Release Notes P/N REV 04 March 28, 2013

Similar documents
EMC CEE. Using the Common Event Enabler on Windows Platforms. Version 8.2 P/N REV. 03

DefendX Software Mobility Proxy Service for EMC

DefendX Software Mobility Proxy Service for EMC

NTP Software QFS for EMC

DefendX Software Control-QFS for EMC Installation Guide

NTP Software VFM Proxy Service for EMC

NTP Software VFM Proxy Service for EMC

NTP Software Defendex (formerly known as NTP Software File Auditor) for EMC

DefendX Software Control-Audit for EMC Installation Guide

EMC VNXe Series. Configuring Hosts to Access NFS File Systems. Version 3.1 P/N REV. 03

Dell EMC Unity Family

Symantec Endpoint Protection Integration Component User's Guide. Version 7.0

FluidFS Antivirus Integration

Veritas Data Insight Software Compatibility List 6.1.1

Release Notes P/N REV A01 August 11, 2010

NTP Software QFS. Installation Requirements

Product Support Notice

Veritas Data Insight 6.1 Software Compatibility List 6.1

DefendX Software Control-Audit

NTP Software File Auditor

CTA and CTA/VE 10.0 SP3 Interoperability Matrix EMC Part Number = Rev.09

INTEROPERABILITY OF AVAMAR AND DISKXTENDER FOR WINDOWS

NETWRIX INACTIVE USER TRACKER

Patch Manager INSTALLATION GUIDE. Version Last Updated: September 25, 2017

Configuring Symantec. device

Using the Celerra server_archive Utility

CTA and CTA/VE 10.0 SP3.1 Interoperability Matrix EMC Part Number = Rev.10

Configuring Symantec Protection Engine for Network Attached Storage for Hitachi Unified and NAS Platforms

Antivirus Solution Guide for Clustered Data ONTAP: Sophos

Dell EMC Unity Family

McAfee Firewall Enterprise and 8.3.x

EMC Celerra NS20. EMC Solutions for Microsoft Exchange Reference Architecture

Securing VSPEX VMware View 5.1 End- User Computing Solutions with RSA

FILE SYSTEM AUDITING WITH EMC ISILON AND EMC COMMON EVENT ENABLER

DefendX Software QFS Installation Requirements

EMC Documentum xcelerated Composition Platform Developer Edition Installation Guide

Kaspersky Administration Kit 8.0 REFERENCE GUIDE

VERITAS StorageCentral 5.2

Symantec Enterprise Vault Technical Note

Dell EMC Unity Family

DefendX Software Control-QFS for Isilon Installation Guide

Scalability Guidelines

TECHNICAL NOTES. Technical Notes P/N REV 01

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

DefendX Software Control-Audit for Hitachi Installation Guide

NTP Software QFS for Isilon

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

Antivirus Solution Guide. NetApp Clustered Data ONTAP 8.2.1

IBM Proventia Management SiteProtector. Scalability Guidelines Version 2.0, Service Pack 7.0

Problem Resolution Roadmap for VNX with ESRS IP Client for VNX and Connect Home

Forcepoint Sidewinder

Altiris Symantec Endpoint Protection Integration Component 7.1 SP1 Release Notes

Configuring Symantec Protection Engine for Network Attached Storage. Dell FluidFS 5.0

EMC VSI for VMware vsphere AppSync Management

Symantec Antivirus Manual Removal Tool Corporate Edition 10.x

EMC Storage Monitoring and Reporting

IBM Proventia Management SiteProtector Installation Guide

NTP Software VFM. Installation Requirements

Release Notes P/N REV A10

Unicode and the Implications of Its Implementation

McAfee Firewall Enterprise

NTP Software File Reporter

BCPro Installation Instructions Code No. LIT Software Release 3.0 Issued September 2017

Antivirus Solution Guide for Clustered Data ONTAP: Kaspersky

EMC Solutions for Microsoft Exchange 2007 NS Series iscsi

Release Notes for Avaya Proactive Contact 5.0 Supervisor. Release Notes for Avaya Proactive Contact 5.0 Supervisor

NTP Software File Auditor for Hitachi

Connectware Manager Getting Started Guide

Securing Your Environment with Dell Client Manager and Symantec Endpoint Protection

McAfee VirusScan Enterprise for Storage 1.3.0

Guardian Software Update Delivery Service User Guide

Using Celerra FileMover

Online Documentation: To access the online documentation for this and other Novell products, and to get updates, see

