DVBS November 13, (12)

Similar documents
Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway

Luminato. Quick Start Manual. Teleste Corporation. Luminato First Time Installation. SW version 1.1.2

Cisco DCM Series D9901 Digital Content Manager MPEG Processor

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

CVH Slot Media Converter Chassis Quick Installation Guide

alliedtelesis.com/products

CHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP)

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER

Brochure. ION Multi-Service Integration Platform. Integrate. Optimize. Navigate. Transition Networks Brochure.

Dax Media Converter Chassis

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Industrial Switches Industrial Switches

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Product Overview. Switch Models CHAPTER

IS100 Silicom 100G Intelligent Bypass Switch

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

OCMR Optical Communications Mainframe with Redundant power supplies

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

ERX System Overview. The ERX System. This chapter provides information about the system.

Supported Hardware Components

MCF2xxx SERIES Multi-channel Modular Media Chassis

Industrial PoE Media Converter

Separate Video from Audio and Peripheral Data

DMP900 Digital Media Platform

Installing and Upgrading Internal Modules and FRUs

Datasheet IQ Modular Enclosures Flexible and Reliable Video and Audio Backbone

Cisco ASR 1001-X Router Overview

Chassis-based Media Converters

Installing the IPS 4345 and IPS 4360

Product Overview. Switch Descriptions. Front Panel CHAPTER

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

10 & 18 port SNMP and Modbus/TCP Capable Ethernet Switches SEC310-2SFP-T, SEC318-2SFP-T

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

Media Converters & Chassis

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

Installing the ASA 5550

Cisco Prisma II Platform

Hardened PoE Ethernet Switch

Datasheet. Gigabit Passive Optical Network. Models: UF-OLT, UF-Nano, UF-LOCO. GPON End-to-End Solution. High-Performance, Provider OLT

MediaKind G7 Series. High Performance Intel-based Video Processing

Datasheet. Gigabit Passive Optical Network. Models: UF-OLT, UF-OLT-4, UF-Nano, UF-LOCO. GPON End-to-End Solution. High-Performance, Provider OLT

IXIA IBYPASS HD DATA SHEET PROBLEM: INLINE TOOLS ARE A SINGLE POINT OF FAILURE IN THE NETWORK

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

H3C SecPath M9000-S NSQM2MPUD0 main processing unit

D9408 Advanced ATM Adapter

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

QuickSpecs. HPE Altoline 6921 Switch Series. Overview. HPE Altoline 6921 Switch Series

Cisco Series Gigabit Ethernet Half-Height Line Card

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

First of all, thank you for purchasing R2W series redundant power supply.

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

Ixia Net Optics ilink Agg xstream

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

ies8g COMMUNICATIONS Features Intelligent 8 Port Managed Gigabit Ethernet Switch Tel: Fax:

Product Overview. Switch Model

5U CWDM Managed Platform SML-5000

PT-7728/7828 Quick Installation Guide

TELCO. Tomi Männikkö/HW Architect, Datacenter R&D/ Nokia

Specifications Connectors. Chassis backplane consists of passive components. Single or optional redundant power supplies

The Conversion Technology Experts. Choosing a Fast Ethernet Media Converter

Quick Start Guide. Physical Description. The Port Status LEDs

Preface. Managed Media Converter Chassis System

Anue Net Tool Optimizer 5273

Operating instruction

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Models HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch

Junos WebApp Secure 5.0 Hardware Guide

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Prisma II Platform. Optoelectronics

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

Datasheet Gigabit Passive Optical Network Models: UF-OLT, UF-Nano GPON End-to-End Solution High-Performance, Provider OLT Low-Cost, Robust ONU CPE

ETHERNET SWITCHING PORTFOLIO

PRIMERGY BX900 System Unit

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X

Optimux-34, Optimux-25

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K.

EN port managed Ethernet switch with 8x10/100Base-T(X) and 2xGigabit combo ports, SFP socket

VCL-TP, Teleprotection Equipment

Quick Start Guide. Physical Description.

