controls Installation and Maintenance Smart S Twin Fan Control System Used with Quietwin fans Year Warranty *12 Year Warranty (UK only) Introduction

Similar documents
Installation and Maintenance Microsave Twinfan Control System

Off/Fail. LED display

MAINS DISTRIBUTION UNIT MDU14-CO

Product Data Sheet. Hochiki 8 Way I/O Card. Features

The Diplomat Range. User Manual. PIN & CAM Models. Date: September 2015 Version: 1 LPL15_V1_05

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Warning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Operating Instructions

Operating and Maintenance Instructions

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

Installation & Operation Guide

LASERMET LS-20 INSTRUCTION MANUAL

Operating Instructions

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Operating Instructions

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

The indigowall. User Manual. 2 of 2. Date: June 2016 Version: 1 LPL16_V1_02

Non-communicating room controllers

Installation and Setting up Instructions for the Type 920 Auto Sequencer

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Fast Route to Reliable Energy Savings ZIP Economizer

Channel Switch CS. General Operating, Maintenance and Installation Manual

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

InBin-P Pressure switches from 5 Pa Pa

LASERMET ULTRA LED SIGNS INSTRUCTION MANUAL. Single Aspect Illuminated Sign LEDS-ULT-790

MAXIMA + Series ROTARY LEVEL CONTROL

OP10. Pre-programmed, configurable controller for simple applications

Super universal modules

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

Quick Start Guide and Health and Safety Information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Immersion Temperature Sensors

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Installation Instructions

Resistance measuring module

Digital Thermostat for drum heaters Model HCL 5536

EHS INC. Electric Heating Systems, Inc. 109 North Gold Drive Robbinsville, NJ Phone: (609) Fax: (609)

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Non-communicating room controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

SX90 Process Controller

Version 2. Inline Relay (500W) Model No. LW821. Instruction Manual. Connect Series.

4100 and 4100/R Controllers

HEC. General Operating, Maintenance and Installation Manual

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Overview of types. Technical data

Installation & Operation and Maintenance

Sigma XT Ancillary Board (K588)

Tallyman Controller Quick Configuration Manual

TECHNICAL MANUAL PRESSURE TRANSDUCER TYPE MLP

INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual

Temperature controller Ducted systems

Synergy - Applications and Use

CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Pre-programmed room controller with display and communication

Artistic Licence. Net-Lynx O/P. User Guide. Net-Lynx O/P User Guide. Version 1-5

Instruction and Operation Manual

MAXIMA + Series ROTARY LEVEL CONTROL

Installation Guide Controller Series E130/E230/E430

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

Sollatek SVS Range Voltage Stabilisers User Manual

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

Versatile Safety Interlock Switch with Guard Door Locking

Ecotel Free Cool 5-15kW

PNEUMATIC CRIMPER PC 12-8B OPERATING MANUAL

Functional data Factory settings Variable Setting Torque Inhibiting torque

Instruction Manual. T3110 T3110L T3110Ex

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

TRC-190 User s Manual

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Room unit with PPS2 interface

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

SMARTSCAN INFORMATION

45A Cooker Switches. 45A Cooker Switches

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

660/960 Installation Guide

Product Data Sheet. BMS/Graphics Interface. Features

M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

PIR Movement Sensor. Instruction Manual. Connect Series. Model No. JSJSLW107. Version 2

Content. Product Description

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights.

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Supplementary operating instructions for your air curtain system Controller TMC 500

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

FCU-4 FAN COIL CONTROLLER

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

STRA-17 Room controller. Installation and maintenance manual. Content

Transcription:

