Description. Improved Startup/Shutdown Data Collection: New Ethernet Link to Data Manager* 2000 computers. View Transient Plots during machine SU/SD

Similar documents
3500/92 Communication Gateway

3500/22M Transient Data Interface

3500/23E Transient Data Interface

3500/23E Transient Data Interface

3500/22M Transient Data Interface Module

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

3500/77M Recip Cylinder Pressure Monitor

3500/15 Power Supply. Description

3500/53 Electronic Overspeed Detection System

3500/95 System Integrated PC Display Bently Nevada* Asset Condition Monitoring

3500/25 Enhanced Keyphasor*Module

3500/45 Position Monitor

1701/05 FieldMonitor* Terminal Base Bently Nevada* Asset Condition Monitoring

3500/77M Recip Cylinder Pressure Monitor

3500/50E Tachometer Module

Vibration Transducer Interface

21000,24701 Proximity Probe Housing Assemblies Bently Nevada Asset Condition Monitoring

Bently Nevada 60M100 Monitor Bently Nevada* Asset Condition Monitoring

3500/65 16-Channel Temperature Monitor

3500/32M 4-Channel Relay Module

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring

9200, Seismoprobe

Velomitor* CT Velocity Transducer

3500/08 Diagnostics Access Panel

9200, Seismoprobe* Velocity Transducers

3500 Galvanic Isolator Interface Bently Nevada* Asset Condition Monitoring

9200, Seismoprobe * Bently Nevada* Asset Condition Monitoring

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring

3500/45E Position Monitor

3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring

Description. System Event List Alarm Event List All module and channel data Current alarm data (quick view) Nine custom display options.

PART NUMBER REVISION E, 3300 SYSTEM COMPATIBILITY GUIDE

Description. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring

21022 Dual Axial Probe Housing Assembly Bently Nevada* Asset Condition Monitoring

2300 Vibration Monitors

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Case Expansion Transducer Systems

3500 ENCORE System Overview Bently Nevada* Asset Condition Monitoring

Velomitor * Piezo-velocity Sensor

2300 Vibration Monitors

and High Temperature Velomitor * System

3300 RAM and NSv Proximity Transducer System

and High Temperature Velomitor * System

Trendmaster* Galvanic Isolator

Operation and Maintenance Manual Bently Nevada Asset Condition Monitoring. 3500/25 Enhanced Keyphasor Module. Part Number Rev.

Specifications. Inputs. Outputs. Recip Velocity. Signal. Front Panel LEDs OK LED. Input Impedance TX/RX LED. Sensor Compatibility.

3300 XL 11mm Proximity Transducer System

1900/65A General Purpose Equipment Monitor

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Description. Specifications

4110 HART Level Encoder

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

TALON Network Manager- 2 & 6 Express

3300 XL High Temperature Proximity System

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

TAC I/NETTM 1284, 1280, Security Control Unit

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

Datasheet. Overview. System Access Module

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

XPress-Pro SW User Guide

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs

6220 Ethernet-Based Voltage Measurement Module

H-series (Rectifier Module)

ADRE* Sxp/ 408 DSPi. Product Datasheet Bently Nevada* Asset Condition Monitoring. Description

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

TM241CE24T controller M IO transistor PNP Ethernet

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

TM241C40U controller M IO transistor NPN

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

TM241CE40R controller M IO relay Ethernet

ex-s1110-xt Gigabit Ethernet Extenders

TM241C24T controller M IO transistor PNP

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

TM221CE40T controller M IO transistor PNP Ethernet

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Cisco ONS CL Shelf Assembly Hardware

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

TM241CEC24R controller M IO relay Ethernet CAN master

TM241C40R controller M IO relay

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

TM221CE24R controller M IO relay Ethernet

TM241CE24U controller M IO transistor NPN Ethernet

3300 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring

TM221M16TG controller M IO transistor PNP spring

Strand Lighting Specification

Ranger* Pro Wireless Condition Monitoring

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

TM241CE40R controller M IO relay Ethernet

Corning Optical Network Evolution (ONE ) Solutions Mid-Power Remote Expansion Unit (MxU)

Transcription:

