EP s approach to Power & Energy efficiency in DCs & paradigms

Similar documents
Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

Making the impossible data center a reality.

Application of Green Technology For Data Centre

Data Centre Energy Efficiency. Duncan Clubb EMEA Data Centre Practice Director CS Technology

Planning a Green Datacenter

How to improve efficiency in Data Processing Centres (DPCs) The importance of knowing the PUE. center DPC

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

The Greening of Services

DC Energy, Efficiency Challenges

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Trends and legislations in the data center industry. Pär Åberg - Business Development Manager - Swegon

MSYS 4480 AC Systems Winter 2015

18 th National Award for Excellence in Energy Management. July 27, 2017

The European Programme for Energy Efficiency in Data Centres: The Code of Conduct

Catch the Heat Avoid the Heat! How an integrated management approach helps to operate your data center energy efficient and reliable

Cloud environment. dr inż. Piotr Boryło , Kraków

Server room guide helps energy managers reduce server consumption

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

CRAH Retrofit and Energy Savings Project

Efficiency of Data Center cooling

Green Computing Starts With Virtualization Anand Shrivastava

Green Computing and Sustainability

Session 6: Data Center Energy Management Strategies

Intermediate Certificate in EU Code of Conduct for Data centres

Data Center Lifecycle and Energy Efficiency

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

MEASURE MONITOR UNDERSTAND

Overcoming the Challenges of Server Virtualisation

Google s Green Data Centers: Network POP Case Study

Data Centre Energy & Cost Efficiency Simulation Software. Zahl Limbuwala

Success Cases in Green Initiatives. Sofrecom Know-how. September 16,2015

1.0 Executive Summary. 2.0 Available Features & Benefits

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

Green Data Centers A Guideline

Green IT and Green DC

International 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work

Green Computing: Datacentres

Switch to Perfection

ETSI GS OEU 008 V1.1.1 ( )

Case Study Leicester City Council

Case study on Green Data Center. Reliance Jio Infocomm Limited

Measurement and Management Technologies (MMT)

IT Air Conditioning Units

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

DCIM Data Center Infrastructure Management Measurement is the first step

Data Center Carbon Emission Effectiveness

Green ICT issues on Mobile Network Systems

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Meeting the Energy Efficiency and Financial Challenges in IT. Liam Newcombe BCS Data Centre Specialist Group Secretary

Green Computing: Datacentres

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Virtualization and consolidation

Data Center Infrastructure Management (D.C.I.M.)

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

How to Increase Data Center Efficiency

Green IT by all parties

Industry leading low energy evaporative fresh air cooling.

LG CNS Global Cloud Data Center

Data Center Energy Savings By the numbers

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

84 kw, Tier 3, Direct Expansion, 937 ft 2

Inside the Data Center: Opportunities for Energy Efficiency

Green IT Project: The Business Case

Power Monitoring in the Data Centre

Thermal management. Thermal management

EU Code of Conduct on Data Centre Energy Efficiency

3all environmental impact and business enabling green benefits that

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Welcome Association of Energy Engineers to the Microsoft Technology Center

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services

Recapture Capacity for Existing. and Airflow Optimization

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime

Green Data Center. Tony Seno Hartono Advanced Technology Director

DCIM Data Center Infrastructure Management

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Environmental Microsoft

HPC Solutions in High Density Data Centers

Innovative Data Center Efficiency Techniques. Michael K Patterson, PhD PE Eco-technology Program Office Intel Corporation

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

EDX DC-3 environmental monitoring solution

Data Centers. The Environment. December The State of Global Environmental Sustainability in Data Center Design

Data Center Power Savings

Hbusiness enabling green benefits that the A G SI offers to its

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

November/December 2011

SIX Trends in our World

Data Centre Solutions. Data Centre Solutions Expertly Engineered

Data Center Infrastructure Management ( DCiM )

How High-Density Colocation and Enhanced Visibility Improve Business Performance

The Green Imperative Power and cooling in the data center

EUROPEAN DATA CENTRE STANDARDS

Transcription:

DG for Innovation and Technological Support EP s approach to Power & Energy efficiency in DCs & paradigms Presentation Presentation subtitle subtitle or lead-in or lead-in that says that what says what this is this about. is about. Or a catchy Or a catchy quote quote that will that grab will grab people s people s attention. attention. Optional follow-up punchline

Agenda Power vs Energy- Efficiency/ Metrics/ CO2 Who we are: DC management in EP Measures for power and energy efficiency Case studies Our efficiency plan

