IDM DATA ACQUISITION SYSTEM

Similar documents
Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

TFS 2100 Traveling Wave Fault Location System

Power Transmission and Distribution. I m on guard here! SIMEAS R reports power system weaknesses quickly and accurately

Power System Monitoring Recorder TESLA 3000

Power System Monitoring Recorder

SM100. On-Line Switchgear Condition Monitoring

Power System Monitoring Recorder. Product Overview. 10 Year WARRANTY

MINER-S Station Controller. Substation Automation

Bus Bar Protection Relay B-PRO 4000

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

Chapter 2 State Estimation and Visualization

MINER-S Station Controller

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control

Multilin P30 Phasor Data Concentrator

Transformer Protection Relay

GRID/PRSHT/MU320/EN/1.2014/GBR/1894 ALSTOM All rights reserved.

Scout-S Station Controller

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

MW/MVAR Transducer Specifications

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

PRICOM Power Communication and Control Systems

6220 Ethernet-Based Voltage Measurement Module

Three-Phase Power Quality Analyzer PowerPad Model 3945

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit

metrum PQ 110 Power Quality Unit, Class A Normative reference instrument for MV substation monitoring

SCADA. SurvalentONE. STC Explorer

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

SEL Real-Time Automation Controller (RTAC)

KOCOS - THE TECHNOLOG Y GROUP WHERE PRECISION MEET S QUALIT Y SHERLOG CRX. Fault Recorder Systems KOCOS MESSTECHNIK AG [ ENG ]

Discover. BlackBox G4400. Outstanding Features. Designed for Your Needs. PQZIP Compression Technology. Elspec s Unique Technology

A P P L I C A T I O N

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

extending the boundaries of technology evolution of proven technology FEATURES

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.

TFS-2100E Travelling Wave Fault Locator System Description and Specification

Remote Terminal Unit ER1000 APPLICATION FEATURES

TWFL - Travelling Wave Fault Location System

TR-2100 Multi - Function Recorder

PMC 530 Series Advanced Multifunction Meter

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

EPPE CX PX. Power Quality Analyser K O C O S M E S S T E C H N I K A G [ENG ]

SCE WASAS Combined Disturbance Fault Recorder (DFR) and Phasor Measurement Unit (PMU) Specifications. Anthony Johnson

ROCON RPC 116. SUBSTATION AUTOMATION Central unit for substation automation

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

Real-time Power System Operation. Energy Management Systems. Introduction

PowerFactory Monitor PFM300

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Your technology partner Datakom, innovative products, affordable prices.

Electrical multifunction analysers

High-speed transformer differential protection for up to five terminals

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

CBA 1000 CHARACTERISTICS

GE Multilin 350 Feeder Protection Relay Specifications

A low-cost, economical solution for distribution feeder protection

A2000 Multifunctional Power Meter

NTX Series Product Comparison

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Blackout 101. Dr. B. Don Russell Texas A&M University. Dr. Bruce Wollenberg University of Minnesota. Mr. John McDonald KEMA, Inc.

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Product Description. S&C IntelliNode Interface Module. Table of Contents. Instruction Sheet

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Development Of EMCS In Power Plants

NF760 Batch Controller

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

THE INTEGRATED TESTING SOLUTION

APR64(Rackable) APR64P (Portable)

Multifunction Transducer MT440

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

GRD130 - FEATURES APPLICATION

Ovation Ethernet Link Controller Module Data Sheet

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

A2000 Multifunctional Power Meter Profibus Interface

MIC-2 Multi-instrument DATA SHEET

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

g GE Power Management UR - The Universal Relay

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Protection Relays PHASE & RESIDUAL OVERCURRENT

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

CBA HV Circuit Breaker Analyzer and Microhmmeter

UPLC-100. Universal Power Line Carrier. 5C Communications Inc.

