99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING
100 air cooled liquid chiller and free cooling chillers VERSIONS : (R134a) Cooling capacity 178,0 1209,5 Liquid chiller equipped with screw compressors and axial fans. glider Y GENERL FETURES CL (R134a) Cooling capacity 326,0 1328,0 Liquid chiller with -Class Energy Efficiency equipped with screw compressors and axial fans. The units are a complete range including liquid chillers and free-cooling chillers, with high energy efficiency and reduced operating costs, granting an efficacious answer to the today s needs of comfort and Hi-Tech air conditioning as well as in the industrial process cooling. Developed with the most advanced 3D-CD software, chillers are available in two brand new cabinet types (for a more rational internal layout), an extremely innovative condenser fan section and the state of the art of electrical, electronics and refrigerating components. FREE (R134a) Cooling capacity 198,0 1106,0 Free Cooling capacity 279,0 1093,0 Liquid chiller equipped with screw compressors, axial fans and free cooling system. R134a CLSS SHELL C E C FREE COOLING CL CL FREE Cooling Screw type compressor R134a refrigerant charge class energy efficiency Shall and tube type evaporator xial fan with C motor xial with brushless type EC motor Free-Cooling system Outdoor installation gli
air cooled liquid chillers and free cooling chillers 101 MIN COMPONENTS Housing in epoxy painted galvanized steel profiles. Screw compressors xial fans with stepless speed control Shell and tube evaporator with one refrigerant circuit for each compressor Electronic expansion valve Free cooling system ( FREE) Pump-Down stop system MP.COM microprocessor control Electrical box in separate compartment -CLSS CL chillers stand out for the high efficiency of the whole series with EER values always superior to 3,1 -Class energy ratio, in agreement with EECCC (Energy Efficiency and Certification of Central ir Conditioning). Main switch with door lock safety glider f MIN OPTIONL CCESSORIES Pumping group Water tank Partial or total heat reclaim Glycol-Free system ( FREE) LNO kit for noise reduction ELN kit for extreme noise reduction Brine and Brine B kit for glycol solution production with temperatures down to -12 C. Serial port FREE COOLING The FREE series is a type of liquid chillers equipped with a built-in additional coil making Free Cooling using the outdoor air as cooling media. The free-cooling system installed on these chillers has been designed and applied by RC GROUP for the first time in the early 70 s and the today s series is the result of this experience. These chillers allow to achieve remarkable energy savings when installed in cold and temperate climate zones. der glider n
102 air cooled liquid chiller and free cooling chillers TECHNICL DT ND NOMINL PERFORMNCES 180 210 260 310 340 390 420 480 530 V2 N8 V2 N9 V2 N9 V2 Y2 V2 Y3 V2 Y3 V2 Y3 V2 Y3 V2 Y3 178,0 212,0 254,0 303,0 330,0 392,0 416,0 476,0 522,0 62,24 73,61 87,29 102,37 113,40 132,43 141,50 162,46 177,55 2230 2450 2480 3062 4263 4263 4263 4263 4263 71,9 74,0 74,5 77,0 76,6 78,7 78,7 78,8 78,8 610 (*) 680 (*) 720 (*) 780 (*) 870 (*) 990 (*) 1130 (*) 1210 (*) V2 Y4 V2 Y4 V2 Y5 V2 Y5 V2 Y5 V2 F14 V2 F16 V2 F20 609,6 676,6 714,0 784,9 874,4 987,7 1129,9 1209,5 194,02 214,81 226,30 251,30 278,56 312,17 357,40 387,14 