FWA-6510 function Setting Introduction APPROVALS Name (printed) Title Signature Date
Version: V1.0 Page 2 of 41 HISTORY Revision Date Person Description V1.0
Version: V1.0 Page 3 of 41 CONTENT CONTENT... 3 1. IPMI command for LAN Bypass... 4 1.1 NMC card installation... 4 1.2 IPMI environment Setting... 4 1.3 IPMI Command for LAN Bypass Setting... 5 1.4 IPMI LAN Bypass control for NAEM-0103 LAN module... 6 1.4.1 Hardware description... 6 1.4.2 IPMI LAN Bypass setting... 8 1.5 IPMI LAN Bypass control for NMC-0107/0803 LAN module:... 12 1.5.1 Hardware description... 12 1.5.2 IPMI LAN Bypass setting... 14 2. FWA-6510 IPMI WDT system reboot Setting... 20 3. FWA-6510 GPIO control Setting... 23 4. FWA-6510 graphic LCM utility... 25 5. FWA-6510 BMC firmware upgrade... 31 6. FWA-6510 IKVM Operation... 36 7. BIOS function setting... 38 7.1 BIOS power status setting... 38 7.2 BIOS LAN Bypass setting... 40
Version: V1.0 Page 4 of 41 1. IPMI command for LAN Bypass 1.1 NMC card installation When customer installs NMC card in FWA-6510, kindly turn off power and unplug power cord first, otherwise, FWA-6510 is unable to detect new installed NMC card 1.2 IPMI environment Setting The below list is the FWA-6510 BMC default information included user name & password User name: admin Password: admin Parameter Name Default Value IP Address of LAN interface 0.0.0.0 Subnet Address of LAN interface 255.255.255.0 User IDs (User/Password/Privilege/Channels) User ID 1: User ID 2: NULL/NULL/USER/LAN admin/admin/administrator/lan LAN Channel PEF Alerting Per-message Authentication User Level Authentication Access Mode Privilege Level Limit Disabled Disabled Enabled Always Available Administrator IPMB Slave Address KCS Base Address 20h CA8h (SMS)
Version: V1.0 Page 5 of 41 Please use the below commands to set the IPMI environment before using the IPMI command. modprobe ipmi_devintf modprobe ipmi_msghandler modprobe ipmi_si type=kcs ports=0xca8 regspacings=4 1.3 IPMI Command for LAN Bypass Setting #ipmitool i2c bus=1 0xAA 0xBB 0xCC 0xDD 0xEE 0xAA: I/O Address 0xBB/0xCC: IPMI Offset 0xDD/0xEE: IPMI control value
Version: V1.0 Page 6 of 41 1.4 IPMI LAN Bypass control for NAEM-0103 LAN module 1.4.1 Hardware description The NMC slot s PCI-e buses of FWA-6510 are control by Xeon CPU. CPU 1 is control NMC slot 1/2 & 5/6 (only for 6NMC). CPU 2 is control NMC slot 3/4 & 7/8 (only for 8NMC). If customer needs using all NMC slot, please install dual CPU in FWA-6510 FWA-6510 is using the 8-channel I2C bus switch chip to redirect the SM-Bus from motherboard to NMC by middle board, the I/O address of 8-channel I2C bus switch chip is E2. The Switch sequence is from right to left, and from down to up The NMC sequence of FWA-6510 4MNC Version
