Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR

Similar documents
Target Motion Tracking in MRI-guided Transrectal Robotic Prostate Biopsy

arxiv: v1 [cs.cv] 6 Jun 2017

MRI-Guided Prostate Motion Tracking using Multislice-to-Volume Registration

Lecture 6: Medical imaging and image-guided interventions

Multi-slice-to-volume registration for MRI-guided transperineal prostate biopsy

A Combined Statistical and Biomechanical Model for Estimation of Intra-operative Prostate Deformation

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department

Real-time self-calibration of a tracked augmented reality display

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

A high accuracy multi-image registration method for tracking MRIguided

A Non-Linear Image Registration Scheme for Real-Time Liver Ultrasound Tracking using Normalized Gradient Fields

Atlas Based Segmentation of the prostate in MR images

Prostate Brachytherapy Seed Segmentation Using Spoke Transform

Deformable Registration Using Scale Space Keypoints

Fast CT-CT Fluoroscopy Registration with Respiratory Motion Compensation for Image-Guided Lung Intervention

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION

Software Strategy for Robotic Transperineal Prostate Therapy in Closed-Bore MRI

Projection-Based Needle Segmentation in 3D Ultrasound Images

ABSTRACT 1. INTRODUCTION

NIH Public Access Author Manuscript Proc SPIE. Author manuscript; available in PMC 2010 December 1.

Elastic Registration of Prostate MR Images Based on State Estimation of Dynamical Systems

RADIOMICS: potential role in the clinics and challenges

Robot-assisted MRI-guided prostate biopsy using 3D Slicer

A New Method for CT to Fluoroscope Registration Based on Unscented Kalman Filter

Prostate Brachytherapy Seed Reconstruction Using C-Arm Rotation Measurement and Motion Compensation

2D-3D Registration using Gradient-based MI for Image Guided Surgery Systems

Improvement and Evaluation of a Time-of-Flight-based Patient Positioning System

Biomechanically Constrained Ultrasound to Computed Tomography Registration of the Lumbar Spine

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

Step-wise identification of ultrasound-visible anatomical landmarks for 3D visualization of scoliotic spine

Assessing Accuracy Factors in Deformable 2D/3D Medical Image Registration Using a Statistical Pelvis Model

Methodological progress in image registration for ventilation estimation, segmentation propagation and multi-modal fusion

Navigation System for ACL Reconstruction Using Registration between Multi-Viewpoint X-ray Images and CT Images

A fast breast nonlinear elastography reconstruction technique using the Veronda-Westman model

X-ray Target Reconstruction for Cyber Knife Radiosurgery Assignment for CISC/CMPE 330

Medicale Image Analysis

MR-Guided Mixed Reality for Breast Conserving Surgical Planning

Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases

Inter-slice Reconstruction of MRI Image Using One Dimensional Signal Interpolation

Development and validation of a short-lag spatial coherence theory for photoacoustic imaging

Copyright 2009 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 7260, Medical Imaging 2009:

By choosing to view this document, you agree to all provisions of the copyright laws protecting it.

Automatic Subthalamic Nucleus Targeting for Deep Brain Stimulation. A Validation Study

NIH Public Access Author Manuscript Proc SPIE. Author manuscript; available in PMC 2013 December 31.

University College London, Gower Street, London, UK, WC1E 6BT {g.gao, s.tarte, p.chinchapatnam, d.hill,

Semi-automatic Segmentation of Vertebral Bodies in Volumetric MR Images Using a Statistical Shape+Pose Model

NIH Public Access Author Manuscript Proc Soc Photo Opt Instrum Eng. Author manuscript; available in PMC 2014 July 28.

4D Shape Registration for Dynamic Electrophysiological Cardiac Mapping

Closed-Loop Control in Fused MR-TRUS Image-Guided Prostate Biopsy

Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines

Slice-to-Volume Registration and its Potential Application to Interventional MRI-Guided Radio-Frequency Thermal Ablation of Prostate Cancer

Image Acquisition Systems

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

3D-printed surface mould applicator for high-dose-rate brachytherapy

Modeling and preoperative planning for kidney surgery

Image Guidance and Beam Level Imaging in Digital Linacs

Interactive Deformable Registration Visualization and Analysis of 4D Computed Tomography

Spatio-Temporal Registration of Biomedical Images by Computational Methods

Calibration Method for Determining the Physical Location of the Ultrasound Image Plane

