English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Similar documents
English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Operating Manual MLC420/422. Capacitive Level Switch. Patent no.: DE Retain for future reference V3.01

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

Englisch. Operating Manual. Capacitive Level Sensor MLC490/491/492. Retain for future reference. V3.01. Company / GHM brands

English. Operating Manual. Universal Isolating Amplifier TV125M / ST125M. Save for later reference. Companies / Brands of GHM

Operating manual GTL 142 GTL 152. Temperature probe. Please keep the manual for future use.

Operating instructions. Standstill monitor A / / 2011

Electronic Temperature Controller. Instruction Manual Version

Operating instructions. Switching amplifier DN0210 DN / / 2015

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Operating Instructions VEGAMET 381

Operating instructions. Speed monitor D / / 2014

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Operating instructions Evaluation system for flow sensors VS / / 2013

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Operating Instructions

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

PI-EX-ME-2NAM/COC-120VAC

MSI-RM2 Safety Relays

PI-EX-ME-2NAM/COC-24VDC

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

RТTH DUAL ROOM SWITCH

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

SolConeX extra-low voltage flange socket

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

Operating Instructions

PHOENIX CONTACT - 12/2007

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Operating Manual -ENGLISH- Page 1 KWG-ISO

PHOENIX CONTACT - 05/2007

Tina 1A Blanking plug

PHOENIX CONTACT Features

External level devices for conductive point level switch

ISG Isolated DIN Rail Mount Signal Conditioner Issue: Revision A Technical User Manual

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Installation instructions Inclination sensor EC2019 EC / / 2013

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Installation manual plugs and connectors with screw connection (16/32 A)

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Manometer. (Over- /Under- And Difference Pressure) Operating Manual GDH

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

B63/ NS MS. EtherNet/IP LINK

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Safety Temperature Limiter TT-STL 50

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Digital Quick-Response Thermometer

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Assembly and Operating Instructions. M2 module for BDC-i440 control units

MDM 011-Z1 Regen Resistor

IPCB42501 / IPCB42551

Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

ETD-BL-1T-OFF-CC- 10S

Operating Instructions SU 600 Ex

GMH Operating Manual for Digital Quick-Response Thermometer

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Installation Instruction. HART Add-On Module

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

TRIO-DIODE/12-24DC/2X10/1X20

Operating instructions. Monitor FD / / 2013

BT50(T) Safety relay / Expansion relay

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

Hygro-/Thermometer. Operating Manual GFTH 95

Operating instructions IO-Link master CabinetLine AL19xx

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

SSR - Supplies - Relays

TEMPERIX S Clamp. FAFNIR GmbH Schnackenburgallee 149 c Hamburg Germany

CPCI-PS24 24V-Power Supply

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

MANUAL Functional Safety

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

PSR DC/ESP4/2X1/1X2

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Universal counter UZ 9648 Counting - length measurement - metering - positioning

Transcription:

English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference

Table of contents Page 1. Proper use (application areas)... 3 Safety signs and symbols... 3 Safety instructions... 4 Product liability and guarantee... 4 Standards and directives... 4 Approvals... 4 2. Product description... 5 Delivery contents... 5 Operating principle... 5 Design of the measurement system... 6 Type designation plate... 7 3. Mounting and electrical installation... 7 Mechanical mounting... 7 Electrical installation... 8 Connection diagram... 8 4. Operating elements and functions... 9 5. Commissioning, maintenance and servicing... 12 Commissioning... 12 Maintenance... 12 Servicing... 12 6. Technical data... 13 Mechanical design/dimensions... 14 Ordering code... 14 Accessories... 15 Fault finding... 15 7. Device transport and storage... 16 8. Returns... 16 9. Disposal... 16 10. Imprint... 17 11. EC conformity certificate... 20 2

1. Proper use (application areas) Detailed information on the application area can be found in the Chapter Product description. The operating safety of the device is ensured only with proper use and observation of the information given in the operating instructions. For safety and guarantee reasons, work above and beyond that described in the operating instructions may only be carried out by personnel authorized by the manufacturer. Unauthorized conversions or modifications are expressly prohibited. In the event of improper use, this device can pose dangers, depending on the application. The device is not suitable for use in areas subject to the risk of explosion or system components relevant to safety in accordance with SIL. General safety instructions, use These operating instructions must be kept where they are immediately available to specialist personnel at all times. All procedures described in these operating instructions must be carried out only by trained personnel authorized by the operator, while wearing the corresponding protective clothing. All rights reserved. Safety signs and symbols Warning instructions are designated in this document as described below in Table 1: DANGER Table 1 Warning! This symbol warns of immediately threatening danger, death, severe physical injury or serious material damage if instructions are not followed. Attention! This symbol warns of possible dangers or dangerous situations which can cause damage to the device itself or to the environment if instructions are not followed. Note! This symbol indicates procedures which have a direct influence on operation or can cause unforeseen reactions if instructions are not followed. 3

