Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014

Similar documents

Service & Support. How can you transfer a WinCC (TIA Portal) project to an operator panel using Ethernet? WinCC (TIA Portal) FAQ February 2012

How can you display error messages and warnings of a frequency converter on a panel? WinCC flexible RT and Panels FAQ

FAQ about Drive Technology

FAQ Communication over PROFIBUS

Connecting a PC Station to an S using OPC

FAQ 03/2014. How do I go online? SIMOTION & SINAMICS.

Quick Start Guide NETL ink Ethernet Gateways

Service & Support. Data Communication between S7 Station and PC Station, using SIMATIC NET OPC Server SIMATIC S7. Function description March 2013

Tech Note 220 Configuring the S7 Server for MPI or Profibus Communications for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP5613 Card

Communication between HMI and Frequency Converter. Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120. Application Example 04/2016


Service & Support. How do you create a communication of with an Industrial Thin Client SIMATIC ITC? Thin Client.

Document: S7 Driver Configuration. Setting up the S7 driver to communicate with Siemens Hardware (S7-300/400 Series) using CP

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

FAQ Communication over IE

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SIMATIC. S7 and Profibus- DP Configuration Guide G1026

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Commissioning PC Stations - Manual. and Quick Start SIMATIC NET. PC software Commissioning PC Stations - Manual and Quick Start.

LB/FB8X09* / LB/FB8X05*

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

Sample project Filling Station SIMATIC. STEP 7 Professional / WinCC Advanced V11 for Sample project Filling Station. Overview of the Getting.

FAQ about communication via IE

TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS

Exchange of large data volumes between S control system and WinCC

FAQ Communication over PROFIBUS

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE D3

Display of SINAMICS Fault Messages in WinCC V7.4


Service & Support. MODBUS/TCP Communication over Integrated PROFINET Interface of S7-300 and S7-400 CPU. Modbus/TCP PN CPU.

Applications & Tools. Service Concept: Auto Backup for the Comfort Panels. WinCC (TIA Portal) V12. Application Description May 2013

How Do You Replace a CPU 41x with the CPU 410-5H Process Automation? SIMATIC PCS 7 FAQ 01/2016

efesotomasyon.com - Klockner Moeller - inverter Application Note Simatic S7 Siemens AG 2005, all rights reserved

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information


1 What's new in SIMATIC imap STEP 7 AddOn?

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE D5

PAS 300, PROFIBUS Slave Interface Module

SITRAIN. Introduction TIA Portal. Siemens AG All rights reserved. Unrestricted

Cover. Configuration of an IM 308-C as DP Slave to a CP as DP Master PROFIBUS DP. FAQ July Service & Support. Answers for industry.

I-Device Function in Standard PN Communication SIMATIC S7-CPU, CP, SIMOTION, SINUMERIK. Configuration Example 08/2015

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

SIMATIC. Windows Automation Center WinAC Basis V4.1. User Manual. Version: 05/2004 A5E Siemens Automation

TS8000. Profibus DP Slave Configuration Application Note TS8922U001

View the most recent product information online

IO-Link What is it? 2

SIMATIC NET. S7 CPs for Industrial Ethernet CP Version 3 or later (Firmware version V2.2) for SIMATIC S LED displays.

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

SINUMERIK Integrate Create MyHMI / WinCC V13 SP1 SINUMERIK. SINUMERIK 840D sl SINUMERIK Integrate Create MyHMI / WinCC V13 SP1. Preface.

s Preface SIMATIC Configuring Hardware and Communication Connections with STEP 7 Contents Basics of Configuring Hardware with STEP 7 1

SIMATIC. Configuring Hardware and Communication Connections STEP 7. Basics of Configuring Hardware with STEP 7. Configuring Central Racks 2

Siemens Distributor SIMATIC. WinAC MP for MP370 V3.1. Preface, Contents. Product Overview. Transferring WinAC MP to the Multi Panel

Display of SINAMICS Error Messages in Runtime Professional

IE/PB LINK PN IO. PROFINET applications

Usability Improvement SIMATIC NET PC CD 11/2003

Drive System Application

Notes on Installation and Use

Application about Drive Technology

Operating system update with ProSave. ProSave. FAQ July Service & Support. Answers for industry.

