGH EFFICIENCY SURGE PROTECTIONS. For power supply For measurement and control devices For LAN / ICT Networks

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Surge Current Capacities

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

"Powering and Protecting Networks and Equipment Connected to It" Jim Pelegris ITW/LINX

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Surge Protective Device

STEP-PS/1AC/24DC/1.75

Overvoltage Protection Devices

Coordinated Facility Protection Selecting Surge Protection

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

TECH NOTE #: CPS-1 SUMMARY OF APPLICABLE UL AND IEEE STANDARDS

Plugstrip and Wallmount Surge Protectors

Handling Transient Threats in RS-485 Systems

Equipment protection

NEW surge protective devices

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

RT4B-110V/12A RECTIFIER

BSPD Surge Protective Devices

Telcordia GR-1089-CORE Issue 4 Topics Primary Protection

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

MINI-PS AC/10-15DC/8

Power Electronics. Semiconductor relay / - contactor

METAL OXIDE VARISTORS

Contact protection relay

Data Sheet. Surge protection devices - A technical overview

Cirprotec Technical Article No. 5

Lightning & Surge Protection for Wind Turbine Systems

Surge Protection for Low Voltage Power Systems

Transcription:

CONNECT AND PROTECT nvent ERICO Critec SRF N-Series Surge Reduction Filters

TABLE OF CONTENTS PROVEN FOR CRITICAL APPLICATIONS... 3 SRF N-SERIES COMBINED TECHNOLOGY PROTECTION... 4 SPARK GAP TECHNOLOGY... 5 FILTERING TECHNOLOGY... 6 TRANSIENT DISCRIMINATING TECHNOLOGY... 8 COMBINING TECHNOLOGIES INTO THE ULTIMATE AC SURGE PROTECTOR... 10 SURGE REDUCTION FILTER N-SERIES, SINGLE PHASE... 12 SURGE REDUCTION FILTER N-SERIES, THREE PHASE... 14 2 nvent.com/erico

Proven for Critical Applications nvent ERICO pioneered the development of the Surge Reduction Filter commencing in the 1980 s, and since then tens of thousands have been installed in some of the highest lightning areas of the world. A policy of continuous product improvement has seen updated performance levels, culminating in the SRF N-Series. They are renowned for their application in critical sites, with common application to telecommunications sites, data centers, process control plants, defense installations, and airports. DEFENSE TELECOMMUNICATIONS DATA CENTERS SCADA PROCESS CONTROL AIRPORTS nvent.com/erico 3

SRF N-Series Combined Technology Protection nvent ERICO Critec SRF N-Series combines rugged Spark Gap technology with effective true L-C filtering and Transient Discriminating (TD) Technology to help create the ultimate in effective and reliable AC surge protection. PRIMARY SURGE DIVERSION Spark Gap Technology for high surge handling capability FILTER CIRCUIT High efficiency iron powder cored inductors Robust capacitors safety agency approved SECONDARY SURGE DIVERSION TD Technology for high over-voltage withstand HIGH RELIABILITY Direct connection from Input to Output FILTER PERFORMANCE Filter circuit reduces rate-of-voltage rise (dv/dt) and let-through voltage, providing improved protection for electronic equipment STATUS INDICATION Comprehensive front panel status and internal diagnostic LEDs ENCLOSURE Up to IP 65 rated Internal parts touch finger safe IEC STANDARDS COMPLIANT Increased safety and performance 4 nvent.com/erico

Spark Gap Technology The SRF N-Series has as its primary surge diversion stage a high-energy Spark Gap from each phase to neutral and from neutral to ground. These devices offer remarkable surge diversion capability (rated at 130 ka 8/20 μs, 50 ka 10/350 μs), that allows them to handle partial direct strike lightning currents. The range has been tested to the IEC standard Class I tests to ensure that the filter can be installed in a high lightning area and withstand those surge currents that can occur from a direct strike to the facility. The design of the Spark Gaps used is such that they have fast operating characteristics while extinguishing after the surge has passed, drawing low levels of follow current even on high prospective short circuit current services. nvent.com/erico 5

