SCADALink IP100 SCADA Terminal Server QUICK START GUIDE Revision 1.42 June 19, 2012

Similar documents
EQ-DCM User Manual Revision 1.02 Sep 10, 2013

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Ethernet HMi RAC and Gateway Setup Instructions Rev. 09

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

P2 Configuration Guide

DATRAN XL4 RTU Modbus Interface

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

Quick Start. Appearance and pin assignments

ZLAN5443A. User Manual

EKI-6332 & EKI-136x- MB_setup example SOP. Revision Date Revision Description Author April/2018 V1.0 Initial release ICG AE Jacky.

EQ7000. User Manual. Rev 1.00

Canlan INSTALLATION MANUAL

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

Ethernet Interface Module

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

MB40 & MB45 MODBUS TCP/IP Gateway Handbook

MODBUS TCP/IP TO MODBUS SERIAL GATEWAY. MODEL No: MGate-1024-DC VER 2.0

Product Family: Networking Hardware Number: AN-NH-012

GEM80 & ewon Setup Quick Guide

NordField Electronics

Installation and User Guide

Ethernet to RS-232/485 Gateway

EEG ComCC 1250m Modem Data Multiplexer

GW1000 User s Guide. Revision 1.04 Mar 30, 2008

# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

EtherSeries Modbus Gateway EMB-2 User s Guide

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

TRP-C37 User s Manual

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

TRP-C37M User s Manual

International Headquarters. European Headquarters

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

Installation and Programming Manual

IntesisBox Modbus Server - Honeywell XLS 80

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Ethernet to Serial Port Module RS-232/422/485 to Internet Gateway

MESP211 Series USER MANUAL

User Manual A08. User Manual

USER MANUAL FOR GS100/GS1003G

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for TPSD/A36D Chargers with S2A-205T Option 21P or 57T or 57U. Setup Instructions

DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for A31 Inverters with S2A-383S Option 21P. Setup Instructions

TRP-C37M User s Manual

DeviceMaster UP Modbus Controller to Controller Communication

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

User Manual Revision: A04 June 23, QuEST Rail LLC.

Kramer Electronics, Ltd. ETHERNET Configuration (FC-11) GUIDE

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

EGW1-IA3-MB User s Manual

FieldServer X-25 Start-Up Guide

APPENDIX RC4500 GUI Graphical User Interface for RC4500 Antenna Control Unit

ATK3 I/O Module (Modbus Slave)

WM-120. Serial to Ethernet Module. Serial to Ethernet Module. User Manual. Version 1.0. Infosystem Technology Corporation, Ltd.

Model XS1000 TCP/IP to RS232/422/485 Device Server User s Manual

IntesisBox Modbus Server Fidelio IP

International Headquarters. European Headquarters

TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

ETOR-4. Ethernet/Serial Gateway USER MANUAL

Installation and Configuration Guide

Industrial Serial Device Server

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

ETOR-4 Ethernet/Serial Gateway ETOR-4. Ethernet/Serial Gateway USER MANUAL

CONFIGURATION SOFTWARE

SB72EX User's Manual

REL 512 Connectivity With A Harris Westronics RTU Using DNP 3.0

EEG CC1260 icap Interface Card

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

A12B DNP 3.0 SERIAL & ETHERNET (TCP/IP) SCADA INTERFACE

e-net TCP/IP Converters

Overview. Table of contents

Video Decoder Setup Guide

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Site Preparation. for AE250 Inverter Installation Guide. SolarVu

RTU560 Remote Terminal Unit Connections and Settings

24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide

MGate MB3000 Modbus Gateway User Manual

Doc October ProtoNode Reference Manual

tsh-700 Series User Manual

Any device, including routers and hosts, is running an implementation of IP address Host

MGate MB3000 Modbus Gateway User s Manual

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

The Applications and Gaming Tab - Port Range Forward

Plus-X Dual IP-8 Adapter. Installation and Operation Manual

SERIAL TO ETHERNET CONVERTER E-P User Manual

WiFi to RS-422/485 adapter user manual

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

1. Supplied Items. 2. Connecting the DTS SKT. Input side. Input Side

INSTALLATION GUIDE Maxiflex P3e CPU M1262F

User Guide. ewon500 The Configurable Gateway PURPOSE. You have just received your brand new ewon500!