Advanced distribution feeder solution with integrated protection, monitoring, and control

Operators Manual. for Model 2002 Multifunction DFR/SER and Model 3002 SER. Version Revision 0. Date: 1/25/13

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

SCADA and Central Applications An introduction

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

VersaMax Micro and Nano Technical Product Presentation

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

S&C 6801M Automatic Switch Operator

Control and Protection System Win-TDC

Transcription:

DATA ACQUISITION SYSTEM

The a compact and economical multifunction data acquisition system Rendering all Unrivalled product profile Advanced multifunctional distributed data acquisition system Fully multitasking operation system - VxWorks Supports multiple concurrent applications Flexible network communications - fibre and twisted pair Ethernet (TCP/IP) and with conventional modems (PPP) Replay Plus Master Station configuration and analysis software High performance Replay Plus software Full communications, configuration display and analysis Record viewer and printing Real time phasors Powerful analysis tools Interface to Microsoft Access database - user configurable record analysis Compatible with existing installed base of DFR IIs other systems obsolete State of the art technology Powerful 16/32 bit micro-controller 16-bit analog resolution 16Mb of memory 10Mbit/s Ethernet network Integral DSP processor Surface mount technology throughout Internet communications A true multifunction device Fault location and fault recording Disturbance recording Transient and continuous slow scan Power quality recording Power system stability monitoring Sequence of events recording Quality of supply monitoring Measurement functions Circuit breaker monitoring Technical Overview Introduction The is a distributed multifunctional data acquisition system designed to address the data recording requirements of a modern distribution or transmission substation. The product, when coupled with Replay Plus, a Master Station software package, provides a powerful platform for the acquisition, analysis and reporting of data from power system substations. In addition to the fault and disturbance recording capabilities of the, upgrades incorporate the following functions: Power system monitoring (triggered and continuous recording) Phasor measurement Event recording / power quality recording Equipment condition monitoring SCADA I/O Each of these functions operates completely independently from any other function within the and the use of an industry standard multitasking operating system provides added security. Individual Data Acquisition Units (s) are networked on a twisted pair or fibre optic Ethernet LAN using TCP/IP protocol for communications. PC based Local Storage Units can be added to the LAN to provide mass storage and Windows Master Stations can also be added to provide local analysis capabilities. This network can be connected directly to wide area networks or can be accessed directly using industry standard dial-up networking. The architecture of the and the use of TCP/IP in the communications software allows direct connection to the Internet. The s can be synchronised to 1µs using an internal or external GPS clock and this provides synchronous sampling in all s with the ability to make system wide phasor measurements. Installation Each is equipped with a powerful 16-bit processor, DSP processor, 16-bit A/D converter and 16Mb of memory. This provides sufficient processing power to carry out data acquisition on all analog inputs and to compute in real time watts, vars, sequence components and phasor quantities for up to three lines. These quantities are calculated on a cycle by cycle basis and the values are time-tagged to a resolution of 1µs. s are available in two formats: A 3U model with 10 analog channels and 16 or 32 events A 6U model with 16 analog channels and 32 events All signal conditioning is internal and the s are designed to be installed in the relay panels associated with the circuits being monitored; the 3U can be used to monitor up to two circuits if a common set of voltages is available. Each can calculate the neutral current from the phase currents eliminating the need to dedicate a channel to recording neutral current.

