NI 6521 Specifications

Similar documents
OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

You need the following to set up and use your terminal block:

Electrical. SPECIFICATIONS SH Cable

INSTALLATION INSTRUCTIONS LFH160 Cable

SH Cable Specifications

NI SD Card Memory Module

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

NI SMB-2145/2146/2147/2148

NI PXI-2567 Specifications

Getting Started with the NI 8234

SCC-RLY01 Relay Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

Getting Started with the NI PCIe-8253

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

Getting Started with the NI PCIe-1433

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

SCC-AO10 Isolated Analog Output Module

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

USER GUIDE Universal Motion Interface (UMI)-7764

FP-PS-4. Features. Installation

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

Getting Started with the NI PCIe-8235

Getting Started with the NI PCI-8254R

Getting Started with the NI PCI-1405

Getting Started with the NI PXI/PCIe-8231

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

Getting Started with the NI PCIe-8255R

Getting Started with the NI 8234

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

NI 653x Cable Adapter

NI 6584R User Guide and Specifications

NI 6520/6521. Contents USER GUIDE

NI PCIe-8255R Quick Start Guide

NI PXI-1042 Series Power Supply Shuttle

NI Serial Hardware Specifications Guide

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

Getting Started with the NI PXI/PCI-1422

FP-AO-200 AND CFP-AO-200

FP-AIO-600 and cfp-aio-600

CompactRIO Reconfigurable Embedded Chassis

FP-AO-210 AND CFP-AO-210

Getting Started with NI-Motion for NI 73xx Motion Controllers

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

Getting Started with the NI PXI/PCI-1409

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sourcing Digital Output Device

TBX-96 TERMINAL BLOCK

VME-GPIB Installation and User Guide

Getting Started with the NI EVS-1463

Compact FieldPoint cfp-cal

Getting Started with the NI EVS-1464

NI 6581/6581B Specifications

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

RTM Contents. Definitions. Conditions SPECIFICATIONS. PCI Express Rear Transition Module for ATCA

Fiber-Optic MXI-Express x4 for PXI Express (Compatible with NI, Dell, and Hewlett-Packard PCs)

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

1-Wire 4 x 128 Matrix Terminal Block for the NI PXI/PXIe-2532B

NI USB-9201/9221. Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 12-Bit Analog Input Devices

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

RTM Contents. Definitions. Conditions SPECIFICATIONS. High-Speed Serial Rear Transition Module for ATCA

QUICK START GUIDE. What You Need to Get Set Up

Getting Started with R Series Multifunction RIO

Getting Started with R Series Intelligent DAQ

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Calibrating FieldPoint Analog Input Modules with Calibration Executive

SCXI -1313A Terminal Block

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

FP-2000/2010 FieldPoint Quick Start Guide

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

NI PXIe-7971R. Contents DEVICE SPECIFICATIONS. NI FlexRIO FPGA Module for PXI Express

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

NI PXIe-7976R. Contents DEVICE SPECIFICATIONS. NI FlexRIO FPGA Module for PXI Express

illustrate the performance of a representative module.

8 AI (12-Bit, 10 ks/s), 2 AO (150 Hz), 12 DIO USB Multifunction I/O Device

Compact Vision System with USB3 Vision and Reconfigurable I/O

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, Sinking Digital Input/Sourcing Digital Output Module. ni.

Getting Results with the NI PXI-6585R

USB Definitions. Conditions. Analog Input SPECIFICATIONS. 8 AI (10 ks/s), 4 DIO USB Multifunction I/O Device

1- or 2-Port, High-Speed/FD, USB CAN Interface Device

These specifications apply to the 1 m and 3 m TriaxM-TriaxM. it in a manner not described in this document.

INSTALLATION GUIDE AND SPECIFICATIONS PXIe-4844

FieldPoint cfp-21xx. Quick Start Guide. What You Need to Get Set Up

NI crio-9101/9102/9103/9104

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

Note Using the PXIe-7915 in a manner not described in this document might impair the protection the PXIe-7915 provides.

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

Transcription:

NI 6521 Specifications This document lists specifications for the NI 6521 device. All specifications are subject to change without notice. These specifications are typical at 25 C unless otherwise noted. Certification... UL listed Maximum working voltage Channel-to-channel... 150 V Channel-to-earth... 150 V, Measurement Category II Caution This module is rated for Measurement Category II and is intended to carry signal voltages no greater than 150 V. This module can withstand up to 1,500 V impulse voltage. Do not use this module for connection to signals or for measurements within Categories III or IV. Do not connect to MAINS supply circuits greater than 150 VAC. Refer to the NI 6520/6521 User Guide for more information about measurement categories. When hazardous voltages (>42.4 V pk /60 VDC) are present on any signal, all signals must be considered hazardous. Ensure that external wiring or any circuits connected to the device are properly insulated from human contact. Caution This product must be used with special keyed cables and accessories. Refer to the Accessories section of this document and the 37-Pin High-Voltage Accessory Safety Kit Installation Guide shipped with your device for more information. Caution Use the PXI-6521 in a PXI chassis with properly installed PXI filler panels. Do not remove the filler panels from the PXI-6521. Doing so can result in electrical shock or death. Digital I/O Number of channels...16 (eight optically isolated digital input channels and eight non-latching relay output channels) Data transfers...interrupts, programmed I/O I/O connector...37-pin keyed male D-SUB Isolated Inputs Number of input channels...8 (each bipolar and isolated from other channels) Configuration...8-channel optically isolated digital inputs Input voltage range... 30 VDC to 30 VDC, P0.X+ to P0.X ; 150 V, channel-to-earth 1 Caution The PCI-6521 must be installed in a PC that adequately grounds the front panel bracket to the chassis of the PC. Caution Do not remove covers from the PCI-6521. Doing so can result in electrical shock or death. 1 The voltage added on P0.X+ can reach up to 150 VDC. The voltage added on P0.X can reach up to 150 VDC. However, the voltage drop from P0.X+ to P0.X should be limited within ±30 VDC.