Version: V1.0 Page 7 of 41 The NMC sequence of FWA-6510 6MNC Version 1. NAEM-0103 LAN Bypass description LAN Bypass Pair 1: LAN1 & LAN2 @ NMC Slot LAN Bypass Pair 2: LAN3 & LAN4 @ NMC Slot 2. NAEM-0103 LAN LED status definition: Speed LED: LED indication Description Green Amber Off: Connect to 1 Gbps network Connect to 100 Mbps network Connect to 10 Mbps network or network disconnected
Version: V1.0 Page 8 of 41 Link/Active LED: LED indication Green Green blinking Amber Amber blinking Description Network Connected Active mode LAN Bypass mode LAN Disconnect mode 1.4.2 IPMI LAN Bypass setting 1. NMC Slot Switch Command NMC Slot Switch Command #ipmitool i2c bus=1 0xAA 0xBB 0xCC 0xDD 0xEE 0xAA 0xBB 0xCC 0xDD Description 1 0xe2 0x00 0x00 0x01 Switch to NMC Slot#1 2 0xe2 0x00 0x00 0x02 Switch to NMC Slot#2 3 0xe2 0x00 0x00 0x04 Switch to NMC Slot#3 4 0xe2 0x00 0x00 0x08 Switch to NMC Slot#4 5 0xe2 0x00 0x00 0x10 Switch to NMC Slot#5; only for 6 NMC version 6 0xe2 0x00 0x00 0x20 Switch to NMC Slot#6; only for 6 NMC version 7 0xe2 0x00 0x00 0x40 Switch to NMC Slot#7; only for 8 NMC version 8 0xe2 0x00 0x00 0x80 Switch to NMC Slot#8; only for 8 NMC version 1. Example for NMC Slot Switch Command 1. Switch to NMC Slot#1 Command: #ipmitool i2c bus=1 0xe2 0x00 0x00 0x01 2. Switch to NMC Slot#4 Command: #ipmitool i2c bus=1 0xe2 0x00 0x00 0x08
Version: V1.0 Page 9 of 41 2. LAN Bypass on/lan Direct-connect/LAN Disconnect command #ipmitool i2c bus=1 0xAA 0xBB 0xCC 0xDD 0xEE 0xAA 0xBB 0xCC 0xDD Description 1 0x4c 0x00 0x01 0xXX LAN bypass value Value (0xDD) Power on Description Power off description 0X00 P1 & P2 LAN bypass Off P1 & P2 disconnect 0x55 P1 LAN bypass On & P2 LAN bypass Off P1 & P2 LAN bypass 0x33 P1 LAN bypass Off & P2 LAN bypass On P1 & P2 LAN bypass 0x77 P1 & P2 LAN bypass Off P1 & P2 LAN bypass 0x11 P1 & P2 LAN bypass ON P1 & P2 LAN bypass 0x22 P1 & P2 LAN bypass Off P1 & P2 disconnect 0x44 P1 & P2 LAN bypass Off P1 & P2 disconnect 0x66 P1 & P2 LAN bypass Off P1 & P2 disconnect Example for NMC-0103 LAN bypass: 1. Set NMC Slot#4 NAEM-0103 as P1 & P2 LAN bypass ON #ipmitool i2c bus=1 0xe2 0x00 0x00 0x08 switch to NMC Slot#4 #ipmitool i2c bus=1 0x4c 0x00 0x03 0x00 initial NAEM-0103 #ipmitool i2c bus=1 0x4c 0x00 0x01 0x11
Version: V1.0 Page 10 of 41 2. Set NMC Slot#3 NAEM-0103 as P1 LAN bypass Off & P2 LAN bypass On #ipmitool i2c bus=1 0xe2 0x00 0x00 0x04 switch to NMC Slot#3 #ipmitool i2c bus=1 0x4c 0x00 0x03 0x00 initial NAEM-0103 #ipmitool i2c bus=1 0x4c 0x00 0x01 0x33 3. Set NMC Slot#2 NAEM-0103 as P1 LAN bypass On & P2 LAN bypass Off #ipmitool i2c bus=1 0xe2 0x00 0x00 0x02 switch to NMC Slot#2 #ipmitool i2c bus=1 0x4c 0x00 0x03 0x00 initial NAEM-0103 #ipmitool i2c bus=1 0x4c 0x00 0x01 0x55 4. Set NMC Slot#4 NAEM-0103 as P1 & P2 LAN bypass Off #ipmitool i2c bus=1 0xe2 0x00 0x00 0x08 switch to NMC Slot#4 #ipmitool i2c bus=1 0x4c 0x00 0x03 0x00 initial NAEM-0103 #ipmitool i2c bus=1 0x4c 0x00 0x01 0x77