Safety instructions Read the product description before bringing the device into operation. Ensure that the product is fully suitable for the applications in question. The operator is responsible for the problem-free operation of the device. The operator is obliged throughout the complete usage time to establish and ensure that the required working and safety DANGER measures comply with the relevant applicable regulations. Product liability and guarantee Liability disclaimer: The content of the operating instructions has been checked for compliance with the device described. Deviations cannot however be excluded, so that we offer no guarantee of full compliance. The information in these instructions is checked regularly, and necessary corrections incorporated into the following editions. We reserve the right to make technical amendments. All claims are also subject to the valid General delivery conditions for products and services of the electronics industry. GHM cannot check or repair devices without the specified, fully completed form (see chapter 8, Returns). Standards and directives Conforms to Directives : 2014/30/EU, 2014/35/EU, 2011/65/EU Harmonized standards : EN 61326-1:2013, EN 61326-2-3:2013, EN 60664-1:2007, EN 50581:2012 Approvals No licenses are given currently 4

2. Product description Conductive point level switches are mainly for watching over of levels, full and empty monitoring and dry-running of pumps. The applications come down to pipes and basins for liquid media in connection with level point sensors like type SLR4X0. The parameter settings take place user friendly via Rotary- and DIPswitches at the device. Delivery contents Level Switch This operating instruction Further documents if applicable Operating principle Conductive level switches register fluid media (not for use in areas subject to the risk of explosion). This measurement procedure makes use of the resistance of conductive liquids with AC voltage between the electrodes of the sensor. The minimal conductance of the media must not come below 2 µs. 5

Design of the measurement system Terminals for supply voltage and switch outputs Type plate Figure 1 Terminals for level point sensors (electrodes) Block wiring diagram Figure 2 6

Type designation plate The type designation plate contains the main identification data Type and article designation Technical data Serial number Figure 3 3. Mounting and electrical installation Mechanical mounting Mounting without distance is only permitted in horizontal orientation. Figure 4 7

Electrical installation DANGER The device must be installed only by a qualified electrician. The national and international regulations for the installation of electrical systems of the relevant operator country apply. Power supply to DIN EN60664-1, SELV, PELV. Electrical connection via 4 terminal strips, 4 terminals each. Screws with pressure plate, finger safe. When mounting the connection cable please note the maximum torque of the screws of 0.5 Nm. The switch function is selectable via front-side DIP-switch. Connection diagram Figure 5 8

4. Operating elements and functions Type Power-LED Switch point Switch delay NO/NC function Operating mode Status indicator for outputs Description: Figure 6 LED Power: lights green if the device is supplied. LED Out 1 and Out 2: These LEDs indicate the status of outputs S1 (Out 1) and S2 (Out 2). Switch point kω: The switch point is switchable via 9 steps in the range of 0.05 kω (20 ms) to 500 kω (2 µs) to adapt the measured medium. The hysteresis amounts to 20 % of the switch point. Switch delay sec: To compensate fluctuant media levels, it is possibility to select the on- and off-delay time from 1 s to 10 s. NO/NC function S3 n.o. ; n.c. n.o. (normally open) = NO function n.c. (normally closed) = NC function 9

Operating mode Switch ; Win/Hyst. Operating mode Switch activates the appropriate switch output of the input. Operating mode Win/Hyst intertwines the inputs. The precondition is that the position of electrode 1 at input E1 must be below the position of electrode E2 at input E2. Win/Hyst realizes a window function for output 1 and a hysteresis function of output 2. Output 2 of the MLR120 retains the condition as long as both electrodes are uncapped (Out 2 = off) or capped (Out 2 = on). This function realizes level controlling. S1 = Out 1 (MLR120) S2 = Out 2 (MLR120) Figure 7 10

Switch status Switch status Measuring value (R) Measuring value (R) GHM GROUP Martens GHM Messtechnik GmbH Functions: Switch point (Abb.7, 8) NO function (n.o.) NC function (n.c.) Measuring value 10 16 16 14 14 12 10 Measuring value (R) 12 10 Measuring value (R) 8 Switch output 8 Switch output 6 6 4 1 6 1116212631364146 4 1 6 1116212631364146 Figure 8 Figure 9 Hysteresis (Abb. 9, 10) NO function (n.o.) NC function (n.c.) Switch output Out1 Switch output Out2 Switch output Out1 Switch output Out2 0 1 2 3 4 5 6 7 8 9 10 Level 0 1 2 3 4 5 6 7 8 9 10 Level Figure 10 Figure 11 11

