WEEKLY PROGRAMMABLE THERMOSTAT BACKLIGHTED TOUCH SCREEN CH150TS

Similar documents
Temperature control unit

Instructions manual. Thermostat User Manual

PT712-EI FOR FLOOR HEATING DIGITAL THERMOSTAT

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2

Weekday / weekend room temperature controller

Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2

7-day room temperature controller

FP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer. Installation Guide MAKING MODERN LIVING POSSIBLE

Digital Room Thermostat

Smarther X8000-X8000W

Smarther X8000-X8000W

ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual

ADVANCED REMOTE CONTROL

Model: Available in : Sapphire Black and Glacier White

Select 107 XLS User Instructions

CH140GSM2 WEEKLY PROGRAMMABLE THERMOSTAT WITH BUILT-IN GSM INSTRUCTIONS FOR USE

MDVR-14 SOLID STATE MINI DVR User Guide

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K

Model: Available in : Sapphire Black and Glacier White

Two Wire Back Flush Controller Installation and Operating Instructions Hit Products Corporation Lindsay, CA.

Programmable Room Thermostat. User Guide UFHPROGB & UFHPROGRFB

Supplementary operating instructions for your air curtain system Controller TMC 500

Touchpad User Guide (Model: C-LCD-122-TL)

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

7-day room temperature controller

Gavita Master Controller EL1

REMOTE CONTROL INSTALLATION & OPERATING INSTRUCTIONS

Weekday / weekend room temperature controller

Smart Series. Wall Heater Operations Manual. Save This Manual

TECHNICAL MANUAL. e-kronos Code CB1137. Technical manual e-kronos Rev

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

BB5023. GAMEPHONE CONTROLLER User s Manual

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Model FP700 Owner s Instructions

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Digital Room Thermostat for Underfloor Heating Applications

7 Day Digital Programmer 2 Channel Surface Mount

REMOTE CONTROL OPERATING INSTRUCTIONS

ERT50T Triac Noiseless Digital Room Thermostat for Underfloor Heating Applications

OPERATION MANUAL. Room thermostat EKRTW

Manual for the Bellfires Wi-Fi box in combination with the Bellfires Gas app

2 Zone Time Clock. User Guide UFHTIME2B

Semi flush-mounted room temperature controllers with LCD

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

The UP and DOWN buttons will toggle or scroll through the options in each section.

Model: EP210. Dual channel programmable controller. Installation Manual

USER GUIDE Digital programmable Thermostat GUIDE D UTILISATION Thermostat digital programmable 42-87

User instructions. By-me automation module for video door entry unit.

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

INSTALLATION INSTRUCTIONS

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

THE HEAT CONTROLLER RADIATOR THERMOSTAT FGBHT-001

Semi Flush-mount Room Temperature Controllers with LCD

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

ST-292 User s manual. User manual ST-292 v1-3

Semi flush-mounted room temperature controllers with LCD

7 Day Digital Programmer 1 Channel Surface Mount

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

INTRODUCTION. FX-1 Operations Manual. Standard Features. Optional Features. Read This Manual Completely Before Proceeding!

Product and Application Description

Room unit with PPS2 interface

I. PANEL DESCRIPTION... 1

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

STRA-17 Room controller. Installation and maintenance manual. Content

An energy metering system that gives flexibility, security and control. Century House, Roman Road, Blackburn, BB1 2LD

Communicative controller for VAV systems

BUP2 5/2 12/4/07 12:49 AM Page 1. Introduction

idigit CONTROL INSTALLER MANUAL Digital thermostat for fan coil units Rev100

OPERATING MANUAL. Quality control system on the production complies with requirements ISO 9001:2008

ZCM-12, ZCM-12P/U TIME PROGRAMMER WEEK S, DOUBLE CHANNEL

Product and Function Description

FANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook

Digital Photo Picture Frame With Built-in Weather Station. User s Manual

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

for User Manual for: Climatix HMI Control Panel Model POL /STD Use on: AHU Application

S-Series Digital Thermostat

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

Programmable(5+1+1)Touch Screen LCD Wired Thermostat. General. Features. Operating Algorithm

IMPORTANT SAFETY INSTRUCTIONS Do not use the product before you have studied the Safety instructions and the User Manual.

