A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Similar documents
A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

FortesServer An Integrated Ready to Deploy Video Management Server

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

HD Network Video Recorder Workstation

FortesServer An Integrated Ready to Deploy Video Management Server

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Cisco MCS 7845-H1 Unified CallManager Appliance

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership. Powerful Software.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

System Specifications

System Specifications

Installing the IPS 4345 and IPS 4360

GV-SNVR1600. Introduction

Cisco Nexus 9300 Series Leaf Switches for Cisco ACI. Application Centric Infrastructure

Datasheet. 10G Rack-Mountable UniFi Application Server. Model: UAS-XG. Dual 3.5" Hard Drive Bays. Dual 10G Ethernet Ports

Cisco MCS 7835-H2 Unified Communications Manager Appliance

Cisco TelePresence MSE 8000

OCMR Optical Communications Mainframe with Redundant power supplies


System Specifications

Product Specification

Cisco MCS 7815-I2 Unified CallManager Appliance

Dual Core Intel Core i3 3.3GHz Processor 4GB DDR3 RAM. 8 x 3.5 SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

StorNext M440 Site Planning Guide

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

Quad Core Intel Xeon Processor E3 NOTE: 12 x hot-swappable and lockable tray. 4 x Gigabit RJ-45 Ethernet port. Status, 10 GbE, LAN, esata, hard drives

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Cisco MCS 7815-I2. Serviceable SATA Disk Drives

MODEL NUMBER: B IP2

Intel Core i processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

MODEL NUMBER: B IP4

2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The standard system is shipped without HDD. 2. For the HDD compatibility list, please

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Dell SC7020 Storage Controller Getting Started Guide

GV-Hot Swap Recording Server System V5 (Rev.D) 4U, 20-Bay

MODEL NUMBER: B IP2-K

Features and Benefits. Certifications

System Specifications

6 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The standard system is shipped without HDD. 2. For the HDD compatibility list, please visit :

System Specifications

DL-HDM44A-H2 Quick Install Guide

Cisco Redundant Power System 2300

USB-C Multiport Dock with Power Charging USER MANUAL UH3230

NOTE: 4 x Gigabit RJ-45 Ethernet port. Status, 10 GbE, LAN, esata, hard drives. *10 GbE (reserved), esata (reserved) 2 x USB 3.

Processor Dual Core Intel Core i Processor 3.3 GHz. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

Xcellis Workflow Extender (R520) Site Planning Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

SECURE 6. Secure64 Appliances Purpose-built DNS appliances for the most demanding environments DNS APPLIANCES DATA SHEET. Appliance Descriptions

CONNECTRIX MDS-9132T, MDS-9396S AND MDS-9148S SWITCHES

Cisco Unified IP Phone 7941G

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

The Cisco MCS 7835-H2 can run any of the following Cisco applications:

8-Port DVI/USB KVM Switch with Audio and USB 2.0 Peripheral Sharing, 1U Rack-Mount, Dual-Link, 2560 x 1600

Management: Unified management of NVR, IPC, encoder, decoder, network keyboard and cloud devices; support device configuration import/export

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

HDMI and DVI Dual-Monitor Docking Station for Laptops - USB 3.0

Cisco MCS 7825-I1 Unified CallManager Appliance

HUS-NVR-7064/7128H-D 64-/128-CHANNEL1080P H.265 NETWORK VIDEO RECORDER.

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

SD4800P USB-C Triple Video Dock

QuickSpecs. StorageWorks Fibre Channel SAN Switch 16-EL by Compaq M ODELS O VERVIEW

DNS-2608 Enterprise JBOD Enclosure User Manual

Dual-core Intel Atom processor. 4 x 3.5" SATA(II)/2.5" SATA/SSD. 1.The standard system is shipped without HDD.

Compact, fanless, vibration-proof computers for rolling stock applications. Features and Benefits. Certifications

Cisco Connected Safety and Security UCS C220

Intel Compute Card User Guide v2.0. Intel Compute Card User Guide

IFS MCR-R15 Media Converter Rack User Manual

MAXPRO NVR SE (Standard Edition)

Cisco Prisma II Platform

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell MD1280 Storage Enclosure Getting Started Guide

Cisco MCS 7815-I1 Unified CallManager Appliance

CM9760-KBD and CM9760-KBR Series Keyboards FULL FUNCTION, VARIABLE-SPEED, PTZ CONTROL

Cisco MCS 7845-I2 Unified Communications Manager Appliance

Dual-core Intel Atom processor. 2 x 3.5" SATA(II)/2.5" SATA/SSD. 1. The standard system is shipped without HDD.

Vess. Architectural & Engineering Specifications For Video Surveillance. A2600 Series. Version: 1.2 Sep, 2012

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway

System Specifications

Thunderbolt 3 Multiport Dock USER MANUAL UH7230

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Cisco MCS 7825-H3. Supported Cisco Applications

DS-9500NI-RT Series NVR. Technical Specification

Models HP Z VR Backpack G1 Dock

8-Port DVI/USB KVM Switch with Audio and USB 2.0 Peripheral Sharing, 1U Rack-Mount, Dual- Link, 2560 x 1600

Network Video Recorder: NUUO NVR Titan NT-4040(R)

Network Video Recorder Quick Operation Guide

HARDWARE & ENVIRONMENTAL SPECIFICATIONS TECHNICAL BRIEF

Features and Benefits. Certifications

GigaVUE-2404 // Data Sheet

Cisco Video Management and Storage System Network Module

Transcription:

ENDURA NSM5200 SERIES NETWORK STORAGE MANAGER TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1_28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2_28 23 00 VIDEO SURVEILLANCE LEVEL 3_28 23 19 DIGITAL VIDEO RECORDERS AND ANALOG RECORDING DEVICES PART 2 PRODUCTS 2.01 GENERAL A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system. B. All systems and components shall have been thoroughly tested and proven in actual use. C. All systems and components shall be provided with the availability of a toll-free (U.S. and Canada), 24-hour technical assistance program (TAP) from the manufacturer. The TAP shall allow for immediate technical assistance for either the dealer/installer or the end user at no charge for as long as the product is installed. D. All systems and components shall be provided with a one-day turnaround repair express and 24-hour parts replacement. The repair and parts express shall be guaranteed by the manufacturer on warranty and nonwarranty items. E. The network storage manager shall be installed by an Endura -certified dealer/integrator. Certification for installation shall be conducted by the manufacturer and shall provide all necessary knowledge to fulfill the systemization and deployment across diverse networks and infrastructures, as well as provide commissioning abilities at the integrator level. 2.02 NETWORK STORAGE MANAGER A. The network storage manager shall record video and audio streams from IP cameras and video encoders on the network. B. The network storage manager shall incorporate the server functions and storage elements into a purpose-built chassis. C. The network storage manager shall use RAID 6 parity across the storage drives to protect recorded data against a hard disk drive failure. D. The network storage manager shall only use enterprise-level hard disk drives specifically rated for operation in RAID systems. E. The network storage manager chassis shall be designed for video surveillance recording applications and encompass redundancy at all vital points: Redundant, hot swappable power supply modules Redundant, hot swappable system fans Hot swappable O/S drive Hot swappable CPU fans F. The network storage manager chassis shall be designed for online service and maintenance and cannot be removed from the rack when hard disk drives, fans, power supplies, or operating system drives must be replaced.

Page 2 Endura NSM5200 Series Network Storage Manager G. The network storage manager shall be built upon a reliable and robust Linux operating system. H. The network storage manager shall support a guaranteed recording throughput of 250 Mbps per storage device with a minimum of 64 Mbps of read throughput. This throughput shall be guaranteed under normal and error (RAID rebuild) conditions. I. The network storage manager shall support any number of cameras so long as the maximum throughput required is less than 250 Mbps. J. The network storage manager shall support the recording of MPEG-4 and H.264 baseline, and high profile streams from standard resolution and megapixel cameras. K. The network storage manager shall support continuous, scheduled, alarm/event (including analytics alarms), motion, and manual recording. Pre- and post-alarm periods shall be configurable up to the total capacity of the system. L. The network storage manager shall support bookmarking and locking/unlocking of video content on the drives. M. The network storage manager shall support privacy tools that allow administrators to establish maximum retention times for normal, alarm, and locked video. N. The network storage manager shall support an intelligent video grooming protocol that can reduce the frame rate of recorded video as the video ages. Administrators shall have the flexibility to determine whether to groom alarm video or leave it at its real-time level. O. The network storage manager shall have the ability to report all diagnostic events, including software status diagnostics to a centralized user interface. In addition, Simple Network Management Protocol (SNMP) traps shall be available for monitoring through a third-party SNMP management console. P. The network storage manager shall be fully managed from a remote workstation, including the ability to configure settings and update firmware and software. Q. The network storage manager shall be capable of interfacing with the APC Smart- UPS using a USB connector. The network video recorder shall receive status and control signals from the uninterruptible power supply (UPS) when it is in backup mode. This function shall inform the operator about the amount of charge remaining and trigger a controlled shutdown when the charge becomes zero. R. The network storage manager shall meet or exceed the following design and performance specifications. 2.03 POWER SPECIFICATIONS A. Power Input 100 to 240 VAC, 50/60 Hz, autoranging B. Power Supply Internal, dual-redundant, hot-swappable C. Cable Type 2 USA (117 VAC); or 2 European (220 VAC); or 2 UK (250 VAC); or 2 Argentinian (250 VAC); or 2 Australian (250 VAC); All, 3 prongs, molded connector

