Detailed procedures, operation instructions, maintenance, and emergency contact information list is attached.

Similar documents
Chromatography Software Training Materials. Contents

Agilent GC/MSD Instructions

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

PerkinElmer Series 200 HPLC: Operating Procedure

ChromQuest 5.0 Quick Reference Guide

Manual HPLC-4 Alliance-UV

Chromeleon software orientation

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

Equipment Overview: Safety:

Agilent G2070BA GC ChemStation

How to Run the CASPiE GCMS

3 Starting the chiral HPLC and logging into LC Real Time Analysis.

FROG-4000TM Quick Start Guide

Agilent Intuvo 9000 Gas Chromatograph

For additional information, see these documents on the Breeze 2 software DVD:

Data Acquisition with CP-2002/2003 Micro-GC Control

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017

Agilent 7890 Series Gas Chromatograph

HITACHI LACHROM ELITE

Automated Submission for Analysis Processing (ASAP) Operator s Guide Dionex Corporation

Soprane II Documentation

Agilent 7820A Gas Chromatograph

Introduction to the HPLC ChemStation and Acquisition

Karl Suss SB6 Bonder Operation Tool Id: Rev 01, 09/24/10

ABB Analytical ABB Process Analytics. VistaII. Model 2000 Process Gas Chromatograph

Operation of the Toxic Organic Chemical Air Monitor (TOCAM ) with the Ellvin Chromatography Software

User Guide File Transfer Scheduler. LINAX Series LINAX A310 CAMILLE BAUER

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

Chromeleon-PA Analyzer User s Guide Dionex Corporation

4 Instrument Instructions for CE

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Agilent GC, MS, and ALS

Galaxie Workstation Configuration Manager

Using SIMDIS Expert 9 (Separation Systems) with Clarity

Agilent MassHunter Easy Access Software

TraceFinder Acquisition Quick Reference Guide

Samples Preparing the GC to run samples Running samples - Manual Injection Running samples - GC ALS or Valve Injection

Dionex AS-AP Sample Conductivity and ph Accessory Setup and Operation Guide

Sciex QTrap Operational Steps for Trained Personnel

UniPoint System Software User s Guide

Steps for LCMS-8040 Triple Quadrupole

Standard Operating Procedure for the Beckman PA/CE MDQ Electrophoresis System. Last Modified October 19, 2012

Montgomery County Community College Document Number: DP DeKalb Pike Revision Number: 2. Page 1 of 9 SOP: BioLogic LP Chromatography System

IONSCAN -LS. Quick Start Guide. Revision A, April 2005 Part Number USA

Videographic Recorders

Data Acquisition with 3400/3600 GC Control

FlowAccess TM GETTING STARTED. Windows software for Skalar SAN plus systems. Version and up

Aqueous GPC Instructions - Detailed

TraceFinder Acquisition Quick Reference Guide

TraceFinder Administrator Quick Reference Guide

A. About this Manual

TraceFinder Analysis Quick Reference Guide

Agilent 7890B Gas Chromatograph

Data Acquisition with 3800 GC Control

Quick Setup Instructions for the Knauer HPLC-System. Quick Setup Instructions for the Knauer HPLC-System For windows XP (using CHANCE vers. 2.

Tutorial EN

EZ IQ. Chromatography Software PN P1A

Procedures for Group Quantitation

Technical Procedure for X-Ray Fluorescence Spectrometer (XRF)

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Title: Bruce Furnaces Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 02/21/06

Waters 600E Multisolvent Delivery System Quick Start Guide

Clarity. Clarity Demo. Code/Rev.: M003/60A Date: Fax: Petrzilkova 2583/ Prague 5

Thermo. EASY-nLC User Guide for LC Devices

Breeze 2 Installation and Configuration Guide

Fatty Acid Methyl Ester (FAME) RTL Databases for GC and GC/MS

Procedures of the simaa 6000 (perkin elmer verison 2.5 aa winlab) Simultaneous multi-element graphite furnace Atomic absorption spectrophotometer(aa)

EHS Assistant: Chemical Inventory Users Guide

Netzsch TGA Training Notebook

GE Healthcare. Getting Started with

Direct Image Viewer User Tutorial

NMR INSTRUMENT INSTRUCTIONS: Safety and Sample Preparation

QAM-I-102 Operation and Calibration of the Autoanalyzer

Agilent 6100 Series Quad LC/MS System

Quick Guide to the Star Bar

EnCal 3000 Gas Chromatograph Software Manual d

Chromatography Systems News Flash

CyAn ADP Guide. Starting Up

Gas Chromatograph Software Interface User Manual (for FloBoss 107)

Agilent 1290 Infinity with ISET

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Laboratory Safety Guideline Laboratory Safety Data Sheets (SDS) Management, Understanding, Preparation

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

UT Martin Environmental Health & Safety Safety Procedure

HT3X00A. Clarity Control Module. Code/Rev.: M153/50E Date: 11/13/2018. Fax: Petrzilkova 2583/ Prague 5

Malvern Zetasizer Nano Basic Operating Instructions 08/14/2015 S.V.

DESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows

Guidebook for Installation and Familiarization. HP 1100 Series Combinatorial Chemistry Analysis System

GX-2009 Data Logger Management Program Operator s Manual

Dissolution System Drivers Operation Manual Rev. D

Agilent ICP-OES SVS 2 Productivity Package Installation and Upgrade Instructions

Dash Jr. User Manual Table of Contents

9 Maintenance and Repair

FlowAccess TM V3 USER MANUAL. Windows software for Skalar SAN plus systems. Version and up

Getting Started. Environmental Analysis Software

PANALYTICAL X PERT PRO XRD

Installation instruction for MVA-20: 894 Professional CVS fully automated for CVS determinations. Content

Chromeleon / MSQ Plus Operator s Guide Document No Revision 03 October 2009

Data Handling and Reports

Quick Start Guide. Introduction. Importing Raw Data. Method 1: Use Open Data Panel

Transcription:

GC/FID Standard Operating Procedure Environmental health and Safety (EH&S) 2809 Daley Drive Ames, IA 50011-3660 Phone: (515)-294-5359 Fax: (515)-294-9357 www.ehs.iastate.edu Procedure: Department: Bioeconomy Institute Building/ Room Number: BRL 1115 Supervisor: Jacqulyn Baughman Procedure Overview: Health and safety information for materials used: Proper PPE needs to be worn while handling chemicals that are tested. Compressed gas cylinders are used. Hazard Control Measures: Safety glasses and lab coat Latex or nitrile gloves (for handling samples) Waste Disposal Procedures: Biodiesel can be placed into appropriate waste containers. Decontamination Procedures: None Spill Containment and clean up procedures: None Using substances requiring special procedures: No Written By: Pedro Ortiz Date: 4/25/2008 Revised By: Zach Bartlett Date: 6/10/2011 Approved By: Date: Detailed procedures, operation instructions, maintenance, and emergency contact information list is attached.

Equipment Description: The Varian 430-GC is a single-channel chromatography instrument that is used to analyze gas phases of liquid or headspace samples. It is equipped with a flame ionization detector (FID), and a water-stable wax chromatography column from Restek, although the columns on this instrument are interchangeable. UHP/zero helium gas is used as a carrier (mobile phase), while UHP/zero hydrogen and breathing-grade air are used to generate a flame inside the detector. The GC is controlled from a computer with a software package called GALAXIE Chromatography Data System. This software is used to control the GC and for data acquisition. Potential Hazards: There are no specific hazards related with this equipment but some caution needs to be taken with the surrounding equipment (e.g. gas cylinders, hazardous chemicals, electrical outlets, etc.) Compressed cylinders used are: helium, hydrogen, and air The auto-sampler system contains moving parts that are controlled by the automation. Keep extremities away from the needle and the moving parts. Start-Up Checklist: Make sure that the carrier gas cylinders (helium, hydrogen, and air) are open and set to 80, 40, and 40 psi respectively. If the total pressure of any of the cylinders is at 500 psi or below, notify the supervisor so that a replacement cylinder can be timely ordered. Should be able to see the green lights on the front face of the instrument showing it is ON and READY. If a red light shows, the common practice is to restart the instrument by turning the power switch OFF and ON. Make sure the solvent vials on the auto-sampler contain enough of the corresponding solvent for the tests to be performed. Vial I should be filled with HPLC grade methanol and vial III filled with deionized water. Instrument Operation: 1. Start Up a. To start up the GALAXIE software, double click on the GALAXIE icon on your desktop. b. Enter your assigned username in the space identified as User Identification, and click ok. If a GALAXIE window is already open, but not running on a sequence, click Session>New Login. c. The program will initialize and show a blank Data screen. d. Start the communication with the Varian 430-GC by checking the box as identified Varian 430-GC-R box located on the systems tab. e. Then the default screen will show the activity of the detector and the Status overview. Here you can check the status of the system. The system needs to be Ready in order to run samples. Note: Browse through the different windows in the program by using the Data, Systems, and Calibration tabs at the bottom left part of your screen. Sampling: 1. Starting a new sequence a. If you already have a saved sequence, go to Opening an existing sequence.