HIGH-SPEED DOWNLOAD PROCEDURE. EDGE / IoE2 Modules

Monitoring & Configuring ENTES serial devices by EMG-10. EMG-10 is a Modbus Server which is used for monitoring ENTES serial devices

MM300 Motor Management System

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Technical/Operations Manual V 1.1.1

Transcription:

SCADA Terminal Server QUICK START GUIDE Revision 1.42 June 19, 2012 www.scadalink.com

INTRODUCTION Use this Quick Start Guide to configure a SCADALink IP100. Full documentation is found under the IP100 GUI Software Help section. The IP100 GUI Software has the most up-to-date information including details such as Connection modes, configuration parameters, adding I/O modules, firmware downloading, physical cables and troubleshooting. Application Notes and other additional information can be found online at www.scadalink.com. June 19, 2012 INTRODUCTION 2 of 12

1. HARDWARE CONNECTION Apply 10-30VDC Power to PWR and GND terminals. Digital Input, Digital Output Relay Output (Form C) Power Power Output COM1 RS-232 1 9 8 16 Hardware Reset Button Internal I/O Bus Reserved LED s COM0 RS-232 Ethernet Port COM2 RS-232 17 25 24 32 COM3 RS-232 COM2 RS-485 Figure 1: IP100 Hardware COM4 RS-232 June 19, 2012 1. HARDWARE CONNECTION 3 of 12

2. SOFTWARE INSTALLATION Install IP100 GUI software. This software is found on the IP100 CD or online at www.scadalink.com. NOTE: When installing software from the website, save the installer file to your local drive first before running the installer. 3. CONNECTING TO THE IP100 For configuration or firmware loading, connect a cable between your PC and the IP100 COM0, COM1, or Ethernet port. COM0 Table 1: COM0 Cables Cable Description RJ11-DB9 User RS-232 3 wire serial connection Cable used for general configuration and diagnostics RJ11-DB9 Special cable for firmware Programming programming only (NOTE: only Cable required for firmware version V2.3.4 or earlier) RJ11-DB9 Custom cable from Bentek Switchable Systems with integrated switch Cable allowing both User and Firmware programming capabilities NOTE: Full cable pinouts are found in the GUI Help section June 19, 2012 3. CONNECTING TO THE IP100 4 of 12

COM1 General configuration and diagnostics can be done through the COM1 terminal block using an RS232 3-wire (Tx,Rx,GND) connection. The GUI can connect to COM1 in two ways: 1. At start-up The user has up to 15 second after a hardware reset to connect to COM1 via the GUI software. This state is indicated by all IP100 LED's turned on. NOTE: Run-time diagnostics are not available in Start-Up mode. 2. During run-time At any time while the IP100 is operating, the user can connect to COM1 NOTE: If COM1 has been previously configured as a data port, GUI can only access COM1 during Start-up condition. Ethernet Connection to the IP100 GUI can be made either remotely or locally via Ethernet. Both configuration and diagnostics functions can be used over IP. If Ethernet communications are to be used, the IP address, subnet mask and gateway must be reprogrammed to correspond to the connected subnet in the field. NOTE: A new factory IP100 ships with the following IP parameters: IP address: 192.168.0.110 Subnet mask: 255.255.255.0 Gateway: 192.168.0.1 June 19, 2012 3. CONNECTING TO THE IP100 5 of 12

Once hardware connection is established via one of the above methods, click on Device > Connect from the top menu bar in the GUI software. Choose either serial or Ethernet depending on the hardware connection type you are using. If connecting serially, choose the appropriate COM port used on your computer. If connecting over Ethernet, enter the IP address of the IP100 and the programmed password if applicable. Troubleshooting The most common connection problems arise due to mismatch between the GUI Software version (found in Help > About) and the IP100's installed firmware revision (found in Device > Info). Ensure: If firmware version is V2.3.4 or earlier, the GUI software revision must match the firmware version. All GUI software versions greater than V3.0.9 are cross compatible with all firmware versions greater than V3.0.9 Proper cable, port and menu items have been chosen for configuration or firmware upload The IP100 also has a diagnostic monitoring mode which provides users with a protocol analyzer for any serial port. Please refer to online Help manual for more information. June 19, 2012 3. CONNECTING TO THE IP100 6 of 12

