This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

Similar documents
Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics controllers V C30B and V T40B.

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics controller model V T2.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Vision OPLC. V T38 Installation Guide. General Description

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

Vision OPLC. General Description.

Vision OPLC V TR20

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

The identified danger could cause physical and property damage.

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Vision OPLC. General Description. Installation Guide V T34.

Vision OPLC V TR6/V350-J-TR6

EX-RC1 Remote I/O Adapter

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

OPLC Installation Guide

High Speed Remote I/O Module

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision OPLC V TR20

V TU24 V350-J-TU24

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Micro-OPLC Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed

V E1B Snap-in I/O Module

V E2B Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

EX-RC1 Remote I/O Adapter

Vision OPLC V TR20/V350-J-TR20

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

UniStream. Built-in. Installation Guide: US7-B5-B1, US7-B10-B1, US7-B5-TR22, US7-B10-TR22, US7-B5-T24, US7-B10-T24

EX-RC1 Remote I/O Adapter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

UniStream HMI Panel. CPU-for-Panel

UniStream CPU-for-Panel

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

V E5B Snap-in I/O Module

V E62B Snap-in I/O Module

High Speed Remote I/O Module

V E2B Snap-in I/O Module

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Component identification

User safety and equipment protection guidelines

V E1B Snap-in I/O Module

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

V E6B Snap-in I/O Module

V E3XBW Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision570 TM /560 TM. Color OPLC TM. Color Vision570 TM /560 TM Series Featuring:

1210 TM /1040 TM. Features: V1210 Flat Panel. V1040 Classic Panel HMI PLC. Communication

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

IO-DI8-RO4, IO-DI8-RO4-L I/O Expansion Modules 8 Inputs, 4 Outputs

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

IO-DI16, IO-DI16-L I/O Expansion Modules

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Item SM35-J-T20 SM43-J-T20 SM70-J-T20

V350-T38 V350J-T38.

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

V E4XB Snap-in I/O Module

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

Vision OPLC. Distributed by: M.A. Selmon Company, Inc 4 Oxford Rd. Milford, CT V R34/V350-J-R34 Technical Specifications

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

Vision OPLC. V TR6 Technical Specifications. Technical Specifications.

Samba PLC+HMI SM35-J-RA22

V E3XB Snap-in I/O Module

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

Unitronics Devices and RS485 Table Of Contents

V430J-TR34 V350-TR34 V350J-TR34. pnp inputs

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

UniStream Uni-I/O Modules

UniStream HMI Panel. Max. current consumption 1.

V350-RA22 V350J-RA22.

10 x Digital inputs, 24VDC, sink/source 2 x Analog inputs, 0 10V / 0 20mA, 12 bits

UAG-XKPxxx Yes 16, in addition to any modules installed on the panel UAG-CX-XKPxxx. Yes 16

V E3XB Snap-in I/O Module

Vision OPLC. Technical Specifications. V T34 Technical Specifications


UniStream Uni-I/O Modules

FX1N-2EYT-BD Output Expansion Board

UniStream Uni-I/O Modules

Transcription:

Vision OPLC Installation Guide Models V230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens). General Description Vision OPLCs are programmable logic controllers that comprise an integral operating panel containing a graphic LCD screen and a keyboard. All models offer the same PLC features. Operating panel features differ according to model. V230 LCD + Keyboard V260 LCD + Keyboard V280 Touchscreen + Keyboard V290 Touchscreen only Communications 2 serial ports: RS232 (COM1), RS232/RS485 (COM2) 1 CANbus port The user can order and install an additional port. Available port types are: RS232/RS485, and Ethernet Communication Function Blocks include: SMS, GPRS, MODBUS serial/ip Protocol FB enables PLC to communicate with almost any external device, via serial or Ethernet communications I/O Options Vision supports up to 256 digital, high-speed, and analog I/Os via: Snap-in I/O Modules Plug into the back of the controller to provide an on-board I/O configuration I/O Expansion Modules Via adapter, local or remote I/Os may be added via expansion port or CANbus Information Mode Programming Software, & Utilities This mode enables you to: Calibrate the touchscreen View & Edit operand values, COM port settings, RTC and screen contrast/brightness settings Stop, initialize, and reset the PLC To enter Information Mode, press the touchscreen and maintain contact for several seconds. The Unitronics Setup CD contains VisiLogic freeware and other utilities VisiLogic Easily configure hardware and write both HMI and Ladder control applications; the Function Block library simplifies complex tasks such as PID. Write your application, and then download it to the controller via the programming cable included in the kit Utilities These include UniOPC server, Remote Access for remote programming and diagnostics, and DataXport for run-time data logging To learn how to use and program the controller, as well as use utilities such as Remote Access, refer to the VisiLogic Help system. Unitronics 1