Isolation Channel-to-channel...60 VDC continuous 1 Channel-to-bus...150 V continuous 2 Channel-to-earth...150 V continuous 3 Digital logic levels Input current Level Min Max Input low voltage 0 VDC ±4 VDC Input high voltage ±11 VDC ±30 VDC 11 V inputs...4.5 ma/channel max 30 V inputs...12.5 ma/channel max Propagation delay...45 μs typ Electromechanical Relay Outputs Number of channels...8 Configuration...3-channel SPDT, non-latching; 5-channel SPST, non-latching Relay types...3 non-latching SPDT (Form C), 5 non-latching SPST (Form A) Power-on state...de-energized, default; user-programmable to de-energized or energized Note The response time of programmable power-up states is 400 ms. Default power-off state...relays de-energized Caution The maximum switching current is limited by the maximum switching power, the maximum voltage, and must not exceed 60 W/60 VA. Contact rating Maximum switching power...60 W/60 VA Maximum voltage (AC)...150 VAC, CAT II Maximum Current (Amps) Maximum voltage (DC)... 150 VDC, CAT II Maximum current PXI-6521 (per channel)... 2 A 4 PCI-6521 (per channel)... Refer to Figure 1 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0 5 10 Figure 1. Maximum Current for Ambient Temperatures 55 C DC path resistance Initial... <0.2 Ω typ End of life... 1.0 Ω typ Relay operate time... 2 ms typ 4ms max Expected relay life Mechanical... 100,000,000 cycles Electrical 30 VDC, 1 ADC resistive... 500,000 cycles 30 VDC, 2 ADC resistive... 100,000 cycles 125 VAC, 0.2 AAC resistive... 300,000 cycles 125 VAC, 0.5 AAC resistive... 100,000 cycles Power Requirement PXI-6521 15 20 25 30 35 40 Ambient Temperature ( C) External PC Ambient All Channels 3.3 V (±5%)... 100 ma max 5 V (±5%)... 300 ma typ, 500 ma max PCI-6521 5 V (±5%)... 400 ma typ, 600 ma max 45 50 55 1 Verified by 620 Vrms dielectric withstand test, 5 s. 2 Verified by 1,400 Vrms dielectric withstand test, 5 s. 3 Verified by 850 Vrms dielectric withstand test, 5 s. 4 All relay channels external PXI chassis ambient, up to 55 C. NI 6521 Specifications 2 ni.com

Physical Characteristics PXI-6521 Dimensions... 16 cm 10 cm (6.3 in. 3.9 in.) Weight... 150.0 g (5.0 oz) PCI-6521 Dimensions... 17.5 cm 9.9 cm (6.9 in. 3.9 in.) Weight... 170.0 g (6.0 oz) Pin Assignments P1.1NO P1.1COM P1.1NC P1.3NO P1.3COM P1.5NO P1.5COM P1.7NO P1.7COM NO CONNECT P0.1+ P0.1 P0.3+ P0.3 P0.5+ P0.5 P0.7+ P0.7 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 P1.0NO P1.0COM P1.0NC P1.2NO P1.2COM P1.2NC P1.4NO P1.4COM P1.6NO P1.6COM NO CONNECT P0.0+ P0.0 P0.2+ P0.2 P0.4+ P0.4 P0.6+ P0.6 Figure 2. NI 6521 Pin Assignments Accessories (PXI-6521 Only) TB-2621, High-Voltage CAT II 150 V 37-Pin Front-Mounting PXI Terminal Block... 779444-01 SH37F-37M-2 37-Pin Female-to-Male Shielded I/O Cable, 2 m... 778621-02 SH37F-37M-1 37-Pin Female-to-Male Shielded I/O Cable, 1 m... 778621-01 CB-37F-HVD 37-Pin High-Voltage DIN Rail Mountable Terminal Block...779491-01 37-Pin High-Voltage Accessory Safety Kit...779445-01 TB-37F-37CP 37-Pin Crimp and Poke Terminals...779185-01 Environmental The NI 6521 device is intended for indoor use only. Operating Environment Ambient temperature range...0 to 55 C IEC-60068-2-1 and IEC-60068-2-2) Relative humidity range...10 to 90%, noncondensing IEC-60068-2-56) Altitude...2,000 m (at 25 C ambient temperature) Pollution Degree...2 Storage Environment Ambient temperature range... 20 to 70 C IEC-60068-2-1 and IEC-60068-2-2) Relative humidity range...5 to 95%, noncondensing IEC-60068-2-56) Shock and Vibration (PXI-6521 Only) Operational shock...30 g peak, half-sine, 11 ms pulse IEC-60068-2-27; test profile developed in accordance with MIL-PRF-28800F) Random vibration Operating...5 to 500 Hz, 0.3 grms Nonoperating...5 to 500 Hz, 2.4 grms Random vibration is tested in accordance with IEC-60068-2-64. The nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3. National Instruments Corporation 3 NI 6521 Specifications

Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC 61326): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment, visit ni.com/environment/weee. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) Note For EMC compliance, operate this device with shielded cabling. CE Compliance This product meets the essential requirements of applicable European Directives as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. NI 6521 Specifications 4 ni.com

Where to Go for Support The National Instruments Web site is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/ calibration. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/ support and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725 72511, France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 328 90 10, Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886, Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377 2222, Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545 National Instruments Corporation 5 NI 6521 Specifications

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 2005 2009 National Instruments Corporation. All rights reserved. 371607B-01 Aug09