Power vs Energy- Efficiency/ Metrics/ CO2 Power: rate of doing work, in Watt (W) Energy: total amount of work done, in Watt-hour (Wh) Which consumes more? 1 kw server, 1kWh server or 10 kwh server? 1kWh in 1 h is 1kW, 1 kwh in 0.5 h is 2 kw and 1 kwh in 10 h is 0.1 kw. Efficiency: usefully used / the total input Metrics: - DCiE = IT Equipment Power/Total Facility Power x 100% - PUE = Total Data Center Source Energy/ IT Source Energy - GEC = Green energy used by the DC/ Total DC Source Energy CO2 creation: Carbon is released by burned fossils (oil, gas, coal) and joins the atoms of Oxygen in the atmosphere 1 metric ton of C produces 3.67 metric tons of CO2 5.23 metric tons the emission from an average personal car in 1 year= (the average volume of a hot air balloon- 2,832 cubic metres) 534.8 m3 is the volume of one ton of CO2 in 15 C.

Who we are: DC management in EP European Parliament Secretary General Directorate-General for Innovation & Technological Support Directorate for Infrastructure & Equipment Operations Hosting Unit Head of the Operations & Hosting Unit: Rafael RUIZ DE LA TORRE A team of 30 officials and 100 external consultants: Network, Servers: Unix & Windows, Storage: SAN, NAS, Backup, Virtualisation, Testing, Tools Offers the EP: - ICT infrastructure and - information systems running on it Always!

Who we are: DC management in EP European Parliament Secretary General Directorate-General for Innovation & Technological Support Directorate for Infrastructure & Equipment Operations Hosting Unit Coordinator of Facilities Management: Dimitrios PASPALTZIS Duties: Ensuring high disponibility (cooling, power & connectivity) Preparing infrastructure for new incoming material Installation & removal of material (rack, cabling,...) Management of interventions in the data centres DC asset management Security access management Capacity reporting (consumption, space, ) What ismissing? Capacity & Continuity Service Facilities Management

Measures for power and energy efficiency The OPERATIONS unit is implementing policies and measures that reduce the global environmental impact of the European Parliament ICT infrastructure: Follow best practices- quick wins Consolidation of infrastructure in professional data Centres Acceleration of decommissioning procedures Virtualisation of servers Renewal of IT servers with more energy-efficient ones Use of renewable energy Regular contributions to EP EMAS programme Raising awareness

Follow best practices- quick wins Cooling: - Air Flow Management and Design: Design Hot / Cold aisle Rack air flow management Blanking Plates Raised floor air flow management - Cooling Management: Review of cooling before IT equipment changes Other Data Centre Equipment: - Office and Storage Spaces: Turn off Lights Monitoring: - Energy Use and Environmental Measurement: Incoming energy consumption meter, IT Energy consumption meter, Room level metering of air temperature and humidity, CRAC / CRAH unit level metering of supply or return air temperature - Energy Use and Environmental Reporting: Written report

Measures for power and energy efficiency (more analytically) Data centre consolidation (& server renewal) => Cumulated reduction by 26.887 MWh and by 8.676 Tons of CO2. In 10 years we had consolidated from 22 computer rooms into 3 main DCs, hosting 96% of the total infrastructure. PUEs between 2,5 and 3,5 to PUEs between 1,6 and 2.

Measures for power and energy efficiency Data centre consolidation Estimations (kw) 9

Measures for power and energy efficiency Acceleration of decommissioning (2 months faster) => Reduction of 504MWh and 163 Tons of CO2. >1,000 IT equipment removed from the DCs with an average of 350 Watts of power consumption each. - energy savings by removing fast the old high power equipment - Corporate Social Responsibility by donating to OXFAM functional equipment We raise awareness also to people outside our Unit by actions like publishing articles (e.g. the article Did you know emails also have a carbon footprint? ) or analyses concerning mostly energy efficiency and power consumption of components of the IT infrastructure such as the WIFI Infrastructure, incidents of massive email exchange and email footprint.

Measures for power and energy efficiency Follow the latest tendencies and recommendations to the design and operation of our DCs. Most effective are the following: Virtualization: From physical to virtual servers to approximately 100%. Reduction of the power consumption >20% Replacement of old high power demanding IT equipment with new more power efficient, increasing the ratio of CPU speed per kw. E.g., at the transition from the old email infrastructure to the new one OPERATIONS achieved 65% reduction of the carbon footprint for the email traffic and 75% reduction for the email backup and storage with the previous email migration. The continuous renewal of infrastructure has resulted in a general reduction of the total power consumption of 10%, enhancing at the same time the infrastructure by adding 20% more servers (to fulfil growing demands) and multiplying the overall computing power by 2,5 times Use of renewable energy: in both main DCs, 100% of the electrical energy used comes from renewable energy sources

Measures for power and energy efficiency Involvement in EMAS yearly action plans. EMAS: Eco-Management and Audit Scheme: tool to help organisations reduce their impact on the environment. The Parliament is committed to reducing its carbon footprint by 30% by 2020.

