Quickstart Strategies for Commissioning and Optimization AX2000

Demonstrating the Sigma II Indexer JUSP-NS600. Yaskawa part # DEMO4602

GSK218M Milling Machine CNC System

For more information on these functions and others, please refer to the EDC User s Manual.

micromax R Getting Started Guide

SE Motion Products: Lexium23 Plus

AN Use Beckhoff TwinCAT System Manager to configure EtherCAT masters for control of ABB MicroFlex e150 servo drives

GuardLogix Controller to Kinetix 6000 Drive with Safe-Off using EtherNet/IP CompactBlock Guard I/O Module

3000M CNC Setup Utility Manual

Intelligent Operator Panel (IOP)

G5-Series AC Servo Drives with General-purpose Pulse Train or Analog Inputs

Axidyne Multi-Axis System

Apollo I Breakout Board User s Manual

Configuration of CMMT-AS- -EC/PN to run 3rd party motor

New functionalities for LXM05 AC Servo drive Extension to product manual V1.00,

TB048 (Rev1) - Laser Mapping Procedure (Software Versions Prior to 2.61)

Three Axis CNC Driver Users Manual

APPLICATION NOTE /20/02 Getting started using IPM240-5E with a brushless motor

imach III P3A and P3A-E CNC Control Pendant

imach III P5A and P5A-E CNC Control Pendant

5000M CNC Setup Utility Manual

S700 and S300 Motion Tasking Example

Apollo III INSTALLATION MANUAL

Please read and understand this instruction manual thoroughly before using this product.

SINUMERIK 828D / 840D sl quick reference chart

Apollo III User Manual - Mach3

FX3U-20SSC-H Quick start

NI 9512 C Series Modules and AKD Servo Drives

, USA, Canada, and Mexico

Application Note. ESI File Usage. Applicable Products: Yaskawa SERVOPACKs with CANopen over EtherCAT

MRZJW3- SETUP154E. General-Purpose AC Servo Servo Configuration Software MODEL INSTALLATION GUIDE

APPLICATION NOTE. Title: SigmaLogic Example Code Example Manual. 1. Application Overview. Revision 2 February 21, 2018 Page 1 of 31

G5-series AC Servo Drives with Built-in MECHATROLINK-II Communications. 0 to +55C, 90% RH max. (with no condensation)

SMC-4000 Demo Program

DeskCNC setup and operation manual

FlexWorks Version (Supporting FSP Amplifier Version 3.23)

Motion Control Products Application note Dual encoder feedback control on motion drives

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Converting an existing Bridgeport CNC to modern control with Mach4

Table of Contents. Part I USB Communication. Part II User Interface. Part III User Settings (Tab Control) DFS-1000 Dataview. 2 File Menu.

Selecting Your Sigma II Indexer System

SD17098IX Specifications Networked Stepper Driver & Indexer Revision 0.0

Motor Objects. Methods

IEEM 215. Manufacturing Processes I Introduction to the ARIX CNC milling machine

APPLICATION NOTE

Selecting Your Sigma II Indexer System

M15 4 th AXIS UPGRADE

How to use Digital key pad (option)

Configuring Logosol CNC page 2. Setting up the machine limits and user units page 3. Setting up the Motion parameters page 4. I/O mapping page 7

Date 18/05/17. Operation and maintenance instructions for driver configurator QSet

SilverDust D2-IGF Datasheet

Simple Motion Control Connected Components Building Block. Quick Start

Create MedicCoin Master Node Instruction Rev2

Application Case. Application: Delta s AC Servo System on Robot Arms for CNC Machine Tools. Issued by Solution Center Date March 2013 Pages 5

Tolomatic Motion Interface (TMI)

Please read and understand this instruction manual thoroughly before using this product.