Vision OPLC Models V230/260/280/290 (Non-color Screens) Operand Types Memory Bits 4096 Memory Integers, 16-bit, 2048 Long Integers, 32-bit, 256 Double Word, 32-bit unsigned, 64 Memory Floats, 32-bit, 24 Timers, 32-bit, 192 Counters, 16-bit, 24 For additional product documentation, check the Technical Library, located at www.unitronics.com and on the Unitronics Setup CD. Technical support is available at the site, and from support@unitronics.com. Standard Kit Contents Vision controller Programming cable + RS232 adapter Mounting brackets (x4) Grounding hardware 3 pin power supply connector Rubber seal 5 pin CANbus connector Extra set of keyboard slides, according to model CANbus network termination resistor Unitronics Setup CD Danger Symbols When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Danger The identified danger causes physical and property damage. Warning The identified danger could cause physical and property damage. Caution Caution Use caution. Before using this product, the user must read and understand this document All examples and diagrams are intended to aid understanding, and do not guarantee operation Unitronics accepts no responsibility for actual use of this product based on these examples Please dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels To avoid damaging the system, do not connect/disconnect the device when power is on Environmental Considerations Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration, in accordance with the standards given in the product s technical specification sheet Ventilation: 10mm space required between controller s top/bottom edges & enclosure walls Do not place in water or let water leak onto the unit Do not allow debris to fall inside the unit during installation Install at maximum distance from high-voltage cables and power equipment 2 Unitronics

Installation Guide Mounting Dimensions V230 V260/280/290 Unitronics 3

Vision OPLC Models V230/260/280/290 (Non-color Screens) Mounting Before you begin, note that: The mounting panel cannot be more than 5 mm thick To minimize electromagnetic interference, mount the controller on a metal panel and earth the power supply according to the details on page 5 1. Make a panel cut-out that suits your model controller. V230 Cut-out Dimensions V260/280/290 Cut-out Dimensions 4 Unitronics

Installation Guide 2. If you mount the controller on a metal panel, earth the power supply: a. Bore a hole to suit the NC6-32 screw supplied with the kit. b. Scrape panel paint away from the contact area to ensure a conductive connection. c. Drive the screw into the hole. d. Place the following hardware screw s shank, in the order shown in the accompanying figure: washer, ring cable shoe, second washer, spring, and nut. Note: The wire used to earth the power supply must not exceed 10 cm in length. If your conditions do not permit this, do not earth the power supply. 3. Slide the controller into the cut-out, ensuring that the rubber seal is in place. 4. Push the 4 mounting brackets into their slots on the sides of the controller as shown in the figure to the right. 5. Tighten the bracket screws against the panel. Hold the bracket securely against the unit while tightening the screw. 6. When properly mounted, the controller is squarely situated in the panel cut-out as shown in the figure to the right. Wiring: General Do not touch live wires Unused pins should not be connected. Ignoring this directive may damage the device Caution To avoid damaging the wire, do not exceed a maximum torque of 0.5 N m (5 kgf cm) Do not use tin, solder, or any substance on stripped wire that might cause the wire strand to break Use crimp terminals for wiring; use 26-14 AWG wire (0.13 mm 2 2.08 mm 2 ). 1. Strip the wire to a length of 7±0.5mm (0.250 0.300 ). 2. Unscrew the terminal to its widest position before inserting a wire. 3. Insert the wire completely into the terminal to ensure a proper connection. 4. Tighten enough to keep the wire from pulling free. Unitronics 5