Version: V1.0 Page 11 of 41 3. NAEM-0103 doesn t have a EEPOM to record last status, please don t set Bypass setting as Keep Card Last Status, otherwise, NAEM-0103 will sets LAN bypass off when FWA-6510 power up
Version: V1.0 Page 12 of 41 1.5 IPMI LAN Bypass control for NMC-0107/0803 LAN module: 1.5.1 Hardware description The NMC slot s PCI-e buses of FWA-6510 are control by Xeon CPU. CPU 1 is control NMC slot 1/2 & 5/6 (only for 6NMC). CPU 2 is control NMC slot 3/4 & 7/8 (only for 8NMC). If customer needs using all NMC slot, please install dual CPU in FWA-6510 FWA-6510 is using a 8-channel I2C bus switch chip to redirect the SM-Bus from motherboard to NMC card by middle board, the I/O address of 8-channel I2C bus switch chip is E2. The Switch sequence is from right to left, and from down to up The NMC sequence of FWA-6510 4MNC Version
Version: V1.0 Page 13 of 41 The NMC sequence of FWA-6510 6MNC Version The I/O address of NMC card s LAN bypass control chip is 4C/4D, LAN bypass pair sequence is from left to right, and from down to up NMC-0803 LAN by-pass pairs NMC-0107 LAN by-pass pair
Version: V1.0 Page 14 of 41 1. NMC-0107/0803 LAN LED status definition: Speed LED: LED indication Description Green Amber Off: Connect to 1 Gbps network Connect to 100 Mbps network Connect to 10 Mbps network or network disconnected Link/Active LED: LED indication Green Green blinking Amber Amber blinking Off: Description Network Connected Active mode LAN Bypass mode LAN Disconnect mode ( Power ON) LAN Disconnect mode ( Power OFF) or network disconnected 1.5.2 IPMI LAN Bypass setting 2. NMC Slot Switch Command #ipmitool i2c bus=1 0xAA 0xBB 0xCC 0xDD 0xEE 0xAA 0xBB 0xCC 0xDD Description 1 0xe2 0x00 0x00 0x01 Switch to NMC Slot#1 2 0xe2 0x00 0x00 0x02 Switch to NMC Slot#2 3 0xe2 0x00 0x00 0x04 Switch to NMC Slot#3 4 0xe2 0x00 0x00 0x08 Switch to NMC Slot#4 5 0xe2 0x00 0x00 0x10 Switch to NMC Slot#5; only for 6 NMC version 6 0xe2 0x00 0x00 0x20 Switch to NMC Slot#6; only for 6 NMC version 7 0xe2 0x00 0x00 0x40 Switch to NMC Slot#7; only for 8 NMC version 8 0xe2 0x00 0x00 0x80 Switch to NMC Slot#8; only for 8 NMC version
Version: V1.0 Page 15 of 41 Example for NMC Slot Switch Command 1. Switch to NMC Slot#1 Command: #ipmitool i2c bus=1 0xe2 0x00 0x00 0x01 2. Switch to NMC Slot#2 Command: #ipmitool i2c bus=1 0xe2 0x00 0x00 0x02 2. LAN Bypass on/lan Direct-connect/LAN Disconnect command #ipmitool i2c bus=1 0xAA 0xBB 0xCC 0xDD 0xEE 0xAA 0xBB 0xCC 0xDD Description 1 0x4c 0x00 0x10 0xXX Control LAN pair 1 (LAN1/LAN2), 0xXX(LAN bypass value) 2 0x4c 0x00 0x20 0xXX Control LAN pair 2 (LAN3/LAN4), 0xXX(LAN bypass value) 3 0x4c 0x00 0x30 0xXX Control LAN pair 3 (LAN5/LAN6), 0xXX(LAN bypass value);only for NMC-0803 4 0x4c 0x00 0x40 0xXX Control LAN pair 4 (LAN7/LAN8), 0xXX(LAN bypass value);only for NMC-0803 NMC-0107/0803 LAN bypass Value table: Value 0x81 0x82 0x83 0x84 Description power on direct-connect/power off disconnect power on disconnect/power off disconnect power on direct-connect/ power off bypass power on bypass/ power off bypass
