MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

Similar documents
BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Replacing the Power Supply

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

JAN 16 Rev B

Spec Sheet. OmniReach FTTX Solutions DLX Fiber Optic Connector

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Design. Application. All closure sizes are available with three different fiber management systems included in the pack.

INSTALLATION INSTRUCTIONS

Vacuum Maintenance Manual (EXCERPT Tim Benedict)

NetCommWireless. Quick Start Guide NTC-30 Series - Outdoor WiFi Router

Product information 19" 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Standard Strip Series

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Installing a Power over Ethernet injector

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Indoor Protected Entrance Terminal 4588 Series

Miniature outside plant plug-and-play solutions. White paper

Operating Instructions

3 Angled Connector Housing (MC) Installation

DIGITAL Server Rackmount Installation Guide

Mounting on the Ceiling Using Flush Mount (Face Down)

PHOS mini OPERATING INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Removal and Installation8

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

Fiber Management Tray (FMT) User Manual

INSTALL INSTRUCTIONS RSXMR-9886-P-48

Service & Maintenance

IS-DM220/IR/HB IS-DM220

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C)

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series

PRODUCT MARKING AND BARCODE IDENTIFICATION. up to Serial No Barcode/Label printer MACH4. Service Manual. Edition 11/06

HDR TM K HOIST DRUM ROTATION INDICATOR KIT

4888 and 4988 Outdoor Protected Entrance Terminals

Quick Start Guide. Preparation. Installation. Operation. Support. Vaisala NOMAD 3 Data Logger. Online manuals

Installation Manual. Table of Contents

CINTENNA ANTENNA REPAIR GUIDE

Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2

Removal and Installation 8

Megatouch FORCE Monitor Chassis Board Replacement

WINSTA. Full Line Catalog 2008/2009

JUN 2016 Rev B

Installing Power Modules

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

M204SMB Surface Mount Box Instructions

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

Pre-polished Connector Insertion Loss and Termination Yield. Achieving High Termination Yields And Low Insertion Loss Values

Encore XT Manual Gun Upgrade Kit

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

G12/G12x USER S MANUAL

SUBCON 15 HD (High-density) D-Subminiature Connectors

Rack Installation Instructions

Prisma II Chassis 56-Port Upgrade Technical Bulletin

21 TRACK MAINTENANCE GUIDE

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749

ibook G3 14" Top Shield Replacement

Installation Notes TII Model 341 Protector

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

FLEX Ex Spring Clamp Terminal Base

and Network Interface Modules Installation Instructions

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

3M Indoor Protected Building Entrance Terminal 4588V-QCS Series

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Control Box Setup - PRSalpha

Raven Adapter Harness

Flat Panel Static Wall Mount MSP-SS (GSM-210)

E1135C PDU and Pod Upgrade Procedure

ibook G3 14" Hard Drive Replacement

Installing 6 Indexer: PRS Standard Tools

DirectCommand Installation Case/Flexi-Coil/New Holland Air Cart Kit (Variable Rate Electro Hydraulic Systems) Ag Leader Technology

Extra Large Full Motion TV Mount for Televisions

TDM To MiniMech conversion ProceDure

System Storage EXP3000 Rack Installation Instructions

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

SITRANS F Coriolis Flowmeters SITRANS FCT030 transmitter Quick Start

Power Supply and Fan Module Installation

Quick Start Guide V5.1.

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

HD Flex Zero RU Cassette Holder and Bracket

Removing and Replacing Parts

for a perfect electrical installation. The range of rail-mounted terminal blocks

3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

2 Wire Digital Phone Fiber Link Card System

Quick Start Guide BEC G/LTE Outdoor Router

Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Installation manual plugs and connectors with screw connection (16/32 A)

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

TEC APO 200 OWNER S MANUAL

If you are missing any of the following items, please contact Stanton Video immediately (602)

FLOE WIRELESS REMOTE ASSEMBLY INSTRUCTIONS KIT P/N

Transcription:

