User Guide Storage Tower V (ST55HPMXU)

Similar documents
User Guide Storage Tower IX (ST95HPMXA)

User Guide RAID Tower IV (RTIV535HEU3)

User Guide RAID Rack (RR2035ASDES)

T E C H N O L O G I E S. User Guide. RAID Tower IX.

User Guide 5-Port HPM-XU (AD5HPMREU)

User Guide RAID Rack (RR2035ASDML)

RAID Tower XIII (RT134SDEU3)

User Guide External Port Multiplier Ultra (AD5EHPMEU3)

User Guide 1U RAID Rack with esata /U3 /FW800 (R1ESU3F)

RAID Rack (RR2035RPHMS)

Addonics TECHNOLOGIES

User Guide Diamond Drive Cartridge System DDCSSAS / DDCSIS DDCSSAU / DDCSIU

T E C H N O L O G I E S. User Guide. 1:9 HS HDD Duplicator Pro (HD9SITDRHS)

PCIE SATA II PATA RAID CARD

Diamond Cipher Drive Cartridge System (DCDC256S-C, DCDC256U-C)

SERVER RSV-S4 USER Manual

T E C H N O L O G I E S. User Guide. 1:4 Blu-Ray & 1:11 DVD DigiCopier (DGBR4DR11)

Example of back panels with different interface connection

Addonics T E C H N O L O G I E S. Storage Tower Overview. Storage Tower

User Guide Diamond Cipher AES 256-Bit ExDrive (DCED256ES / DCED256EU)

Addonics T E C H N O L O G I E S. Portable Dual Drive RAID Enclosure. Model: AE25RDESU. Enclosure Overview. RAID Setting button

T E C H N O L O G I E S. User Guide. 1:1 Duplicator (HDUSAS)

Addonics T E C H N O L O G I E S. Jupiter Mobile Rack AJMRI, AJMRSA. User s Guide Version 1.0

User Guide 1:11 HDD Duplicator NB (HDUS11NB)

T E C H N O L O G I E S. User Guide. 1:7 Blu-Ray / DVD Duplicator (DDU7SAS)

Model: DS-2250J. Venus T5 mini 2.5 SATA RAID. User Manual.

VP101-BT Installation Guide

RAIDECKER BT-3058 User Manual

T E C H N O L O G I E S. User Guide. 1:5 Duplicator (HDU5SAS)

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, v1.2

RAIDTech USER S MANUAL. Revised October 3, Features

After completing this chapter, you will meet these objectives:

PCIe SATA II Channel RAID Card. User Manual

1:5 Combo msata HDD Duplicator (MSHDUS5HS)

HP ProLiant MicroServer

T E C H N O L O G I E S. User Guide. 1:5 HDD/SSD Duplicator Deluxe C (HD5SNDXHS, HDUS5SNDX)

Computer Assembly Step by Step DRAFT

IT Essentials (ITE v5.0 & v5.02) Chapter 3 Exam Answers 100% 2016

RAID Card with HyperDuo

TOWERSTOR TS25CT. QUICK INSTALLATION GUIDE v1.0

8/16/32-Ch Network Video Recorder NVR Series

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

CONTENTS. 1. Motherboard installation Install 5¼ and 3½ drives Install PCI components Case fan setup...5

CONTENT. Overview 1 LED indication. RAID Mode Selection 3. Quick Installation Guide 4. About RAID RAID function. System Requirements

Quick Installation Guide DS-4200-RM Pro Series

T E C H N O L O G I E S. User Guide (HDUS4SNDXHS-A)

RocketRAID esata For Mac HighPoint Technologies, Inc.

Highly Reliable Systems

T E C H N O L O G I E S ENT ESC. User Guide. 1:4 CF or CFAST Duplicator PRO (CFASTD4-2S / CFD4-2S)

A12S2-PS. Quick Start Guide. August, 2012 V.1.4

ivdr Storage Towers and Racks

Installation Instructions

CPU fan has a power connector which needs to be connected to CPU fan power socket on your motherboard as shown on the image above.

Taurus - USB. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English)

T E C H N O L O G I E S. User Guide. 1:1 HDD Duplicator PRO (HDUSI325)

SATA DVD/CD Duplicator Controller User s Manual

PCIe SATA 6G + PATA Card

PCIe SATA 6G + PATA RAID Card

DS-101g+ Disk Station Quick Installation Guide

Low Cost Mac Pro SATA Host Adapter Review: Addonics PCI Express Two Port SATA Host Adapter for Mac Pro (ADSA3GPX1-2EM) By Arthur Whalem

USB to RS-422/485 Serial Adapter

Storage Tower XIII INTRODUCTION. Addonics Technologies Inc Junction Avenue, San Jose, CA Phone: Fax:

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

User s Manual. Home CR-H408 4-Bay Portable RAID Tower EXTERNAL 4 BAY SATA RAID USB3.0 & esata ENCLOSURE