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E09. PROFINET with 2x CPU 315F-2 PN/DP

Service & Support. Replacing the Parent Hardware Module with the Successor Hardware Module (Migration) CP443-1 (Advanced) FAQ July 2012

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

Applications & Tools. Time-of-Day Synchronization between WinCC Runtime Professional and S7 Controllers. WinCC Runtime Professional

SIMATIC NET. S7-CPs for PROFIBUS Configuring and Commissioning

WinAC RTX 2010 Getting Started. Getting-started. Edition ( )

Application for Process Automation

Service & Support. Which options exist for reading hardware limit switch signals into a technology CPU? Technology CPU.

TECHNICAL NOTE TNOI30

SIMATIC. Configuring Hardware and Communication Connections STEP 7. Preface Basics of Configuring Hardware with STEP 7 1

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

SIMATIC. Windows Automation Center. WinAC Basis. Overview. Preface. Product Overview 1. Installing the Components of. WinAC Basis

Service & Support. How do I configure extended PROFIsafe on the CU240E-2?

Information About the Getting Started PCS 7 - First Steps Documentation

SIMATIC. Windows Automation Center RTX WinAC RTX V4.0. User Manual A5E

How do you encrypt the connection between SIMATIC Logon and a Comfort Panel or a WinCC Runtime Advanced?


SIMATIC PCS 7 Minimal Configuration

SIMATIC S7-PLCSIM Advanced V1.0. Simulation with TIA Portal V14 and PLCSIM Advanced

SIMATIC. Windows Logic Controller (WinLC) Preface, Contents. Product Overview 1. Setting Up WinLC Software 2

Configuration Control with the S and ET 200SP

SIMATIC. Configuring Hardware and Communication Connections STEP 7 V5.2. Preface, Contents Basics of Configuring Hardware with STEP 7

Applications & Tools. Individual Access to Stored PDF- and HTML-Documents via Comfort Panel. WinCC Comfort V11. Application Description May 2012

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA)

Notes on Installation and Use

FAQ Kommunikation over PROFIBUS

SIMATIC. Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS S120. Introduction. Preparation 2. Learning units 3. Further Information 4

Accessing SINAMICS parameters via OPC server

Introduction to the TIA Portal V13, S7-1500, and Startdrive

SIMATIC. PDM V5.2 The Process Device Manager. Preface, Contents. Product Introduction 1. Starting SIMATIC PDM 2 Configuring Networks and Devices 3

1 What's new in SIMATIC imap STEP 7 AddOn?

Cover sheet. Communication between SIMATIC S5 and SIMATIC S7 over PROFIBUS. FDL protocol. FAQ February Service & Support. Answers for industry.

Process Control System PCS 7 V7.0. Getting Started First Steps Documentation November 2006

SINAMICS G120/G120D/G120C/G120P/G110M

Applications & Tools. Failsafe and standard cross communication of the MSS 3RK3 via AS-Interface. SIRIUS Safety. FAQ February 2012

TIA Portal V11 Exercises

Transcription:

FAQ 03/2014 Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - http://support.automation.siemens.com/ww/view/en/88633853

This entry is from the Siemens Industry Online Support. The general terms of use (http://www.siemens.com/terms_of_use) apply. Caution The functions and solutions described in this entry are predominantly limited to the realization of the automation task. When linking your system to other system components, to the company network or to the internet, appropriate industrial security measures must be taken. More information about this is available in Entry ID:!50203404!. http://support.automation.siemens.com/ww/view/en/50203404 Contents 1 General... 3 1.1 Contents... 3 1.2 Settings... 3 1.2.1 Settings on the Panel... 3 1.2.2 Settings on the Configuration PC... 5 2 Basic Check... 9 2.1 General Settings... 9 2.1.1 Settings on the panel... 9 2.1.2 Settings on the PC... 11 2.1.3 PROFIBUS male bus connectors... 13 2.1.4 Repeater... 13 2.1.5 Cable Connections... 14 3 Detailed Check... 15 3.1 PC Settings... 15 3.1.1 Check the Interface... 15 3.1.2 Network Diagnostics: Display Accessible Devices... 17 3.2 HMI Configuration... 20 3.2.1 Check the PROFIBUS Settings... 20 3.2.2 Check the Transfer Settings... 21 3.3 Operator Panel Settings... 23 3.3.1 Transfer Settings in the Control Panel... 23 3.3.2 Network Settings on the Operator Panel... 24 4 Tips for Configuring and Commissioning... 25 5 Link List... 26 Entry ID: 88633853, V1.0, 03/2014 2

