SWE Series: 16 and 2 A Switches Increased Safety 16 A Version - Type 1 16 A Version - Type 2 2 A Version Compliance Data: ATEX - IEC: Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T6 Ex td A21 T8 C IP66 - IK9 or IK1 Electrical Data: Voltage Up to 69 V Amperage Up to 2 A Operating Temperature: 16 A 2 A -2 C to +4 C -2 C to +4 C 35
SWE Series: 16 and 2 A Switches Increased Safety ATEX / IEC IP66 - IK9 or IK1 Applications: Designed to prevent operation in explosive atmospheres during connect and disconnect operation of lighting and light power loads. For use in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation in chemical and petrochemical plants, refineries and other process industries. Features: 16 Amp version: Two bottom M2 clearance holes. Switch mechanism fixed at the bottom of the box. Termination: Type 1: 2.5 mm 2 Type 2: 2.5 mm 2 flexible/4 mm 2 solid Internal earth: 2 x 2.5 mm 2 terminals 1 x white self-adhesive laminated plastic label with black lettering (58 x 18 mm) 2 Amp version: Two M2 threaded entries on the bottom of the box. Switch mechanism fixed on the bottom of the box. Padlockable handle in position using maximum 4 padlocks (maximum handle dia. 8 mm and minimum 15 mm length). Termination: 2.5 mm 2 flexible / 4 mm 2 solid Internal earth: 2 x 4 mm 2 terminals 1 x yellow self-adhesive laminated plastic label with black lettering (65 x 18 mm) Standard Material of Fixtures: 16 Amp version: Polyamide box. A2 stainless steel coarse pitch screws (1 and a half turn). Polyamide cable glands. Nickel plated brass locknuts. 2 Amp version: Polyester box A2 stainless steel captive screws. Polyamide cable glands. Catalog Number Logic: SWE XX XXXX X X Series: SWE = SWE Series Zone 1, 2 21, 22 ATEX / IEC Certified Amperage: 16 = 16 A 2 = 2 A Switch Type: S = Switch C = Changeover- Switch Wiring Diagram No. X X XX Number of Poles: 1 = 1-Pole 2 = 2-Pole 3 = 3-Pole 4 = 4-Pole Ordering Information: 16 A Switch - Type 1 Padlockable handle. Two M2 polyamide cable glands (cable dia. 6.5 to 14.5 mm) on the bottom. Contact Configuration: 1 2 Type Diagram No. Type (kg) (dm 3 ) Number Number Changeover switch C11 1.53 2. SWE16C11AG 98614 2-pole S21 1.53 2. SWE16S21AG 9868 16 A Twist Button - Type 2 Non-padlockable handle. Two M2 clearance holes on the bottom. Type Diagram No. Type (kg) (dm 3 ) Number Number Changeover switch C1 2.5 2. SWE16C1A 98631 2-pole S2 2.5 2. SWE16S2A 98632 2 A Switch Padlockable handle. Two M2 polyamide cable glands (cable dia. 6.5 to 14.5 mm) on the bottom. Changeover switch C1 1. 2. SWE2C1AG 9625 2-pole S22 1. 2. SWE2S22AG 96251 3-pole S31 1. 2. SWE2S31AG 9626 4-pole S41 1. 2. SWE2S41AG 96261 Cable Entry: A = 2 x M2 Options: G = With Polyamide Cable Gland P = With Brass Earth Continuity Plate Switching Arrangement: 16 A Switch C11 Positions 11-12 23-24 X 1 X 16 A Twist Button C1 Positions 1-2 3-4 X 1 X 2 A Switch C1 Positions 1-2 3-4 X 1 X S31 Positions 1-2 3-4 5-6 1 X X X S41 Positions 1-2 3-4 5-6 7-8 1 X X X X S21 Positions 13-14 23-24 1 X X S2 Positions 3-4 3-4 1 X X S22 Positions 1-2 3-4 1 X X X Closed contact 351