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

PCI EXPRESS CARD SATA

User s Manual. Home CR-H458 4-Bay Portable RAID Tower EXTERNAL 4 BAY SATA RAID USB3.0 & esata ENCLOSURE

742S 742i SC742 CHASSIS USER'S GUIDE

T E C H N O L O G I E S ENT ESC. User Guide. 1:5 HDD Duplicator Deluxe (HDUS5325DX)

Mini-EPICa USB 3.0-to-SATA II RAID SUBSYSTEM

Atlas Quiet Mini Server Case. User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario

SATA 150 Controller PCI Card user

NVIDIA / JMicron RAID Installation Guide

Install New External Hard Drive Windows 7 Sata

Server Systems and Motherboards

Skullcandy Air Raid USB Board Replacement

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

USB-C to esata Cable - For External Storage Devices - USB 3.0 (5Gbps) - 3 ft. (1 m)

1 Introduction. Package Contents. Product Features

Installation Guide AHA -1530P/1532P. Plug and Play AT-to-SCSI Host Adapter with SCSISelect Utility

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 6 Supporting Hard Drives

DP SATA 6Gb/s PCIe i/e Quick Installation Guide

3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Addonics. 4X SATA Multilane PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-ML) User s Guide Revision 1.1 T E C H N O L O G I E S

LabSim Mapping Matrix

Since August 2005 the DELL Optiplex GX-280 is end of live. So we replace this machine with a new model of DELL Optiplex-PC s, it s the GX 520.

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

Chapter 3: Computer Assembly

Section 5 MUST BE COMPLETED BY: 12/5

1. Support for AMD AM3+ processor 2. Support for AMD AM3 Phenom II processor / AMD Athlon II processor

Blu-ray/DVD/CD Duplicator Control Manual. User s Manual

This is a learning module for a specific Learning Outcome as stipulated in the HSP that is :

INFORMATION AND COMMUNICATION TECHNOLOGY

Taurus Mini Super-S LCM

Addonics. Combo RAID System. Users Guide Revision 1.0

2 To display the Administration Home page, click the Administration link. (You may need to provide the Administrator password.)

USB 3.1 Type-C Gen 2 Dual-Bay External M.2 NGFF SATA Enclosure Model

GOLD SERIES DVD/CD Duplicator Manual

Transcription:

T E C H N O L O G I E S User Guide Storage Tower V (STHPMXU) v8.. Technical Support If you need any assistance to get your unit functioning properly, please have your product information ready and contact Addonics Technical Support at: Hours: 8:0 am - 6:00 pm PST Phone: 08--6 Email: http:///support/query/

Screws Removing Cover of Storage Tower V Loosen the screws at the back of the tower using a Philips screwdriver by turning counter-clockwise. Separate the metal casing of the tower from the housing by lifting up the casing. Installing drives into the Storage Tower Step Screw the hard drives into the optional mounting brackets or slide in. devices into the tower. Other types of enclosures like the SA disk array can also be mounted. Mounting one SA disk array and another one SA disk array allows you to mount a maximum of 8 SATA drives. Step Using. SATA Hard Disk Drives Connect the internal SATA data cable to the data port of the hard drive then connect the -pin SATA power connector to the power port on the hard drive. Hard Disk Step Secure the hard disk by using screws provided. Repeat the above procedure for additional hard drives. Technical Support (M-F 8:0am - 6:00pm PST) Phone: 08--6 Email: /support/query/

SATA Port Drive activity LED Jumper Block (J) SATA Port Error LED Jumper Block (J) SATA Port Floppy Power Connector SATA Port 0 SATA Port esata Host Port (Port ) Dip Switch RAID Setting Button Dip Switch Settings Raid Mode Individual Drive (Factory Default) 0 and 0 Clone Large Enable ERR Buzzer Function AutoRebuilding to Spare Drive Technical Support (M-F 8:0am - 6:00pm PST) Port Multiplier Mode Phone: 08--6 Email: /support/query/

Default factory DIP Switch setting: SW RAID Setting DIP Switch BZS Error buzzer function EZ Automatic rebuilding to spare drive (one of the drives on the raid is set as a spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically act as a drive replacement and rebuilding will automatically start. M RAID mode M RAID mode M0 RAID mode 0 SW BZS EZ M M M0... Error buzzer function is ENABLED (BZS) when dip switch is in position Auto-rebuilding to spare drive is DISABLED (EZ) Individual drive mode is ENABLED (M0~M) Note: When the default factory RAID setting is used, independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Image Sil, Sil chip set or controllers that are Port Multiplier (PM) compatible. Simultaneous DVD writing was tested using the Nero Burning Rom. LED Pin Header J J P P P P P0 P P P P P P0 P Error LED Activity LED J Drive Activity LED P Activity LED for esata host port lights up when it is connected to a SATA controller card. P0, P, P, P & P - Activity LEDs for port 0,,,, & light up when a drive is connected and blinks when there s drive activity. J Error LED P error LED for esata host port P0, P, P, P & P - error LED for port 0,,,, & Technical Support (M-F 8:0am - 6:00pm PST) Phone: 08--6 Email: /support/query/