1 General 1 General 1.1 Contents This entry describes different solutions if you should encounter problems when transferring the configuration file to the HMI operator panel. Possible causes are listed and remedies given for clearing them. Requirement Transfer of the HMI configuration to the operator panel is by PROFIBUS or MPI. Note The document describes troubleshooting using PROFIBUS. The procedure using MPI is done in the same way. 1.2 Settings You must open different menus to check the settings. This chapter describes how to get to the menus and settings. In later error analyses we refer to this chapter. 1.2.1 Settings on the Panel Set the panel to the Transfer mode Table 1-1 1. After the panel has started up or after the panel Runtime has been completed, the "Loader" menu is displayed. Select the "Transfer" button in the "Loader" menu. Entry ID: 88633853, V1.0, 03/2014 3

1 General Make Transfer settings on the panel Table 1-2 1. Select the "Control Panel" button in the "Loader" menu. In the "Control Panel" you select the "Transfer" icon. The "Transfer Settings" window opens. Change bus parameters on the panel Table 1-3 1. Select the "Control Panel" button in the "Loader" menu. In the "Control Panel" you select the "Transfer" icon. Select the "Channel" tab. Select "PROFIBUS" from the list. Click the "Properties..." button. Entry ID: 88633853, V1.0, 03/2014 4

1 General 1.2.2 Settings on the Configuration PC Settings of the PG/PC interface (WinCC flexible 2008) Table 1-4 1. Click the Windows "Start" button and open the Control Panel. Select the "Set PG/PC interface " item. In the "Set PG/PC interface" dialog you select the interface parameter assignment and access point. Click "Properties..." to set the properties of the CPs. 2. You specify the properties of the CP in the window. Entry ID: 88633853, V1.0, 03/2014 5

1 General Parameterize the MPI/PROFIBUS interface (WinCC (TIA Portal)) Table 1-5 1. In the project tree, the "Online access" folder gives you all the enabled interfaces of the PG/PC. Right-click the CP you are using. Select the "Properties..." command in the pop-up menu. The "Properties" dialog opens. The area navigation is on the left. Select and change the relevant parameters as required. Notes Make sure that the bus settings are identical to those of the configured and connected PROFIBUS. Details on the parameters are available in the Online Help. Entry ID: 88633853, V1.0, 03/2014 6

1 General Network settings in the HMI configuration Table 1-6 1. Open the Device Configuration of the HMI operator panel. Enable Network View. Mark the PROFIBUS segment with the mouse. You can make different network settings under "Properties > General > Network settings". Entry ID: 88633853, V1.0, 03/2014 7

1 General Transfer settings in the HMI configuration Table 1-7 1. In the project tree you open the folder of the operator panel to be transferred. Select the menu command "Online > Extended download to device...". The window (Extended download) with the transfer settings opens. Entry ID: 88633853, V1.0, 03/2014 8

2 Basic Check 2 Basic Check This chapter describes the most common sources of error. If you cannot now transfer the configuration to the HMI operator panel, then you must run a detailed check. Refer here to chapter 3. 2.1 General Settings Check the PROFIBUS address Check the PROFIBUS address and associated network parameters On the panel (for details about calling functions see 1.2.1). On the configuration PC (for details about calling functions see 1.2.2). In the HMI configuration (for details about calling functions see 1.2.2). Network parameters to be checked Address Transmission rate Highest station address Profile 2.1.1 Settings on the panel Table 2-1 1. Panel in Transfer mode Set the panel to Transfer mode. Note Also set the panel to Transfer mode even if you have chosen the "Enable automatic transfer" (Remote Control) option in the transfer settings on the panel. Entry ID: 88633853, V1.0, 03/2014 9