MACH100 19" Industrial Workgroup Rack-Mount Switches

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

Technical Specifications

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

Hardened Media Converter

Industrial Switches. Industrial switches. Copper cables Fiber optic cables Ring redundancy

6GK6024-8GS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

V C ALIANT OMMUNICATIONS. STM-1 Optical to STM-1 Electrical Converter. Data Sheet & Product Brochure U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

GigaVUE-2404 // Data Sheet

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Chassis-based Media Converters

CNGE2+2SMS[POE][HO] 10/100/1000 MBPS INTELLIGENT REDUNDANT RING GIGABIT SWITCH WITH OPTIONAL POE+ QUICK START GUIDE

Hardened Web-Smart High Power PoE Ethernet Switch

Datasheet Gigabit Passive Optical Network Models: UF-OLT, UF-Nano GPON End-to-End Solution High-Performance, Provider OLT Low-Cost, Robust ONU CPE

IES7110-2GS Series. Managed Industrial Ethernet Switch. User manual. Summarize. Panel layout. Packing list. Feature

Transcription:

DVBS November 13, 2009 1(12) LUMINATO CHASSIS Luminato web-site: www.telesteluminato.com

DVBS November 13, 2009 2(12) Luminato Chassis The Teleste Luminato chassis is a base for an IPTV modular platform and cable TV headends. Luminato enables the operator to setup a very compact headend configuration using various processing and interfacing modules. Luminato scales from one chassis headend in a box to a multiple chassis bigger headend system. Architecture of the Luminato platform enables very high performance with very low power consumption. Luminato architecture The Luminato chassis has 6 module slots for interface and processing modules. The Luminato architecture is future proof to support new module development later on by having all stream processing features in sub modules. Therefore, new functionality can be introduced later into the platform without touching the chassis.

DVBS November 13, 2009 3(12) The stream processing in Luminato is distributed to sub modules, which utilize virtually unlimited processing capacity in practical configurations, without problems typically caused with a central shared processor. All sub modules can process independently incoming streams. The internal router of the chassis makes the interconnection between sub modules and the payload gigabit Ethernet input and output ports. This means much less cabling at the headend and thereby simplifies headend configuration. The router also has a separate internal management network for sub modules and a chassis which guaranties reliable operation also in high-load situations. All internal connections are gigabit Ethernet which enables high-performance operation. Common management interfaces and power feeds for sub modules are also created in the chassis. High-density design The new component technology and selected architecture for Luminato creates a very high-density design, which saves a lot of rack space compared to traditional headend setups. Luminato can have up 12 receivers with descrambling capability in one chassis. If 6 quad receiver modules without descrambling are installed into the chassis, it increases the receiver count up to 24 in the chassis. Using quad ASI-modules means that one chassis can have up to 24 ASI inputs or ASI outputs. Installing six quad QAM modules means up to 24 QAM per chassis. The Luminato chassis can also have a mix of modules to adapt to the various application needs of the operator. Scalability In accordance with the Luminato system architecture, the video processing is performed on sub modules, which enables low-cost applications even with a partially equipped chassis, while having the performance scalability to a fully equipped chassis. The Luminato has virtually unlimited line speed capacity for stream processing in practical applications, which means that the Luminato chassis doesn t limit any practical configurations.

DVBS November 13, 2009 4(12) The chassis has two gigabit Ethernet ports for payload traffic. These ports can be used as inputs and output depending on the sub modules installed. The current release supports up to 1 Gb/s streaming, but later release will extend capacity 2x 1 Gb/s. There is no limit for the maximum amount of services in the chassis, which makes it possible to process a high amount of services in the same chassis. Practical setup can be from several tens of services up to 100 200 services in the same chassis. Using a multiple chassis in the headend scales setup can provide a virtually unlimited amount of services. Hot swap The sub modules can be swapped without power off the Luminato. Taking out one module doesn t affect other module operations at all. The chassis has centralized management for configuration, which enables automatic configuration recovery in case of a module swap. All this makes maintenance tasks easier and maximizes the service uptime. Easy installation The Luminato chassis is designed for 19 rack installation. It has mounting rails, which makes installation easy. Install the rails to the rack, and slide Luminato in place. All connectors are located on the backside. Managed cooling Luminato has managed ventilation, where internal temperature is actively monitored and fan speed is adjusted according to the required cooling capacity. Typically, fans rotate well below maximum speed, which increase their lifetime and generate less noise. The chassis cooling capacity is designed to support up to 100W heat dissipation, but typical setup takes less power. The fans can be replaced during live operation without service interruption. The fans are located behind the front panel. Power supply The chassis has a dedicated slot for replaceable power and input/output module. The power and input/output module has AC Power Supply, which supports 110 VAC and 240 VAC systems. Luminato supports also power supply redundancy. The power input/output module has secondary power supply DC voltage input for external backup power supply. Inputs and Outputs in Power module The Power and input/output module have two gigabit Ethernet SFP module slots for streaming payload traffic and IP inputs depending on the sub modules installed. The SFP module makes easy adaptation to electrical and fiber media to create interconnectivity from Luminato to other devices. The module has two management interfaces (100Base-T). The first one is typically used for general management purposes, and the second interface is dedicated connection to Conditional Access Servers. The USB port can be used for first time setup using terminal software through serial connection profile. Redundancy To minimize service outage because of hardware failure, Luminato supports 1+1 redundancy in the chassis level. To keep the Luminato platform as cost effective as possible, all internal redundancy features are minimized.