Guide wire tracking in interventional radiology

S. Guru Prasad, Ph.D., DABR

Automatic 3D Segmentation of Ultrasound Images Using Atlas Registration and Statistical Texture Prior

Whole Body MRI Intensity Standardization

Non-rigid Registration of Preprocedural MRI and Intra-procedural CT for CT-guided Cryoablation Therapy of Liver Cancer

Reproducibility of interactive registration of 3D CT and MR pediatric treatment planning head images

Automated Quality Assurance for Image-Guided Radiation Therapy

A Study of Medical Image Analysis System

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis

Prostate Detection Using Principal Component Analysis

COMPREHENSIVE QUALITY CONTROL OF NMR TOMOGRAPHY USING 3D PRINTED PHANTOM

SlicerRT Image-guided radiation therapy research toolkit for 3D Slicer

Validation System of MR Image Overlay and Other Needle Insertion Techniques

SIGMI Meeting ~Image Fusion~ Computer Graphics and Visualization Lab Image System Lab

Multi-modal Image Registration Using the Generalized Survival Exponential Entropy

Sensor-aided Milling with a Surgical Robot System

Nonrigid Registration using Free-Form Deformations

Comparison Study of Clinical 3D MRI Brain Segmentation Evaluation

doi: /

Automated segmentation methods for liver analysis in oncology applications

Real-time transverse process detection in ultrasound

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

Biomedical Image Analysis based on Computational Registration Methods. João Manuel R. S. Tavares

IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 29, NO. 10, OCTOBER

Fully Automatic Model Creation for Object Localization utilizing the Generalized Hough Transform

Department of ECE, SCSVMV University, Kanchipuram

Mech. Engineering, Comp. Science, and Rad. Oncology Departments. Schools of Engineering and Medicine, Bio-X Program, Stanford University

Nonrigid Motion Compensation of Free Breathing Acquired Myocardial Perfusion Data

3-D Compounding of B-Scan Ultrasound Images

The team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge.

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

CUDA Accelerated 3D Nonrigid Diffeomorphic Registration

Learning-based Neuroimage Registration

ANALYSIS OF PULMONARY FIBROSIS IN MRI, USING AN ELASTIC REGISTRATION TECHNIQUE IN A MODEL OF FIBROSIS: Scleroderma

DEFORMATION MODELING OF BREAST BASED ON MRI AND FEM.

Dynamic management of segmented structures in 3D Slicer

Additional file 1: Online Supplementary Material 1

Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay

Image-Guided Interventions Technology and Applications. Organizers: Emad Boctor, Pascal Fallavollita, Ali Kamen, Ziv Yaniv

Interactive Differential Segmentation of the Prostate using Graph-Cuts with a Feature Detector-based Boundary Term

Transcription:

Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR Sean Gill a, Purang Abolmaesumi a,b, Siddharth Vikal a, Parvin Mousavi a and Gabor Fichtinger a,b,* (a) School of Computing, Queen s University, Kingston, Ontario, Canada Email: {gill, purang, vikals, pmousavi, gabor}@cs.queensu.ca (b) Department of Electrical Engineering, Queen s University, Kingston, Ontario, Canada Abstract: A slice-to-volume registration algorithm, to be used for prostate tracking, is presented. The technique is designed to provide patient tracking information for prostate biopsy performed under MR guidance. Interventional MR slices are acquired from a static physical plane just prior to needle insertion. These slices are registered to a high resolution volume of the patient. Registration is performed at two resolutions, with the result of the low resolution registration used as the initial alignment of the high resolution step. Two versions of the algorithm are implemented: registration with a transverse slice and registration with intersecting transverse and sagittal slices. Validation is performed on five high resolution patient data sets. After segmentation of the prostate, an interventional MR slice is simulated and subsequently translated and rotated from its original position. Registration performed to recover the original position resulted in average target registration errors below 1 mm, for both the single transverse slice and the combination of a transverse and a sagittal slice. Keywords: Intra-operative registration, Prostate, MR 1. Purpose Magnetic Resonance Imaging (MR) has shown great promise in targeted therapy, such as brachytherapy, and biopsy of early stage prostate cancer (D Amico et al. 2001). Intraoperative registration of the planned and actual positions of the target is of paramount importance in these interventions. As the intervention proceeds, the prostate tends to shift position, change orientation and even deform, making the initial registration invalid. This can lead to, inaccurate biopsy, poor localization of therapeutic radiation and excessive exposure of healthy tissue to ionizing radiation. The goal of this work is to track the prostate and update the registration between the preoperative plan and the patient throughout the procedure. We propose a slice-to-volume registration technique to be used in a framework where the intervention is performed within an MR machine and intermittent interventional MR slices are used to track the prostate. As this algorithm is to be used in a clinical setting, the speed of the registration is of great importance. Fei et al. performed registration at three resolution levels and applied several random restarts to ensure a valid registration (Fei et al. 2003). Chandler et al., whose application had little concern for temporal performance, ran an all-out mutual information registration (Chandler