2 Basic Check 2. Settings for the transfer and bus parameters (Comfort Panel) Compare the settings made here with the transfer settings in the HMI configuration. Check the PROFIBUS network installation. Make sure that the "Enable Transfer" option is enabled. Entry ID: 88633853, V1.0, 03/2014 10

2 Basic Check 2.1.2 Settings on the PC Table 2-2 1. Network settings in the HMI configuration Check the network settings in the HMI configuration. They must be identical to the settings made on the panel. 2. Change/check the PROFIBUS address in the HMI configuration Check the PROFIBUS address. They must be identical to the settings made on the panel. Entry ID: 88633853, V1.0, 03/2014 11

2 Basic Check 3. Transfer settings Compare the transfer settings with those made on the operator panel. 4. PG/PC interface (WinCC flexible 2008) Check the settings of the PG/PC interface (only necessary when using WinCC flexible). Entry ID: 88633853, V1.0, 03/2014 12

2 Basic Check 2.1.3 PROFIBUS male bus connectors Check the PROFIBUS male bus connectors for the following points. Figure 2-1 bus terminal resistor outgoing line incoming line Switch position of the bus terminating resistor. ON: The switch position must be "ON" (terminator activated) on the PROFIBUS for the first and last station (activated terminator). There is only one incoming line on the connector. OFF: The switch position must "OFF" (terminator deactivated) on the PROFIBUS for all the other stations. There is an incoming and an outgoing line on the connector. Incoming cables are always connected on the left (see coding A1, B1). Incoming cables are always connected on the left (see coding A1, B2). Check the cable connections as necessary. Make sure that the connectors are wired in properly. Incoming line and outgoing line mixed up. Incorrect connection (green/red mixed up). Defective shielding. 2.1.4 Repeater Check the network topology. Is the HMI operator panel connected after a repeater in the network? Make sure that the repeater power supply is switched on. Entry ID: 88633853, V1.0, 03/2014 13

2 Basic Check 2.1.5 Cable Connections PROFIBUS cable Cable connections between the operator panel, the PC and other PROFIBUS stations. Always use an original PROFIBUS cable. Figure 2-2 MPI cable PC Adapter USB Network structure Always use an original PROFIBUS cable also in MPI networks and for transferring the configuration. Note that the "PC Adapter USB" is not released for all operator panels. More information about this is available in the FAQ response in Entry ID 19109408. Wire the PROFIBUS stations as shown in the figure below. Pay attention here to the switch position of the bus terminating resistor (for this see section 2.1.3). Figure 2-3 Entry ID: 88633853, V1.0, 03/2014 14

3 Detailed Check 3 Detailed Check 3.1 PC Settings 3.1.1 Check the Interface WinCC (TIA Portal) WinCC flexible 2008 Table 3-1 When using WinCC (TIA Portal), there is no need to make any settings in the PG/PC interface for transferring the configuration to the operator panel. All the required settings are made in the "Extended download" menu. To check the properties of the CP used, refer to the description in section 1.2.2. When using WinCC flexible 2008, check the settings in the PG/PC interface. 1. Change the settings of the PG/PC interface In the dialog window you select the CP you are using. In this example "CP5611 PROFIBUS". Under "Access Point of the Application" you select "S7ONLINE (STEP 7) à your CP". Entry ID: 88633853, V1.0, 03/2014 15

3 Detailed Check 2. Change the properties of the PG/PC interface Open the Properties of the selected interface with the "Properties..." button. Enable the option "PG/PC is the only master on the bus". Enter "0" (null) for the "Address". The other parameters must match the transfer settings on the operator panel and the HMI configuration. Click "OK" to confirm the settings. 3. Troubleshooting Note If you cannot change the PG/PC interface, check whether "PLC SIM" or an HMI Runtime is still enabled. PLC SIM disables all other online interfaces. In this case, first close the running application (assuming that this is allowed to be closed). Perform network diagnostics. See section 3.1.2 for this. Entry ID: 88633853, V1.0, 03/2014 16