Policy for Using Anti-virus Software on S8100 Media Servers, IP600 Communications Servers, & DEFNITY ONE Communications Systems

EMC SourceOne TM Offline Access USER GUIDE. Version 6.8 P/N A01. EMC Corporation Corporate Headquarters: Hopkinton, MA

Technical Notes. EMC NetWorker SharePoint BLOB Backup and Recovery by using NetWorker Module for Microsoft and Metalogix StoragePoint TECHNICAL NOTES

Tivoli Access Manager for Enterprise Single Sign-On

Video Surveillance EMC Storage with LENSEC Perspective VMS

Product Release Notes for Avaya Proactive Contact Supervisor

EMC Surveillance for Axon Commander

SIMATIC. Process Control System PCS 7 V7.0 SP1 Security Information Note: Setting up antivirus software. Preface. Using virus scanners 2

Configuring Symantec AntiVirus for BlueArc Storage System

Antivirus Solution Guide for Clustered Data ONTAP: Symantec

Remediation Testing Report

NETWRIX PASSWORD EXPIRATION NOTIFIER

Altiris Software Management Solution 7.1 from Symantec User Guide

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.

TECHNICAL NOTES. Technical Notes P/N REV 01

Installation Instructions

Upgrade to Webtrends Analytics 8.5: Best Practices

EMC VNX Series: Introduction to SMB 3.0 Support

Release Notes P/N REV A03 January 3, 2006

METADATA FRAMEWORK 6.3. Probe Configuration

EMC Celerra NS-120 System (Dual Blade) Installation Guide

Symantec ediscovery Platform

AMS Machinery Manager

Surveillance Dell EMC Isilon Storage with Video Management Systems

Getting Started Guide. This document provides step-by-step instructions for installing Max Secure Anti-Virus and its prerequisite software.

EMC VSPEX END-USER COMPUTING

Release Notes P/N REV A01 February 23, 2006

Transcription:

EMC VNX Event Enabler Version 5.1.0.0 Release Notes P/N 300-013-478 REV 04 March 28, 2013 This document provides information about the latest release of EMC VNX Event Enabler software and related documentation. Topics include: Revision history... 2 Product description... 2 New features and changes... 2 Environment and system requirements... 3 Fixed problems... 5 Known problems and limitations... 5 Problem prevention... 7 Technical notes... 8 Documentation... 11 Troubleshooting and getting help... 12 1

Revision history Revision history The following table presents the revision history of this document. Revision Date Description 04 March 28, 2013 Updated for release 5.1.0.0 03 December 19, 2012 Updated for release 5.0.8.2 02 July 16, 2012 Updated for release 5.0.6.2. Added fixed problem 495847. 01 July 16, 2012 Initial release Product description The EMC VNX Event Enabler (VEE) framework contains the following facilities and is used to provide a working environment for these facilities: VEE Common AntiVirus Agent (CAVA) provides an antivirus solution to clients using a VNX server. It uses an industry-standard CIFS protocol in a Microsoft Windows Server environment. CAVA uses third-party antivirus software to identify and eliminate known viruses before they infect files on the storage system. The Using VNX Event Enabler technical module contains information about using CAVA. VEE CEPA is a mechanism whereby applications can register to receive event notification and context from the VNX system. CEPA delivers to the consuming application event notification and associated context (file/directory metadata needed to make a business policy decision) in one message. The Using VNX Event Enabler technical module contains information about using CEPA. VCAPS is a mechanism for delivering asynchronous "post events" in batch mode. The delivery can be triggered based on a time period or a number of events. While the VEE framework includes CAVA, CEPA, and VCAPS, they can also run independently. New features and changes Version 5.1.0.0 VEE now supports two Microsoft antivirus products: 2

Environment and system requirements Forefront Endpoint Protection 2010 System Center 2012 Endpoint Protection CEPA API now supports xml/http or xml/https. Version 5.0.8.2 There are no new features in this release. Version 5.0.6.2 There are no new features in this release. Version 5.0.6.1 There are no new features in this release. Environment and system requirements For the latest system requirements, consult the website or documentation of the particular third-party AV engine manufacturer. The AV engine version may differ depending on the operating system. Table 1 lists the minimum system requirements recommended by EMC for each AV server. Table 1. Minimum requirements for AV servers Hardware A workstation with: Intel Pentium III 700 MHz (or faster) 512 MB RAM minimum 50 MB free disk space Software Windows Server or any Windows operating system compatible with the vendor s consumer application software. Network CAVA must be running on a machine that is part of a valid Windows environment. Note: Share-level authentication or stand-alone Windows servers are not supported when using CAVA. Storage No specific storage requirements. Table 2 describes the VNX for File software, hardware, network, and storage configurations. 3