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

Model P4470 Save A Watt Operation Manual

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

4-step Chiller and Heat Pump Controller

STC7D. Digital Time Clock for TRC500 & TRC800. Installation, Operation, and Maintenance Manual

PAR-WT50R-E PAR-WR51R-E

Evolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors

ULTRASTAT23 Operating Instructions For the MEC-110 with ENHANCED SMS 10-Product Cooking Controller

OPERATION MANUAL. Remote controller BRC1D527

AirTouch 2 Zone Control System

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

domestic heating solutions ENGLISH Operating manual for Rondo-NG Dated: March

7-day room temperature controller

S-Series Digital Thermostat

Mold Control Systems, Inc.

Transcription:

WEEKLY PROGRAMMABLE THERMOSTAT BACKLIGHTED TOUCH SCREEN CH150TS

INDEX Introduction...3 Controls and indications...4 Controls...4 Indications...5 User manual...6 Setting the date and time...6 Summer/Winter selection...7 Operating modes...7 Manual operating mode...7 Automatic operating mode...8 Holiday operating mode...10 Jolly operating mode...10 OFF function...12 separate probe...15 Statistical data...15 Maintenance...16 Keyboard lock...16 Touch Screen...16 Replacing the batteries...16 Installation...18 Fastening the base...18 Electric connections...19 Fitting the batteries...20 Fastening the chronothermostat onto the base...20 Confi guring the chronothermostat...21 Technical data...25 Preset programs...13 Chronothermostat programming...13 Displaying the temperature detected by the 2

Introduction Chronothermostat CH150TS/151TS/152TS is suitable to measure the ambient temperature and to control the heating and air conditioning system to which it is connected. The operating mode can be chosen between the preset ones or can be customized according to user s needs. The wide display shows the temperature profi le i.e.: the relationship between the time table and the temperature to be kept, as well as the measured temperature, relative humidity, calculated perceived temperature, time and day of the week. The chronothermostat is battery powered. Both settings and data are stored in a non-volatile memory capable of retaining them even when batteries are down. The following external interfaces are available for CH150TS chronothermostat: Separate temperature probe; Telephone activator with GSM modem, for remote management via SMS messages. The telephone activator enables the following: remote communication with the chronothermostat to know the ambient temperature or the status of the heating or air conditioning system; remote management of the chronothermostat operating modes. The chronothermostat comes in three colours: white, silver (CH151TS series) and anthracite black (CH152TS series). Unless otherwise specifi ed, the instructions contained in this manual apply to every chronothermostat model. The chronothermostat is available in the following version: CH150TS Chronothermostat with 5 A relay 3

Controls and indications Controls 12 1 2 3 4 5 6 11 10 9 8 7 1. Button used to select the Manual operating mode or increase a value ( ) * 2. Button used to select the Automatic operating mode or decrease a value ( ) * 3. Button used to select the Holiday operating mode or go back to the previous data item ( ) * 4. Button used to select the Jolly operating mode or go to the next data item ( ) * 5. Button used for the OFF or Enter functions * 6. Button used for the Programming or Copy or Statistical data displaying functions * 7. Rotary selector for temperature correction: T1, Manual temperature, Jolly temperature, and Antifreeze temperature * 8. Rotary selector for correcting temperature T2 or the Jolly operating mode duration * 9. Rotary selector for correcting temperature T3 or the Jolly operating mode duration 10. Summer/Winter switching key and keyboard lock 11. Chronothermostat reset button 12. Backlighted area * The function associated with the button or selector depends on the current operating mode. It is highlighted by the icon placed above. 4

Indications 14 1 2 15 3 4 5 13. Summer operation 14. Battery charge level 15. keyboard lock 13 12 11 10 9 8 7 6 Note: Pressing of a key is signalled by a short acoustic signal. When ON, backlighting will stay on for about three seconds after pressing a key 1. Time 2. Temperature profi le 3. Temperature value T1 or Jolly operating mode duration (days) 4. Temperature value T2 or Jolly operating mode duration (hours) 5. Temperature value T3 6. System ON in Summer operation 7. System ON in Winter operation 8. Relative humidity percentage 9. Perceived temperature (displayed by the degree) 10. Ambient/external temperature 11. Current day (1 = Monday 7 = Sunday; 8 = Holiday) 12. Winter operation 5

User manual To operate the chronothermostat after it has been installed, proceed as follows: 1. Set the date and time. 2. Select the Summer/Winter operation. 3. Select the operating mode. 2. Modify the hour setting by means of the and buttons, then go to the minute setting by means of the button. Setting the date and time To set the current time and date, proceed as follows: 1. Enter the programming menu main page. The operating mode currently used will be interrupted temporarily. Choose the time setting function. 3. Modify the minute setting by means of the and buttons, then go to the day setting by means of the button. 4.Modify the day setting by means of the button, then press ENTER to go back to the main page of the programming menu. 6