et al. 2006). In our case, constraints on prostate motion allows for streamlining these approaches to improve upon computational cost, while retaining an accurate registration. 2. Materials and Methods We propose to track the prostate through intermittently acquired, spatially fixed interventional MR slices. The current implementation assumes that a high resolution volume image of the prostate is acquired immediately before the procedure. Our registration algorithm builds upon those proposed earlier (Fei et al. 2003, Chandler et al. 2006, Xu et al. 2005). Interventional MR slices tend to have lower resolution and larger slice thickness than those in preoperative MR volumes. We simulate an interventional slice by averaging the pixel values, within the preoperative volume, across a predefined interventional MR slice thickness. In our experiments we used a slice thickness of 5 mm. In essence, tracking maximizes the similarity between the real interventional MR slices and the simulated interventional MR created at its corresponding location within the high resolution preoperative volume. Fig. 1. Interventional MR slices are intermittently acquired from the same physical plane (top). As the target shifts, the resulting MR slice (bottom) is used to update the registration of the preoperative plan. Our algorithm maintains the multi-resolution approach from previously methods (Fei et al. 2003) but entirely removes the random restarts and only uses two consecutive levels of resolution: one quarter resolution and full resolution. This was done to improve the running time of the registration should not have an adverse effect on the, due to the constraints on prostate motion. Initially this algorithm was designed to register a single interventional MR slice; however a single slice may not be contain enough information to accurately register to the volume. As such, the algorithm was extended to register two slices in unison. The real interventional MR slice is acquired and initially aligned with the preoperative volume. An interventional MR slice is then simulated from the initial location of the real slice. This simulated slice is updated at each step of the registration, according to the new alignment of the real slice. The first stage of the registration is performed at one quarter of the full resolution (Fig. 2, left) where correlation coefficient is used as similarity metric. The resulting transformation is then used as initial alignment for

registration at full resolution (Fig. 2, right) applying mutual information as similarity metric. The Nelder-Mead Simplex algorithm is used as the optimization algorithm at both stages of the slice-to-volume registration (Nelder and Mead, 1965). Fig. 2. Segmented prostate from a simulated interventional MR slice at one quarter resolution (left) and at full resolution (right). 3. Experiments and Results Five clinical MR prostate volumes are used in the validation of our slice-to-volume registration. Datasets for all patients were acquired as a set of transverse slices, have pixel spacing within the range of 1.5-1.75mm and have a slice thickness of 3 mm. Due to the thickness of the slices, any extracted sagittal slices are of comparatively low resolution. For this reason we included a test where the algorithm was modified to keep the sagittal slices at full resolution throughout the registration process. In an actual clinical setup, as the prostate moves, the MR slice is still acquired from the same physical plane. In our validation experiments, the motion was reversed, in that we fixed the volume and computationally moved a simulated interventional image plane around, thereby creating an accurate ground truth. Due to observed constraints on the prostate s motion, we assume a maximum 10 mm of displacement and 10º of rotation about each axis. We assume negligible deformation of the prostate gland which is generally true until needle insertion begins, an assumption also used by Xu et al. (Xu et al. 2005). A tight region of interest around the prostate was selected, because otherwise the registration would be unduly influenced by deformations in the surrounding soft tissue. In our case, this was accomplished by a manually selected bounding box around the prostate. We performed two sets of tests: the first measuring the accuracy of our slice to volume registration using a transverse interventional MR slice and the second measuring the accuracy of the registration when using a transverse slice and an intersecting sagittal slice. For the first test, we simulated a transverse interventional MR image with cutting out a slice from the volume and degrading its fidelity by adding Gaussian noise. Slice-tovolume registration was performed five times for each patient dataset, with an initial alignment randomly chosen from a uniform distribution of 10 mm displacement along each axis and 10º of rotation about each axis. Accuracy was measured by the target registration error (TRE), calculated as the mean Euclidian distance of the slice pixels from the correct alignment in the volume. In the second test, we used two intersecting transverse and sagittal interventional MR planes. The third test also used two intersecting transverse and sagittal slices, but kept the sagittal slice at full resolution throughout the registration. This was done to compensate for the low axial resolution of our datasets.