Environment and system requirements Table 2. System requirements Software Microsoft Windows Server or any Windows operating system compatible with the vendor s consumer application software. Two kits are available: EMC_VEE_Pack_Win32_xxxx for installation on Windows 32-bit operating systems EMC_VEE_Pack_x64_xxxx for installation on Windows 64- bit operating systems where xxxx = software version number You cannot install both a 32-bit and a 64-bit version of the software on the same machine. Note: Running VEE in the Windows on Windows (WOW) environment on a 64-bit platform is not supported. Search the EMC E-Lab Interoperability Navigator for consumer applications supported when using VNX Event Enabler. Hardware A workstation with: 600-megahertz Pentium III-compatible or faster 512 megabytes of RAM 80 megabytes of free disk space Network The Windows network must contain a domain controller with Active Directory and DNS enabled. Data Movers on VNX must be configured with the CIFS protocol. You cannot use a Virtual Data Mover for the CIFS protocol. Configuring and Managing CIFS on VNX provides more information on configuring the CIFS protocol. Storage No specific storage requirements. Table 3 lists the minimum system requirements for the CAVA Calculator. Table 3. Minimum requirements for CAVA Calculator Software Microsoft Windows Server Microsoft.NET Framework 1.1 CAVA Tools Hardware No specific hardware requirements. Network No specific network requirements. Storage No specific storage requirements. 4

Fixed problems Fixed problems Severity Symptom Description Fix Summary Tracking Number 2 Some AV engines remediate infections outside the scope of their scans, which could cause a file to be released too soon from the DART AV scan queue. CAVA heartbeat now respond swith "remediationwindow" to prevent this issue. 544015 Known problems and limitations Microsoft antivirus agent support Forefront and System Center 2012 Endpoint Protection are supported only in environments where all Data Movers, CAVA machines, and Microsoft AV machines are in the same Active Directory Forest. Microsoft antivirus agents on a Data Mover If you use either Forefront or System Center 2012 Endpoint Protection on a Data Mover, the server_viruschk command lists the AV server generically as Microsoft AV. CAVA is for CIFS clients The CAVA feature of the VEE product is for CIFS clients only. If NFS or FTP protocols are used to modify files, the files will not be scanned for viruses. No UNIX antivirus application support is provided. CEPA support CEPA supports clients that run either the CIFS or NFS protocol only. If the FTP protocol is used to move or modify files, no events are processed or published for the files. File-Level Retention It is strongly recommended that the antivirus (AV) administrator updates the virus definition files on all resident AV engines in the CAVA pools, and periodically run a full file system scan of the file system to detect infected FLR files. The Using VNX Event Enabler technical module provides additional information about virus definition updates. 5

Known problems and limitations Microsoft Access Restricted Group GPO Using Microsoft SMB2 Do not scan Microsoft Access database files in real time. Files inside a database are not scanned. CAVA requires the antivirus domain account (AV user account) to be in the local administrators group of the VNX for File CIFS server. If the CIFS server has Restricted Group GPO enforced and the AV user account is removed from the local administrators group, after the next CAVA restart, the status will change from ONLINE to AV_NOT_FOUND. To ensure that the CAVA status remains ONLINE, you must either include the corresponding AV user account in the Restricted Group, or remove the Restricted Group. When using Microsoft SMB2 as the protocol between AV engines and the VNX for File, the Microsoft Redirector uses a local cache for directory metadata on the machine where the AV engine resides. By default, this cache is invalidated every 10 seconds. As a consequence, the updates that are made to the server share during this period might not be seen in the cache. When this occurs, the AV engines cannot scan the files requested by CAVA because the contents of the Redirector s cache and the actual directory structure on the server share do not match. The Data Mover s server_log contains the following SMB2 error message: file not found. Workaround To prevent this condition, disable the directory cache on the machines on which CAVA and AV engines are running by using the following procedure: 1. Open the Windows Registry Editor and navigate to HKLM\SystemCurrentControlSet\Services\LanmanWorkstation\P arameters. 2. Right-click Parameters and select New > DWORD Value. 3. For the new REG_DWORD entry, type a name of DirectoryCacheLifetime. 4. Set the value to 0 to disable DirectoryCacheLifetime. 5. Click OK. 6

