Order code: EQLED53 User manual

Similar documents
LIGHT BRICK - 12 X 3W TRI-COLOUR

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

order code: EQLED40 user manual

w w w. p r o l i g h t. c o. u k STAGE PAR 64

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

Order code: EQLED60 USER MANUAL

Blitzer Strobe. User Manual. Order code: EQLED366

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

UV Spectra Batten 12 x 5W UV LEDs

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Professional DMX Stage Backdrop

IMPACT Order code: EQLED79

UV Power Flood. User Manual. Order code: EQLED029

Crossfire. User Manual. Order code: EQLED061

Colour Burst Order code: LEDJ01 USER MANUAL

Fusion Saber. User Manual. Order code: EQLED070

Slimline CW & WW Series

RGB Power Batten. User Manual. Order code: EQLED032

Gobo Projector XP 80W

Blitzer RGB Strobe. User Manual. Order code: EQLED365

CDP 405 Digital Dimmer Pack

Vector Beam White. User Manual. Order code: LEDJ265

MICRON DJ Booth Tri-colour Starcloth

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Performer 18 RGBWA MKII

Microbar COB System. User Manual. Order code: EQLED137

CS2 DMX Distribution Splitter

MICRON DJ Booth System with Overhead Kit & CW Starcloth

DMX LED Starcloth Systems

Hypnos. User Manual. Order code: EQLED372

PF LED Profile. User Manual

ZF LED Zoom Fresnel. User Manual

Vortex. User Manual. Order code: EQLED073

Microbar Multi System

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

Saturn Spot. User Manual. Order code: EQLED023

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

EasiLED 4 DMX Controller

Endura 1Q120 RGBW COB Exterior Fixture

Intense 9P10 RGBWA LED Slim Par

Intense 9HEX10 LED Slim Par

SP-1500 DMX MK II Strobe

TRANSCENSION Show Control

Slimline 12Q5 Series

User Instructions. American DJ

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

Fresco 24 RGBW. Exterior Fixture User Manual. Order code: LEDJ267

FTP1 Single Channel LED DMX Driver

50W/100W LED Alu. User Manual. Code: ELUM041-50W - (5600K) Code: ELUM041A - 100W (5600K) Code: ELUM041C - 50W - (3200K) Code: ELUM041D - 100W (3200K)

order code: EQLA04 user manual

Flexoled FTP3HP RGB LED DMX Driver

Party Dimmer IEC ORDERCODE 50324

CPA 40 Two Channel Amplifier

Heavy Duty DMX Mirror Ball Rotator with Safety Eye

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

1 Channel Strobe Controller ORDERCODE 40226

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

Octostrip ORDERCODE 42220

LED Par 64 Short DMX ORDERCODE 42431

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

LED W RGBA User Manual

LED Dancefloor ORDERCODE 42300

Blue Weapon Laser. User manual UK. Version 1.0

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Light Brick ORDERCODE 50370

Antenna Distributor ORDERCODE D1444

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Multidim ORDERCODE 50391

D-Pack 6 Classic ORDERCODE 50315

FLEX BEAM V8. User Manual Please read the instruction carefully before use

1 Channel Sliding Profile Dimmer ORDERCODE 50425

Spectrum Laser. User manual UK. Version 1.0

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

Robot Light V2. User Manual

Colour Star Sky I DMX ORDERCODE 40341

Titan Strobe ORDERCODE 40222

TourPro RGBAW Stagebar USER MANUAL

Showdesigner 512 ORDERCODE 50721

Shogun DJ G-40 ORDERCODE 32000

User Instructions. American DJ Charter Street Los Angeles Ca

DarkFX Spot 670 User Manual English

PROFESSIONAL SHOW LIGHT

36LEDs Par Light. User Manual

Warning... Safety-instructions Operating Determinations Rigging... Description... Features and Overview...

RGBW PAR CANS. Item ref: SL-FC3, SL-36, SL-64, SL-SW, SL-Q8, SL-Q12 User Manual. Errors and omissions excepted. Copyright AVSL Group Ltd.

LED Giga Bar 4. User Manual

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

ALO Duo Roll DMX LED barrel scanner with dual light source

Large Police Light 100W ORDERCODE 80361

TDC Power Derby DMX LED light effect

LED DANCING FLOOR User Manual

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

ELED FRESNEL 100WW. User Instructions. Elation Professional 6122 S. Eastern Ave. Los Angeles CA

LED PAR56 Order Code: P56-151

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

Transcription:

www.prolight.co.uk Order code: EQLED53 User manual

Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain, moisture and liquids. SAFETY INSTRUCTIONS Every person involved with the installation, operation & maintenance of this equipment should: - Be competent - Follow the instructions of this manual CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!! Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any, consult your dealer and do not use the equipment. To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual. Please note that damages caused by user modifications to this equipment are not subject to warranty.