TDXnet* Bently Nevada* Asset Condition Monitoring Description The TDXnet Communications Processor provides the interface between our compatible (see note) machinery protection systems and our on-line machinery management software. It continuously collects both steady state and startup/shutdown data from all connected channels in parallel, and offers significant improvements in both data collection features and data transmission (Ethernet or serial) over previous communications processors such as TDIX, TDM, and DDM. Improved Startup/Shutdown Data Collection: New Ethernet Link to Data Manager* 2000 computers View Transient Plots during machine SU/SD SU/SD data acquisition based on Keyphasor* input Improved SDI communications with the DCS: Additional Data Types - Data access now includes rpm values and status for all four TDXnet Keyphasor transducers as part of the available data Use of RS485 with multi-drop functionality New Register Allocation - Along with the traditional grouping data by channel, TDXnet now groups MODBUS register locations by proportional data values such as Direct, Gap, 1X Amplitude, 1X Phase, etc. Maintaining same Data resolution of TDIX: Quick Connection into compatible 3300, 3500, or 2201 Monitoring Systems High Resolution Static, Orbit, and Spectrum Data Immediate Recovery from Power Loss Note: TDXnet is directly compatible with 3500, 2201, and newer 3300 systems. Through the use of TDXconnX* other monitoring systems can also be used with TDXnet. Consult (p/n 141552-01) for TDXconnX, or your local sales professional for more information Page 1 of 10

Specifications Keyphasor Inputs 4 per unit. 60 to 60,000 rpm range. Software configurable backup to real or simulated source. Startup/Coastdown Data SU/SD parameters changeable during program operation. Ability to view transient plots (e.g., Polar Plots, Bode Plots, Orbit, etc.) during a machine SU or SD without having to first upload the data. Initiation of SU/SD data collection based on detecting the Keyphasor sensor change in RPM eliminating the requirement for an externally wired contact closure. Data Two independent Startup/Shutdown buffers. One independent Delta-Time buffer. Delta time and delta RPM buffers each contain 320 vector and 32 waveform records. Vector records typically include Direct, Gap, 1X Amplitude, 1X Phase, 2X Amplitude, 2X Phase, and Not 1X for each dynamic monitor channel. Waveform records include both synchronous and asynchronous data. Option of selecting the 1X, 2X, and Not 1X data to be generated either from the monitoring system when available, or the communication processor. Waveform Sampling Waveforms are dc coupled to prevent low frequency roll off. Voltage inputs of ±25 Volts with up to 25 Volts peak-to-peak ac signal. Simultaneous Synchronous and Asynchronous data sampled during both SU/SD and steady state conditions. User configurable Synchronous data: 32 samples/rev for 32 revolutions Asynchronous data sampled to support a 400- line Spectrum at 20 khz frequency span. Asynchronous data is anti-alias filtered. Waveform data is pre-triggered. Ethernet Host to TDXnet communication link is Ethernet, 10 Mbps, and conforms to IEEE802.3. TCP/IP protocol encapsulating our BN proprietary protocol. RJ-45 (telephone jack style) and AUI 15-pin connections. SDI Data Supports both Allen-Bradley and MODBUS protocols. An RS485 communication link which supports multidrop functionality. SDI support including 1X, 2X, high-resolution gap, and NOT 1X static data. Data access now includes rpm values and their status for all four TDXnet Keyphasor Inputs. Registers organized both by channel and proportional value type configurations. System Compatible with Data Manager 2000 Version 2.0 or later and Machine Condition Manager* 2000 version 1.0 or later. Support for 3500, 3300, and 2201 monitors. Support for TDIXconnX to accommodate legacy monitoring systems. Support for Rackmate IX for multiple 3300 monitor racks to a single CP. Operates on +90 to +240 Vac, 50 to 60 Hz without any changes. It also accepts +24Vdc with modification; contact your local sales professional. Power Consumption: 89 Watts Maximum. Current draw: 0.75 Amps typical @ 110 Vac and 0.38 Amps typical at 220 Vac. 128 samples/rev for 8 revolutions 64 samples/rev for 16 revolutions Page 2 of 10