Problem prevention 6. Restart the machine. Windows 64-bit operating systems 64-bit CAVA agent cannot work with 32-bit antivirus engines The 64-bit CAVA agent cannot work with a 32-bit antivirus (AV) engine. If you are using a 32-bit AV engine, you must use 32-bit CAVA. Similarly, if you are using a 64-bit AV engine, you must use the 64-bit CAVA. Loading a 32-bit driver on a 64-bit Windows operating system is disallowed by Windows. When using CAVA with a 32-bit driver-based AV engine, you must load the AV engine and CAVA/VEE on a 32-bit Windows OS. This does not apply to an API-based AV engine. A 32-bit API-based AV engine and 32-bit CAVA can be loaded on a 64- bit OS. At this time, the only API-based AV engine supported with CAVA is Symantec AV for NAS. MS-RPC In order to run VEE on Windows 64-bit operating systems, the VNX for File -to-cee communications must be over Microsoft RPC (MS-RPC). The version of VEE that runs on Windows 64-bit operating systems is supported with Celerra version 5.6.45 or later and VEE version 4.5.0.4 or later. Windows Server 2008 Problem prevention If you are using Windows Server 2008, you must manually compile the cava.mof file while using the EMC cavamon sizing tool. The EMC Customer Service center has reported a number of calls concerning the following issues. Take a moment to familiarize yourself with these potential issues. VNX Common AntiVirus Agent Number of CAVA engines It is possible to configure your EMC VNX installation with only one CAVA engine. However, this non high-availability configuration can make your installation susceptible to data unavailability in the event that the CAVA engine goes offline for any reason. The best method for 7

Technical notes preventing this type of outage is to increase the number of available CAVA engines. Additional information for configuring the Common AntiVirus Agent can be found in the Using VNX Event Enabler technical module. This document describes the parameter settings that specify shutdown actions to take when no servers are available. Performance If a large number of files need to be checked at the same time, the CAVA file checking process may be slow depending on the number of threads configured, the number of CAVA servers, and the speed of the CAVA servers. If the CAVA servers cannot process file checks quickly enough, then all antivirus (AV) threads become busy and the AV collector queue increases, indicating that file check requests are queuing up. Increasing the number of AV threads (10 by default) allows more files to be checked in parallel and may improve performance. However, the number of CAVA engines may need to be increased to satisfy a heavy load. Removing AV user from Data Mover password file Technical notes If you remove an AV user from the Data Mover password file, CAVA will not work. Depending on the setting you have on CIFS, you could either use up all of the CIFS threads because they are used for virus checking, or CAVA could shut down CIFS altogether. System Requirements for Windows 8 and Windows Server 2012 Windows 8 and Windows Server 2012 install and enable by default the.net Framework 4.5. However, the VEE Framework, cava.exe, is a.net Framework 3.5 service. You must enable.net Framework 3.5. The Microsoft website contains instructions on enabling the.net Framework 3.5 on Windows 8 and Windows 2012 at: http://msdn.microsoft.com/en-us/library/hh506443.aspx 8

Technical notes VNX for File virus checking solution Third-party antivirus engines Table 4 lists the requirements for using CAVA with third-party antivirus engines. Table 4. Virus checking solution requirements All Vendor VNX for File version AntiVirus version Computer Associates etrust r8.1 etrust r8 TrendMicro ServerProtect for EMC NAS 5.3.1 ServerProtect for EMC NAS 5.8 Sophos AntiVirus 3.x AntiVirus 5.x AntiVirus 6.x AntiVirus 7.x AntiVirus 9.x AntiVirus 10.x Kaspersky Kaspersky Anti-Virus for Windows Servers Enterprise Edition McAfee VirusScan 8.0i VirusScan 8.7i VirusScan 8.8i Patch 1 Microsoft System Center 2012 Endpoint Protection SP1 [Antimalware Client Version: 4.1.522.0] All currently-supported VNX for All currently-supported VNX for Common AntiVirus Agent (CAVA) 3.4.0 and later Common AntiVirus Agent (CAVA) 3.4.0 and later Common AntiVirus Agent (CAVA) 3.4.0 and later 5.6.46.4 and later 4.5.1 and later,2 Common AntiVirus Agent (CAVA) 3.4.0 and later 5.1.0.0 and later 9