Version: V1.0 Page 16 of 41 Example for LAN Bypass on/lan Direct-connect/LAN Disconnect command 1. Set NMC Slot#1 LAN pair 1(LAN1/LAN2) as power on direct-connect/power off disconnect #ipmitool i2c bus=1 0xe2 0x00 0x00 0x01 switch to NMC Slot#1 #ipmitool i2c bus=1 0x4c 0x00 0x10 0x81 0x00 2. Set NMC Slot#2 LAN pair 2(LAN3/LAN4) as power on disconnect/power off disconnect #ipmitool i2c bus=1 0xe2 0x00 0x00 0x02 switch to NMC Slot#2 #ipmitool i2c bus=1 0x4c 0x00 0x20 0x82 0x00 3. Set NMC Slot#2 LAN pair 3(LAN5/LAN6; only for NMC-0803) as power on direct-connect/ power off bypass #ipmitool i2c bus=1 0xe2 0x00 0x00 0x01 switch to NMC Slot#1 #ipmitool i2c bus=1 0x4c 0x00 0x30 0x83 0x00 4. Set NMC Slot#1 LAN pair 4(LAN7/LAN8, only for NMC-0803 ) as power on bypass/ power off bypass #ipmitool i2c bus=1 0xe2 0x00 0x00 0x02 switch to NMC Slot#2 #ipmitool i2c bus=1 0x4c 0x00 0x40 0x84 0x00
Version: V1.0 Page 17 of 41 3. IPMI WDT LAN Bypass setting #ipmitool i2c bus=1 0xAA 0xBB 0xCC 0xDD 0xEE 0xAA 0xBB 0xCC 0xDD Description 1 0x4c 0x00 0x10 0xXX Control LAN pair 1 (LAN1/LAN2), 0xXX(LAN bypass value) 2 0x4c 0x00 0x20 0xXX Control LAN pair 2 (LAN3/LAN4), 0xXX(LAN bypass value) 3 0x4c 0x00 0x30 0xXX Control LAN pair 3 (LAN5/LAN6), 0xXX(LAN bypass value) 4 0x4c 0x00 0x40 0xXX Control LAN pair 4 (LAN7/LAN8), 0xXX(LAN bypass value) NMC-0107/0803 LAN Bypass Value Value 0x85 0x86 0x87 Description Timer mode: power on direct-connect Timeout Bypass / power off Bypass Timer mode: power on Bypass Timeout direct-connect / power off Bypass Timer mode: power on disconnect Timeout direct-connect / power off disconnect #ipmitool i2c bus=1 0xAA 0xBB 0xCC 0xDD 0xEE 0xAA 0xBB 0xCC 0xDD 0xEE Description 2 0x4c 0x00 0x12 0xXX 0xXX WDT Port 1 (LAN1/LAN2), 0xXX(WDT time value) 4 0x4c 0x00 0x22 0xXX 0xXX WDT Port 2 (LAN3/LAN4), 0xXX(WDT time value) 6 0x4c 0x00 0x32 0xXX 0xXX WDT Port 3 (LAN5/LAN6), 0xXX(WDT time value) 8 0x4c 0x00 0x42 0xXX 0xXX WDT Port 4 (LAN7/LAN8), 0xXX(WDT time value) 8 0x4c 0x00 0x50 0x00 0x00 Reload P1/P2/P3/P4 WDT NMC-0107/0803 WDT Time Vale Value 0X00 0X01~0xFF 0XFF Description Time unit is 0.1sec (0.1~6553.5 sec)
Version: V1.0 Page 18 of 41 Example for IPMI WDT LAN Bypass setting 1. Set NMC Slot#1 LAN pair 1(LAN1/LAN2) as WDT Timer mode: power on direct-connect Timeout Bypass / power off Bypass #ipmitool i2c bus=1 0xe2 0x00 0x00 0x01 switch to NMC Slot#1 #ipmitool i2c bus=1 0x4c 0x00 0x12 0x00 0x30 set WDT timer as 30H (4.8 sec) #ipmitool i2c bus=1 0x4c 0x00 0x10 0x85 0x00 2. Set NMC Slot#2 LAN pair 2(LAN3/LAN4) as WDT Timer mode: power on Bypass Timeout direct-connect / power off Bypass #ipmitool i2c bus=1 0xe2 0x00 0x00 0x02 switch to NMC Slot#2 #ipmitool i2c bus=1 0x4c 