5. Press ENTER again to exit the programming menu. The chronothermostat operating mode previously interrupted will be resumed. Operating modes The CH150/151/152 chronothermostat features four different operating modes: Manual, Automatic, Holiday and Jolly (in addition to the OFF function). Summer/Winter selection To shift from the Summer operation (heating system) to the Summer operation (cooling system), and vice versa, keep the Summer/Winter button depressed for at least 4 seconds. The selected operation will be shown on the display by means of the Winter or Summer icons. Manual operating mode With the Manual operating mode, the chronothermostat adjusts the operation of the heating or cooling system in order to always keep the same temperature. To select Manual, press MAN. Winter Summer 7

The temperature level can be modifi ed during operation by means of the lower rotary selector located on the right side of the chronothermostat. The temperature can be changed from 2 C to 40 C by 0.1 C increments. Automatic operating mode With the Automatic operating mode, the chronothermostat adjusts the operation of the heating or cooling system by following the profi les defi ned for the various days of the week. To select Automatic, press AUTO. The three temperature levels used can be modifi ed during operation by means of the rotary selectors located on the right side of the chronothermostat. 8

Temperature T3 cannot be lower than temperature T2 or higher than 40 C. During Summer operation, temperature T3 features an upper limit of 30 C. When this value is exceeded, T3 will take the OFF value, which will involve switching the system off. Temperature T1 cannot be higher than temperature T2 or lower than 2 C. Temperature T2 cannot be higher than temperature T3 or lower than temperature T1. If no customization has been made, the automatic operating mode will function with the stored temperature profi les, i.e. the preset ones (refer to «Preset programs»). To customize the profiles, refer to «Chronothermostat programming». 9

Holiday operating mode With the Holiday operating mode, the CH150 chronothermostat CH150 adjusts the operation of the heating or cooling system by following one single temperature profile, which is valid for all days. To select Holiday, press HOLIDAY. Jolly operating mode With the Jolly operating mode, the CH150 chronothermostat interrupts the current operating mode and adjusts the operation of the heating or cooling system to keep the Jolly temperature during the entire time set (1 hour to 99 days and 23 hours, by 1 hour increments). After this time which is displayed like a countdown has elapsed, the previous operation of the chronothermostat will be resumed. To select Jolly, press JOLLY. To modify the temperature levels, refer to the description of the Automatic operating mode. When the preset programs are used (refer to «Preset programs»), the Holiday mode will follow the profi le envisaged for Saturdays and Sundays. To create a customized Holiday program, refer to «Chronothermostat programming». The Jolly temperature value and the operating mode duration can be modifi ed by means of the rotary selectors located on the right side of the chronothermostat. 10

Use the lower rotary selector to modify the temperature level. The temperature can be modifi ed from 2 C to 40 C, by 0.1 C increments. To set the Jolly operating mode duration, i.e. days («d»), use the upper rotary selector. The days can range from 0 to 99. To set the Jolly operating mode duration, i.e. hours («h»), use the central rotary selector. The hours can range from 0 to 23. You can interrupt the Jolly mode at any time, by selecting any other operating mode. The Jolly operating mode can be used, for instance, to: save energy by lowering the temperature when the house is not inhabited at the weekends or winter vacation, while being sure that a comfortable temperature will exist when the house is inhabited again); extend the night heating or cooling beyond the usual time, i.e. when you stay up in the company of your guests. 11

OFF function The OFF function can be activated by pressing OFF. Winter operation Summer operation The chronothermostat adjusts the operation of the heating system to keep the Antifreeze temperature, in order to reduce the energy consumption and, at the same time, avoid any damage caused by extremely low temperatures. The Antifreeze temperature can be modifi ed from 2 C to 7 C (by 0.1 C increments), by using the lower rotary selector. If a temperature of less than 2 C is set, the system will be fully turned off and the antifreeze protection will be lost. The system will be fully turned off and the OFF message will appear on the display, without any temperature profi le. 12

Preset programs The CH150 chronothermostat features two preset programs (i.e. Winter and Summer ) for quicker start-up. Winter program working days (Mondays through Fridays) Chronothermostat programming You can customize the temperature profi les for the Automatic and Holiday operating modes, so as to adapt them to your own needs. To set new temperature profi les, proceed as follows: 1. Enter the programming menu main page. The operating mode currently used will be interrupted temporarily. Choose the temperature profile customization function. Winter program public holidays (Saturdays, Sundays and Holiday program) Summer program (All days of the week, plus Holiday program) 13