CE Mark Directives EMC Directives: Hazardous Area Approvals CSA/NRTL/C: EN50081-2 Certificate of Conformity: 158809 Radiated Emissions EN55011, Class A Conducted Emissions Approval Option (01) Class 1, Division 2 Groups A, B, C, D T4 @ Ta = 65 C EN50082-2 EN55011, Class A Radiated Susceptibility ENV50140 Certification Number CSA 150368 (LR 26744) Radio Telephone ENV50204 Conducted Susceptibility ENV50141 Electrostatic Discharge Mechanical Same footprint and bolt pattern as Transient Data Interface External (TDIX), Dynamic Data Interface External (DDIX), or Dynamic Data Manager (DDM). EN61000-4-2 Electrical Fast Transient EN61000-4-4 Magnetic Field EN61000-4-8 Weight Printed wiring assemblies shielded for protection while handling. TDXnet w/o samplers: 5.76 kg (12.7 lb.) Power Supply Dip Sampler card: 0.24 kg (8.5 oz). EN61000-4-11 Environmental Low Voltage Directives: Operating Temperature: Certificate of Conformity: 158809 0 C to +65 C (+32 F to +149 F) EN61010-1 EN61000-3- 2:1995 Safety Requirements Harmonic Content Storage Temperature: Humidity: -40 C to +85 C (-40 F to +185 F) 0% to 95% non-condensing Page 3 of 10

Ordering Information TDXnet Communication Processor 2155/00 - AXX-BXX-CXX-DXX- EXX-FXX-GXX-HXX-IXX-JXX A: Number of Sampler Cards 00 No Sampler Cards (no dynamic channels) 01 One Sampler Card (2 dynamic channels) 02 Two Sampler Cards (4 dynamic channels) 03 Three Sampler Cards (6 04 Four Sampler Cards (8 05 Five Sampler Cards (10 06 Six Sampler Cards (12 dynamic channels) 07 Seven Sampler Cards (14 08 Eight Sampler Cards (16 09 Nine Sampler Cards (18 10 Ten Sampler Cards (20 11 Eleven Sampler Cards (22 12 Twelve Sampler Cards (24 B: Cable Options 00 Cable not provided 01 3300 Cables 02 2201 Cables 03 3500 Cables 04 TDIXconnX C Approvals 00 No Approvals 01 CSA/NRTL/C 02 Not available 03 Not available 04 CE Agency Approvals 05 Multiple Approvals D: Power Supply 01 +110/+220 ac E: Sampler Card Position - Slots 1 & 2 00 No sampler card in Slots 1 or 2 10 Sampler card in Slot 1 only 01 Sampler card in Slot 2 only 11 Sampler card in both Slots 1 & 2 F: Sampler Card Position - Slots 3 & 4 00 No sampler card in Slots 3 or 4 10 Sampler card in Slot 3 only 01 Sampler card in Slot 4 only 11 Sampler card in both Slots 3 & 4 G: Sampler Card Position - Slots 5 & 6 00 No sampler card in Slots 5 or 6 10 Sampler card in Slot 5 only 01 Sampler card in Slot 6 only 11 Sampler card in both Slots 5 & 6 H: Sampler Card Position - Slots 7 & 8 00 No sampler card in Slots 7 or 8 10 Sampler card in Slot 7 only 01 Sampler card in Slot 8 only 11 Sampler card in both Slots 7 & 8 I: Sampler Card Position - Slots 9 & 10 00 No sampler card in Slots 9 or 10 10 Sampler card in Slot 9 only 01 Sampler card in Slot 10 only 11 Sampler card in both Slots 9 & 10 J: Sampler Card Position - Slots 11 & 12 00 No sampler card in Slots 11 or 12 10 Sampler card in Slot 11 only 01 Sampler card in Slot 12 only 11 Sampler card in both Slots 11 & 12 TDIX Retro Option 2155/50-AXX Accessories Interface Module 130914-01 Ethernet Hardware Ethernet Media Transceivers 02200261 0 1 Early TDIX version (Hinged sampler card cover) retrofit 0 2 Late TDIX version (Non-hinged sampler card cover) retrofit TDIXConnX 15-pin AUI male to 10Base-2 (thinnet) Page 4 of 10