Measures for power and energy efficiency Involvement in EMAS yearly action plans. More specifically: - Conducting energy audits and examining compliance of our main data centres with the European Conduct of Conduct. One DC is already compliant (participant) and the other one will be by March 2018. - Studies on servers and other ICT infrastructure: Detailed study on emailing and servers CO2 production and determination of best actions to reduce it Extend the exercise done for emailing and CO2 to other ICT infrastructures (storage, applications in production, network etc.)

Facilities Exchange assets inventory extraction Create categories (servers, backup, storage,others) Power consumption estimation Network power consumption average Datacenter PUE => Total Facilities power consumption for - Exchange 2003 - Exchange transition period - Exchange 2010 case studies Traffic statistics Power consumption by MB sent Volume sent by KiloWatt Volume sent by Watt => Footprint (g CO²e) for one mail Email Global Statistics Number of Messages for 2012 Total volume traffic for 2012 Number of mailboxes Average size of mailboxes => Email size average => Total storage size => Email sent average EMAS Storage/Backup statistics Power Consumption by Mailbox by year Power Consumption by GB => Annual Footprint for one mailbox Footprint calculation for a usual user Footprint calculation for a greedy user Comparison with a efficient car CO²e/kWh coefficient for Belgium and Luxembourg All Teams PCF (usage excluded) for: kg CO²e per asset (EMAS) kg CO²e per HDD (EMAS) Numbers of Assets/HDD (Facilities/Mail) Methodology for the email studies

case studies Did you know emails also have a carbon footprint? - The annual footprint of the average user (35,96 kg/ CO ² e per year) corresponds to driving a typical car for 225 km per year (a typical car produces 160g of CO ² /km), - The average user has approximately 2 GB of information in his primary mailbox and other 2 GB in his archive. It takes 37 kg of CO2/year to store 1 GB. - Concerning the email traffic, the footprint of sending an email of 1 MB is 1,84 g CO ² e. The footprint to store this email in your mailbox for one year is 6,2g CO ² e. - New email infrastructure affected the carbon footprint of email traffic: average size of a message has increased, the footprint to send it has decreased by 64%. The traffic volume per kwh has increased more than 3 times. - Although average size of a mailbox has increased 6 times, the footprint for storage and traffic practically remained the same. Storage efficiency: for 1 GB of storage we now consume 6 times less energy

case studies X incident" email storm; repercussions & Luxembourg to Cape Town! - Spamming has a drastic effect on the environment by increasing email storage costs (not the traffic). - The retention policy - too many users kept this e-mail in their inbox without deleting it, occupying 0,1% of the total storage used for e-mail. - Before the new policy, these e-mails would have remained in the inbox and would have been archived, forever - The storage resources used were 16 times the resources used by the average user for 1 year! - Thanks to the retention policy these e-mails were kept only for 3 months, reducing the CO2 emissions produced from these incidents by 75% in the first year and 100% for the following years - Environmental impact of this incident: driving an average car for 2,700 km which is like driving from Luxembourg to Athens - Prior to the implementation of the new policy, this could have been as much as 14,000 km, like driving from Luxembourg to Cape Town

So please, don t send emails to more recipients than necessary and delete them regularly! Don t forget to: - Check regularly your mailbox size - Delete your obsolete emails regularly - Delete heavy attachments quickly case studies - Send links instead of heavy attachments

Our energy efficiency plan Based on the latest tendencies and recommendations regarding the design and operation of DCs we have compiled our energy efficiency plan for the next years: Cloud computing: analysis of cloud computing possibilities Proposing and implementing best practices at our new DC such as use of cold containments, airflow optimization. The heat from the room will be used to warm the building. We are reviewing our cooling policy. We have already increased the maximum temperature in one DC from 18 C to 21 C. The other DC will follow. We will test the infrastructure gradually by increasing slowly each time by 0,5 C until we reach 27 C. Every degree of increase in the Recommended Temperature Set Point can result in additional 4% to 7% energy savings in the Data Center Use of modern tools for the management and simulation of the DC. Proposal for new DCIM tool and a CFD analysis tool for the optimization of the airflow and cooling: holistic view of the data centre, ranging from the rack to the cooling infrastructure and energy utilization.

Questions?

Thank you