3 Detailed Check 3.1.2 Network Diagnostics: Display Accessible Devices WinCC (TIA Portal) Table 3-2 1. Online access Open the WinCC (TIA Portal) configuration. Open the "Online access" folder in the project tree. The folder contains all the enabled interfaces of your PG/PC. Open the subfolder of the CP used. In this example "CP5611 PROFIBUS". To update the list you double-click "Update accessible devices". If the panel is accessible in the network, it is listed underneath the interface used. In this example these are the PROFIBUS devices with the addresses "2" (PLC) and "10" (HMI operator panel). Note Detailed information about "Online access" is available in the Online Help. Entry ID: 88633853, V1.0, 03/2014 17

3 Detailed Check 2. Troubleshooting The panel is in the list of accessible devices. If the panel you are using is in the list of accessible devices, check the PROFIBUS addresses of the other devices in the list. There might be a device there with the same PROFIBUS address. Set the panel to Transfer mode. The panel is not in the list of accessible devices. Check the cable connection. See section 2.1.5 for this. Check the PROFIBUS male bus connectors. See section 2.1.3 for this. Check the PROFIBUS settings in the HMI configuration. See section 3.2 for this. Check the PROFIBUS settings on the operator panel. See section 3.3 for this. Network diagnostics: WinCC flexible Table 3-3 1. Call diagnostics (open the PG/PC interface) Call the PG/PC interface. The access point / interface must be set to PROFIBUS. Click the "Diagnostics..." button. The "SIMATIC NET diagnostics" window opens. Entry ID: 88633853, V1.0, 03/2014 18

3 Detailed Check "SIMATIC NET diagnostics" window Perform network diagnostics for the CP by clicking the "Test" button. If the network diagnostics test is "OK", click the "Read" button. The "Bus Nodes" table shows all the recognized PROFIBUS stations. In this example these are the bus nodes with the addresses "0" (PC); "2" (PLC) and "10" (HMI operator panel). 2. Troubleshooting The panel is in the list of accessible devices. If the panel you are using is in the list of accessible devices, check the PROFIBUS addresses of the other devices in the list. There might be a device there with the same PROFIBUS address. Set the panel to Transfer mode. Network diagnostics. If the operating mode is not "OK", check the hardware and the hardware and the bus parameters in the PG/PC interface. If necessary, check the CPU settings in the Hardware Configuration and the settings on the panel. The panel is not in the list of accessible devices. Check the cable connection. See section 2.1.5 for this. Check the PROFIBUS settings in the HMI configuration. See section 3.2 for this. Check the PROFIBUS settings on the operator panel. See section 3.3 for this. Entry ID: 88633853, V1.0, 03/2014 19

3 Detailed Check 3.2 HMI Configuration 3.2.1 Check the PROFIBUS Settings Table 3-4 1. Network view Open the Device View of the operator panel and call the Network View. Mark the PROFIBUS interface of the operator panel and check the parameters entered. 2. Troubleshooting Is the panel in the correct subnet? Do the settings match those on the operator panel? Is there a router in the network? Make sure that the power supply is switched on. Entry ID: 88633853, V1.0, 03/2014 20

3 Detailed Check 3.2.2 Check the Transfer Settings Table 3-5 1. Extended download Check each parameter in the "Extended download" dialog. PG/PC interface type Here you select PROFIBUS. PG/PC interface Select the CP you are using. In this example "CP5611". Connection to subnet Here you select the network in which the panel is located. If the panel is connected directly to the PC, you can also use the "Direct at slot..." setting. Show all compatible devices (option) Select this option if you do not know the address of the operator panel, for example, or you want to have all the network nodes displayed. Note Next to the drop-down list box of the PG/PC interface you can use the "Configure Interface" icon (1) to call the parameters of the CP used. See also section 1.2.2 for this. 1 Entry ID: 88633853, V1.0, 03/2014 21

3 Detailed Check 2. Troubleshooting The panel is in the "Compatible devices in target subnet" table. If the panel you are using is in the list of accessible devices, check the PROFIBUS addresses of the other devices in the list. There might be a device there with the same PROFIBUS address. Set the panel to Transfer mode. The panel is not in the "Compatible devices in target subnet" table. Check the entry for "Type of the PG/PC interface:". Have you selected MPI here? Compare this with the transfer settings on the operator panel. PG/PC interface. Check the settings of the CP used. Refer here to chapter 1.2.2. Enable the "Show all compatible devices" option. The panel is recognized even if a different PROFIBUS address is entered on the panel. Check the cable connection. See section 2.1.5 for this. Check the PROFIBUS settings in the HMI configuration. See section 3.2 for this. Check the PROFIBUS settings on the operator panel. See section 3.3 for this. Entry ID: 88633853, V1.0, 03/2014 22