Ethernet Hubs Note: The actual number of Ethernet ports, physical dimensions and manufacture of the hubs and switches may vary. Refer to relevant component description documents or contact your local sales representative for more information. Multi-port 10/100Base-TX Switch with backbone option 162419-AXX A: Backbone option 00 backbone 01 100Base-FX (MT-RJ) Backbone Multi-port Fiber Optic Switch with optional port types 142809-AXX A: Port options Ethernet Cables: 00 8 x 10Base-FL (ST) 02 8 x 10Base-FL (ST) + 4 x 10/100Base-TX (RJ-45) 03 8 x 10Base-FL (ST) + 4 x 10/100Base-TX (RJ-45) + 4 x 100Base-FX (MT-RJ) 04 8 x 100Base-FX (MT-RJ) 05 8 x 100Base-FX (MT-RJ) + 4 x 10/100Base-TX (RJ-45) 06 12 x 100Base-FX (MT-RJ) + 4 x 10/100Base-TX (RJ-45) 07 16 x 100Base-FX (MT-RJ) Standard 10BASE-T (Category 5) Cable with RJ-45 connectors (stranded patch cable) 02200230 02200231 02200232 6 ft (1.8 m) Length 10 ft (3.5 m) Length 25 ft (7.5 m) Length 10BASE-T Shielded Category 5 Cable with RJ-45 connectors (solid conductor) 138131-AXXX A: Length (in feet) up to 320 feet 040 40 ft (12 m) 050 50 ft (15 m) 075 75 ft (22.5 m) 100 100 ft (30.5 m) 10BASE-T Unshielded 120 120 ft (36.6 m) 150 150 ft (44.8 m) 200 200 ft (61 m) 250 250 ft (75 m) 320 320 ft (97.5 m) Category 5 Cable with RJ-45 connectors (solid conductor) 138171-AXXX A: Lengths (in feet) up to 320 feet 050 50 ft (15 m) 075 75 ft (22.5 m) 100 100 ft (30.5 m) 120 120 ft (36.6 m) 150 150 ft (44.8 m) 200 200 ft (61 m) 250 250 ft (75 m) Note: Standard lengths for 10BASE-T cabling are shown above. Additional lengths can be ordered through Custom Products and are available as shown below. 30 to 100 feet in 5-foot increments only 100 to 320 feet in 10-foot increments only 10BASE-2 Thinnet Cabling, PVC 103419-AXX A: Lengths (in feet) up to 600 feet 01 20 ft (6.1 m) 02 60 ft (18.3 m) 03 100 ft (30.5 m) 04 600 ft (183 m) 10BASE-2 Accessories 02291081 02291082 02291083 Fiber-Optic Cable 137451-AXXXX Ethernet BNC Connector 50 Ω terminator Ethernet BNC T-Connector Ethernet BNC Barrel Connector A: Length (in feet) up to 6500 feet (2000 metres) in length. 10 feet to 500 feet (order in 10 foot increments). 500 feet to 6500 feet (order in 100 foot increments). Page 5 of 10

SDI Communications Cable: RS485 Cable for connection from Communication Processor to a Gateway device. Contact us for information regarding Lightning Protection. Cable between Communication Processors 131179-AXXXX-BXX-CXX SDI Host to Communication Processor 131209-AXXXX-BXX-CXX Note: Maximum continuous length is 150 metres (500 feet). For lengths longer than 500 feet, use one 131179 or 131209 with as many 131210, 500 feet extensions as necessary, up to 1200 metres (4000 feet). A: Cable Length B: Kit/Assembly C: Cable type Spare Sampler Cards 123447-01 143453-01 143453-02 143453-03 0 0 1 0 10 ft (3.05 m) 0 0 2 5 25 ft (7.5 m) 0 0 5 0 50 ft (15 m) 0 1 0 0 100 ft (30.5 m) 0 2 5 0 250 ft (75 m) 0 5 0 0 500 ft (150 m) 0 1 Supplied as kit (for applications where the cable will be routed through conduit.) 0 2 Supplied as a complete assembly. 01 PVC Insulated 02 Teflon Insulated TDXnet Sampler circuit board Uninterruptible Power Supplies Uninterruptible Power Supply (UPS). 120 VAC Input / 120 VAC Output. Uninterruptible Power Supply (UPS). 230 VAC Input / 230 VAC Output. Extended External Battery Pack for the above Uninterruptible Power Supply units. (Requires Rackmate IX 2150/11-02 Spare Cables 02290163 108186-01 129386-01 02290160 either a 143453-01 or 143453-02, not a stand-alone unit.) Includes 2 each 5 foot 3300 static and dynamic cables TDXnet Communication Processor (CP) to 3300 Rack Static Data Cable TDXnet CP to 2201 Rack Static Data Cable TDXnet CP to 3500 Rack Static Data Cable TDXnet CP to 3500, 3300, or 2201Rack Dynamic Data Cable Note: These are 3.05 metres (10 feet) molded cables that connect the TDXnet to the 3500, 3300, or 2201 monitoring system. One set is included with the TDXnet when ordered. The required cables can be defined using the "B" option of the TDXnet ordering options. Spare Power Supplies 162992-01 Power Supply Field Upgrade Kit Note: This Field Upgrade Kit is for replacing the old style power supply with the new style power supply. Once this kit is in place, the new power supplies (02200625) can be ordered as spares. 02200625 Power Supply Note: This is a new style spare power supply. It is only for use with new TDXnet/TDIX units and TDXnet/TDIX units with the 162992-01 upgrade already installed. Contact your Representative for more information. TDXnet RS232/485 Converter Kit 139209-01 115 VAC Power Input Page 6 of 10