INSTALLATION MANUAL HUBER+SUHNER AG Fiber Optics MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLU HV 4/12) blunt cut at BTS side DOC-0000803885 Rev A June 18, 2018 Page 1 of 12 (MLUH HV 4/12) blunt cut at BTS side TABLE OF CONTENT SAFETY NOTES... 1 HANDLING OF THE CABLING SYSTEM... 1 HANDLING OF FIBER OPTIC ASSEMBLIES... 1 RRH END OF ASSEMBLY... 2 BASE STATION END OF ASSEMBLY... 9 FIBRE OPTIC ALLOCATION... 11 POWER CODING... 11 REVISION HISTORY... 12 SAFETY NOTES Installation and maintenance work on this device may only be carried out by an authorized electrician. National laws and regulations must be observed during installation. The housing and the components used must be checked for exterior damage prior to installation. If the cabling system is defective, it may not be used. HANDLING OF THE CABLING SYSTEM To avoid any damage due to improper installation, please keep in mind below points: AVOID any additional stress on connector head by twisting or bending when routing or locating it AVOID installation path around any sharp objects AVOID uncontrolled knocking of connector head on any hard object AVOID any contact of connector head with any additional substance such as glue/oil/fat etc. unless prior authorization is given by HUBER+SUHNER AG See also User handling manual for cables and cable systems on www.hubersuhner.com/en/support HANDLING OF FIBER OPTIC ASSEMBLIES In order to guarantee the performance, fiber optic assemblies need to be treaded carefully and with attention on the minimum bend radius and never exposed to dirt. See also User handling manual for cables and cable systems on www.hubersuhner.com/en/support

Page 2 of 12 RRH END OF ASSEMBLY Step 1 Use a smartphone to scan the QR code which is attached on the side of the reel. The QR code leads on HUBER+SUHNER s website with the latest valid revision of the installation video and installation manual. Step 2 Unpack the mounting bracket. It is packed together with the protection cover in a cardboard box. Secure the mounting bracket with hose clamps (when fitting to a pole/mast) or screws (when fitting to a wall). We recommend to use Huber+Suhner s quick hose clamps and to tighten the clamps with a torque of 4.0 Nm item no. 84076411 (pole Ø 30 155mm) item no. 84076412 (pole Ø 60 500mm) Step 3 Mount the cable spool onto suitable de-reeling equipment. Start unwinding from the side where the MLUH connector head is located. Do not pull on the side where the pulling tube is attached. Make sure, that the spool can rotate freely when unspooling. Remove the protection bubble foil only right before attaching the MLUH connector head to the mounting bracket.

Page 3 of 12 Step 4 Use a rope to pull up the cable system. Check the maximum pulling force on the label attached to the hoisting grip. Do not apply higher force! The maximum pulling force equates to the weight of 160m cable. The cable weight is specified on the data sheet.. Lead the rope along the left side of the MLUH connector head down onto the cable hoist and secure it. Fix the rope with 2 tapes to the lower and upper end of the connector head. Do not remove the air bubble bag which protects the connector head while lifting the cabling system. Pull the cabling system up the mast. Make sure that the MLUH connector head does not hit against any constructions and does not get bent over edges. Note: 950N / 95kg is only an example and depends on the hybrid cable used

Page 4 of 12 Step 5 Remove the MLUH head fixation (tape) from the rope and the air bubble bag from the MLUH connector head. Hook MLUH head into the mounting bracket. Do not remove the rope from the hoisting grip before all cable clamps are mounted. Step 6 Secure the MLUH connector head at the mounting bracket by tightening the two M6 screws on the bottom left and top right corner. Tight the M6 screws with a torque of 2 Nm. Be careful not to damage the housing by tightening the screws too tightly. Step 7 Fix the cable to the mast using HUBER+SUHNER clamps, which are available for different profiles. Recommended spacing between the clamps is 1m. Clamps should be applied to hybrid cable starting from a point 0.5m to 1.0m below the cable entry proceeding down to the bottom of the mast. The cable has to be fixed straight and in line (maximum 5 ) with the MLUH enclosure between the cable entry and the first cable clamp. Minimum bending radius of the cable is 10x cable diameter. After all cable clamps are attached, remove the rope. Do not remove the rope before all cable clamps are mounted.

Page 5 of 12 Step 8 The MLUH enclosure has an integral earth point suitable for M8 lug for grounding. Connect the earth point to an earth bar with a grounding assembly with minimum 16mm 2 / 6 AWG cross section. Consider the correct order: first the grounding wire lug, secondly the washer, thirdly the spring washer. Tighten the M8 earth screw with a torque of 5 Nm. Be careful not to damage the enclosure by tightening the M8 earth screw too tightly. HUBER+SUHNER offers different grounding assemblies: Item no. 85086667: 0.5m, black, 16mm 2, 2x M8 lug Item no. 85083781: 0.5m, yellow/green, 16mm 2, 2x M8 lug Item no. 85086668: 0.5m, black, 25mm 2, 2x M8 lug Item no. 85083792: 0.5m, yellow/green, 25mm 2, 2x M8 lug Step 9 All connectors (fiber optic and power) are protected with water proof (IP67) protection caps. Do not remove the cap if no jumper cable is connected. When removing the cap instently mate the plug connector to avoid dirt entering the connector. Step 10 Protection cover mounting: Flex off the two cover flaps on the top over the two mounting spigots from the housing base. Open the cover by 90 to latch it with the housing base.