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 5007 5433 5843 6359 6524 10313 11847 12820 80,8 80,8 81,7 81,5 81,5 80,5 80,9 81,0 (1) Referred to chilled water temperature 12/7 C and air to the condenser at 35 C (2) Sound pressure 1m far in free field conditions according to ISO3744 norms (*) s so marked are not EUROVENT certified POWER SUPPLY: 400/3/50 CL Class energy efficiency Energy Class More efficient + B C D E F G Less efficient 330 370 400 430 510 540 V2 Y3 V2 Y4 V2 Y4 V2 Y4 V2 Y4 V2 Y4 326,0 368,0 395,0 424,0 509,0 540,0 102,84 116,83 129,09 140,86 161,08 170,89 2 2 2 2 2 2 2 2 2 2 2 2 4166 4469 4636 4484 4803 4937 76,5 76,9 78,9 78,9 79,0 79,0 620 (*) 690 (*) 760 (*) 820 (*) 890 (*) 960 (*) 1010 (*) 1170 (*) 1330 (*) V2 Y5 V2 Y5 V2 F12 V2 F14 V2 F14 V2 F16 V3 F16 V2 F20 V2 F20 619,8 692,3 801,5 822,5 886,3 957,4 1020,6 1170,7 1328,0 182,77 204,29 202,79 239,62 259,12 280,78 300,13 340,55 390,65 5343 5638 8069 8913 9013 10807 11327 12980 13300 80,9 80,9 80,5 80,4 80,5 80,5 80,5 81,0 81,0 (1) Referred to chilled water temperature 12/7 C and air to the condenser at 35 C (2) Sound pressure 1m far in free field conditions according to ISO3744 norms (*) s so marked are not EUROVENT certified POWER SUPPLY: 400/3/50
air cooled liquid chillers and free cooling chillers 103 TECHNICL DT ND NOMINL PERFORMNCES FREE Free Cooling capacity (2) Sound pressure (3) 200 (*) 220 (*) 250 (*) 270 (*) 310 (*) 350 (*) 410 (*) 420 (*) 450 (*) 510 (*) 560 (*) 190 (*) 230 (*) V1 Y2 V1 Y2 V1 Y2 V1 Y2 V1 Y2 V1 Y3 V1 Y3 V1 Y4 V1 Y4 V1 Y4 V1 Y5 V2 Y2 V2 Y2 198 209 242 270 307 359 408 425 453 511 565 189 222 279 258 305 316 321 376 403 466 489 482 605 244 284 67,36 72,66 81,36 91,46 103,66 121,08 137,08 143,60 153,60 171,60 191,12 64,30 74,70 2 2 2 2 2 2 2 2 2915 3000 3176 3195 3419 4316 4260 5312 5472 5872 6382 3161 3314 70,2 70,2 70,2 70,2 70,2 73,2 73,2 74,9 74,9 74,9 77,4 71,2 71,2 Free Cooling capacity (2) Sound pressure (3) 260 (*) 320 (*) 360 (*) 430 (*) 540 (*) 630 (*) 700 (*) 740 (*) 830 (*) 860 (*) 930 (*) 1000 (*) 1110 (*) V2 Y3 V2 Y4 V2 Y4 V2 Y5 V2 Y5 V2 Y5 V2 Y5 V2 F12 V2 F16 V2 F16 V2 F16 V2 F20 V2 F20 271 312 354 405 532 628 698 733 823 851 925 990 1106 309 391 409 402 515 595 630 636 967 850 986 1220 1093 90,80 109,00 120,00 142,60 174,60 208,60 227,60 246,60 275,80 285,80 307,80 335,00 372,00 2 2 2 2 2 2 2 2 3799 5487 5633 6203 6497 7001 7038 9042 13506 13601 13725 15230 15789 74,2 76,9 78,9 79,4 79,4 79,4 79,4 80,5 80,5 80,5 80,5 81,0 81,0 (1) Referred to chilled water temperature 12/7 C / 20% glycol and air to the condenser at 35 C (2) Referred to water inlet temperature at 15 C / 20% glycol and outdoor temperature at 3 C (3) Sound pressure 1m far in free field conditions according to ISO3744 norms (*) s so marked are not EUROVENT certified POWER SUPPLY: 400/3/50
104 air cooled liquid chiller and free cooling chillers dimensions (mm) N V2 N8 4.400 1.800 1.990 c V2 N9 5.400 1.800 1.990 b a Y V2 Y2 3.756 2.310 2.490 V2 Y3 4.906 2.310 2.490 V2 Y4 6.056 2.310 2.490 V2 Y5 7.206 2.310 2.490 FREE Y c V1 Y2 / V2 Y2 4.033 2.310 2.540 V1 Y3 / V2 Y3 5.184 2.310 2.540 V1 Y4 / V2 Y4 6.335 2.310 2.605 V1 Y5 / V2 Y5 7.484 2.310 2.605 a b F V2 F12 7.855 2.320 2.560 V2 F14 8.925 2.320 2.560 V2 F16 10.299 2.320 2.560 V2 F20 12.439 2.320 2.560 c FREE F V2 F12 7.957 2.320 2.560 V2 F16 10.401 2.320 2.560 V2 F20 12.541 2.320 2.560 a b