Filtering Technology Surge protection devices may include a filtering stage to help condition the waveshape, thereby providing superior protection for sensitive electronics. This said, it is important to realize that a number of different topologies of filter circuit exist, each providing significantly different performance. At its simplest, a manufacturer may include a capacitor in parallel with the output. This may serve to reduce any fast ringing voltages and will also help absorb the energy in a small transient thereby providing a limited level of attenuation. A far more effective approach is the series LC filter. This type of filter is connected between the surge limiting components and is in series with the supply powering the equipment. It consists of series inductors and parallel capacitors. Surge protection devices of this nature are often referred to as two port devices since they have a distinct input and output side. The SRF N-Series use true series connected LC filtering. Since the load current feeding the equipment to be protected has to go through the SRF, the inductors have to be rated to carry this load current. As a consequence, the range consists of a number of models to suit increasing load currents, with the larger current models being physically larger. In addition to the heavy duty inductors, the capacitors used in this filter stage are of a special high reliability type, having received safety approvals from a number of ratings agencies. Finally, the type of filter needed for a Surge Reduction Filter is very different to that used for higher frequency RFI/EMI (Radio Frequency Interference/Electromagnetic Interference) filters. These simple filters use small components that are effective for higher frequencies but are ineffective against lightning surge frequencies. The IEC standard for testing and assessing the performance of Surge Protective Devices (IEC 61643-11) defines the let-through voltage of the SPD as the Voltage Protection Level, Up. Under standardized test conditions, this is determined for each SPD tested. Traditional Spark Gap technologies, while being rugged, have a relatively high Up, usually in the range of 2 kv to 3 kv. Metal Oxide Varistors (MOVs) perform better at clamping the voltage, having typical Up values in the range of 1500 V to 1800 V. When subjected to the same tests, the SRF N-Series have dramatically lower Up values in the range of 450 V to 650 V. Of course, the lower the value of Up, the better the SPD prevents damage to the equipment being protected. SPDS WITH FILTERS OFFER TWO PRIMARY BENEFITS: VOLTAGE PROTECTION LEVEL, Up (1) They reduce the transient voltage reaching the equipment. (2) They reduce the rate-of-rise of the leading edge of the impulse. The residual leading edge spike after a standard SPD, although it may only be 500 V to 900 V in amplitude, can cripple electronics due to its extremely high rate-of-voltage rise of 3,000-12,000 V/μs. Effective filtering reduces this rate-of-rise to less than 20 V/μs. This slower change in voltage is better withstood by electronic equipment using switched mode power supplies. The filter also helps to attenuate small signal RFI/EMI noise problems. 3000 2500 2000 1500 1000 500 0 Traditional Spark Gap Typical MOV Typical SRF N-Series 6 nvent.com/erico

ARRIVAL OF SURGE kv 6 kv Risetime = 1.2 μs V(t) 50 μs μs Input surge typically up to 6 kv and 500 μs duration. dv/dt - 5000 V/μs dv/dt - 5V/μs THE CONSTRUCTION OF THE SRF N-SERIES TRUE INDUCTOR-CAPACITOR (LC FILTER) In order to provide the excellent filtering performance, the filters are constructed with separate inductor and capacitor elements. The inductors are constructed from high quality iron powder cores, ensuring high efficiency and quiet operation. The capacitors employed are high reliability types, having received safety approvals from ratings agencies. nvent.com/erico 7