SWE Series: 16 and 2 A Switches Increased Safety ATEX / IEC IP66 - IK9 or IK1 Technical Data: Main 16 Amps Type 1 16 Amps Type 2 2 Amps Rated Insulation Voltage 75 V 5 V 5 V Rated Operating Voltage 69 Vac 1 / 11 V DC 1 5 V 5 V Rated Operating Current 16 A 16 A 2 A Switching capacity: AC 1 16 A 69 V 16 A 5 V AC 12 16 A 4 V AC 14 1 A 4 V AC 15 16 A 415 V 6 A 5 V AC 21 16A 5V AC 23 16A 4V AC 3 8 A 5 V AC 3 4 A 69 V DC 1 1 A 24 V DC 1 6 A 6 V DC 1 6 A 11 V (*) DC 13 1 A 11 V DC 13 2 A 24 V Termination (flexible/solid) 2.5 mm 2 / 4 mm 2 2.5 mm 2 2.5 mm 2 / 4 mm 2 (*) 2 contacts connected in series Compliances: Hazardous Area Gas Dust Certified Type PCe Zones 1 2 21 22 Conforming to ATEX 94/9/CE CE 81 II 2 G CE 81 II2 D Symbol of Protection ATEX Symbol of Protection IEC Ex de IIC Ex td A21 T Rating T6 Surface Temperature T8 C Ambient Temperature -2 C to +4 C CE Declaration of Conformity 5221 ATEX Certificate LCIE ATEX 6472 IEC Certificate LCIE Ex.17 Other Certifications GOST Index of Protection (solid and liquid) IP66 Impact Resistance (shock) IK1 (Polyester) / IK9 (Polyamide) Dimensions (mm): 16 A Version 8 9 55 14 2 A Version Standards: Ex standards EN / IEC 679-; 679-1; 679-7; 61241-; 61241-1 Product standards EN / IEC 6947-1; 6947-3; 6947-5 EMC standards EN / IEC 5515; 61547 Other standards EN / IEC 6529 (IP); 62262 (IK) 352
SWE Series: 4, 63 and 16 A Switches Increased Safety 4 A / 63 A Version Compliance Data: ATEX - IEC: 16 A Version Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T5 or T4 Ex td A21 T95 C or T13 C IP66 - IK1 Electrical Data: Voltage Up to 69 V Amperage Up to 16 A Operating Temperature: 4 A and 63 A 16 A -2 C to +55 C -3 C to +55 C 353
SWE Series: 4, 63 and 16 A Switches Increased Safety ATEX / IECEx IP66 - IK1 Applications: Designed to prevent operation in explosive atmospheres during connect and disconnect operation of power loads. For use in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation in chemical and petrochemical plants, refineries and other process industries. Features: 63 Amp version: Padlockable handle in position O using max. 4 padlocks (max. handle dia. 8 mm and min. 15 mm length). 3 or 4-pole switch mechanism with one NO early break auxiliary contact. Main contact termination: 35 mm 2 Auxiliary contact termination: 2.5 mm 2 Cable entries: 1 x M32 clearance on top 1 x M32 and 1 x M2 clearance on bottom 2 x M32 polyamide cable glands (cable 1 to 25 mm) 1 x M2 blanking plug Yellow laminated plastic label with black lettering (65 x 18 mm) 16 Amp version: Hinged door. Closed with plastic double bar locks (key supplied). Supplied with 4 fixing lugs. Padlockable handle in position O. 3 or 4-pole switch mechanism with one NO early break auxiliary contact. Main contact termination: 12 mm 2 Auxiliary contact termination: 2.5 mm 2 Cable entries: 1 x M63 clearance on top 1 x M63 and 1 x M25 clearance on bottom 2 x M63 polyamide cable glands (cable 36 to 44 mm) 1 x M25 blanking plug Standard Materials: Polyester (GRP) box. 316L stainless steel box. A2 stainless steel captive screws. Polyamide cable glands and blanking plugs. Nickel plated brass locknut. Catalog Number Logic: SWE XX XXXX X X Series: SWE = SWE Series Zone 1, 2 21, 22 ATEX / IEC Certified Amperage: 4 = 4A 63 = 63 A 16 = 16 A Ordering Information: Switch Type: S = Switch C = Changer or Selector Switch Wiring Diagram No. X X XX Number of Poles: 3 = 3-pole 4 = 4-pole Contact Configuration: 1 2 Polyester Box: 63 A Switch 2 x M32 + 1 x M2 3-pole switch S32 8 14.5 SWE63S32EG 96269 4 Pole Switch S42 8 14.5 SWE63S42EG 9627 16 A Switch 2 x M63 + 1 x M25 3-pole switch S32 16 75 SWE16S32JG 96271 4 Pole Switch S42 16 75 SWE16S42JG 96272 Stainless Steel Box: 16 A Switch 2 x M63 + 1 x M25 4-pole switch S42 25 75 SWE16S42JS Options: G = With Cable Gland and Blanking Plug P = With Brass Earth Continuity Plate S = Stainless Steel Box Cable Entry: A = 2 x M2 B = 3 x M2 C = 2 x M25 D = 2 x M25 + 1 x M2 E = 2 x M32 + 1 x M2 Switching Arrangements: F = 2 x M4 + 1 x M2 G = 2 x M5 + 1 x M2 H = 2 x M63 + 1 x M2 J = 2 x M63 + 1 x M25 S32 Positions Aux 1 2 3 1 X X X X S42 Positions Aux 1 2 3 4 1 X X X X X 354
SWE Series: 4, 63 and 16 A Switches Increased Safety ATEX / IECEx IP66 - IK1 Technical Data: Main 63 Amps 16 Amps Rated Insulation Voltage 69 Vac 69 Vac Rated Operating Voltage 69 Vac 69 Vac Rated Operating Current 63 A 16 A Rated Surge Voltage 6 KV 8 KV Switching Capacity AC 21 A / AC 22 A 63 A 23 V to 69 V 16 A 4 V to 69 V AC 23 A 15 kw 23 V 22 kw 4 V 8 kw 4 V 3 kw 5 V 11 kw 5 V 55 kw 69 V 18.5 kw 69 V 11 kw 23 V AC 3 18.5 kw 4 V 9 kw 4 V 22 kw 5 V 7 kw 5 V 15 KW 69 V DC 21 16 A 22 V (*) 16 A 44 V (*) DC 22 16 A 22 V (*) DC 23 Auxiliary Rated Insulation Voltage 4 V 23 V Rated Operating Voltage 4 V 23 V Rated Operating Current 1 A 1 A Switching Capacity: (*) 2 contacts connected in series per pole 1 A 44 V (*) 16 A 22 V (*) 63 A 44 V (*) AC 15 6 A 23 V 4 A 4 V 6 A 23 V Others Termination (flexible/solid) 35 mm 2 12 mm 2 Compliances: Hazardous Area Gas Dust Certified Type CAe (Polyester box) Zones 1 2 21 22 Conforming to ATEX 94/9/CE CE 81 II 2 G CE 81 II2 D Symbol of Protection ATEX Symbol of Protection IEC Ex de IIC Ex td A21 T Rating T5 at +4 C T4 at +55 C Surface Temperature T95 C at +4 C T13 C at +55 C Ambient Temperature -3 C to +55 C, -2ºC to +55ºC (4 A & 63 A) CE Declaration of Conformity 5235 ATEX Certificate LCIE 2 ATEX 6248X IECEx Certificate LCI 4.16X Other Certifications GOST Index of Protection (solid and liquid) IP66 Impact Resistance (shock) IK1 Hazardous Area Gas Dust Certified Type JBe (Stainless steel box) Zones 1 2 21 22 Conforming to ATEX 94/9/CE CE 81 II 2 G CE 81 II2 D Symbol of Protection ATEX Symbol of Protection IEC Ex de IIC Ex td A21 T Rating T5 at +4 C T4 at +55 C Surface Temperature T95 C at +4 C T13 C at +55 C Ambient Temperature -3 C to +55 C CE Declaration of Conformity 5232 ATEX Certificate LCIE 2 ATEX 6118X IECEx Certificate LCIE Ex 2.1X Other Certifications GOST Index of Protection (solid and liquid) IP66 Impact Resistance (shock) IK1 Standards: Ex standards EN / IEC 679-; 679-1; 679-7; 61241-; 61241-1 Product standards EN / IEC 6947-1; 6947-3 EMC standards EN / IEC 5515; 61547 Other standards EN / IEC 6529 (IP); 62262 (IK) 355
SWE Series: 4, 63 and 16 A Switches Increased Safety ATEX / IECEx IP66 - IK1 Dimensions (mm): 4 A / 63 A Polyester Version 16 A Polyester Version 16 A Stainless Steel Version.. 356