2. The Monday profi le (DAY 1) for Winter operation (icon ) will be displayed. Use the and buttons to move the bar chart blinking segment to the time at which the temperature is to be modifi ed. Each segment equals half an hour. To modify the Summer operation profi le (icon ), press the Summer/Winter button on the left side of the chronothermostat. 4.To directly duplicate the temperature profi le by going to the next day, press COPY (to customize every single day separately, refer to step 5 below). 3. Use the and buttons to modify the temperature level (T1, T2 or T3). 5. Press ENTER to go to the next day, then repeat the operations described starting from step 2 for the other days of the week (the Holiday profi le will be indicated as DAY 8). To go back to the programming menu main page, use the ENTER button to scroll through the eight days or keep the ENTER button depressed for 3 seconds. If no button is pressed within the next three minutes, the chronothermostat operating mode previously used will be resumed. 14

Preset parameter reset To resume the preset temperature profi les and values (T1-T2-T3-Temperature used with the Manual mode, Temperature used with the Jolly mode, Antifreeze temperature, OFF function), keep the and buttons depressed simultaneously when you are in the temperature profi le programming mode. Displaying the temperature detected by the separate probe To display the temperature detected by the separate probe (only if the latter has been confi gured as an external probe or fl oor-mounted probe), the chronothermostat must be configured (refer to <<chronothermostat configuration>>) and the probe must be connected. To display the temperature value read by the separate probe, press the button of the operating mode currently used (the temperature will blink). To display again the temperature detected by the chronothermostat, press again the button of the operating mode currently used (the temperature will not blink any longer). Statistical data The CH150 chronothermostat provides a set of statistical data concerning the system operation. To access this data, proceed as follows: 1.Enter the programming menu main page. The operating mode currently used will be interrupted temporarily. Choose the statistical data function. 2. Page 1: number of hours during which the system was operated on the previous day (6 hours in the image). Use the button to go to the next page. 15

3. Page 2: total number of hours during which the system has been switched on and operating since its fi rst start-up (16 hours in the image). Use the button to go to the next page. Press the and buttons simultaneously to reset the total system switch-on hours. 4.Page 3: minimum temperature reached on the current day, and time at which such minimum temperature was reached (15.8 C at 03.15 a.m. in the image). Use the button to go to the next page. 5. Page 4: maximum temperature reached on the current day, and time at which such maximum temperature was reached (22.5 C at 09.08 p.m. in the image). 6. Press the ENTER button twice to go back to the operating mode previously used. 16 Maintenance To clean the chronothermostat use a soft cotton cloth and no detergent. Do not use paper handkerchiefs to clean the touch screen. Keyboard lock To clean the chronothermostat without changing accidentally its settings, press the Summer/ Winter key in order to activate the keyboard lock. When the keyboard lock is ON, symbol on the display will turn on. The display can now be cleaned, each time a key is pressed symbol will fl ash. To restore keyboard operation, press again the Summer/Winter key, symbol will turn off. Touch Screen The touch screen surface is highly scratchable. Only use your fi ngers to touch the screen. Never use pens, pencils or other pointed objects. Replacing the batteries When the battery charge starts to lower, symbol on the display will start fl ashing. If the batt parameter is set to On or to Off (see paragraph <<confi guring the chrono-

thermostat>>) and batteries are not replaced within 15 days, the chronothermostat will turn off automatically and the display will show the message OFF or On instead of the temperature value. Settings and data are however stored in the non-volatile memory. To remove the chronothermostat from the base proceed as follows: remove the jack plug from the telephone activator, if any; pull the left and right sides of the chronothermostat, without applying force to selectors. Important: Standard battery life is approx. 1 year. You are recommended to replace batteries at the beginning of system operating season to prevent batteries from running down when you are away from home, e.g. during Christmas holidays. The batteries shall be properly disposed of in special containers. If after replacing the batteries, the display only shows the message OFF or On, press the icon key with ENTER after refi tting the chronothermostat on the base. With the batt parameter off (see paragraph <<confi guring the chronothermostat>>), and symbol fl ashing, batteries shall be changed as soon as possible to prevent that battery charge becomes insuffi cient for regular chronothermostat operation. 17