Results are summarized in Table 1. Registration with a solo transverse slice resulted in a TRE of 2.97 mm and standard deviation of 3.22 mm. Registration with transverse and sagittal slices resulted in a TRE of 1.14 mm and a standard deviation of 1.41 mm. Registration with transverse and sagittal slices, while keeping the sagittal slice at full resolution, resulted in a TRE of 0.75 mm and a standard deviation of 0.79 mm. Clearly, an additional sagittal slice provides a significant benefit to the registration. Similarly, keeping the sagittal slice at full resolution greatly improved the registration accuracy. We believe that this was primarily due to the low axial resolution of the datasets. Had the MR volume been acquired with a smaller slice thickness, the results for the registration with low resolution sagittal slices would have produced comparable results. The algorithms were implemented in Matlab; average running time of registration was 36 s, 79 s and 107 s, for the three versions of the algorithm, respectively. Tab. 1. Target registration error of the slice-to-volume registration. Ten sets of slice-to-volume registrations were performed for each patient. Initial misalignment was chosen randomly from the uniform distribution of ±10mm displacement and ±10º of rotation about each axis. Target Registration Error (mm) / Standard Deviation Patients Transverse Slice Transverse and Sagittal Slice Transverse and Sagittal Slice (Full Resolution) P1 3.22 / 3.44 1.04 / 0.96 0.80 / 0.77 P2 5.06 / 5.08 2.07 / 2.56 0.90 / 1.26 P3 1.72 / 1.57 1.00 / 0.90 0.56 / 0.47 P4 1.62 / 1.62 0.92 / 0.89 0.87 / 0.68 P5 3.24 / 2.25 0.67 / 0.70 0.63 / 0.67 Average 2.97 / 3.22 1.14 / 1.41 0.75 / 0.79 4. Conclusions The relevant size of prostate cancer foci is approximately 4 mm, the diameter of the slimmest needle used in prostate interventions is about 2 mm and the diameter of implanted brachytherapy seeds is close to 1 mm. In this light, the accuracy and robustness of this prostate tracking method is promising, though it must be validated in more patients and under deformations. The current implementation was not designed for real-time tracking; it will be used to validate organ position before needle insertion. As such, the current speed of the registration is acceptable; however, we do expect a significant reduction in running time when the algorithm is implemented in a lower level language. This will become more important in our future work where we plan to extend the registration to account for deformations in the prostate after needle insertion. 5. Acknowledgments This work has been supported by the Natural Sciences and Engineering Research Council (NSERC), the Canadian Institutes of Health Research (CIHR) and the U.S National Institutes of Health, grants 5R01CA111288-02 and 5R01EB002963-04.

6. References Chandler, A.G., R.J. Pinder, T. Netsch, J.A. Schnabel, D.J. Hawkes, D.L.G. Hill and R. Razavi. 2006. Correction of Misaligned Slices in Multi-Slice MR Cardiac Examinations by Using Slice-to-Volume Registration, 3 rd International Symposium on Biomedical Imaging: Nano to Macro, pp. 474-477. D Amico, A.V., R.A. Cormack and C.M. Tempany. 2001. MR-guided Diagnosis and Treatment of Prostate Cancer, New England Journal of Medicine, Vol. 344, pp. 776-777. Fei, B., J. Duerk, T. Bol, J. Lewin, and D. Wilson. 2003. Slice-to-Volume Registration and its Potential Application to Interventional MR-Guided Radio-Frequency Thermal Ablation of Prostate Cancer, IEEE Transactions on Medical Imaging, Vol. 22, pp. 515-525. Nelder, J.A. and R. Mead. 1965. A Simplex Method for Function Minimization, The Computer Journal, Vol. 7, pp. 308-313. Xu, S., G. Fichtinger, R.H. Taylor and K. Cleary. 2005. Validation of 3D Motion Tracking of Pulmonary Lesions Using CT Fluoroscopy Images for Robotically Assisted Lung Biopsy, Proceedings of SPIE, pp. 60-68.