Transient Discriminating Technology To meet the fundamental requirements of performance, longer service life and greater safety under real world conditions, nvent ERICO developed Transient Discriminating (TD) Technology. This quantum leap in technology adds a level of intelligence to the Surge Protection Device enabling it to discriminate between sustained abnormal overvoltage conditions (Temporary Over Voltages TOVs) and true transient or surge events. Not only does this help ensure safe operation under practical application, but it also prolongs the life of the protector since permanent disconnects are not required as a means of achieving internal overvoltage protection. TRADITIONAL TECHNOLOGIES The diagram shows how a traditional SPD is chosen to have a nominal clamping voltage that is above the peak of the nominal AC mains voltage. However, in the lower diagram, it can be seen that when the AC mains experiences a Temporary Over-Voltage (TOV), the SPD attempts to clamp the overvoltage, and rapidly heats up, resulting in failure, potentially accompanied by fire or explosion. Nominal Clamping Voltage on 50/60 Hz Nominal AC Mains Operating Voltage Conventional SPD technologies utilizing metal oxide varistors and/or silicon avalanche diodes to clamp or limit transient events are susceptible to sustained 50/60 Hz mains over-voltage conditions (TOVs) which often occur during faults to the utility system. Such occurrences present a significant safety hazard when the suppression device attempts to clamp the peak of each half cycle on the mains overvoltage. This condition can cause the device to rapidly accumulate heat and in turn fail with the possibility of inducing a fire hazard. SPD in Conduction TOV Condition Repetitive Clamping Causes SPD to Heat Up, Possibly Exploding or Causing a Fire Nominal Clamping Voltage on 50/60 Hz Nominal AC Mains Operating Voltage 8 nvent.com/erico

THE CORE OF TD TECHNOLOGY The secret to nvent ERICO Transient Discriminating Technology is its active frequency discrimination circuit. This patented device can discriminate between a temporary over-voltage (TOV) condition and a very fast transient, which is associated with lightning or switchinginduced surges. When the transient frequencies are detected, the patented Quick-Switch within TD activates to allow the robust protection to limit the incoming transient. The frequency discriminating circuit that controls the Quick-Switch helps ensure that the SPD device is immune to the effects of a sustained 50 or 60 Hz TOV. This allows the device to keep operating, in order to help provide safe and reliable transient protection, even after an abnormal over-voltage condition has occurred. Effectively, TD Technology allows the SPD to have two clamping levels one well above the peak of a TOV (up to twice its nominal AC voltage!), and the other much lower, to effectively and swiftly clamp lightning transients. As the explanatory illustration shows, this allows the TD circuit to still remain operational after TOV events, thus continuing to clamp transients and providing a much longer operational life. For example, the IEC 61643-11 standard applies a test of 442 Vac from Line to Neutral for filters with an operating voltage of 230 Vac. While the filter may fail safely during this test, the N-Series SRFs are unaffected by this stringent test, and remain completely operational. The SRF N-Series (incorporating TD Technology) is especially recommended for any site where sustained over-voltages are known to occur, and where failure of traditional SPD technologies cannot be tolerated. TRADITIONAL TECHNOLOGY Thermal Disconnector ACTIVE TD TECHNOLOGY Thermal Disconnector TD Quick Switch TRADITIONAL TECHNOLOGY RESPONSE Until replaced, further surges go unimpeded straight to the equipment to be protected! Traditional SPD, at best, disconnects safely during TOV event. TYPICAL SUPPLY PROBLEMS 1. Transient Impulse 2. Substantial Over-voltage 1. Transient Impulse Traditional SPD voltage clamping TD TECHNOLOGY SOLUTION TD Technology clamps time after time! TD technology clamping nvent.com/erico 9