Setting or Modifying the RAID Mode Using the JMicron HW RAID Manager Utility Program:. For Windows users, install the JMicron HW RAID Manager located on the SATA Controller CD. In the CD, go to Configuration Utilities > JMB9. This manager can be use to create and monitor the status of the RAID volume. It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager.. Modify the RAID mode on the -port HPM-XU using DIP switch Recommended to be used on operating system without JMicron HW RAID Manager support like Linux, Mac & Solaris. Windows users can also use the procedure below. Note: Steps A to D need to be performed each time the raid mode is modified. SW Set the DIP switch to factory default setting. a. BZS EZ M M M0 b. Press the RAID setting button with a ball point pen. c. While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the RAID setting button. Release it after at least seconds for hardware initialization. A single beep will be heard to indicate initialization is completed. The above steps act as a reset. d. Power off the system power. Technical Support (M-F 8:0am - 6:00pm PST) Phone: 08--6 Email: /support/query/

e. On the DIP switch, change (M0 to M) setting to the desired RAID mode using the diagram below. SW Clone Mode SW RAID 0 Mode All settings on the diagram shows Error buzzer function is ENABLED EZ function is DISABLED. SW SW Large Mode RAID & RAID 0 Mode BZS EZ M M M0 BZS EZ M M M0 SW BZS EZ M M M0 SW Individual Drives Mode RAID Mode BZS EZ M M M0 BZS EZ M M M0 BZS EZ M M M0 SW RAID Mode BZS EZ M M M0 Technical Support (M-F 8:0am - 6:00pm PST) Phone: 08--6 Email: /support/query/

RAID Setting Notes: RAID & RAID 0 Mode When drives are SW BZS EZ M M M0 connected to the HPM-XU, and DIP switch is set to this setting, the drives will be configured as a -drive RAID array. When drives are connected to the HPM-XU, the drives will be configured as a -drive RAID0 array. Clone Mode SW BZS EZ M M M0 Clone s action is similar to RAID. However, all of the hard drives will be mirrored. Clone mode is useful especially when users like to copy data from a source hard drive to the drives connected to the HPM-XU. f. Press the RAID setting button with a ball point pen. g. While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the RAID setting button. Release it after at least seconds for hardware initialization. A single beep will be heard to indicate initialization is completed. h. Verify if the RAID array is detected by the system. i. If the -port HPM-XU is connected to the motherboard onboard SATA, on the CMOS setup utility, the raid array will display as Addonics H/W RAID if setup as a RAID array. j. If the -port HPM-XU is connected to an esata host controller card, on the RAID BIOS, the raid array will display as Addonics H/W RAID0 if setup as a RAID0 array. k. If booted into Windows, in Disk Drives under Device Manager, the raid array will display as Addonics H/W LARGE if setup as a LARGE array. l. Once raid array is verified, you can set the buzzer either or. Technical Support (M-F 8:0am - 6:00pm PST) Phone: 08--6 Email: /support/query/

Notes on Spare Drives using the Easy RAID Setting (EZ) When EZ function is ENABLED, the auto-rebuilding to spare drive is automatic. The degraded RAID group will start rebuilding automatically by using the existing spare drive. * Spare drive can be either plugged before RAID building or a new drive can be plug as the spare drive when RAID rebuild is required. A. B. Which port acts as a spare drive? The last drive will automatically become the spare drive. For a -drive RAID with spare: Drives connected to SATA ports ~ belong to the active RAID array and drive connected to port is the spare. For a -drive RAID0 with spare: Drives connected to SATA ports ~ belong to the active RAID0 array and drive connected to port is the spare. For a -drive RAID with spare: Drives connected to SATA ports & belong to the active RAID array and drive connected to port is the spare. When will rebuild action start? When the raid fails and EZ is enabled, the HPM-XU will automatically rebuild the RAID group using the spare. When the raid fails and EZ is disabled, the HPM-XU will NOT rebuild the raid group unless you install a good drive to replace the failed drive. Connecting the Power Cable and Storage Tower to the Computer Back a. b. c. Connect the power cord provided from the wall outlet to the back of the tower. Make sure the power is off (power LED light should be off). Connect the esata or USB cable from the back of the tower to the matching port on the computer. Power Connecto r Power Switch Power on/off control a. b. c. A main power switch is located at the back of the tower. Turn the switch on. Another auxiliary switch is located on the front of the tower. Make sure the power is off on the auxiliary switch (power LED light should be off). Power on the tower. Technical Support (M-F 8:0am - 6:00pm PST) Bottom Front Power Switch HDD LEDs Phone: 08--6 Email: /support/query/

CTACT US Phone: Fax: Email: 08-7-880 08-7-888 http:///sales/query/