0x00 0x22 0x00 0x60 set WDT timer as 60H(9.6 sec) #ipmitool i2c bus=1 0x4c 0x00 0x20 0x86 0x00 3. Set NMC Slot#3 LAN pair 3(LAN5/LAN6) as WDT Timer mode: power on disconnect Timeout direct-connect / power off disconnect #ipmitool i2c bus=1 0xe2 0x00 0x00 0x04 switch to NMC Slot#3 #ipmitool i2c bus=1 0x4c 0x00 0x32 0x00 0x90 set WDT timer as 90H(14.4 sec) #ipmitool i2c bus=1 0x4c 0x00 0x30 0x87 0x00 PS: LAN pair 3(LAN5/LAN6) is only for NMC-0803
Version: V1.0 Page 19 of 41 4. Reload NMC Slot#1 all LAN bypass setting #ipmitool i2c bus=1 0xe2 0x00 0x00 0x01 switch to NMC Slot#1 #ipmitool i2c bus=1 0x4c 0x00 0x50 Reload P1/P2/P3/P4 WDT of NMC Slot#1
Version: V1.0 Page 20 of 41 2. FWA-6510 IPMI WDT SYSTEM REBOOT SETTING FWA-6510 WDT system reboot is using BMC watchdog function; it needs following IPMI command form to set, enable & disable BMC watchdog. 1. IPMI WDT command Ipmitool mc watchdog <command>: command get reset off description Get Current Watchdog settings Restart Watchdog timer based on most recent settings Shut off a running Watchdog timer 2. Set BMC watchdog timer setting Command: ipmitool raw 0x06 0x24 0x01 0x01 0x00 0x00 0xAA 0xBB Value description 0xAA WDT reset value low byte 0xBB WDT reset value high byte Timer range 0.1~6553.5 second Example 1. When user needs set WDT timer as 60.0 sec, it needs to translate from Decimal to hexadecimal first 600(dec)=0258(hex) Command is ipmitool raw 0x06 0x24 0x01 0x01 0x00 0x00 0x58 0x02
Version: V1.0 Page 21 of 41 2. Please key-in ipmitool mc watchdog get to check watchdog status, the Initial countdown set as 60 sec. 3. Please key-in ipmitool mc watchdog reset, BMC watchdog reset is count downing, user may get watchdog status to check status, When Present Countdown is countdown to 0, FWA-6510 system will auto execute system reboot. 4. Please key-in ipmitool mc watchdog reset again; BMC watchdog reboot is re-countdown,
Version: V1.0 Page 22 of 41 5. When user needs to disable BMC watchdog reboot function, please key-in ipmitool mc watchdog off, but watchdog timer will force to set default value (300sec), user needs to set watchdog timer again
Version: V1.0 Page 23 of 41 3. FWA-6510 GPIO CONTROL SETTING FWA-6510 CN10 is a GPIO connector, user may refer CN10 pin definition and command table to control FWA-6510 GPIO function. 1. CN10 Pin definition
Version: V1.0 Page 24 of 41 2. GPIO Pin command. #ipmitool i2c bus=1 0xAA 0xBB 0xCC 0xDD 0xEE 0xAA 0xBB 0xCC 0xDD Description 1 0x46 0x00 0x03 0x00 Set GPIO mode as output mode #ipmitool i2c bus=1 0xAA 0xBB 0xCC 0xDD 0xEE 0xAA 0xBB 0xCC 0xDD Description 1 0x46 0x00 0x01 0x01 Set GPIO pin0 as high 2 0x46 0x00 0x01 0x02 Set GPIO pin1 as high 3 0x46 0x00 0x01 0x04 Set GPIO pin2 as high 4 0x46 0x00 0x01 0x08 Set GPIO pin3 as high 5 0x46 0x00 0x01 0x10 Set GPIO pin4 as high 6 0x46 0x00 0x01 0x20 Set GPIO pin5 as high 7 0x46 0x00 0x01 0x40 Set GPIO pin6 as high 8 0x46 0x00 0x01 0x80 Set GPIO pin7 as high Example: Set GPIO Pin0 status as high # ipmitool i2c bus=1 0x46 0x00 0x03 0x00 # ipmitool i2c bus=1 0x46 0x00 0x01 0x01 Set GPIO pin6 status as high # ipmitool i2c bus=1 0x46 0x00 0x03 0x00 # ipmitool i2c bus=1 0x46 0x00 0x01 0x40