Combining Technologies Into The Ultimate AC Surge Protector DEVELOPMENT OF SURGE REDUCTION FILTERS nvent ERICO strives to employ the most suitable technology for each application across its range of SPDs, including high performance Surge Reduction Filters (SRFs). The N-Series Surge Reduction Filters are the most recent development of a proud pioneering history of surge reduction filters design, and now feature IEC Standards compliance. kv 6 kv V(t) THE KEY BENEFITS OF COMBINED TSG & TD TECHNOLOGY ARRIVAL OF SURGE PRIMARY DIVERSION STAGE RESIDUAL WAVEFRONT Risetime = 1.2 μs 50 μs Input surge typically up to 6 kv and 500 μs duration. μs kv Approx. 2 kv 1-2 μs μs Primary diverter stage clamps surge to approx 2 kv and the duration to 1-2 μs. kv dv/dt lower 270-350 V V lower Filter stage slows wavefront and dramatically reduces destructive dv/dt. μs FUNDAMENTAL BREAKTHROUGH IN FILTER DESIGN Incorporating Spark Gap Technology into a surge reduction filter has allowed a fundamental breakthrough in the overall design of the filter. Iron powder cored inductors, which are much smaller than non-saturating air-cored inductors required in MOV based surge reduction filters, have been used in the nvent ERICO Critec brand of SRF. Incoming surge on power line Primary Diverter (SG) - diverts excess energy to ground Inductor - slows rate of voltage rise Capacitor TD Quick Switch Secondary Diverter (TD) - further reduces excess energy The use of iron cored inductors is possible because the let-through voltage from a Spark Gap remains high for only a few microseconds. In comparison, the letthrough voltage from a MOV based device remains between 600 V and 1000 V for the duration of the surge. This time can range up to 500 microseconds for long tail pulses and determines how much energy the inductor will have to store before reaching saturation and becoming ineffective. The secondary TD Technology diverter adds additional protection, and is particularly useful for clamping transients generated within the facility. The let-through voltage for a MOV based diverter remains at 600 V - 1 kv for up to 500 μs. This determines how much energy the inductor must store before becoming saturated. kv 600 V - 1 kv Up to 500 μs Ground μs The efficient clamping of the SG occurs in only 1-2 μs. This allows a smaller, more efficient inductor to be utilized, greatly reducing the size and weight of the filter, in addition to providing improved all-around performance. 10 nvent.com/erico

WHAT BENEFITS FLOW FROM THIS TECHNOLOGY? The combination of Spark Gaps and series filtering provides the benefits of high surge capability, low let-through voltage and considerably reduced rate of voltage rise (dv/dt). Additional benefits of reduced size, weight and heat dissipation also result. In keeping with the role of the SRF N-Series to protect highly critical facilities, the design of these filters has been simplified to feature direct connection from input to output. Avoiding unnecessary series overcurrent protection improves the overall reliability of the system. Overall operational status can be determined from the front door indication LED. Further LEDs within the unit identity the correct functioning of the individual surge protection elements. Remote indication of the status is easily accomplished by connection to the remote status relay contacts within the unit. THE IEC 61643-11 SURGE PROTECTIVE DEVICES STANDARD This standard (previously IEC61643-1) is the international standard for testing of surge protection devices (SPDs). It has evolved over the years to become the benchmark for ensuring performance and safety of SPDs. The SRF N-Series is in complete compliance with the latest version of this standard, and a Declaration of Conformity is available. The standard mandates severe tests for safety and performance, testing such aspects of the SPD s ability to withstand multiple standardized surge impulses, measurement of the voltage clamping level of the SPD to those surges, safe behavior during various failure mode simulations, and sustained TOV situations. In addition, series connected devices, such as the SRF N-Series, are put through load current tests at the rated load current, and also at severe overload currents to ensure safety and correct functioning. Finally, the filters are tested on AC supplies able to deliver the full rated prospective short circuit current for safe behavior during various internal short circuits and even short circuits across the output terminals. Some manufacturers resist testing to this standard because it is difficult to pass. Our product compliance is your assurance for safe and reliable site protection. nvent.com/erico 11