b. Go to the top taskbar in the GALAXIE interface and click on File>New>New Sequence. c. The New Sequence Wizard will open and will ask to select the system, number of samples (you can always add or delete lines later), and a file name. d. Fill the required spaces and click the Next to go to the next screen and then click OK. The Sequence will appear on the Data tab, showing the status and the options. e. New lines can be added with the plus sign button and deleted from bottom up using the minus sign button. Each line represents a sample to be taken and analyzed. Opening an existing sequence: a. A sequence is a list of samples to be analyzed including the information on the file names and analytical methods to be used. Setting up a new sequence is not always necessary; if a sequence was previously saved it can simply be loaded to analyze a similar set of data. Make sure you include a short description about the application of the particular sequence. b. Go to the top taskbar in the GALAXIE interface and click on File>Open>Open Sequence. c. Select the previously saved sequence you want to use from the data directory. Setting up a sequence and sample analysis: a. Select an analytical method from the Method drop down menu arrow of the first line. After selecting the method, all the settings needed show their method default values on this line. b. Here you can select a prefix, ID, and suffix for the filenames of the chromatograms. The preferred values are the default ones-the sample ID associated with the vial. If it is absolutely necessary to change the filename extensions like the prefix, click on the three dot button on the first line of the RunName(prefix) column. This will open the Token run name window, where you can select the parameter to be used as filename prefix by double clicking on the name. c. You can also choose to use any custom name by writing it down on the Define run name formula block. For example: if you choose the date and time of the run as your filename double click where it say StartRunTime and the ok button. d. Make the RunID(suffix) column blank for all samples. e. Select the number of injections you would like to be performed. Three is standard. f. Make sure the vial number matches up with the number on the auto-sampler tray. This Step is Critical. g. It is recommended that the last line in the sequence is the Standby method. The reason for this is to stop the consumption of air and H2. h. Now you can select the method for each line manually or you can copy the method selected on the first line for other lines. i. To start analyzing samples simply click on the green Play button located at the top of the sequence list. j. If the temperature set-points on the sequence do not match with current temperatures the sequence will not start immediately. If the actual temperatures are the Standby or Bakeout temperatures the GC will take approximately 5 minutes to stabilize. k. To stop the automation click on the navy Stop button, if you want to close the sequence you will need to then click on the red Stop button that appears once you stop the automation. Reading individual results:

a. On the Galaxie software each chromatogram can be opened individually to read the results. b. On the top taskbar of the GALAXIE window click File>Open>Open Chromatogram c. Then go to the folder where the data was saved and look for the particular chromatogram you want to look at. The data is organized in folders identified by all three: username, month and year of test. d. Once the desired chromatogram is open, click on results. The chromatograms and the table of results will be located on the right side of Data tab. On the results table the quantity (v/v) column corresponds to the concentration of the gas identified on that line and the Time (Min) corresponds to the retention time. For any unknowns note the retention time since this might be useful to later determine what these signals mean. Calibration verification a. Use a single or a set of standard solutions to check the calibration on the desired method. b. Set up a line on your sequence where you analyze using the analytical method and test the standard as an unknown and indicate the appropriate vial number on the tray. Typically the standard for verification is injected 3-4 times. c. To see the results follow the Reading results procedure below. The final results should show the correct peak identification and concentrations (Quantity v/v) on the standards as prepared. If the results do not match take note of your findings and notify a supervisor. Shutdown a. Make sure you keep the work area clean at all times. b. The 430-GC should remain turned on at all times but the computer may be shut down if instrument is left unused for long periods of time (e.g. weekends). c. Make sure the instrument is left on Standby method keeping the temperatures low, the injector heaters off, and the flame and detector turned off. d. Close the main valves of the H2 and air cylinders. This will help saving these gases while the instrument is on Standby. Maintenance a. Sometimes the software could show some errors related with the set-up of a sequence. Follow the onscreen instructions to fix the problem. b. If the computer loses communication with the instrument it will show an error both on the screen and on the front panel LED. If this is the case try restarting the computer. If this does not fix the problem contact the supervisor. c. Proper care of the equipment is necessary to prevent any malfunction and unscheduled maintenance. d. Internal components of the 430-GC are non-serviceable. Maintenance work for this equipment is to be performed by a Varian Inc technician.

Emergency Contacts Dustin Dalluge Knife Mill Supervisor/Operator Office: (515)294-9451 Jacqulyn Baughman Lab Supervisor Office: (515) 294-9451 Cell: (414) 460-5776 Ryan Smith BEI Program Coordinator Office: (515) 294-6244 Cell: (515) 203-1640 Home: (719) 660-2262 Dr. Robert Brown BEI/CSET Director Office: (515) 294-7934 Cell: (515) 520-1337 Home (515) 460-3434 Approved Trainers: Dustin Dalluge, Zach Bartlett, Adrian Ramirez Training Sign-Off Trainee Date Trainer