Unequalled price and performance...the future of data acquisition today Fault and Disturbance Recording The fault recording function records all primary analog quantities at sample rates of up to 6.4kHz (7.68kHz on 60Hz systems) and can be triggered on under and / or over level, or rate of change of any primary or calculated quantity. Calculated quantities include negative and zero sequence voltages and currents, frequency, harmonics, watts and vars. In addition to the conventional fault record, which is typically one or two seconds long, each can simultaneously record up to eight channels of transient slow scan data around the time of the fault recorder trigger. This data can be sampled at 10/12Hz or 50/60Hz and up to thirty minutes of data can be recorded. This information can be used to analyse the response of the power system before, during and after real system faults. Event Recording The event recording function within the will capture and time-tag all changes of state on the event inputs. This data can then be output to a local printer in a similar format to a conventional event recorder or transferred as a data file to a remote Master Station. Power System Monitoring More sophisticated triggering and longer duration recording of power system disturbances is provided by the power system monitoring function. For this application a Local Storage Unit or PC is attached to the LAN to provide the mass storage required for storing the volume of data generated by this type of recording. Each can calculate a number of power system quantities for each of the lines being monitored on a cycle by cycle basis. Rear Panel showing Extensive Connections Each measurement is accompanied by a time-tag with a resolution of 1µs giving, in the case of phasors, system wide phase information accurate to less than 0.5 degrees. The data for each of these quantities is transferred on a continuous basis to the LSU or PC on the network. Data is stored here in a cyclic buffer on the hard disk for a period of up to 30 days and may be transferred to a remote location at any time without interrupting the recording process. In this way a continuous history of the power system is recorded and saved for later analysis when required. Triggering algorithms are provided in the LSU that can detect step changes or oscillatory transients on calculated power (real and reactive), voltage and frequency signals. When a trigger condition is detected a trigger message is sent to the Master Station. The Master Station can then be configured to automatically retrieve data in one or more user defined Profiles. Real Time Phasors In addition to recording power system quantities, the has the capability to provide real time phasor information to remote locations. The ability to transfer real time phasor information from a number of locations on a power network to a central point provides a source of data for developing an application to provide real time power system stability information. Power Quality Recording The can be programmed to take measurements of the supply voltage at regular intervals. The quantities calculated and recorded include RMS voltage, harmonic content, frequency, sequence components, etc. The power quality function will also capture and record the magnitude and duration of voltage dips caused by faults and other system incidents. This data is stored in a database in the recorder and can be transferred automatically to a remote Master Station for subsequent analysis. SCADA I/O * The SCADA I/O function can be used to eliminate transducers and provide measurement information over a serial connection to an intelligent RTU using the Modbus protocol. Replay Plus Master Station Substation Monitoring with the Network Printer Ethernet Network (Fibre or Twisted Pair) Modbus (with Optional Internal GPS) LSU Modem The internal DSP in the can calculate RMS voltage and current and single and three phase power (real and reactive). In addition, this SCADA port can be used to report the status of all event inputs to the RTU. This RTU port can also be used to control secure SBO (Select Before Operate) relay outputs fitted in the distributed s. Automated Analysis of Fault Records It has long been appreciated that data from fault records has many applications in addition to the analysis of the performance of power system protection. However the extraction of data for applications such as equipment condition and power quality monitoring can be a time consuming task. Using the with the Replay Plus Master Station software automates this task and presents the resulting information in a usable format. As each record is retrieved by Replay Plus it is automatically analysed and the resulting summary parameters are stored in a database table. Analyses functions developed using Microsoft Access queries are provided for a number of applications including protection performance, equipment condition monitoring and power quality. These functions automatically process the summary information, compare calculated quantities against user specified limits and generate reports summarising the results. Alarm messages are used where immediate action is required in response to calculated results. The use of an Access database provides open access to the summary parameters and the analysis functions allowing third party support and enhancement. *The SCADA I/O feature is a new development and will require detailed discussion with users to identify specific requirements. RTU or SCADA System DFR II and Upgrade Cards LAN / WAN Connection GPS Modem IEDs /485 DFR Upgrades An upgrade package for existing Hathaway DFR IIs, based on the hardware, is available to provide the extra functionality of the. This upgrade involves changing a number of cards within the, while still retaining the original signal conditioning and isolation electronics, transforming it into a new fully integrated power system monitoring device.