Page 3 D. Power Consumption Operating Average 1. 100 VAC 262 W, 2.65 A, 895 BTU/H 2. 115 VAC 263 W, 2.31 A, 895 BTU/H 3. 220 VAC 254 W, 1.25 A, 868 BTU/H E. UPS Compatible with APC Smart-UPS, managed through the Endura product architecture 2.04 ENVIRONMENTAL SPECIFICATIONS A. Operating Temperature 50 to 95 F (10 to 35 C) at unit air intake B. Operating Humidity 20% to 80%, noncondensing C. Maximum Humidity Gradient 10% per hour D. Operating Altitude 50 to 10,000 ft ( 16 to 3,048 m) E. Operating Vibration 0.25 G at 3 to 200 Hz at a sweep rate of 0.5 octave/minute 2.05 PHYSICAL SPECIFICATIONS A. Construction Steel cabinet B. Finish 1. Front Panel Gray metallic with black end caps 2. Chassis Black matte finish C. Dimensions 1. Without Rails 24.3" D x 17.0" W x 5.2" H (61.8 x 43.2 x 13.2 cm) 2. With Rails 24.7" D x 19.0" W x 5.2" H (62.7 x 48.26 x 13.2 cm) D. Unit Weight 1. Empty (no storage drives) 46 lb (21 kg) 2. Fully Equipped (12 drives) 67 lb (30 kg) E. Mounting Desktop (feet); Rack, 3 RU per unit (Rack rails and hardware provided) 2.06 SYSTEM SPECIFICATIONS A. System 1. System Drive Linux CompactFlash system drive 2. RAID Level RAID 6 for storage drives 3. Effective Capacity Up to 9.082 TB 4. Drive Interface SATA/SATA II B. Network 1. Interface 2, 1 Gigabit Ethernet RJ-45 ports (1000Base-T) 2. Security 2 modes: secure mode (device authentication) and unsecured mode C. Auxiliary Interfaces 1. USB 2.0 2 USB 2.0 Ports on rear panel 1 USB 2.0 port on front panel

Page 4 D. Front Panel Indicators/Functions 1. Power Blue Pelco badge 2. Software Status Green, Amber Red (based on diagnostics) 3. Network Port 1 Speed/Activity Green, Amber, Red 4. Network Port 2 Speed/Activity Green, Amber, Red 5. Hardware Status Green, amber, red 6. Hard Drive Status Green, red 7. Power Button On, off (soft), off (hard) 2.07 CERTIFICATIONS A. CE, Class A B. FCC, Class A C. UL/cUL Listed D. C-Tick E. S Mark for Argentina F. CCC/CQC 2.08 STANDARDS/ORGANIZATIONS A. Pelco is a member of the MPEG-4 Industry Forum B. Pelco is a member of the Universal Plug and Play (UPnP) Forum C. Pelco is a member of the Universal Serial Bus (USB) Implementers Forum D. Pelco is a contributor to the International Standards for Organization/Electrotechnical Commission (ISO/IEC) Joint Technical Committee 1 (JTC1), Information Technology," Subcommittee 29, Working Group 11 E. Compliance with ISO/IEC 14496 standard (also known as MPEG-4) F. Compliant with International Telecommunication Union (ITU) Recommendation G.711, Pulse Code Modulation (PCM) of Voice Frequencies 2.09 WARRANTY A. 3 years, parts and labor 2.10 PELCO MODEL NUMBERS The network storage manager is capable of a maximum of 250 Mbps of throughput for incoming streams while delivering 32 simultaneous playback streams when failover is not implemented. This performance is maintained whether the system is operating under normal conditions, dealing with disk drive errors, or rebuilding the RAID array. These units (depending on model) offer 3 to 24 TB of storage. A. NSM5200-03-US in North America B. NSM5200-06-US in North America C. NSM5200-09-US in North America D. NSM5200-12-US use in North America E. NSM5200-24-US use in North America