Version: V1.0 Page 25 of 41 4. FWA-6510 GRAPHIC LCM UTILITY FWA-6510 LCM is a CW12832 Graphical Serial LCD Module, It default connects to FWA-6510 COM2 (/dev/ttys1), kindly refer Advantech LCM sample code to make program for customer used, or refer lcd4linux (http://ssl.bulix.org/projects/lcd4linux/ ) open source code. Below step is using Advantech LCM utility to demo FWA-6510 LCM function 1. Kindly copy FWA-6510 LCM utility(lcm_v1.1.tar.gz) into FWA-6510 Linux system and uncompress it 2. Kindly into lcm/trunk and key-in make command to make a execute file, CW_print
Version: V1.0 Page 26 of 41 3. Please refer README to execute FWA-6510 graphic LCM self-test, the self-test has 5 test itesms 3.1 kindly key-in sh LCM_check.sh "/dev/ttys1" Utility will show below message LCM will show Advantech logo and LCM test message 3.2 The item is LCM keypad test, kindly follow utility message pressing LCM keypad to test keypad function. 3.3 The item is LCD pixel test; kindly check LCD display and LCD will shows all light-white If LCD test is OK, kindly follow utility message to press middle key, if not, please press other key, utility will show test fail message and go to next test.
Version: V1.0 Page 27 of 41 Next test, LCD will shows all back-light If LCD test is OK, kindly follow utility message to press middle key, if not, please press other key, utility will show test fail message and go to next test. 3.4. The item is LCD pixel test, kindly check LCM display and LCD will show 1~9, a~z & A~Z characters. If LCD test is OK, kindly follow utility message to press middle key, if not, please press other key, utility will show test fail message and go to next test. 3.5 The item is LCD backlight test, it will test LCM backlight from level 0x01 to 0x07 If LCD test is OK, kindly follow utility message to press middle key, if not, please press other key, utility will show test fail message and go to next test.
Version: V1.0 Page 28 of 41 3.6 The item is LCD contrast test, it tests LCD s contrast from level 0x00 to 0x1c If LCD test is OK, kindly follow utility message to press middle key, if not, please press other key, utility will show test fail message and go to next test. 3.7 If all tests are OK, Utility will show LCM_check.sh pass If not, Utility will show LCM_check.sh fail
Version: V1.0 Page 29 of 41 4. FWA-6510 LCM utility is CW_print, user may follow below command to control LCM function
Version: V1.0 Page 30 of 41 Example: Lets LCD display showing the string for user defined; user may refer below command to control LCM function.