Vision OPLC Models V230/260/280/290 (Non-color Screens) Power Supply The controller requires an external 12 or 24VDC power supply. The permissible input voltage range is 10.2-28.8VDC, with less than 10% ripple. A non-isolated power supply can be used if a 0V signal is connected to the chassis You must use an external circuit protection device Install an external circuit breaker. Guard against shortcircuiting in external wiring Double-check all wiring before turning on the power supply Do not connect either the Neutral or Line signal of the 110/220VAC to device s 0V pin In the event of voltage fluctuations or non-conformity to voltage power supply specifications, connect the device to a regulated power supply To avoid electromagnetic interference, earth the power supply as described on page 5 +V 0V Circuit protection device 12 VDC or 24 VDC Communication Ports Turn off power before making communications connections Signals are related to the controller s 0V; this is the same 0V used by the power supply Always use the appropriate port adapters Caution The serial ports are not isolated. If the controller is used with a non-isolated external device, avoid potential voltage that exceeds ± 10V Serial Communications This series comprises 2 RJ-11-type serial ports and a CANbus port. COM1 is RS232 only. COM2 may be set to either RS232 or RS485 via jumper as described on page 7. By default, the port is set to RS232. Use RS232 to download programs from a PC, and to communicate with serial devices and applications, such as SCADA. Use RS485 to create a multi-drop network containing up to 32 devices. Caution COM1 & 2 are not isolated Pinouts To connect a PC to a port that is set to RS485, remove the RS485 connector, and connect the PC to the PLC via the programming cable. Note that this is possible only if flow control signals are not used (which is the standard case). RS232 RS485** Controller Port Pin # Description Pin # Description 1* DTR signal 1 A signal (+) 2 0V reference 2 (RS232 signal) 3 TXD signal 3 (RS232 signal) 4 RXD signal 4 (RS232 signal) Pin #1 5 0V reference 5 (RS232 signal) 6* DSR signal 6 B signal (-) *Standard programming cables do not provide connection points for pins 1 and 6. ** When a port is adapted to RS485, Pin 1 (DTR) is used for signal A, and Pin 6 (DSR) signal is used for signal B. 6 Unitronics

Installation Guide RS232 to RS485: Changing Jumper Settings The port is set to RS232 by factory default. To change the settings, first remove the Snap-in I/O Module, if one is installed. Open the controller and then set the jumpers according to the following table. Before you begin, touch a grounded object to discharge any electrostatic charge Before removing a Snap-in I/O Module or opening the controller, you must turn off the power RS232/RS485 Jumper Settings Jumper 1 2 3 4 RS232* A A A A RS485 B B B B RS485 Termination *Default factory setting. A A B B Removing a Snap-in I/O Module 1. Locate the four buttons on the sides of the module, two on either side. 2. Press the buttons and hold them down to open the locking mechanism. 3. Gently rock the module from side to side, easing the module from the controller. Opening and Closing the Controller 4. Close the controller by snapping the plastic cover back in its place. 1. Locate the slots on the sides of the controller. 2. Open the controller by inserting a flatbladed screwdriver into the slots located on the side of the controller, then carefully prying off the rear panel. 3. Locate the jumpers, and then change the settings as required. Settings are shown on page 7. Unitronics 7

Vision OPLC Models V230/260/280/290 (Non-color Screens) Re-installing a Snap-in I/O Module 1. Line the circular guidelines on the controller up with the guidelines on the Snap-in I/O Module as shown below. 2 Apply even pressure on all 4 corners until you hear a distinct click. The module is now installed. Check that all sides and corners are correctly aligned. CANbus These controllers comprise a CANbus port. Use this to create a decentralized control network using one of the following CAN protocols: CANopen: 127 controllers or external devices Unitronics proprietary UniCAN: 60 controllers, (512 data bytes per scan) The CANbus port is galvanically isolated. -V L PE H - 24V Power Supply + Circuit protection device 121 terminating resistor CANbus Wiring +V Use twisted-pair cable. DeviceNet thick shielded twisted pair cable is recommended. Network terminators: These are supplied with the controller. Place terminators at each end of the CANbus network. Resistance must be set to 1%, 121Ω, 1/4W. -V L PE H Connect ground signal to the earth at only one point, near the power supply. +V The network power supply need not be at the end of the network. CANbus Connector -V L PE H +V 121 terminating resistor The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the forgoing from the market. All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising out of or in connection with the use or performance of this information. The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them DIG-V2XX 06/08 8 Unitronics