Integrated Control Panels Utnytt dine digitale muligheter Basic Automation TIA Portal Siemens AG 2017 www.siemens.com/panelbuilding
Example of a network topology Actuators & Sensors in TIA Portal S7 1500 Field PG Touch panel PROFINET SIMOCODE AS-Interface ET 200SP Motor Starter Motor SIRIUS ACT PROFIBUS DP SCALANCE W788 IWLAN PB Link PN IO Soft Starter ET 200SP Motor Starter Soft Starter SIRIUS 3RA6 Compact Starter IO-Link Sensors Motors
SIRIUS ACT 3SU1 with Profinet & ET200SP Failsafe Motor Starter Page 3
SIRIUS ACT Convinces with its communication PROFINET, AS-I or IO-Link interfacing possible Fast and direct connection to the control system Integrated into the TIA Portal Reduce your wiring outlay through diverse communication solutions. SIRIUS ACT Performance in Action Page 4
SIRIUS ACT PROFINET Flexibility in all applications 1. PLC 2. Interface Module 3. Terminal Module 1. PLC 2. Failsafe Interface Module 3. Terminal Module Maximum expansion: Cable length between modules: Total cable length (IM TM): Power supply: System data 1 interface module + 20 terminal modules 1 meter 10 meters 24 V DC Page 5
SIRIUS ACT PROFINET The clever way to connect Engineering Operator control & monitoring Ethernet Controller PROFINET Yesterday Standard Panel HMI + SIRIUS ACT Significantly reduced wiring Easy connection to HMI via PROFINET Quick and easy installation Reduces fault probability Safety and standard technology through one cable SIRIUS ACT PROFINET Panel HMI + SIRIUS ACT Today SIRIUS ACT with PROFINET Added value through reduced wiring Seite 6
SIRIUS ACT PROFINET Fast and safe through PROFIsafe Engineering Operator control & monitoring Ethernet Controller PROFINET PROFINET / PROFIsafe SIRIUS ACT interface module EMERGENCY STOP does not need to be wired separately Safety and standard technology through one cable Reduced wiring SIRIUS ACT failsafe interface module Panel HMI + SIRIUS ACT Panel HMI + SIRIUS ACT SIRIUS ACT PROFINET Added value integrated safety technology Seite 7
SIRIUS ACT PROFINET Diagnostics options without controller Hardware diagnostics Features Customer benefits How are faults found? LED test: all LEDs light up for 2 sec. when the supply voltage is applied Diagnostics via status LEDs Fast fault detection on the device Function test possible without controller and without controller know-how With or without controller No fault Function tests can be performed without controller System configuration possible without subject-specific knowhow Device defective! Wiring error SIRIUS ACT device has been operated Seite 8
SIRIUS ACT PROFINET Sømløs integrasjon av sensor - IoT Integration into the TIA Portal + Integrated safety technology + Universal system for all SIRIUS ACT devices + Quick and easy installation + Reduced wiring + High flexibility based on additional interfaces (DI, DQ, AI) +
ET 200SP the only I/O system with integrated motor starters Introduction The motor starter module completes the ET 200SP I/O system Switching and protection device for three-phase induction motors, single-phase AC motors and three-phase asynchronous motors Integrated short-circuit and overload protection IMAGE Direct-on-line and reversing start function Diagnostics functions Energy management functions Fail Safe Motor Starter - SIL3/ PL e motor starter Page 10
Compact design with expansion options Design Motor starter module 3DI/LC module (optional) Motor terminals Infeed system connection Additional fan (optional) Infeed system forwarding BaseUnit Page 11
Wide system limits enable flexible configurations Design System limits Maximum structure up to 1 m wide, as in the ET 200SP system max. 30 starter Infeed bus can be loaded up to 32 A Power bus can be loaded for control voltage up to 7 A If the limit is reached, you can simply feed in a new. Page 12
Multifunctional rotary interlock with parking position Design Position 1: Operating position All electrical contacts are connected. The motor stater module is firmly anchored in the BaseUnit. Position 2: Assembly/disassembly position All electrical contacts are open. The motor starter module can be inserted in the BaseUnit or removed from it. Position 3: Parking position/off All electrical contacts are open. The motor starter module cannot be removed from the BaseUnit. The rotary interlock can be fixed in place with a padlock, thus ensuring the isolating function in accordance with IEC 60947-1. Page 13
BaseUnit explanation MS1: BU with infeed 24V and 400V MS2: BU with infeed 400 V (24 V bridged by previous BU) MS3: BU with infeed 24 V (400 V bridged by previous BU) MS4: BU without infeed (24 V and 400 V bridged by previous BU) MS5: BU with F-DI input and 400 V infeed MS6: BU with F-DI input (400 V bridged by previous BU) 24 V M 24 V M F-DI M F-DI M The fail-safe motor starter, can be used with ANY BU (MS1 MS6) up to SIL 3 Requirement: The 24 V supply is fed in via an F-DQ or F-PM-E module (also across BUs) Advantages when using BU30-MS5 and BU30-MS6 MS1 MS2 MS3 MS4 MS5 MS6 Page 14 Communication to the motor starter is retained in the event of a shutdown Fast restart after fail-safe shutdown
F-PME Group Shutdown with F-CPU, via F-PM-E 24 V of the motor starters is switched safely with the switch-off signal (backplane bus) of the F-PM-E During a safety shutdown, there is no corresponding diagnostics of the MS After the 24 V is switched on again, the MS first need to be restarted (longer switch-on duration that with MS5/MS6) 2-channel signal on ET 200SP F- PM-E Shutdown sequence MS 2 MS 4 1. Fail-safe PLC gives shutdown signal via PROFISAFE to the ET 200SP module F-PM- E. 2. F-PM-E switches off the 24 V to the safety starters internally and in a fail-safe manner. Page 17 3. The safety starters switch off the 400 V in a fail-safe manner.
Optional: Fail-safe shutdown without F-CPU Setup with standard CPU Realization of the safety functions with safety relay 24 V of the motor starters is switched safely with the safety relay Group assembly with MS1 + MS4 possible Diagnostics text: "24 V supply voltage missing" Individual shutdowns can be realized with 3SK2 2-channel signal on 3SK MS 1 F-DI M Note: M output on the BU of the ET 200SP motor starter must be on the same ground potential as the M output on 3SK Page 19
Use-Case MS is started by green illuminated push button (If MS is ready, green push button will be illuminated) MS is switched off by using of illuminated red push button TIA-Portal V14 Failsafe switch off by using of Emergency stop F-CPU Emergency stop is confirmed by using of blue push button (illumination will be switched off after using PB) F-PME is integrated by using of blue push button (illumination will be switched off after using PB) Confirmation request is shown by illuminated, blinking blue push button Page 20 E-Stop Reset ON OFF 3SU1 PN F F-MS