Unrivalled specification with Replay Plus... the Leading 32-bit Master Station Technical Specification * Overview 10 or 16 analog, 16 or 32 event acquisition unit Relay outputs for alarms Scan rates to 7.68kHz Built in self-checking functions Analog resolution 16-bits 16Mb of DRAM Enclosure 19 x 3U x 287mm - 10 channel model. 19 x 6U x 287mm - 16 channel model. Front Panel 2 row x 16 character LCD display. Ten status LEDs. Membrane keypad. Supply Voltage 80-300Vdc and 110V or 220Vac. 24Vdc and 48Vdc models available. Relay Outputs Two alarm outputs with Form C contacts for failure alarm and operate signal. Additional 8 alarm outputs (optional). Analog Channels The 10 channel is equipped with 9 AC channels and 1 DC channel. The 16 channel has 16 AC channels with optional DC response available on all channels. Currents: 1A or 5A (nominal). Voltage: 80V or 150V. Accuracy: Better than 0.5%, CMRR >85db, phase angle error 0.5 degrees, frequency response 3db @3000Hz. Event Channels 16 or 32 event channels: Input rating 24/48V, 125V or 250V. Event circuits isolated in groups of eight (dry or wet contacts). Bipolar common (i.e. common +ve or -ve). Communications Ethernet network. TCP/IP protocol. Integral twisted pair and fibre interfaces. / RS485 port for remote communications and port for local configuration. Memory: Up to 16Mb of DRAM. Real Time Clock Can be synchronised to 50/60Hz line voltage, internal or external 1pps or GPS clock. Free running accuracy of one second per day. Printout Local printout available using a serial printer on any serial port. (s can be networked to one printer). Fault Recording Record lengths: Pre-fault time:- 50ms - 5s. Fault time:- 100ms - 5s (controlled by op limiter). Post-fault time: - 100ms - 1s. Sample rate: 32, 64 or 128 samples per cycle. 50 cycles:- 1.6kHz, 3.2kHz or 6.4kHz. 60 cycles:- 1.92kHz, 3.84kHz or 7.68kHz. Triggering: Level (over and/or under) and rate triggers on all analog channels. Settings from 5% to 95% of channel full scale. Each analog trigger has an individual operation limiter that can be set from 100ms to 5s. Analog triggering accuracy shall in all cases be better than 0.5% of channel full scale. Level triggers are equipped with hysteresis to prevent unwanted triggering. Event triggers on open, close, both or none. A user selectable event debounce (0-10ms) is provided. Negative sequence triggering, zero sequence triggering, frequency level and rate of change triggering are also provided. Frequency level triggering is under and over (i.e. Window). Settings in steps of 0.1Hz up to ±2 Hz. Level triggers will also be provided on calculated quantities such as MW, Mvar, etc. Data analysis: Record summaries, including record priority information, are stored in a separate database so that they can be retained even if records are overwritten. This database has a capacity for up to 128 summaries. Communications and configuration: Fully configurable using Replay Plus software. SER Output Data associated with changes in event inputs or operation of analog triggers is recorded and output locally or remotely in conventional SER format. *Hathaway's policy of continuous product improvement may mean that equipment supplied differs slightly from this specification. Replay Plus Replay Plus Replay Plus is a Master Station software package running on Windows 95/98 or Windows NT. It provides full configuration, data retrieval, display, analysis and printing capabilities. Predefined display screen configurations can be used to allow data to be displayed quickly in an easily interpreted format. As each record is transferred to the Replay Plus Master Station, analysis software extracts a series of parameters that can be used for later analysis. These parameters are stored in an open database, Microsoft Access, where additional software and queries can be used to perform protection performance, power quality and plant condition analysis. Data can also be transferred to third party applications using SQL. Advanced Record Display, Analysis and Manipulation Profiles and Data Retrieval Retrieval of data is controlled by the Master Station and can be carried out manually or automatically by polling. Data can also be retrieved using one of a number of user defined templates or Profiles. These can be used to retrieve data around a specified time (e.g. a trigger time) with the data retrieved coming from user selected channels on one or more s. As a result of a trigger detected by one, data can be automatically retrieved from both ends of a number of transmission lines and stored in one or more record files. Tightly integrated, powerful 32-bit Windows 95/98/NT application Supports DFR, SER and slow scan functions Graphical manipulation of full record data Time and magnitude zoom Overlay multiple records Controlled editing, transmitting and archiving of configurable parameters Sequence components analysis Harmonic analysis Calculation of watts, vars, frequency, etc In this way, data from various parts of the power system can be automatically retrieved and made available for immediate display and analysis in a convenient manner. Profiles can also be used to retrieve power system monitoring data from multiple sites creating a single record containing system wide information, including phasors. Replay Plus is fully compatible with existing installed Hathaway DFRs (i.e. DFR 1200s and DFR IIs). Replay PlusDemonstration A demonstration copy of Replay Plus is available on 3.5 diskettes or on a CD-ROM. Contact Hathaway for details.

15 Wildflower Way Belfast BT12 6TA Northern Ireland Telephone: +44 1232 225200 Fax: +44 1232 225225 Internet: www.hathaway-systems.com 8228 Park Meadows Drive Littleton Colorado 80124 USA Telephone: +1 303 799 8200 Fax: +1 303 799 8880 Internet: www.hathawaycorp.com Replay Plus and Profiles are trademarks of Hathaway. All other trademarks and registered trademarks are properties of their respective companies and are hereby acknowledged.