Surge Reduction Filter N-Series, Single Phase FEATURES High-performance protection incorporating Spark Gap and Transient Discriminating (TD) technologies High surge rating ideal for exposed critical service entrance applications Reduces let-through voltages and rate-of-voltage rise (dv/dt) and helps provide optimum protection for electronic equipment Extreme reliability and simplified design with direct connection from input to output Comprehensive front panel status and internal diagnostic LEDs H D W SPECIFICATION Part Number SRF163N SRF1125N Nominal System Voltage (Un) 220-240 VAC Distribution System System Compatibility 1Ph 2W+G TN-C TN-C-S TN-S TT Rated Load Current (IL) 63 A 125 A Frequency Short Circuit Current Rating (SCCR) Heat Dissipation 50 60 Hz 43 ka 25 W Rate of Voltage Rise (dv/dt) 3 V/µs Max 8 V/µs Max Filtering -40 db @ 100 khz Input Connection 10-35 mm² 25-120 mm² Output Connection Protection Modes Technology Enclosure Material 25-120 mm² All modes protected Spark Gap In-line series low pass sine wave filter TD technology with thermal disconnect Metal Enclosure Rating IP 65 12 nvent.com/erico

Part Number SRF163N SRF1125N Mounting Wall mount Part Number SRF163N SRF1125N Status Indication Depth (D) Height (H) Width (W) Front panel LED Internal diagnostic primary and secondary protection LEDs Change-over contact (Form C dry), 250 VAC/30 VDC/5 A, 4 kv isolation 200 mm 300 mm 400 mm Unit Weight 10.3 kg 12.3 kg Complies With IEC 61643-11 Class I, Class II ANSI /IEEE C62.41.2-2002 Cat A, Cat B, Cat C ANSI /IEEE C62.41.2-2002 Scenario II, Exposure 3, 100 ka 8/20 μs, S10 ka 10/350 μs AS1768 Ratings Part Number SRF163N SRF1125N Max Continuous Operating Voltage Maximum Surge Current, L-N Maximum Surge Current, N-PE Voltage Protection Level, L-N 310 VAC 130 ka 8/20 μs 50 ka 10/350 μs 130 ka 8/20 μs 50 ka 10/350 μs 150 V @ 3 ka 8/20 μs 200 V @ 20 ka 8/20 μs 250 V @ 3 ka 8/20 μs 350 V @ 20 ka 8/20 μs IEC 61643-11 Ratings Part Number SRF163N SRF1125N Max Continuous Operating Voltage (Uc) 255 VAC Temporary Overvoltage, L-N 442 VAC 2 hours Temporary Overvoltage, N-PE 1200 VAC 200 ms Impulse Current (Iimp) 10kA 10/350 μs Voltage Protection level (Up), L-N @ Iimp 450 V Nominal Discharge Current (In) 20kA 8/20 μs Voltage Protection level (Up), L-N @ In 450 V 500 V Voltage Drop 0.1 % Max IEC 61643-11 Annex A specifies Max Continuous Operating Voltage (Uc) as 255 VAC. IEC 61643-11 test procedure limits maximum Impulse Current (Iimp) to 10kA due to internal product safety fusing. IEC 61643-11 recommends a maximum preferred value for Nominal Discharge Current (In) of 20 ka. IEC 61643-11 Temporary Overvoltage tests are passed in withstand mode. Upstream overcurrent protection not exceeding Rated Load Current (IL) shown above must be installed ahead of the surge reduction filter. nvent.com/erico 13

Surge Reduction Filter N-Series, Three Phase FEATURES High-performance protection incorporating Spark Gap and Transient Discriminating (TD) technologies High surge rating ideal for exposed critical service entrance applications Reduces let-through voltages and rate-of-voltage rise (dv/dt) and helps provide optimum protection for electronic equipment Extreme reliability and simplified design with direct connection from input to output Comprehensive front panel status and internal diagnostic LEDs H D W SPECIFICATION Part Number SRF363N SRF3125N SRF3250N SRF3500N SRF3800N Nominal System Voltage (Un) 220/380-240/415 VAC Distribution System 3Ph Y 4W+G System Compatibility TN-C TN-C-S TN-S TT Rated Load Current (IL) 63 A 125 A 250 A 500 A 800 A Frequency 50 60 Hz Short Circuit Current Rating (SCCR) 43 ka Heat Dissipation 34 W 56 W 98 W 215 W 260 W Rate of Voltage Rise (dv/dt) 5 V/µs Max 10 V/µs Max 11 V/µs Max 10 V/µs Max Filtering -40 db @ 100 khz Input Connection 10-35 mm² 25-120 mm² 10 mm Stud (2) 10 mm studs Output Connection 10-35 mm² 25-120 mm² 10 mm Stud (2) 10 mm studs Protection Modes Technology Enclosure Material All modes protected Spark Gap In-line series low pass sine wave filter TD technology with thermal disconnect Metal 14 nvent.com/erico