Smart S Twin Fan Control System Used with Quietwin fans Installation and Maintenance NuAire Limited Western Industrial Estate Caerphilly, Mid Glamorgan CF83 1XH United Kingdom Telephone 01222 885911 Facsimile No. 01222 887033 Email: info @ nuaire. co.uk Leaflet No. 670963 FEBRUARY 1999 Introduction controls Contents Page Introduction 1 Note: This information is general and the specific fan Installation & Maintenance leaflet supplied with each Quietwin unit should be referred to when setting up and commissioning. If required, replacement leaflets for any Quietwin unit are available on request from the NuAire Technical Library Tel: 01222 858231 Smart control wiring to twinfan 2 Control module input connections 3 Commissioning 3 DIL switch settings 4 Adding sensors etc 4 Certification 5 The NuAire Smart S Twinfan Control system brings a totally new concept to twinfan control technology. Low voltage circuitry and wiring is employed between the fan and the plug in sensors and remote controls. The low voltage 4 -core connecting cables can be installed without the use of expensive and unsightly housing conduits. The twinfan is fitted with an integral control module which is connected via low voltage cables to the sensors and remote controls selected. All the mains supply and switching is housed in the control module located at the Quietwin fan unit. Quietwin fans with the Smart S control option are available in models suitable for internal (QTI & QTE) and external (QTE& QTR) applications. Internal QTI units have their Smart control module mounted on the exterior sidewall of the casing. Note that for weathering purposes the exterior (QTE & QTR) units have the main Smart control module mounted internally but feature a small exterior commissioning box located on the outside of the case to allow speed and run on time etc. to be adjusted without removing the fans top cover. Smart systems can be as simple or as comprehensive as the customer wishes to suit your specific application. Our Controls Application Service is ready to advise on your enquiry. Controls Application Service (CAS) A team of Engineers and technicians is available to provide pre and post order support. We are on hand to provide help and advice from the most basic use of any NuAire equipment to the more complex applications, maximising on the versatility of our SMART and NetLink control products. Telephone: 01222 858585 Facsimile: 01222 858586 QUIETWIN WARRANTY (Smart Controls) *12 Year Warranty (UK only) 12 Year Warranty The 12 year warranty starts from the date of delivery and includes parts and labour for the first year. The labour element is subject to full, free and safe access to the equipment as recommended by the CDM regulations. The remaining 11 years covers replacement parts only. * Only available on Quietwin when used with Smart Control linked to PIR Sensors. Installation must be registered with NuAire by completing the form provided in the fan unit Installation & Maintenance leaflet. Your Quietwin fan Installation & Maintenance leaflet incorporates a warranty registration form. Please fill in the form and return to NuAire Service Department at the address below. Western Industrial Estate, Caerphilly, Mid Glam CF83 1XH United Kingdom. Tel: 01222 885911 Fax: 01222 887033, Email: info@nuaire.co.uk 1

Smart S TWINFAN CTROL Fig. 1. Control module location on a QTI internal use Quietwin Smart Control module 230v Mains to Twinfan Connecting unit to the mains 230v supply Remove the control module cover (4 nylon fixings) Unscrew and remove the aluminium terminal cover plate, Feed the mains cable through the rubber grommet and connect your 230v supply to the terminals marked MAINS (See fig. 2). Step Button manually steps through functions Optional Sensors & Timeclocks etc. plug in here Master on/off control input Sensor input Sensor input Remote fail sensor input DIL switches (used to tailor smart twin operation) NOT USED INPUT 4 INPUT 3 INPUT 2 INPUT 1 RD YL GN BL RD YL GN BL Step button Fan 1 Fan 2 AUTO Fuse (fans) Fuse (control) Fuse (dampers) MAINS DAMPER 1 DAMPER 2 SW FAIL LIVE SW N L OP CL RET OP CL RET SL FAIL Volt Free Contacts for fail indication 240v live from light switch (fan operates when live) 240v live to close 240v live to open 240v live to close 240v live to open 240v mains supply Damper switch conn. Remove links when using dampers fitted with limit switches Fig. 2. Control module connection details Adjustment Adjustment (see commissioning procedure) Smart Control wiring to Twinfan Figure 2 above shows the inside of the case mounted Smart Control Module. All sensors and user controls / timeclock etc are plugged in to the control module circuit board. Terminal connection strip is located on the right of the board. Note the mains connection terminals. Options List of available sensors, user controls and ancillaries for S" option users with a reference to corresponding information leaflets COMPREHENSIVE SMART SYSTEM Smart Twinfan (typical) Extract from toilet '1' (e.g. FEMALE) Airflow Direction Box Code: ST-ADB 10 Extract from toilet '2' (e.g. MALE) 1 2 3 PIR Occupancy sensor, code: ST-PIR (Leaflet No: 670864) Humidity sensor, code:st-hum (Leaflet No: 670865) Audio / visual fail indicator, code:st-avi (Leaflet No: 670877) 4 Timeclock on / off, code: ST-TC (Leaflet No: 670866) Junction Box Code: ST-JB 6 11 230v mains supply Up to four devices can directly "plug in" to the Smart Control 9 BMS System interface Code: ST-BMS To B.M.S. 5 6 Manual user control, code ST-MAN Junction Box, code: ST-JB 1 2 3 4 5 P.I.R. Occupancy Sensor Code: ST-PIR Humidity Sensor Code: ST-HUM To up to six additional sensors (if required) Audio / Visual Fail Indicator Code: ST-AVI 7 Sensor Guard Timeclock / Code: ST-TC Manual User Control / Code: ST-MAN MK Adaptor plate Code: MK-ADAPTOR Control 8 MK Box (not supplied) 7 8 9 10 11 Sensor guard, code: refer to Nuaire MK Adaptor plate, code:: MK ADAPTOR BMS Interface, code:st-bms (Leaflet No: 6708697) Airflow direction box, code: ST-ADB Low voltage comms cable 10m length 2 Fig. 3. Quietwin system showing additional options. QTI fan illustrated.