DVBS November 13, 2009 5(12) The pair of Luminato can be configured to act in main and backup schemes, where secondary Luminato monitors the main status. The secondary Luminato configuration is automatically synchronized with the main Luminato. The secondary Luminato stays in stand-by mode until failure occurs in the main Luminato. When the selected failure event trigs or the main unit is not responding, the main Luminato shuts down all payload outputs based on dedicated hardware circuitry to ensure switch off of all streaming. The secondary Luminato then takes over the stream processing operations. A virtual common IP address can be assigned to the pair of Luminatos to introduce them as one device to higher-level management software. Still, both devices can be accessed through their own IP address. Embedded DVB Content Protection Luminato has the capability to protect services with DVB scrambling. The chassis provides DVB Simulcrypt interface to Conditional Access systems, which allows integration with a large variety of CA vendors. The content protection has been designed to scale to a large number of scrambled streams with minimal system configuration. The actual scrambling is an integrated feature on the Luminato sub modules, which provides scalable performance and maximum flexibility of the system configuration, supporting both centralized and decentralized scrambling solutions. Any service can be scrambled simultaneously with multiple CA systems. Other advanced features include short-key change intervals, automatic PSI/SI table generation, detailed monitoring of the interaction with CA system, support of redundant ECM generators and scheduled changes of the content protection properties. Management The Luminato chassis has centralized management features for configuration and status monitoring of the sub modules and chassis. Management features are optimized for typical CATV or IPTV headend operations. There are many helpful features to make headend daily operation easy and effective. Intuitive WEBUI is designed for easy management and monitoring for troubleshooting. It allows the user to establish setup quickly just by entering a few parameters, and then let Luminato do the detailed configuration based on internal intelligence. There is still the possibility to also adjust the detailed configuration for professional users. Automatic service identification and PID remapping based on internal rules create unique values for all streams. Therefore, it is very easy to do the systemlevel configuration. CLI (Command Line Interface) is helpful to do configuration updates in patches and also makes it possible to manage Luminato through low-speed communication links. Monitoring parameters and warning/alarm messages are available using SNMP protocol and traps. This allows integration to the element management system or higher-level management systems. The front panel has an indicator to get a quick overview status of Luminato. When all indicators show green, then everything is running as expected. Also, all sub modules have status indicators for module operation and interface

DVBS November 13, 2009 6(12) indicators for signal status. Indicator lamps are helpful to locate interface or a module that requires action. Features 6 processing and interface module slots 19 1RU rack mechanics Installation rails for easy installation Slot for Power Supply and I/O module Power Supply Redundancy USB port for initial setup 2x gigabit Etherent ports (SFP modules) for payload 1+1 chassis redundancy Intuitive WEB user interface Automatic SID and PID remapping CLI (Command Line Interface) SNMP monitoring and traps DVB Simulcrypt

DVBS November 13, 2009 7(12) Technical specifications Parameter Specification Note Luminato Chassis (LCH-A-XXXX) Sub module slots 6 supports hot swap Fans 4 replaceable Cooling capacity 100 W Dimensions (note 1) 44 mm x 483 mm x 385 mm h x w x d Installation rails 492 900 mm Installation depth Weight 3,5 kg Enclosure classification IP21 Operating temperature range -10...+55 C Storage temperature range -30...+70 C EMC compatibility EN 50083-2 Management interfaces WEB Browser User Interface IE7.0 or Mozilla Firefox 3.0 (or newer) CLI SNMP version 2 and version 3 note 5 Software Upgrade methods Windows File system or TFTP DVB Common Scrambling Algorithm Content Protection Max service to be scrambled 720 note 4 Max EMM bitrate 1 Mb/s Luminato Power Supply (LPS-BX-X) Power consumption 120 W max Internal Supply Voltages 24 V / 4200 ma LPS-B External Power supply 24 V / 4200 ma LPS-C Connectors, 110-230 VAC IEC 3 pins Payload Gigabit Ethernet 2 x SFP modules Management 2 x RJ-45 100Base-T External PSU Phoenix contacts MC 1,5/ 2-ST-3,5 SFP modules note 2 First time setup mini USB serial profile Dimensions (note 1) 40 x 109 x 252 mm h x w x d Weight 0,5 kg Enclosure classification IP21 Operating temperature range -10...+55 C note 3 Storage temperature range -30...+70 C EMC compatibility EN 50083-2