Installation Caution: The chronothermostat shall be installed by qualifi ed personnel only, in compliance with the current regulations in force. 83 60 Chronothermostat installation involves the following operations: Fastening the base. Electric connections. Fitting the batteries. Fastening the chronothermostats onto the base. Confi guring chronothermostat parameters. Fastening the base The chronothermostat comes with a base suitable for wall mounting or for fl ush-mounting in three-module rectangular or round boxes. SPACING DIMENSIONS FOR FIXING THE BASE Separate the base from the chronothermostat levering on the slot located at the bottom of the base by means of a proper tool. Make sure that the base is properly secured and it is not deformed. Check that the chronothermostat multi-pole connector is placed at the bottom left corner. 60 18 To ensure correct operation the base shall be installed at about 1.5 metres above the fl oor level and far from heat sources (heating radiators, direct sunlight, etc.), doors and windows.

Electric connections Before making connections, remove the terminal protection guard (keep it together with the fastening cross-slotted screw). Protection guard fastening screw Connecting the heating or air-conditioning system 2.5 mm2 max section. Terminal 4 is free and may be used for signalling or other use, as necessary. Neutral Phase 4 1 2 LOAD Chronothermostat relay terminal block LOAD = burner - circulation pump Warning: Make sure the relay load value is not exceeding the values specifi ed in «Technical data». Connecting the separate temperature probe Connect the two wires of the heating or airconditioning system to the terminals 1 and 2, as shown in the fi gure. Terminals are suitable for fl exible cables with 19

Connect the two wires of the separate temperature probe to terminals A and B, as shown in the fi gure. Connecting the telephone activator CTx terminal block 1 2 3 Separate temperature probe 3 2 1 B A CH150 terminal block Connect the three wires of the telephone activator to terminals 1, 2 and 3, as shown in the fi gure. As an alternative, the activator may be connected through the 3.5 mm jack plug set on the left side. Once connections are over, refi t the terminal protection guard removed previously. Fitting the batteries Fit two long-life 1.5 V AA alkaline batteries into the back of the chronothermostat, observe the specifi ed polarity. After fi tting the batteries the chronothermostat will turn on automatically. Fastening the chronothermostat onto the base Press by hand the chronothermostat onto the base, make sure the multi-pole connector fi ts properly. The chronothermostat will click into position. 20

Configuring the chronothermostat Warning: The chronothermostat shall be confi gured by qualifi ed personnel only. Chronothermostat confi guration enables to customize the operating parameters. To open the confi guration program, proceed as follows: 1. Press the SET / PROG key [key 6]. The operating mode being currently used will be temporarily stopped and it will be resumed automatically at the end of programming. 2. Keep the SUMMER / WINTER switching key [key 10] pressed for about 5 seconds. To go back to the initial page of the programming menu, press the ENTER key [key 5] which will save changes. If no key is pressed within 3 minutes, the chronothermostat will quit the confi guration program and will resume the operating mode being used previously, without saving changed settings. To cancel changed settings and to reset preset confi guration parameter values, keep keys [key 1] and [key 2] pressed simultaneously for about 4 seconds. Every confi guration parameter featuring preset settings is identifi ed on the display by an index and a writing. To change parameter values use keys [key 1] and [key 2]; use key [key 4] to move across parameters. 21

Parameter Writing Values Preset value 1 Type of connected COn rel / rad / --- none card 2 Temperature scale CELS o C / F C FHAr 3 Type of regulation Std o Std / ProP Std ProP 3A Thermal DIFF HI / LO LO differential 3A Regulation band BAnd 1 C 4 C (step 0.1 C) 2 C 3B Regulation period Per 5 / 10 / 20 minutes 4 Separate Sect temperature probe confi guration 4A Floor temperature limit 5 Ambient temperature correction --- / FLO / In / Out Tfl o 15 C 45 C Corr -4.0 C to +4.0 C 10 minutes --- 27.0 C 0.0 C 6 Optimization Opt ON/OFF OFF 6A Max. optimization OPtH 1h 5h 2h duration (hours) 7 Pump anti-seizure Pu ON/OFF OFF 22 Index Index Parameter Writing Values Preset value 8 Low battery batt --- / On / OFF OFF 9 Software release SOFt xxx xxx Type of connected card The chronothermostat can check whether the base is connected. If it is not connected dashes will be displayed whereas when it is connected the writing rel is displayed. Writing rad is displayed in radiofrequency versions. Temperature scale To select the temperature scale to be displayed: Celsius (centigrade) or Fahrenheit. When choosing the Fahrenheit scale, temperatures may range between 0.0 and 99.9 F. Type of regulation To select the temperature regulation mode: differential (Std) or proportional (ProP). This parameter is used for heating only. Thermal differential To set the thermal differential value to be used