Version: V1.0 Page 31 of 41 5. FWA-6510 BMC FIRMWARE UPGRADE If user needs to upgrade FWA-6510 BMC Firmware, please use SSH-terminal to execute remote upgrade BMC F/M, please don t use console redirection (COM1) or IPMI SOL to upgrade FWA-6510 F/M, otherwise, user is unable to finish BMC Firmware process. Blow steps are using SSH-terminal to upgrade FWA-6510 BMC F/M. 1. Please open chassis to look MAC barcode of BMC, or key-in ipmitool lan print to and record BMC MAC, LAN IP address & submask
Version: V1.0 Page 32 of 41 2. Kindly refer blow photo to use AMI flash tool(yafukcs) flashing BMC firmware, and please press Y to agree F/M upgrading process. 3. When user press Y, it will auto execute F/M process, and all process needs waiting 10 min
Version: V1.0 Page 33 of 41 4. When BMC F/M upgrades finish, BMC s IP address, Subnet mask and MAC address will force as 0, 5. Please key-in below commands to re-set BMC MAC address, IP address and Subnet mask A1. Please key-in below command to get number enabling BMC NIC1 # ipmitool raw 0x0c 0x02 0x01 0xc2 0x00 0x00 # ipmitool raw 0x0c 0x01 0x01 0xc2 0x00 A2.Please key-in below command to set MAC address of BMC NIC1, the last 6 characters needs to follow BMC MAC barcode(ex: 00:D0:C9:B3:01:4B), #ipmitool raw 0x0c 0x01 0x01 0x05 0x00 0xd0 0xc9 0xB3 0x01 0x4b
Version: V1.0 Page 34 of 41 A3: Please key-in ipmitool lan print to double check BMC MAC address. B1. The BMC IP needs following recorded IP address and subnet address (Static IP address), or set BMC IP address as DHCP, Below step is setting BMC IP as Static MAC IP address & subnet mask Ex: # ipmitool lan set 1 ipaddr 192.168.0.254 #ipmitool lan set 1 netmask 255.255.255.0 And key-in ipmitool mc reset cold to reset BMC F/M.
Version: V1.0 Page 35 of 41 B2. Please key-in ipmitool lan print to double check BMC IP & Subnet addresses. And user may use Web Browsers to connect FWA-6510 BMC.
Version: V1.0 Page 36 of 41 6. FWA-6510 IKVM OPERATION 1. Key in the BMC IP address in web Brower, it needs to use ipmitool command setting BMC IP first. 2. Enter the username and password. (Default: username: admin; password: admin) 3. Interface of IKVM
Version: V1.0 Page 37 of 41 4. Click on Remote control and click the console redirection 5. Start java console by ikvm Note1: The mouse cursor on the java console cannot pinpoint on monitor which connect VGA directly. Note2: IKVM would have the problem as below shows, when boot into the System Administrator first time. It might be related with VGA chip.
Version: V1.0 Page 38 of 41 7. BIOS FUNCTION SETTING 7.1 BIOS power status setting The power control item of FWA-6510 BIOS is BMC POWER POLICY, the item is in Chipset South Bridge BMC POWER POLICY. BMC POWER POLICY only sets by BMC; it is unable to change setting by BIOS Kindly use ipmitool command to change Power Policy of FWA-6510 Command form is
Version: V1.0 Page 39 of 41 Example: If customer needs to set BIOS/BMC POWER POLICY as always off, kindly key-in command ipmitool chassis policy always-off The BMC POWER POLICY will change from power on to Power off
Version: V1.0 Page 40 of 41 7.2 BIOS LAN Bypass setting Customer may use BIOS to set LAN bypass status of NMC LAN module, please choose Chipset FWA-6510 Setting Bypass setting The default setting of Bypass setting item is Keep card Last States, It means BIOS doesn t force controlling LAN bypass status of NMC LAN module. Customer may choose Modify card bypass to let BIOS to control NMC LAN module s bypass status.
Version: V1.0 Page 41 of 41 When user chooses Modify card bypass, it will show 8 items. The items of SLOT1 LAN bypass ~ SLOT4 LAN bypass are only for FWA-6510 4 NMC version. The items of SLOT1 LAN bypass ~ SLOT6 LAN bypass are only for FWA-6510 6 NMC version. The items of SLOT1 LAN bypass ~ SLOT8 LAN bypass are only for FWA-6510 8 NMC version. Each items have two options, kindly refer below option description, these options will let NMC LAN module s all LAN pair as enable/disable/disconnect bypass function of the Slot No Bypass: : power on direct-connect/power off disconnect Bypass When DC/AC ON: power on bypass /power off bypass