Mach3 USB Motion Card Installation Manual

Using SimplexMotion integrated motors for simple standalone applications

Basic Drive Programming PowerFlex 755 Basic Start Up

DCS800 Control Panel operation

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

Ether-Mach Mach3 Plugin Guide

Mitsubishi General-Purpose AC Servo Sales and Service

Galil Motion Control. DMC - 42x0. Datasheet


SERVOSTAR (S601...S620) Quickstart Guide. Version

Upgrade Information of MPE720 Version 7.30

Tri Tr t i e t x e Expert Softwar Softwar O verview Overview

WL-400 Milling Machine Operator s Manual

Upgrade Information of MPE720 Version 6.08

Please read and understand this instruction manual thoroughly before using this product.

Command Manual. -7-Series AC Servo Drive MECHATROLINK-III Communications Standard Servo Profile. MECHATROLINK-III Communication Settings

Software designed to work seamlessly with your CNC Masters machine. Made to work with Windows PC. Works with standard USB

Data Sheet MEM 16. Absolute Encoder Multiturn

SERVOSTAR 400 (S400) Quickstart Guide. Version

Troubleshooting Err27.4

Commercial and Residential Turntables. Motion Control User Manual Model MC-2

Instruction Manual for Teaching Device

PC Focus Control Operator's Guide

Preface. GSK983Ma User Manual divides into three parts, that is, Programming, Operation and Appendix.

General. Specifications. F3NC96-0N Positioning Module (with MECHATROLINK-II Interface) GS 34M6H60-02E. General. Specification

KNC-SRV-FD332S Servo Driver

SINAMICS V-ASSISTANT Online Help SINAMICS. SINAMICS V90 SINAMICS V-ASSISTANT Online Help. Preface. Safety instructions 1 SINAMICS V-ASSISTANT 2

Quick start commissioning guide. Unidrive SP. Positioning Solution. Part number : 3773 en / c

Release Notes for MPiec controller firmware

MRZJW3-SETUP221E INSTALLATION GUIDE. MR Configurator MODEL

3 CU240E-2 6SL3244-0BB12-1BA1 3 CU240E-2 DP 6SL3244-0BB12-1PA1. RS485/USS 6 3 (opt. per 2 DI) 3 CU240E-2 F 6SL3244-0BB13-1BA1

Stepper Drive Setup Guide

Transcription:

TB267 (Rev2) - CNC11 Yaskawa Sigma5 Precision Mode Setup Overview: This document will walk you through the process of configuration and tuning of a Yaskawa Sigma V Servo Drive Pack and motor with a centroid CNC11 based control, specificaly in Position Mode. Centroid's Precision Mode can provide very good resolution and high feedrates, but the following maximums should not be exceeded: MPU11 max Counts/min = 72,000,000 This maximum is derived from the maximum counts per interrupt 300 counts/int * 4000 int/sec * 60 seconds Drive max command counts per second that the drive can accept (1,200,000/s ) The following table shows examples of resolutions resulting from selected encoder counts per rev and ballscrew pitch. Encoder Counts/Rev Yielding Resolution and Speeds. 12mm Pitch Counts/Rev Resolution MaxRPM (?/Count) See Notes* 16mm Pitch Max Speed (?/Min) (mm/min) 8192 0.000058 8789 4152 49828 16384 0.000029 4395 2076 24914 24000 0.000020 3000 1417 17008 32768 0.000014 2197 1038 12457 Counts/Rev Resolution MaxRPM Max Speed Max Speed (?/Min) (mm/min) (?/Count) See Notes* Max Speed 8192 0.000077 8789 5536 88583 16384 0.000038 4395 2768 44291 24000 0.000026 3000 1890 30236 32768 0.000019 2197 1384 22146

*Yaskawa Sigma Series 5 Motors (SG-MGV) Maximum RPM = 3000 The 8192 default value referred to in the Tech Bulletin and manual refers to 8192 lines= 32768counts per rev. Prerequisites: The following items are needed: Laptop computer with the Yaskawa SigmaWin+ software installed. A to Mini-B type USB cable (Yaskawa part number JZSP-CVS06-02-E)? connected between the laptop and the Yaskawa drive you wish to setup. ServoPack Configuration Process: Launch the Yaskawa WigmaWin+ software. You will see the following screen (Illustration 1): Illustration 1: Yaskawa SigmaWin+ Launch Screen Ensure "Online" is selected as shown above

Select "Search " and make sure "?5 drives" are selected. This search should be done every time you power up the software or connect to a different ServoPack because the SigmaWin+ software remembers the last drive that was connected to it and displays that rather than what is currently connected. Select the drive that appears and click "Connect". SigmaWin+ will then open to the main screen as shown below (Illustration 2):

Illustration 2: Yaskawa SigmaWin+ Main Screen The best way to configure the ServoPack is by using the Setup Wizard, it is located under the Parameter's menu option as shown below (Illustration 3): llustration 3: Setup Wizard Menu Select the "Setup Wizard" option and the Setup Wizard shown will open (Illustration 4):

Illustration 4: Setup Wizard Click "Encoder Selection".

The Encoder should be automatically selected at this stage and you only need to click on "Apply" at the lower right have corner. The Encoder type will then be shown under the Encoder Selection button. Click "Control Mode Selection". Select "Position Control (pulse train reference)" from the drop down menu: Click "Apply". Click "Reference Input Setting "? Note: that the Control Mode setting will be highlighted in green, as you complete each section it will show green. Select "phase A + phase B" Click "Next". You will then need to select how far the servomotor will move in response to a one-pulse input. Select "4 times (multiple)" as shown below:

Click "Next". You will then be asked to Select the electronic gear setting method, select "Entr the electronic gear ratio directly" as shown below: Click "Next" You will then need to enter the gear ratio. Enter 1048576on top and 32768 on the bottom as shown in the image below: Enter 7for the Positioning Completed Width

Click "Apply" Reference Input settings will now be green.

Click "Motor Encoder Settings". Enter "8192" for the number of Encoder Pulses? This will yield 32768 Encoder counts per revolution of the motor as shown below: On the right side of the screen you will see the option to Set the dividing output according to the electronicgear ratio, as shown below. It is possible that you have gotten a motor with an absolute encoder if lead times are short and incremental encoders are not available. To use an absolute encoder the drive setting must be changed to use the encoder as an incremental encoder.: Click "Next". Select "Standard Setting":

Click "Apply".

You will be returned back to the Setup Wizard main screen, and the Encoder Settings section will now also be green. Click "Motor Stop Method" Selection. Set "Servo Off" to "0 - Stops motor by applying Dynamic Brake". Set "Overtravel" to "0 - Stops motor by applying Dynamic Brake". Set "G2 Alarm" to "0? Stops the motor by setting the speed reference to 0". If the Servo Motor has a Holding Brake you will need to select the "Use the Holding brake" option as shown below: Click "Apply". Click "IO Signal Settings", then click "Input Signal Settings". Disable "N-OT" by clicking in the "Always OFF" column as shown below. Disable "P-OT" by clicking in the "Always OFF" column as show below.

Click "OK". Click "Output Signal Settings".

For motors without Holding Brake the standard output settings is correct. For motors with a Holding Brake you must set "/COIN" and "/V-CMP" to "Always OFF". For motors with a Holding Brake you must also set "/BK" to "SO1? Output 1" as shown: below: Click "OK". You will then be returned to the IO Signal Settings screen, hit "Apply" to save the settings and then click "Save/Write". Check "Write with a backup file" this will save the current configuration and then write the current configuration fo the ServoPack: Click "Finish". Click "Yes" when prompted to complete the Setup Wizard. The ServoPack will now have an A941 Error? This indicates that a reset is required to apply the configuration changes.

To Reset the ServoPack you must click the "Software Reset" button in SigmaWin or remove power from the ServoPack. The Software Reset button is indicated below:

After pressing the "Software Reset" button you will receive a warning, simply click "Execute" to continue: Then click "Execute" at the next screen that pops up to confirm reset of the ServoPack. Every time the Drive is Reset you will normally get an error on the Centroid Control. Simply cycle ESTOPto clear the error message. Once the drive is reset you will have a "Motor Base Blocked - bb" message displayed on the ServoPack itself. This message means everything is OK. Test Run: We are now ready to perform a test run of the ServoPack and motor. This test run will be performed from the SigmaWin software using the Jog system. To enter Jog Mode select Jog from the Test Run menu: You will then see the Jog Operation Popup shown below:

Click "Edit" to change the JOG Speed. "10 RPM" is a good safe starting point. Release ESTOPon the Centroid Control. Click "Servo ON" to enable the ServoPack Motor Power.

The screen should then show "Servo ON" as shown below: You can now jog the motor by pressing and holding either the Forward or Reverse buttons If everything is workign correctly you should have smooth motion of the Servo Motor. Simple close the Test Jog popup to exit Jog Mode, the cycle ESTOP on the Centroid Control ServoPack Tuning: We are now ready to tune the Yaskawa ServoPack. There are two main options for tuning of the drive: "Tune Less Mode"? this is the default mode for the ServoPack, it obtains a stable response without adjustment. "Autotuning"? In this mode the ServoPack will attmept to tune itself to the dynamics of the system, saving the parameters for use after that. Note: Most ServoPack / Motor combinations seem to perform better once they have been Autotuned, so we will focus the rest of the time using that feature. The Tuning function is located under the Tuning menu: You will then see a safety warning about the use of Tuning? simply press "Execute" to continue.

You will then see the following Tuning Screen: Click "Execute"? this will begin the process to calculate the Moment of Inertia for the Motor system. You will then see the Condition Setting screen, click "Next". Click "Start" to transfer reference conditions to the ServoPack Click "Next". You will then see the Moment of Inertia calculation screen shown below:

Release ESTOPon the Centroid Control. Click "Servo ON" to apply power to the ServoPack Motor. Alternatingly click "Forward", then "Reverse " until the SigmaWin software will no longer allow you to press either one, signifying the completing of the movements. Click the "Next" button.

You will then see the following screen: Click the "Writing Results" button shown above to send the results to the ServoPack. Click "Finish". You will be prompted to Execute a ServoPack software Reset. Cycle ESTOPon the Centroid Control to clear any error messages generated by the ServoPack reset. You will then be returned to the Tuning screen. Click "No Reference Input" to ensure the correct mode during tuning, then click "Autotuning". You will then see the following Autotuning Set Conditions screen:

Set "Switching the moment of inertia" to "1: A moment of inertia is not presumed". Set "Mode Selection" to "2: For Positioning". Set "Mechanism Selection" to "2: Ballscrew mechanism". Ensure the Moving Range is set to "3.0" rotations, click "Next". You will receive another warning? click "Yes" to send parameters to the drive. You will then see the following Tuning Screen: Click "Servo ON". Click "Start Tuning", the ServoPack will then tune itself. Click "Finish" when tuning is complete. At this point the ServoPack and motor are tuned. Execture a Software Reset to be sure everything is back in good operation Centroid PID Configuration: We are now ready to start setting things on the Centroid side. Centroid Control Parameter 256 must be set to 2 to let the control know we are in Position Mode. When using Position Mode the Centroid PID values should all be zero'd out as shown below:

KP KI KV1 0 0 0 The Axis Encoder Counts on the Centroid must be set to the value that we used on the Yaskawa? 32768 in this case. To tune the control to any veriations in axis control you must perform a Position Mode Autotune. This is done by selecting <F5 Tune> from the PID menu. Braking Resistors: If the Yaskawa drive is wired to use an external braking resistor you must set Parameter 600 (Regenerative Resistor Capacity) on the Yaskawa to be equal to 20% of the wattage of the braking resistor. Document History Rev2 Created on 2013-02-08 by #000 Rev1 Created on 2012-07-18 by #358