Smart S TWINFAN CTROL Control Module Connections /Inputs and their uses (see fig 2) SENSOR INPUT 1: This is the Master on/off control input and is usually linked out with a special plug unless: A Timeclock can be connected into this input e.g. ST-TC During times the unit is allowed to operate. During times the unit is off- zero duty. Note: The ST-TC Timeclock must always be plugged into the fan mounted control module NOT into a ST-JB junction box. SENSOR INPUTS 2, 3 & 4 Any sensor can be connected to these inputs to allow activation of the unit. If any of these inputs is activated, the unit will run at the maximum set duty. These sensors include ST-PIR, ST-HUM, ST-TEMP. Note: Additional sensors may be added by using an ST-JB Junction Box. SWITCH LIVE terminals This acts just like the sensor inputs 2,3,4. If 230v ac is detected on the SW - Live terminals, the unit will run at the max. set duty DAMPER terminals (2 sets) When the fan is running at full duty, both these damper connections will be activated. i.e. power will be available on the OP terminals of the damper connections. The fan will not go to full duty until the RET terminals have 230v ac (Limit Switch). FAILURE RELAY This relay is normally closed when there are no faults. When faults occur this relay will open and break the circuit. This method of operation allows all types of failure to be detected for example Power failed, Fan/s fail. This connection is a volt free switch. it can handle power up to 5A (230v) and is fused for protection. NO FAULT: FAN FAULT: The volt free switch is closed i.e. the two terminals are connected. The volt free switch is opened. i.e. the two terminals are disconnected. Using the Step button (see fig 2). Refer to the label on the controls inside cover for more guidance. Pressing the step button will sequence through the options and change the modes as follows: Commissioning Procedure (see fig. 2). 1. Switch on the supply to the QTI Quietwin fan. 2. Locate the control module panel Care must be taken if the module has any covering panels removed as live 230v incoming supply terminals may be exposed. Note covers MUST be properly replaced when commission ing has been completed. 3. Wait approximately 60 seconds for the system to complete its self test 4. Press the step sequencing button several times until only the FAN 1 light is illuminated and the AUTO light is off. (See detail of control panel Fig. 2). 5. Connect a manometer across the tappings provided on the outside of the fan casing. Reading the manometer and using the graph, determine the airflow. The fan is factory set at full speed. Using the rotary graduated control,reduce the speed to the desired setting (may require a screwdriver). NOTE: allow 30 seconds for the fan to reach the set speed. 6. Set the timer control. (Adjustable 5-60 min). (See detail of control panel Fig. 2). 7. Press the step button through the sequence until AUTO light shows. COMMISSIING IS NOW COMPLETE. Using the graphs (SPECIFIC GRAPHS FOR YOUR QUIETWIN FAN ARE SHOWN IN THE FAN INSTALLATI & MAINTENANCE LEAFLET). The graphs are designed to assist you in establishing an AIR VOLUME FLOW RATE for your fan installation. The curves shown indicate performance at 100%, 75% and 50%. Assuming that the ventilation system is installed and the fan is connected to all ductwork. Connect a manometer across the tappings provided on the outside of the fan unit casing. The fan is factory set for full speed. With the fan operating at this full speed (100%) take a pressure reading in Pa from the manometer. Refer to the relevant graph for your size of unit and with your Pa figure, read across the graph to where the line intersects the 100% curve. Drop a line vertically down from this point and the air volume flow is indicated on the base line of the graph. See the fan Installation & Maintenance leaflet supplied. 1. FAN 1 in manual mode (used for commissioning) 2. FAN 2 in manual mode (used for commissioning) 3. SYSTEM 4. SYSTEM IN AUTOMATIC (normal selection) To clear a fail, press the STEP button until the fail has cleared. IMPORTANT After commissioning, press the STEP button through until AUTO is illuminated. System is now in automatic mode. EXTERNAL USE QUIETWINS WITH THE SMART CTROL OPTI ARE PROVIDED WITH A COM- MISSIING BOX THE OUTSIDE OF THE CASE The main control module is inside the fan (See fig 5). Fig. 4. A typical Quietwin graph 3