4. CONFIGURE DEVICE After the appropriate cable and power is connected, run the GUI software and choose configuration parameters for the IP100. The available configuration parameters are displayed in the Configuration Tree menu on the left hand side of the GUI. The current configuration loaded in the IP100 can be retrieved by clicking Device > Config > Read from the top menu bar. When finished setting up the desired configuration be sure to write the new configuration to the device by clicking Device > Config > Write. The first three sections are hardware configuration parameters. General Network It is recommended to disable any unused features in the Power Options box. The Site Info box can be used to display the site location name or other useful information that can uniquely identify the unit. IP Address, Subnet Mask and Gateway should be set within the range of the connected subnet. TCP/IP Timout should be set to 3 minutes by default Serial Timeouts must be set to be greater than the typical response time of the connected serial device June 19, 2012 4. CONFIGURE DEVICE 7 of 12

Integrated monitor can be used to determine response time RTS handshaking and RS-485 options can be configured in the Advanced Tab For Firmware upgrade instructions, please consult the online Help menu. The Table below shows the IP100's various Connection modes. Connection Types IP Mux Serial Mux Table 2: Connection Table Description Used for most general terminal server functions where one or more IP hosts need access to poll through an available serial connection using Modbus/ROC/AB DF1 or similar protocols. NOTE: the IP100 will arbitrate multiple masters polling independently over the same IP mux connection (total allowed number of host socket connections per IP port set by the count parameter; max=8) Used to arbitrate multiple serial masters allowing them to share a single serial port when polling Modbus/ROC/AB DF1 or similar protocols. Serial mux destination port can also be shared with a IP mux port allowing combined arbitration of serial and IP polling. June 19, 2012 4. CONFIGURE DEVICE 8 of 12

Virtual Serial Server/Client Serial Master Modbus Broadcast Connect Mode Used to provide a bi-directional dedicated connection between a single IP host and an available serial port. Virtual serial connections are full duplex and protocol independent. Used to route incoming serial polls on an available COM port to various IP destinations based on the requested RTU address. Serial Master connections can only be used with Modbus RTU protocol. Allows incoming serial or IP polls to be sent out multiple output serial ports simultaneously. This mode works in conjunction with Virtual Serial Server or Client and is used to create a link between 2 serial ports (a source and a destination) that is overidden by an IP connection when socket is established. The GUI Help menu has detailed instructions and diagrams for each connection mode. June 19, 2012 4. CONFIGURE DEVICE 9 of 12

5. EXAMPLE CONFIGURATION The following figure shows an example of a common configuration for the IP100. Figure 2 below shows how the IP100 can be configured as a terminal server to enable multiple IP masters to connect to serial devices on COM2 of the IP100. Figure 2: Multiple Modbus Masters Step 1: Power-up IP100 and connect to computer via one of the following methods: User cable to COM0 3-wire cable to COM1 Step 2: Open IP100 GUI software and connect to device Device > Connect > Serial Step 3: Upload Current Configuration from device Device > Config > Read Step 4: Configure Network Settings. On the "Network" section of the left-hand tree, setup the IP address, Subnet Mask, and Gateway for the IP100 to correspond to the appropriate subnet of the network to be used in the field. June 19, 2012 5. EXAMPLE CONFIGURATION 10 of 12

Step 5: Configure Serial Settings. On the "Serial" section of the left-hand tree, Adjust the Baud Rate and Data Format of the serial port on the IP100 you wish to connect to the field devices. NOTE: Baud rate and format must match the settings used on the field devices/radio network etc. Adjust the timeout setting for the desired port to be slightly longer than the expected response time of the field devices/serial network. Step 6: Configure Connection Type. On the "IP Mux" section of the left-hand tree, enable the first Connection line by checking the box at the front of the line. Set desired IP protocol used by the IP Master (typically TCP). Set "Count" value to indicate the maximum number of simultaneous Masters allowed to communicate to the serial devices (3 in this example). NOTE: It is recommended to allow an extra connection for remote maintenance and troubleshooting of field devices. Set IP port number to be used by the IP Master to target the IP100 COM port (502 in this example). Set COM port to be used to connect to the serial devices/network (COM2 in this example). Figure 3: IP Mux section, line 1 parameters June 19, 2012 5. EXAMPLE CONFIGURATION 11 of 12

. Bentek Systems Ltd. #315-3750 46th Ave. S.E. Calgary, Alberta, Canada. T2B 0L1 Phone: (403) 243-5135 Fax: (403) 243-5165 Email: support@scadalink.com Web: www.scadalink.com