3 Detailed Check 3.3 Operator Panel Settings 3.3.1 Transfer Settings in the Control Panel Table 3-6 1. Transfer settings Check each setting in the "Transfer Settings" dialog. Enable Transfer This option must be enabled if you want to transfer the configuration to the panel. Remote Control If you disable this option, you have to set the panel manually to Transfer Mode before you can transfer the configuration to the panel. Interface selection Specify the transfer protocol. This setting must be identical to the one in the configuration. 2. Troubleshooting Transfer protocol Have you selected MPI here? This setting must be identical to the transfer settings in the configuration. Properties. Use the "Properties " button to call the network settings. Check the PROFIBUS parameters set there. They must match the parameters used in the HMI configuration. See section 3.3 for this. Entry ID: 88633853, V1.0, 03/2014 23

3 Detailed Check 3.3.2 Network Settings on the Operator Panel Table 3-7 1. PROFIBUS parameters Check the PROFIBUS parameters. Make sure that the PROFIBUS parameters match those in the configuration. 2. Troubleshooting Check the PROFIBUS parameters entered. Check whether the PROFIBUS address has not already been assigned in the network. For this you remove the PROFIBUS cable and have all the accessible devices displayed (see section 3.1.2). Entry ID: 88633853, V1.0, 03/2014 24

4 Tips for Configuring and Commissioning 4 Tips for Configuring and Commissioning Configuration Make a list of all the devices in the network. Note the following information for each device. Device designation PROFIBUS address and the parameters used Compare the list with the devices in the plant. This avoids duplicate assignment of PROFIBUS addresses. Commissioning Before you start testing the network connection to the panel, take a good look at the network structure of the plant. If necessary, get together with a network manager before commissioning. Check the cable connections. Are there repeaters in the network? Are there multiple PROFIBUS networks? Are there already multiple devices/operator panels in the network? Is there a list of the devices already in the network? Are all the devices in the same PROFIBUS network? First make a direct connection with the panel and then try to establish a connection. Only when that works should you connect the panel to the network. Entry ID: 88633853, V1.0, 03/2014 25

5 Link List 5 Link List WinCC (TIA Portal) Table 5-1 Type Link 1. FAQ Which connector cables are available for connecting to SIMATIC Panels? http://support.automation.siemens.com/ww/view/en/19109408 2. FAQ How can you transfer a WinCC (TIA Portal) configuration to an operator panel using MPI/PROFIBUS? http://support.automation.siemens.com/ww/view/en/58668002 3. Application Remote access to SIMATIC HMI Panels http://support.automation.siemens.com/ww/view/en/109476153 4. Manual WinCC Comfort / WinCC Advanced V12.0 http://support.automation.siemens.com/ww/view/en/68075405 WinCC flexible 2008 Table 5-2 Type Link 1. FAQ Which connector cables are available for connecting to SIMATIC Panels? http://support.automation.siemens.com/ww/view/en/19109408 2. FAQ How can you transfer a WinCC flexible project via MPI/PROFIBUS to a Windows-based panel? http://support.automation.siemens.com/ww/view/en/23802404 3. FAQ What settings have to be made for a PROFIBUS DP connection between a panel or a PC with WinCC flexible Runtime and an S7-200? http://support.automation.siemens.com/ww/view/en/19839489 4. FAQ How do you configure a connection between WinCC flexible Runtime (PC/Panel) and an S7-300/S7400 via PROFIBUS/MPI? http://support.automation.siemens.com/ww/view/en/42918861 5. FAQ How do you use WinCC flexible to configure communication between an operator panel and an S7 station via S7 routing? http://support.automation.siemens.com/ww/view/en/22257781 6. Manual SIMATIC HMI WinCC flexible 2008 WinCC flexible 2008 Compact / Standard / Advanced http://support.automation.siemens.com/ww/view/en/18796010 Entry ID: 88633853, V1.0, 03/2014 26