139209-02 230 VAC Power Input Page 7 of 10

Dimensional Drawings SAMPLER BACKPLANE KEYPHASOR CPU SAMPLER 12 SAMPLER 11 SAMPLER 10 SAMPLER 9 SAMPLER 8 SAMPLER 7 SAMPLER 6 SAMPLER 5 SAMPLER 4 SAMPLER 3 SAMPLER 2 SAMPLER 1 F A U L T S 161.04 (6.34) 219.2 (8.63) POWER OK PROGRAM RUNNING KPH 4 RUNNING KPH 3 RUNNING KPH 2 RUNNING KPH 1 RUNNING INITIALIZE TEST MODE S T A T U S BENTLY MADE IN U.S.A. 345.7 (13.61) 363.5 (14.31) 383.8 (15.11) 266.7 (10.5) Figure 1: Transient Data Interface External (TDIX) dimensions Dimensions are in millimetres (inches) Page 8 of 10

DYNAMIC SDIX RJ-45 STAT IC 15 Pi n AUI R R Data Manager 2000 Data Manager 2000 Display Computers Display Computers Plant Data Historian Data Acquisiton Computer with 2 Ethernet cards for connectivity to PIN and TDXnet CPs Serial Port Connection to Other Communication Processors such as DDM, SDI/DDI, SDIX/DDIX, TDM, and TDIX Plant Information Network R Data Manager 2000 Data Acquisition Computer 10BASE2 Ethernet Cable Process Control System Control Network Modbus Interface DCS Operators Console Distributed Controller 16 Port unmanaged 10BASE-T Hub with 10BASE2 Backbone P/N 142808-01 DDIX DDIX BENTLY BENTLY 10BASE-T Connections to Additional TDXnet CPs TDXnet BENTLY 25 ft. 10BASE-T cable with RJ-45 Connections P/N 02200232 DDIX BENTLY RS-422 Serial Link Connections to Monitoring Racks RS-485 Serial Link RS-485 Serial Link Figure 2: Transient Data Interface External (TDIX) clearances Dimensions are in millimetres (inches) Page 9 of 10

DYNAMIC SDIX RJ-45 BENT LY STATIC 15 Pi n AUI R Data Manager 2000 Display Computers R Data Manager 2000 Display Computers Plant Data Historian Plant Information Network Process Control System R Data Manager 2000 Data Acquisition Computer Fiber-optic Links to Other Machine Trains with TDXnet CPs Connection to Monitoring Racks 10BASE2 Ethernet Cable RS-485 Serial Cable to Additional TDXnet CPs P/N 131179-AAAA-BB-CC 6 Port Fiber Hub with 10BASE2 Backbone P/N 142809-01 Fiber-optic Cable P/N 137451-AAAA TDXnet 10 ft. 10BASE-T cable with RJ-45 Connections P/N 02200231 16 Port 10BASE-T Hub with Fiber-optic Backbone P/N 142808-02 RS485 Serial Link DCS Operators Console Control Network Modbus Interface 10BASE-T Connections to other TDXnet CPs Distributed Controller Figure 1: Fiber-optic Ethernet Links to Several Remote TDXnets. Also demonstrated is the RS485 Connection to DCS Teflon is a trademark of E.I. dupont de Nemours & Company, Inc. MODBUS is a trademark of Schneider Electric. * denotes trademarks of Bently Nevada, LLC, a wholly owned subsidiary of General Electric Company. 2000 2009 Bently Nevada LLC. All rights reserved. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 775.782.3611 Fax: 775.215.2873 www.ge-energy.com/bently Page 10 of 10