Part Number SRF363N SRF3125N SRF3250N SRF3500N SRF3800N Enclosure Rating IP 65 IP 32 Mounting Status Indication Wall mount Front panel LED Internal diagnostic primary and secondary protection LEDs Change-over contact (Form C dry), 250 VAC/30 VDC/5 A, 4 kv isolation Depth (D) 200 mm 300 mm Height (H) 500 mm 800 mm 1,000 mm 1,200 mm Width (W) 400 mm 600 mm 800 mm Unit Weight 17.7 kg 21.6 kg 41.7 kg 76.6 kg 97.2 kg Complies With IEC 61643-11 Class I, Class II ANSI /IEEE C62.41.2-2002 Cat A, Cat B, Cat C ANSI /IEEE C62.41.2-2002 Scenario II, Exposure 3, 100 ka 8/20 μs, 10 ka 10/350 μs AS1768 Ratings Part Number SRF363N SRF3125N SRF3250N SRF3500N SRF3800N Max Continuous Operating Voltage Maximum Surge Current, L-N Maximum Surge Current, N-PE Voltage Protection Level (L-N) 310 VAC 130 ka 8/20 μs 50 ka 10/350 μs 130 ka 8/20 μs 50 ka 10/350 μs 200 V @ 3 ka 8/20 μs 250 V @ 20 ka 8/20 μs 300 V @ 3 ka 8/20 μs 380 V @ 20 ka 8/20 μs 300 V @ 3 ka 8/20 μs 500 V @ 20 ka 8/20 μs 300 V @ 3 ka 8/20 μs 550 V @ 20 ka 8/20 μs 300 V @ 3 ka 8/20 μs 550 V @ 20 ka 8/20 μs IEC 61643-11 Ratings Part Number SRF363N SRF3125N SRF3250N SRF3500N SRF3800N Max Continuous Operating Voltage (Uc) Temporary Overvoltage, L-N Temporary Overvoltage, N-PE Impulse Current (Iimp) Voltage Protection level (Up), L-N @ Iimp Nominal Discharge Current (In) Voltage Protection level (Up), L-N @ In 255 VAC 442 VAC 2 hours 1200 VAC 200 ms 10kA 10/350 μs 450 V 500 V 550 V 20kA 8/20 μs Voltage Drop 0.1 % Max 450 V 500 V 650 V IEC 61643-11 Annex A specifies Max Continuous Operating Voltage (Uc) as 255 VAC. IEC 61643-11 test procedure limits maximum Impulse Current (Iimp) to 10kA due to internal product safety fusing. IEC 61643-11 recommends a maximum preferred value for Nominal Discharge Current (In) of 20 ka. IEC 61643-11 Temporary Overvoltage tests are passed in withstand mode. Upstream overcurrent protection not exceeding Rated Load Current (IL) shown above must be installed ahead of the surge reduction filter. nvent.com/erico 15

Our powerful portfolio of brands: CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER nvent.com/erico WARNING: nvent products shall be installed and used only as indicated in nvent s product instruction sheets and training materials. Instruction sheets are available at nvent.com/erico and from your nvent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nvent s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. 2018 nvent. All nvent marks and logos are owned or licensed by nvent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nvent reserves the right to change specifications without notice. Erico-SB-E1289B-E139LT17WWEN-EN-1805