when choosing the differential temperature regulation mode. Continuous switching on and off can be avoided by choosing a proper differential value according to the thermal inertia of the heating system. It is recommended to set a low thermal differential (LO) in heating systems with radiators and high thermal differential (HI) in heating systems with fan-coils. Regulation band To select the proper value according to the thermal gradient of the system (broadband for high gradients narrow band for low gradients). Regulation period To set the regulation cycle length (ON period + OFF period) when the proportional temperature regulation mode is chosen. Select 5 minutes for low-inertia systems (fan-coil type), 10 minutes for average-inertia systems (aluminium radiator type) and 20 minutes for highinertia systems (cast-iron radiator type). Separate temperature probe configuration The chronothermostat may be connected to a separate temperature probe. Probe operation 23 is determined by this parameter. Probe off (---): the temperature value detected by the probe is not used (although the probe is connected). Floor probe (FLO): when the temperature detected by the probe reaches the value set in the Floor temperature limit parameter, the system will be turned off regardless of the temperature read by the chronothermostat. Ambient probe (In): system regulation is based on the temperature value detected by the separate probe. This temperature value is displayed instead of the temperature value detected by the internal probe of the chronothermostat. The separate ambient probe is used when the chronothermostat is necessarily located in a room other than the one the temperature of which is to be controlled; External probe (Out): has no effect on system regulation, it is just used to know another temperature, e.g.: the outside temperature. Floor temperature limit To set the temperature limit value read by the separate probe which turns the system off when the fl oor probe is used (for fl oor heating systems).

Ambient temperature correction To sum/subtract an offset value to/from the temperature value read by the chronothermostat. Optimization To calculate the advance switch-on time required to reach the desired temperature at the set time, considering the system thermal inertia. Optimization takes place only at the fi rst switch-on of the day, i.e.: the fi rst programmed passage from a temperature to a higher one. Low Battery To determine the relay status when batteries are fl at for over 15 days. If this parameter is excluded (---), the chronothermostat will keep on controlling the relay as required by regulation until the remaining battery charge allows for it. Max. optimization duration To set the max. duration (expressed in hours) of the advance switch-on time calculated by optimization. Pump anti-seizure To turn the system on for 1 minute a day (h 23.58), thereby operating the water circulation pump and preventing it from seizing. This takes place only if the system has never been turned on during the day. 24

Technical data Power supply 2 AA alkaline batteries, 1.5 V Battery life about 1 year Outputs 1 single-pole relay voltage 250 Va.c. rating 5(3) A Inputs Telephone activator Separate temperature probe Electric connections Screw clamps 3.5 mm twopole jack plug Insulation Double Protection Setting storage Micro-disconnection Software Temperature regulation range Anti-freeze temperature regulation range Max. temperature Local indication IP20 Non-volatile memory 1BU Class A 2 C 40 C 2 C 7 C T45 Backlighted LCD display 25 Local controls Touch screen, 6 icon keys 1 central backlighted area 3 rotary selectors Dimensions (L x H x D) 155 X 91 X 20 Separate temperature 10 m max probe distance Reference thermal gradient Relative humidity displayed value 4 K/h 20% - 90% Pollution degree 2 Impulse Voltage 4000V Complies with EN 60730-1 and second parts ErP classifi cation: ErP Class IV; 2% (EU Reg. 811/2013-813/2013) Fantini Cosmi S.p.A. reserves the right to make whatever technical and manufacturing modifi cation without prior notice.

NOTES 26

DISPOSAL OF PRODUCTS The crossed out wheeled dust bin symbol indicates that products must be collected and disposed of separately from household waste. Integrated batteries and accumulators can be disposed of with the product. They will be separated at the recycling centres. The black bar indicates that the product was placed on the market after August 13, 2005. By participating in separate collection of products and batteries, you will help to assure the proper disposal of products and batteries and thus help to prevent potential negative consequences for the environment and human health. For more detailed information about the collection and recycling programmes available in your country, please contact your local city office or the shop where you purchased the product.

FANTINI COSMI S.p.A. Via dell Osio, 6 20090 Caleppio di Settala, Milano - ITALY Tel. +39 02 956821 Fax +39 02 95307006 info@fantinicosmi.it EXPORT DEPARTMENT Ph +39 02 95682229 export@fantinicosmi.it GB79344C www.fantinicosmi.com