Page 6 of 12 Pull down the cover to unlatch. Flex off the cover on the bottom and move the slits above the two mounting bracket saddles. Secure the protection cover with the two splints attached to the bracket. Step 11 The remote radios are connected with fiber optic jumpers, which are terminated with Q-ODC-2 plug connectors and RRH compatible interfaces. The power jumpers are terminated with a rugged circular plastic plug connector and are blunt cut on the RRH side.

Page 7 of 12 Step 12 Connect the power jumpers. The 4 power connector sockets are marked with the letters A, B, C and D Switch off the power supply before you mate or un-mate the power connector. Otherwise the contacts will get damaged. Connector is not for hot plugging. Mating: Remove protection caps of the plug. Twist (120 ) the coupling ring of the plug connector to remove protecting cap as shown. Note the lock / unlock symbol on the coupling ring. lock / unlock symbol Remove protection caps of the socket on the MLUH. Twist (120 ) the coupling ring of the socket connector anticlockwise to remove protecting cap as shown. Connect the two protection caps together for later reuse. Push plug connector slightly and in-line into socket connector, rotate to find keying position, twist coupling ring of the plug connector clockwise as shown until you hear and feel a click. Align white strip on the plug with the white strip on the socket to find keying position easier. Make sure the plug connector is in-line with the socket connector before coupling ring is twisted. Otherwise the connector might be damaged. white strip on the socket and plug Avoid any tilt during mating process since the connector might be damaged Un-mating: Twist coupling ring anticlockwise as shown to un-mate the plug connector. Note the lock / unlock symbol. Mount the protection cap to avoid ingress of water or dirt. lock / unlock symbol

Page 8 of 12 Step 13 Connect FO jumper. The 12 Q-ODC-2 fiber optic connectors are marked with the numbers 1 to 12, starting with 1 at the left side at the bottom row and ends with 12 at the right side at the top row. Mating: Remove protection caps of the plug and socket. Connect instantly the jumper cable to avoid ingress of water or dirt. Push plug connector slightly into socket connector, rotate to find keying position, push connector to mate. Mated - connector snaps in and is fully strain relieved. Connect the two protection caps together for later reuse. Un-mating: Pull coupling ring to un-mate. Mount instantly the protection cap to avoid ingress of water or dirt. All HUBER+SUHNER fiber optic assemblies are 100% manufactured in an industrial environment and are governed by standards which are implemented and controlled within the factory environment. The fiber optic cable assemblies as well as the fiber optic systems are inspected for insertion loss and the cleanliness of the ferrule end face. Factoryterminated fiber optic connectors supplied to the market are cleaned and ready for installation. Despite our careful control, contamination of dust or microscopically small parts on the end faces cannot be 100% excluded. If cleaning is necessary see cleaning instruction on www.hubersuhner.com/en/support Step 14 Ensure smooth routing of all cables from connector head to RRH equipment using HUBER+SUHNER cable clamps, which are available for different profiles. Do not over bend the cables. Minimum bend radius for power cable and fiber optic cable is 10 cm. Avoid side load on the power and fiber optic connector. Do not use cable ties to fix cables

Page 9 of 12 BASE STATION END OF ASSEMBLY Step 1 Feed the hybrid cable through cabinet/cabin. Step 2 Mark the strip-back point using tape. Step 3 If a cable gland is used, feed the nut over cable to secure the cable entry gland. Step 4 Remove the end cap and unwind black tape to reveal rip cord. This cord is used to open the cable jacket and gain access to the cable elements within. Step 5 Use a screwdriver (or similar) to cut the cable jacket with the rip cord back to the strip-back point marked with the tape. The angle between the hybrid cable and the rip cord should be approx. 45. Step 6 Remove cable jacket carefully.

Page 10 of 12 Step 7 Carefully unwind the fibre optic cable element from the DC tails and form a loop to separate it. During this process (at any stage) ensure the fibre optic cable is not kinked. Do not over bend the cable. Minimum bend radius for the fiber optic cable is 8 cm. Step 8 If a cable gland at the entry point is used, tighten it to secure cable and ensure IP protection. Step 9 Route DC cable element to their respective termination points and connect. Route earth wire to earth bonding point and connect. Step 10 Store any fibre optic cable over-length inside base station by using cable over-length storage box which can be mounted on a wall, panel or mounted horizontally within an equipment rack. Over length box Item no 84103325 Step 11 (MLUH HV 4/12) blunt cut at BTS side is not connectorised at the bottom end. Splice process is not part of this installation manual

Page 11 of 12 FIBRE OPTIC ALLOCATION POWER CODING

Page 12 of 12 REVISION HISTORY Revision Description of detailed changes Manager/Engineer Applicable date Rev. A Marco Senn 2018-06-18