DVBS November 13, 2009 8(12) Notes 1) Dimensions excluding connectors and locking screws. 2) Luminato is verified to operate with Apac Electronics SFP-modules 3) Full specification is met 0 +45 C 4) Chassis total capacity, when 6 processing module in use. 5) Supported MIBs: MIB2-SYSTEM TELESTE-ROOT-MIB TELESTE-COMMON-MIB DVB-MGSYSTEM-MIB DVB-MGSIGNALCHARACTERISTICS-MIB LUMINATO MIB Monitoring Functions Chassis Temperature Fan failure Luminato Power Supply PSU load (total current) Overload alarm Low voltage alarm Backup power supply

DVBS November 13, 2009 9(12) Ordering Information Luminato Chassis Order Code: LCH-A-X-XXXX - includes 6 slot chassis with PSU/Interface slot, 4 fans - installations rails and screws - USB cable - CD ROM with manuals Luminato Chassis options LCH-X-A-XXXX module assembly service - Sub modules are installed at factory to chassis - Module locations must be specified in ordering LCH-X-X-XXSX DVB Simulcrypt content protections - Enables DVB simulcrypt interface to CAS systems LCH-X-X-XXXP PSI/SI editor - Enables PSI/SI table editor, that can be used to create PSI and SI tables manually. This is useful if a special descriptor is needed to be inserted in the tables. Another usage would be to create SI table streaming. - PSI tables: PAT,PMT,... - SI tables: SDT,NIT,

DVBS November 13, 2009 10(12) Accessories Power Supply and Input/Output module This module has a main power supply for the Luminato chassis The module has connectors for: - Mini USB for initial setup. Any terminal software can be used through serial port profile. - 2x 100 Base-T for management (MGMT1, MGTM2) - 2x Gigabit Etherner SFP module slots for video streaming (GE1, GE2) NOTE: recommended to Apac Electronic SFP-modules (ordering codes below) - 24 VDC input for secondary power supply (automatic switchover, if main power supply fails - I/O connectors for redundancy purposes or contact closures or switch detection Order Code: LPS-BX-X Power Supply 100W, I/O connectors Power Supply Option options LPS-XX-A module assembly service - Sub module is installed at factory to chassis Power Cords: LPS-XA-X Power Cord, Euro Plug LPS-XB-X Power Cord, UK Plug LPS-XD-X Power Cord, India Plug

DVBS November 13, 2009 11(12) SFP modules for payload ports GE1 and GE2. Order Code Description Additional info Note LSFP-A-X LSFP-B-X Electrical CAT5 (100m) 10/100/1000Base-TX SFP module Optical MMF 850nm (550m) 1000Base-FX SFP module RJ-45 connector Dual LC optical connector SGMII-module, select Electrical only from user interface SERDES-module, select Fiber Compatible from user interface LSFP-C-X LSFP-D-X LSFP-E-X LSFP-F-X LSFP-G-X Optical MMF 1310nm (2km) 1000Base-FX SFP module Optical SMF 1310nm (10km) 1000Base-FX SFP module Optical SMF 1310nm (30km) 1000Base-FX SFP module Optical SMF 1550nm (70km) 1000Base-FX SFP module Electrical CAT5 (100m) 1000Base-TX SFP module Dual LC optical connector Dual LC optical connector Dual LC optical connector Dual LC optical connector RJ-45 connector SERDES-module, select Fiber Compatible from user interface SERDES-module, select Fiber Compatible from user interface SERDES-module, select Fiber Compatible from user interface SERDES-module, select Fiber Compatible from user interface SERDES-module, select Fiber Compatible from user interface SFP module options LSFP-X-A module assembly service - SFP-module is packed into Luminato chassis accessory box to chassis at factory Cover plates NOTE: Cover plate must be installed to unused slot to keep ventilation operating as designed. Order Code: LCP-A

DVBS November 13, 2009 12(12) External power supply PSU is used as a redundant power feed to the Luminato Chassis. PSU can be installed to the external chassis or Luminato chassis (Note: requires two slots). PSU module has 6 DC outputs. Order Code: LPS-CX-X Backup Power 100W External power supply options LPS-XX-A module assembly service - Sub module is installed at factory to chassis Power Cords: - LPS-XA-X Power Cord, Euro Plug - LPS-XB-X Power Cord, UK Plug - LPS-XD-X Power Cord, India Plug External Power Supply chassis Order Code: LCH-C-X-XXXX standalone chassis for one redundant PSU. Chassis can be installed either rack mount or wall mount - Create cover for LPS-CX-X - Forced ventilation