Measuring value GHM GROUP Martens GHM Messtechnik GmbH Delay (Abb. 11) To suppress faults or fluctuations (e.g. undulations in the tank or air bubbles in the medium) the switch outputs can be delayed. Measuring value Switch output 0 1 2 3 4 5 6 7 8 9 10 Delay time (sec) Figure 12 5. Commissioning, maintenance and servicing Commissioning Check the integrity at the sleeve. Ensure that the cable screw is fitted tightly. After switching on the auxiliary power, check the correct switching function. Maintenance No cleaning or maintenance necessary. Servicing Repairs can only be carried out at the factory. 12

6. Technical data Power supply Supply voltage : 18..230 V DC Power consumption : < 2 VA CE-conformity : EN 61326:05/2007 Ambient conditions Ambient temperature : -10..+55 C Storage temperature : -40..+60 C Relative humidity : < 75% Condensation : not allowed Measuring input Electrodes : 2 Measuring range : 9 steps selectable from 0.05 kω..500 kω Response time : 9 steps selectable from 1..10 s Accuracy : 20 % of the measuring value Hysteresis : 20 % of the switch point Minimal conductance : > 2 µs Measuring voltage : < 5 V AC Measuring current : < 5 ma Outputs 2 relay SPDT : < 250 V AC < 50 VA < 2 A ohmic load < 100 V DC < 50 W < 2 A ohmic load Indicators : LED green (power) LED red (limit Out 1 + Out 2) Case Material Weight Connection Protection class : Polyamide (PA) 6.6, UL94V-0 DIN rail mounting TS35 : 160 g slide-in screw terminals with pressure plate 0.14..2.5 mm² (AWG 26..14) : Case IP30, terminals IP20 acc. to BGV A3 13

Mechanical design/dimensions Terminals 11-14, 21-24, 31-34 Terminals 41-44 Figure 13 DIN rail mounting TS35 DIN EN 60715 Ordering code 1. 2. 3. 4. 5. MLR120 - - - - - 1. Measuring input 0 2 electrodes 2. Output 0 2 relay 3. Supply voltage 0 18..230 V AC/DC 4. Options 00 without option 5. Certificate according to DIN EN 10204. Specify only if required WZ2.2 Factory certification 2.2 Table 2 14

Accessories For level point sensors series SLR 4XX see separate product information Level conductive. Fault finding Device is not switching Fault Cause Remedy Device is always switching Table 3 No medium at the measuring tip Auxiliary voltage < 18V Short-circuit Cable break The measuring tip is in contact with the installation adapter/sleeve (soiled) No medium at the measuring tip Check auxiliary voltage at PIN 11 and 13; 18..230 V AC/DC Check wiring Check continuity of cables Clean the measuring tip Electronic defective Short-circuit in the sensor line - 15

7. Device transport and storage The case must be packed carefully and stress-free for transport (no automatic binding of the packaging). The device must be stored under the ambient conditions specified in the technical data. 8. Returns In the case you will need to send back a device for verification or repair please indicate the following details: 1. Name of the company 2. Contact person 3. Reason for return 4. Causes of failure and fault description DANGER Legal regulations for the protection of the environment and our personnel require that returned devices which had contact with liquids can be handled without any risks to personnel and the environment. If you send a device back to us for checking and repair, we must request that you pay strict attention to the following requirements: The returns form can be downloaded from our GHM homepage under: Downloads/Forms. The repair can be done quickly and without any further questions if the following points are fulfilled: 1. Every device must be delivered with a completed form. 2. The device has been cleaned and delivered in a safety package. 3. If the device was in contact with a critical media, a safety data sheet of the media must be fixed on the cover of the package. 9. Disposal The device components and packaging must be separated by materials for disposal. The legal regulations and guidelines applicable at the relevant time must be observed. The device must not be disposed of as general waste. If a device is to be disposed of, send it back to us direct with the completed Returns form specified under Point 8, and we will then take care of proper disposal. 16

10. Imprint GHM Messtechnik GmbH Site Martens, Kiebitzhörn 18, 22885 Barsbüttel Managing Director: Johannes Overhues Ulm District Court, Commercial Register section B 730462 Copyright: GHM Messtechnik GmbH. All rights reserved. Reprinting, digital use of any type and duplication is allowed only with the written permission of GHM Messtechnik GmbH. 17

18

19

BA-MA-MLR120-V1.10_E GHM GROUP Martens GHM Messtechnik GmbH 11. EC conformity certificate 20