Page 5 F. NSM5200-03-EU in the European Union G. NSM5200-06-EU in the European Union H. NSM5200-09-EU in the European Union I. NSM5200-12-EU use in the European Union J. NSM5200-24-EU use in the European Union K. NSM5200-03-UK in the United Kingdom L. NSM5200-06-UK in the United Kingdom M. NSM5200-09-UK in the United Kingdom N. NSM5200-12-UK use in the United Kingdom O. NSM5200-24-UK use in the United Kingdom P. NSM5200-03-CN in China Q. NSM5200-06-CN in China R. NSM5200-09-CN in China S. NSM5200-12-CN use in China T. NSM5200-24-CN use in China U. NSM5200-03-AU in Australia V. NSM5200-06-AU in Australia W. NSM5200-09-AU in Australia X. NSM5200-12-AU use in Australia Y. NSM5200-24-AU use in Australia Z. NSM5200-03-AR in Argentina AA. NSM5200-06-AR in Argentina AB. NSM5200-09-AR in Argentina AC. NSM5200-12-AR use in Argentina AD. NSM5200-24-AR use in Argentina AE. NSM5200F-03-US in North America; optional fibre channel

Page 6 AF. NSM5200F-06-US AG. NSM5200F-09-US AH. NSM5200F-12-US AI. NSM5200F-24-US AJ. NSM5200F-03-EU AK. NSM5200F-06-EU AL. NSM5200F-09-EU AM. NSM5200F-12-EU AN. NSM5200F-24-EU AO. NSM5200F-03-UK AP. NSM5200F-06-UK AQ. NSM5200F-09-UK AR. NSM5200F-12-UK AS. NSM5200F-24-UK AT. NSM5200F-03-CN AU. NSM5200F-06-CN AV. NSM5200F-09-CN AW.NSM5200F-12-CN AX. NSM5200F-24-CN AY. NSM5200F-03-AU in North America; optional fibre channel in North America; optional fibre channel use in North America; optional fibre channel use in North America; optional fibre channel in the European Union; optional fibre channel in the European Union; optional fibre channel in the European Union; optional fibre channel use in the European Union; optional fibre channel use in the European Union; optional fibre channel in the United Kingdom; optional fibre channel in the United Kingdom; optional fibre channel in the United Kingdom; optional fibre channel use in the United Kingdom; optional fibre channel use in the United Kingdom; optional fibre channel in China; optional fibre channel in China; optional fibre channel in China; optional fibre channel use in China; optional fibre channel use in China; optional fibre channel in Australia; optional fibre channel

Page 7 AZ. NSM5200F-06-AU BA. NSM5200F-09-AU BB. NSM5200F-12-AU BC. NSM5200F-24-AU BD. NSM5200F-03-AR BE. NSM5200F-06-AR BF. NSM5200F-09-AR BG. NSM5200F-12-AR BH. NSM5200F-24-AR in Australia; optional fibre channel in Australia; optional fibre channel use in Australia; optional fibre channel use in Australia; optional fibre channel in Argentina; optional fibre channel in Argentina; optional fibre channel in Argentina; optional fibre channel use in Argentina; optional fibre channel use in Argentina; optional fibre channel 2.11 SUPPLIED ACCESSORIES A. Power Cords 2 (based on country designation) NOTE: Units shipped to China do not include power cords. B. Rack Mount Kit Brackets, rails, and hardware C. Hard Drive Carriers 12 (all filled) 2.12 OPTIONAL PELCO MODELS A. NSM5200-PS Replacement power supply B. NSM5200-FAN Replacement system fan (upper-middle) C. NSM5200-FANB Replacement CPU fan (rear panel) D. HD5200-250 Replacement 250 GB drive and carrier E. HD5200-500 Replacement 500 GB drive and carrier F. HD5200-750 Replacement 750 GB drive and carrier G. HD5200-1TB Replacement 1 TB drive and carrier H. HD5200-2TB Replacement 2 TB drive and carrier (Revised, 3/24/10)