Technical notes Forefront Endpoint Protection 2010 with hotfix KB2758685 [Antimalware Client Version: 4.1.522.0] Symantec Symantec Endpoint Protection 11.06 Symantec Endpoint Protection 12.1 Symantec Endpoint Protection v12.1 MU1 Symantec Endpoint Protection v12.1 MU2 Symantec Protection Engine 7.0 SAV for NAS 5.2.x SAV for NAS 4.3.x F-Secure F-Secure E-mail and Server Security 9.20 with F-Secure hotfix FSESS920-900 F-Secure Server Security 9.20 with F-Secure hotfix FSSS920-900 5.6.48.x and later 5.6.48.x and later 2 5.6.48.x and later 2 4.5.2.2 and later 5.0.8.2 and later 5.0.8.2 and later 5.0.8.2 and later Common AntiVirus Agent (CAVA) 3.6.2 and later 5.0.8.2 and later 5.0.8.2 and later Configuration guidelines 1 Currently supported NAS versions include the entire 5.6.x, 6.0.x, 7.0.x, and 7.1.x families. Refer to the EMC E-Lab TM Interoperability Navigator for the latest supported version information. 2 From the VNX Control Station, issue the command: server_param server_n f viruschk l. If the result has AvAgents viruschk Kaspersky:Symantec AV Kaspersky:Symantec AV:FSecure:Microsoft Antivirus, no action is required. If this is not the result, please add the following line to the /nas/server/server_(n-1)/param file: param viruschk AvAgents:Kaspersky:Symantec AV:FSecure:Microsoft Antivirus. Then, reboot the Data Mover. Table 5 lists the configuration guidelines for the CAVA. The values listed in this section represent the highest or lowest values tested by EMC. In some cases, actual capacities may exceed the capacities tested by EMC. 10

Documentation Table 5. Virus checking guidelines Guideline/specification Virus checker file pending Maximum tested value 90% of available VNODES in system Comment The percentage of total cached open files available in the system that can be pending on Virus Checking. An event is sent to the Control Station when the maximum is reached. To change the default value, modify param viruschk.vnodemax(default=2000) and/or param viruschk.vnodehwm(default=0x5a(90%). Parameter information can be found in the Parameters Guide for VNX for File. Documentation VNX for File version 7.1 Antivirus This section lists the VEE related user documentation for File Version 7.1. These documents can be downloaded from EMC Online Support at http://support.emc.com. Table 6 lists information for antivirus protection described in technical modules and online help. Table 6. Antivirus Part number Name Description Online help CAVA Calculator Describes using the CAVA Calculator sizing tool to estimate the number of CAVAs required to provide a user-defined level of performance in a CAVA pool, based upon user information. Online help Common AntiVirus Management Explains how to modify CAVA virus-checking configuration parameters on a Data Mover from a Microsoft Windows Server. 300-013-502 Using VNX Event Enabler Describes how to install and configure the VNX Event Enabler Framework software that provides a working environment for the CAVA and CEPA facilities. 11

Troubleshooting and getting help Part number Name Description 300-013-443 Getting Started with EMC VNX Event Enabler 300-013-803 VNX Event Enabler Publishing Agent API Guide Helps you to verify the product shipment and set up an EMC Support website account. Describes how to create a CEPA configuration file, issue CEPA commands using the CLI, and assign the EMC Event Notification Bypass privilege to suppress thirdparty application events. Troubleshooting and getting help Where to get help Product information Troubleshooting Technical support EMC support, product, and licensing information can be obtained as follows. For documentation, release notes, software updates, or for information about EMC products, licensing, and service, go to EMC Online Support (registration required) at: http://support.emc.com Go to EMC Online Support. After logging in, locate the appropriate Support by Product page. For technical support and service requests, go to EMC Customer Service on EMC Online Support. After logging in, locate the appropriate Support by Product page, and choose either Live Chat or Create a service request. To open a service request through EMC Online Support, you must have a valid support agreement. Contact your EMC Sales Representative for details about obtaining a valid support agreement or to answer any questions about your account. Note: Do not request a specific support representative unless one has been assigned to your particular system problem. 12

Troubleshooting and getting help Copyright 2013 EMC Corporation. All Rights Reserved. Published in the USA. Published March 2013 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries. All other trademarks used herein are the property of their respective owners. For the most up-to-date regulatory document for your product line, go to the technical documentation and advisories section on the EMC online support website. 13