Safety IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. Never let the power-cable come into contact with other cables. Handle the power-cable and all mains voltage connections with particular caution! Never remove warning or informative labels from the equipment. Do not open the equipment and do not modify the equipment. Do not connect this equipment to a dimmer-pack. Do not switch the equipment on and off in short intervals, as this will reduce the system s life. Only use the equipment indoors. Do not expose to flammable sources, liquids or gases. Cleaning must be done at regular intervals. Before cleaning, wait until the unit has cooled. Use a vacuum or dry compressed air and a soft brush to remove the dust collected on the external vents and accessible internal components. Clean the external surfaces with a mild solution of non-ammonia glass cleaner or isopropyl alcohol and wipe with a soft, lint free cotton cloth or lense cleaning tissue. Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable. Make sure that the available voltage is between 100V/240V. Make sure that the power-cable is never crimped or damaged. Check the equipment and the power-cable periodically. If the equipment is dropped or damaged, disconnect the mains power supply immediately. Have a qualified engineer inspect the equipment before operating again. If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature. If your product fails to function correctly, discontinue use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Prolight dealer for service. Only use fuses of same type and rating. Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. WARRANTY; One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g.: short-circuit, burns, electric shocks, LED failure etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and property.

Technical specifications You should find inside the Equinox carton the following items: 1, Equinox Domin8R 2 2, Power cable 3, Instruction manual Technical Specifications: DMX channels: 8 or 16 selectable 120 x 5mm LEDs (R: 40, G: 40, B: 40) Sound active, auto, master/slave and DMX modes IEC power in/out sockets 3-pin XLR in/out sockets 4 push button menu with LED display Robust metal housing Convection cooled Power supply: 100-240V~50/60Hz Fuse: 3 Amp Power consumption: 90W Dimensions: 906 x 112 x 317mm Weight: 10.4Kgs Overview: Identification: 1. Hanging bracket 2. IEC power in/out socket 3. Earth screw 4. DMX output socket 5. DMX input socket 6. Sensitivity control 7. LED display 8. Function buttons 9. Hanging bracket tightening knobs 10. Safety eye 11. Microphone

Operation Operation modes: DMX mode: To select DMX mode, press the MENU button to show ADDR on the display. Now press the ENTER button and use the UP and DOWN buttons to set the DMX address from 001-512. When you have finished setting the desired DMX address press the ENTER button. For DMX functions, please refer to the DMX function chart overleaf. DMX channel mode: To choose one of the DMX channel modes, press the MENU button to show CHND on the display. Now press the ENTER button and use the UP and DOWN button to choose the 8 or 16 DMX channel mode. To confirm your choice, press the ENTER button. Master/slave mode To select the slave mode, press the MENU button to show SLND on the LED display. Now press the ENTER button and use the UP and DOWN buttons to select either MAST, SLA1 or SLA2. MAST option: This is the master setting mode, where you can set the first unit as a master. SL-1 option: This is the normal slave mode, where the slave units all do the same thing following the master unit. SL-2 option: This is the inversion slave mode, where the slave unit(s) will react in the opposite direction from the master unit. Sound active mode: To select sound active mode, press the MENU button to show SOUN on the LED display. Now press the ENTER button and use the UP and DOWN buttons to set the sound active mode ON or OFF. The unit will now react to the beat of the music. Note: When there is no music present the unit will automatically switch to slow auto run. LED mode Use this mode to turn the LED display ON or OFF. To do this, press the MENU button to show LED on the display. Now use the the UP and DOWN buttons to select either ON or OFF. Display mode In this mode you can flip the display over to match which way the unit is being used. To flip the display, press the MENU button to show DISP on the display. Now press the ENTER button to flip the display over and again to flip it back to its original position. Test mode In this mode you can test that all of the LEDs are illuminating. To do this, press the MENU button to show TEST on the display. Now press the ENTER button to initiate the test. Once you are happy with the test, press the ENTER button to stop it. Hour mode (non re-settable) In this mode you can check the total time the unit has been used for. To check the units time line, press the MENU button to show HOUR on the display. Now press the ENTER button to display the units time usage. For example if the unit has been in use for 5 hours the display will show - - - 5. If the unit has been in use for 120 hours the display will show -120 and so on.

DMX Charts 8 channel DMX chart: CHANNEL 1 2 3 4 5 6 7 8 VALUE 0-127 128-255 0-255 0-255 0-255 0-127 128-255 0-255 0-127 128-255 0-255 FUNCTION No function On Strobe (slow to fast) Static pattern selector Moving pattern selector Static pattern Moving pattern Moving pattern speed (slow to fast) Manual mirror tilt Auto mirror tilt (up and down) Mirror tilt speed

DMX Charts 16 channel DMX chart:

DMX Set up DMX-512: DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures (most controllers only have a data out terminal). DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain. DATA Cable (DMX cable) requirements (for DMX operation): The Equinox Domin8R 2 can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/ output (figure 1). Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers. Please quote: CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split.

DMX Set up Notice: Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing. Grounding the shield could cause a short circuit and erratic behaviour. Special Note: Line termination: When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. Termination reduces signal transmission problems and interferance. it is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture. Using a cable terminator (part number CABL90 3-pin, CABL89 5-pin) will decrease the possibilities of erratic behaviour. 5-Pin XLR DMX Connectors: Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The Chart below details the correct cable conversion.

Notes Notes:

Notes Notes: