Manual for firmware 1.15 and subsequent

Similar documents
LAN Controller manual

IP Power Socket 6G10A v2

IP Power Socket 5G10A V2

Manual LAN Controller V2.0 Firmware: HOME: from 3.13 ISP: from 2.09

ESPino - Specifications

Product description Rev. 3 11/06/14

keyestudio Keyestudio MEGA 2560 R3 Board

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

EZmoto V4.1 Product description Rev. 2 30/07/2015

LAN CONTROLLER RESTARTER, MONITOR, WATCHDOG, CONTROLLER FEATURES: Default user and password is admin, IP adress is

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

P4S-341 User Manual > Introduction. Overview

ARDUINO LEONARDO WITH HEADERS Code: A000057

ARDUINO LEONARDO ETH Code: A000022

ARDUINO YÚN Code: A000008

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20

GSM 4 click MIKROE Weight: 33 g

GSM communicator GD-06 Allegro Complete manual

DATA LOGGER GEOLOGGER G8 PLUS

GSM communicator G16 USER MANUAL

GPRS/SMS Reporting Module GPRS-T2

P4S-342 User Manual > Introduction. Overview

ARDUINO MICRO WITHOUT HEADERS Code: A000093

RS485 CO2 sensor etc. all of these functions for smart home are pre-programed

WiLARM-ONE GSM Module Installer Manual Version: 2.0

GPRS-T4. GPRS/SMS Reporting Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

USER MANUAL FOR GS100/GS1003G

ARDUINO INDUSTRIAL 1 01 Code: A000126

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

P4M-400 User Manual > Introduction. Introduction

FIFOTRACK MOTORCYCLE/VEHICLE GPS TRACKER

and/or b. an optional internal Iridium satellite modem.

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

GSM Communicator PSTN SIA DC-05 Protocol to SIA DC-09 Protocol & SMS Alert

Poseidon 4002 MANUAL

GSM Controller BR160SM-2SMT-4A-A / BR161SM-2SMT-4A-A

GSM Controller BR160SM-Sd BR161SM-Sd V1.2

ARDUINO PRIMO. Code: A000135

FIFOTRACK VEHICLE GPS TRACKER. Model: S30 Version: V1.1

Arduino Uno. Arduino Uno R3 Front. Arduino Uno R2 Front

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

Bolt 18F2550 System Hardware Manual

ARDUINO YÚN MINI Code: A000108

SimPLC. User Manual.

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

GSM HOME SECURITY SYSTEM

ARDUINO MEGA ADK REV3 Code: A000069

User Manual Revision 1.02

ARDUINO MEGA 2560 REV3 Code: A000067

Power Supply. SIM Card. LED indicators

Industrial Tri-band 3G Modem GTM-201-3GWA Series. User Manual

ARDUINO M0 PRO Code: A000111

ARDUINO UNO REV3 SMD Code: A The board everybody gets started with, based on the ATmega328 (SMD).

Tu Sitio de Automatización!

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

Edge Power International (HK) Ltd. Product Specification

GC 055. GSM Remote Monitoring. Operating and installation instructions

GT-HE910-EUD Product description Rev. 9 17/03/2013

ARDUINO UNO REV3 Code: A000066

NX21 USER MANUAL. Telemetry Unit. Version 1.5

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher

GPRS-T6. GPRS/SMS Reporting Module with Power Supply

Sanguino TSB. Introduction: Features:

FM4200 Sample Advanced User Guide

Mega128-Net Mega128-Net Mega128 AVR Boot Loader Mega128-Net

INSTALLATION MANUAL Z-UMTS

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

EZ864 UMTS Terminal Telit Cellular GSM Engine

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723

Installation of the PCMeasure Movement Sensor (30114)

TrackingTheWorld Global Asset Tracker (GAT)

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 1/24/2011

HWg-Tg11 First steps for remote monitoring & logging via GSM/GPRS

RM6000 GPRS Modem / Router

Arduino ADK Rev.3 Board A000069

The intelligent weather station system based on Arduino

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

RN-174 WiFly Super Module

RS485 MODBUS Module 6RO

WBD-222. Hardware Manual. Revision September Copyright 2010 WILIGEAR

Netbiter EC300 Series

IP71B Ethernet Singlechip Interface Converter User Manual

GPRS Pager 3 INSTALATION AND USER MANUAL

INDEX. Network Power Monitor R10 SNMP

GPS Tracker AT06 manual Ver

Microcontroller. BV523 32bit Microcontroller. Product specification. Jun 2011 V0.a. ByVac Page 1 of 8

QUADIMODO. Quad-Band IP68 GSM MODEM. Quad Band for Worldwide Use. IP68 Enclosure Submersible. Voice / Fax / SMS and Data. GPRS Class B Class 10:

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

VM300_2V0_ WiFi Module Specification

RS485 MODBUS Module 8AO

GreenEye Monitor Specifications

Beetle SKU:DFR0282. Contents. Introduction

User s Manual of Board ET-ESP32 WROVER MODULE V1 ET-ESP32 WROVER MODULE V1

DEMO XTR-8LR100 DEMO XTR-8LR10 User Manual

Transcription:

GSM Controller v3.0 Manual for firmware 1.15 and subsequent

GSM Controller GSM v3 controller allow monitor by gsm network different phisical parameters and control remotely on/off 5 outputs. Control is done through SMS messages and monitoring can be run by SMS or gprs data transmission to internet server. Http datas can be sent for example to www.thingspeak.com server, where are not only collected but can be read as dynamically presented graphs. Further GSM controller functionality is action automating. After simple set up when some input parameters reach the set size, outputs actions will be performed, eg send a message or switching outputs. Examples ISP control power supply - notification of his disappearance reserve battery voltage control temperature control or the presence of people in the server and I reaction Home automation automatic control of the radiator and notification of status or temperature control on / off lighting or other devices remotely or by part program simple alarm system notification Fittings temperature control and possible notification, switching valve, etc. monitoring of voltage and possibly automatic switching to source spare Monitoring for Environment and agriculture collection of environmental data with the extensive grounds the meteorological monitoring 2

3 manual GSM Controller v3.0 GSMKON-030 RESTARTER, MONITOR, WATCHDOG, CONTROLLER BASIC POSSIBILITIES: management by SMS or USB (after connecting to computer), monitoring by gprs transmission to http server, by SMS received on user phone or by USB, upgrade new firmware by USB port monitoring logic states, for example move sensors, position detectors measurment of voltage, temperature, humidity i and many more by analog voltage inputs pulse counting on INP4D transistor output (up to 1A), possibility to connect additinal board with 4 realys or PoE injector with power switching SMS or http notification about logical inputs supported sensors: PT1000, DS18B20, DHT22 (temperature and humidity) up to 99 phone numbers in memory allowing to controll - solution for gate opener in restricted areas command authentication by password remote power supply measurement. The default authorization code is 1234, Technical specification GSM module bands 900 / 1800 / 1900 MHz SIM interface 1,8 and 3V USB interface virtual COM port (115200, 8 bits, 1 bit stop, no parity, no parity and flow control) other interfaces 1-Wire (RJ11), SPI, I2C, UART transistor out 1 x 1A / turn on supply voltage OC outs 4x outs open collector type, transistor BC847B (45V-100mA) logical inputs 4 pcs., max. 20V analog inputs 3 pcs., 2x voltage 0 3,6V, 1x voltage 0 36V temperature meas. 1x PT1000, 1 wire sensors x8 DS18B20 antenna attached input power supply 6 28V DC, socket size 5,5 mm power consumption 0.3W without GSM transmission operational temp. from 20 to +70 C board size 68 x 61 mm board weight 57g

INPUT/OUTPUT: 1 TRANSISTOR OUTPUT: to power other devices, it gets voltage from the power supply, max 28V - 1A 4 OUTPUT open collector type (transistor BC847B): for switching relays, PoE ports, or other devices; 4 LOGICAL INPUTS: to monitor other devices, such as power supply units, the reed switches. Cooperation with the outputs of OC, NO, NC 4 ANALOG INPUTS, 12-bit converter INP1A: voltage measurement to 35V INP2: voltage measurement to 3.3V INP3: voltage measurement to 3.3V PT1000: for connecting a temperature sensor PT1000 SENSOR INTERFACE for DHT22: humidity measurement BUS 1-Wire (RJ11 connector): for connecting the sensor DS18B20, max 8 pieces, USB BUS: to configure the module, a preview of sensors and software updates I2C BUS: for connecting additional sensors, expansion platelets, not supported in version 1.0. UART INTERFACE: for connecting additional sensors, expansion platelets, not supported in version 1.0. SPI INTERFACE: for connecting additional sensors, expansion platelets, not supported in version 1.0. 4

PINS and COMPONENTS DESCRIPTION manual GSM Controller v3.0 GSMKON-030 Upgrade PIN SIM card socket LED4 - GSM LED antena, SMA micro USB INP6 - RJ11- bus 1-Wire for DS18B20 Supply max 28V Wake Up DT SCK RST 3.3V SCL SDA 3.3V DHT22 3.3V Rx Tx 3.3V IDC10 4.2V PWR } INP1D INP2D INP3D INP4D OUT0=Usupply INP3A - U 0 3.3 V INP2A - U 0 3.3 V INP1A - U 0 36 V PT1000 digital inputs LED3 - Status LED LED2 - Status LED LED1 - Power LED PIN / Component Power LED1 Power (green) LED2 Status (red) LED3 - Status (amber) LED4 GSM (green) IDC10 INP1 3D INP4D OUT0 Description Power supply 6V 28V DC Shine LED means power on board Shine with LED3 after start - wrong PIN. Blink when command is running Fast blinking when system starts up, 1 flash per second means system logged and ready to work Start fast blinking when GSM module starts up, flashes slowly when in base station range To connect additional relay board Logical inputs Logical input, pulse counter General ground Transistor output (+), voltage = power supply, max 1A INP3A Input for voltage measure 0 3.3V INP2A Input for voltage measure 0 3.3V INP1A Input for voltage measure 0 35V PT1000 Input for PT1000 sensor for high temperature measure DHT22 To connect the humidity sensor DHT22 micro USB For managing and software updating Upgrade PIN + For software updating - activates Bootloader mode 5

IDC10 and RJ11 (bus 1-Wire): OUT1 10 OUT2 8 OUT3 6 OUT4 4 2 IDC10-1 9 VCC 7 PWM 5 3 +3,6 V 1 1-Wire not VCC=3.6V used POWER max 28 V micro USB antenna, SMA DESCRIPTION OF COMMANDS: Commands can be issued by SMS or via a dedicated application or any terminal (eg Hyperterminal in Windows) that supports COM serial ports. The command issued by the SMS is: authorization code: command = parameters for example: 1234:reboot=1,2,t3 activates output 1 and 2 for 3 seconds. Commands issued by the terminal are not preceded by an authorization code, authorization code we give only the first time you log in after turning on the device. The command help (available only through the terminal) displays all available commands. Commands can be read and write or read-only, read-only commands given without any arguments. Command to read and write must have parameters: to record the equal sign = for reading question mark? for example: time=4 sets the default time switching outputs for 4 seconds, time? reads the set time. 6

LIST OF COMMANDS: manual GSM Controller v3.0 GSMKON-030 1. reboot activates certain output / output for the specified time reboot=3,4 will switch outputs 3 and 4 to the default time set by the command "time"; reboot=1,0,3,t34 activates output 1, 0 (transistor output), 3 at time 34 seconds; reboot? reads the current state of the outputs, to check whether switching time set has already elapsed 2. on output activates on=1,2,3,4,0 turns on all outputs on=0 activates only output 0 (transistor) 3. off output switched off off=1,2 off output 1 and 2 4. time sets the default output switching, as we spend reboot command without a parameter t 5. code sets the authorization code, by default 4 digit code 1234; 6. pin set a 4-digit PIN on your SIM card, if the card requires a pin. You need to set the pin as a set card. NOTE: The command does not change the pin on the card itself 7. inpd reads the state of the digital inputs (logic), read-only command 8. outs reads the current state of the outputs, the command read-only 9. number sets one of the 100 telephone number that will be able to execute when you call on the device. Up to 12 digits. In addition to the first four numbers (from position 1 to 4) will also be sent SMS messages (if enabled monitoring logic inputs) in the case of changes in the inputs. The number of phone numbers (1 to 4) which will be sent SMS, define command acnumber. number=1:666777888 sets the phone number for the first position number?1 reads the number of the first position 10. acnumber sets the number of active phone numbers for SMS alerts 11. call sets the function called when dialing device call=reboot=1,2,t3 when dialing reboot function will be called with parameters as given 12. remouts enter the value of 1 causes the output states when remembering switched on again 13. uptime shows the amount of time elapsed since the inclusion of the device, read- -only command 7

14. name sets the name of the device, max. 32 characters name=home device 15. upgrade runs the bootloader mode to update the software, flash simultaneously LED2 and LED3, to update special software is needed, the command without parameters 16. desinpd content of the notifications sent when changing the state of the logic inputs desinpd=1:0:test content sets the content for INP1D, sent the high state on this input desinpd=1:1:content test2 sets the content for INP1D, sent the low state at this input desinpd?1 reads the setting content for INP1D desinpd=2:0:test content sets the content for INP2D, sent the high state on this input 17. desanalog content of the notifications for the analog inputs, the numbers are: 1 VIN, 2 PT1000 3 INP1A, 4 INP2A, 5 INP3A The software 1.0 notifications only come to the VIN (supply voltage) desanalog=1:0:test content sets the content of the VIN (voltage), if exceeded more than set desanalog=1:1:test content2 sets the content of the VIN (voltage) if it is dropped below the set desanalog=2:0:test content sets the content for the PT1000, if exceeded more than set 18. monitoron enables monitoring of the selected logic input monitoron=1,2,3,4 enables monitoring of all four inputs monitoron=1 enables monitoring only INP1D if the previous were previously on, it is necessary to disable the command monitoroff monitoron? verify that the inputs are included to monitoring 19. monitoroff disables the monitoring logic inputs monitoroff=1,2 off input monitoring INP1D and INP2D, will not be a notifications in changed states of these inputs 20. version shows the current versions of the hardware (HW) and software (SW), read- -only command 21. adcprint displays the status of each input every 2 seconds, the command works only in the terminal adcprint=1 automatically displays the values of VIN, PT1000, INP1A, INP2A, INP3A, DHTT (DHT temperature), DHTH (DHT humidity) for the voltage to obtain a result in volts value 8

must be divided by 100, for PT1000 and DHT divided by 10. adcprint=2 displays the values directly (without any conversion to a voltage as above) with 12-bit converter for analog inputs VIN, PT1000, INP1A, INP2A, INP3A, values can vary from 0 to 4096, depending on the size of the measured voltage, eg for INP1A - for 0 volts will be set to 0, the 35V will be similar to 4096, for INP2A and INP3A, for 0 volts is 0 for 3.3V will be close to 4096. adcprint=3 displays the values of the sensors DS18B20, the result must be divided by 10 adcprint=0 disables the display of the above-mentioned values 22. confirm value of 1 enables sending return SMS after commands: reboot, on, off 23. vinread reads the value of VIN (the supply voltage), read-only command 24. ptread reads the value of PT1000, read-only command, 25. inp1aread reads the value of INP1A, read-only command 26. inp2aread reads the value of INP2A, read-only command 27. inp3aread reads the value of INP3A, read-only command 28. dthtread reads the value of the temperature DHT sensor, a read-only command 29. dthhread reads the value of the humidity DHT sensor, a read-only command 30. dsread reads the value of 8 sensors DS18B20, read-only command 31. vinset sets the voltage at which, if exceeded / decrease will be sent SMS vinset=12,34 sets the value of the 12.34V vinset? reads the set value 32. vinhis sets the hysteresis for the above set voltage vinhis=0,80 histereza ±0,80V 33. gprsapn sets the apn, username and password for GPRS gprsapn= internet, user, paswd enter values as in the example of quotes, below an example of how to set a blank password and user gprsapn= internet,, 34. gprsstart GPRS starts, you do not have to run like we want to send data to the server via HTTP 35. gprsstop stops GPRS 35. httpver sets the http client version httpver=1 sets the http client versions 1.1 httpver=0 sets the http client versions 1.0 9

36. httpurl sets the url as GET requests sent to the server httpurl=api.thingspeak.com/update?key=h2pn0o35krvrg6q0&field1=#1,&field2=#2 hash of the value is the number of the sensor, and this place will insert the value of this sensor. The following numbering for individual inputs / sensors. The first five mean values directly from the transmitter VIN_ADC 0 PT1000_ADC 1 INP1A_ADC 2 INP2A _ADC 3 INP3A _ADC 4 VIN 5 PT1000 6 INP1A 7 INP2A 8 INP3A 9 DTHT 10 DTHH 11 HTST 12 HTSH 13 14 DIFF 15 DS1 16 DS2 17 DS3 18 DS4 19 DS5 20 DS6 21 DS7 22 DS8 23 INP4D_impulsy 24 37. httpsend send typed url GET request to the server 38. httpautosend automatically send data to the server at a specified time httpautosend =15 sending every 15 seconds httpautosend =0 are switched off. The minimum value is 10 seconds as you type less, and so it will be set to 10 seconds 39. inp4con enter 1 turns on at the input pulse counting INP4D 40. inp4count reads the number of pulses counted or resets the counter inp4cont=0 resets the counted pulses inp4count? reads the pulses counted 10

41. cusd sending short codes cusd=*100# shows the status of the account on the GSM operator (PLUS (PL)) 42. signal reads the GSM signal strength 43. upinpd determines the logic input activates the state of high upinpd=1,3 INP1D input and INP3D activated state of high upinpd? reads the settings 44. downinpd determines the logic input activates the low status downinpd=1,3 INP1D input and INP3D activated by the low status 45. restart reboot the device 46. settingsreset enter 1 to restart the settings stored in the memory to default, reset occurs when you turn on the device, as you enter a value of 0 before re-run the device will not reset 47. help displays all the commands 11

Software upgrade Upgrade PIN micro USB POWER max 28 V 2 1 Upgrade Procedure Turn off the power. Connect GSM v3 controller to a Windows computer via a USB cable. Short together the pins Upgrade and. Turn on the power - the controller will start in bootloader mode. (system should recognize and install the DFU driver) Start the application GSM3upgrade.exe If Windows is properly installed drivers that recognize the board as: STM Device in DFU Mode Select new firmware file using Open File (in the window opening change preview from DFU files to All files) Press the upgrade button After uploading the firmware (first waiting for the progress bar one, then the second), you can exit the program and reset the GSM controller. Contents of the instructions is regularly checked and if necessary corrected. If the observations errors or inaccuracies, please contact us. It can not be ruled out that, despite best efforts, however, some discrepancies arose. To get the latest version, please contact us or distributors. Konsorcjum ATS Sp.J. Copying, duplication, reproduction whole or in part without the consent of the owner is prohibited. Konsorcjum ATS Sp.J. ul. Żeromskiego 75, 26 600 Radom, POLAND tel./fax: +48 48 383 00 30, e-mail: sales@ledon.eu, www.ledats.pl, www.wirelesslan.pl, www.ats.pl 12