Smart S TWINFAN CTROL These controls located inside commissioning box (External use 'S' control option units only) Commissioning box on outside of case ('S' control external use unit only). Step button Fan 1 Fan 2 AUTO Mains Supply and Sensor(s) to Control Module inside fan. Mains Supply P.I.R. Sensor Step Button manually steps through functions QTE & QTR external use Quietwins with SMART S control option. The essential control difference with these fans is that they have the main control module inside the fan case. A small commissioning box is provided on the outside of the case which contains the essential commissioning control buttons i.e. The STEP button and the run on and speed adjustment controls. Figure 5 shows a typical QTR Quietwin and the details of the customers commissioning box. Commissioning procedure is the same as that shown on page 3 for the internal use units. Adjustment Adjustment (see commissioning procedure) Fig. 5. Exterior commissioning control box panel. Smart Twinfan DIL switch settings (see fig 2). The Smart Twins operation can be individually tailored to suit your own particular application. 30% TRICKLE SPEED A label is attached to the inside of the control module cover detailing the various switch functions. 40% TRICKLE SPEED Refer also to switch settings shown opposite. DEFAULT MODE: The fan runs in trickle mode until the toilet is occupied Switch 1 & Switch 2...Trickle mode and rate 50% TRICKLE SPEED NO TRICKLE SPEED Switch 3...2 way Damper Box fitted = Damper Box fitted (split duty system) = No Damper Box fitted AIRFLOW DIRECTI BOX FITTED Adding Sensors & Controls Refer to page 2 of this leaflet for a list of sensors and user controls which are available for use with the Smart controlled Quietwin fans. Sensors and user controls etc are supplied complete with specific installation details. Additional general sales information on these optional ancillaries is shown in the NuAire TWINFANS Sales / Technical brochure (Leaflet No 670808) available on request from the NuAire Technical Library Tel: 01222 858231. 4

DECLARATI OF CFORMITY NuAire Limited, Western Industrial Estate, Caerphilly, Mid Glamorgan, CF83 1XH. United Kingdom. Telephone: 01222 885911 Fax: 01222 887033 Email: info @ nuaire. co. uk OCTOBER 1998 We declare that the equipment named below conforms to the requirements of EC Council Directive relating to Electromagnetic Compatibility Designation of equipment :- TWINFAN CTROL Equipment Types :- SMART (S) Relevant EC Council Directives :- 89/336/EEC, 92/31/EEC (EMC) Applied Harmonised Standards :- E50081-1, EN50082-1 Basis of Self Attestation :- Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No. FM 149 Signature of manufacture representatives :- Name: Position: Date: 1) C. Biggs Technical Director 2. 10. 98 2) M. Fussell Manufacturing Director 2. 10. 98 5

Smart S TWINFAN CTROL Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right is reserved to make such changes without prior notice. Western Industrial Estate, Caerphilly, Mid Glam CF83 1XH United Kingdom. Telephone: 01222 885911 Facsimile: 01222 887033, Email: info@nuaire.co.uk Leaflet No. 670963 6